• Title/Summary/Keyword: Site release

Search Result 323, Processing Time 0.022 seconds

A Study on Annual Release Objectives and Annual Release Limits of Gaseous Effluents During Decommissioning of Nuclear Power Plants (원전 해체 시 기체상 유출물의 연간 방출관리치 및 방출한도치에 관한 연구)

  • Lee, Seung-Hee;Hwang, Won-Tae;Kim, Chang-Lak
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.3
    • /
    • pp.299-311
    • /
    • 2019
  • Decommissioning is a critical issue in Korea. Although compared with the operation of nuclear power plants the release of radioactive materials during decommissioning is not expected to be significant, residents should always be protected from radiation exposure. To manage this effectively, Annual Release Objectives (ARO) and Annual Release Limits (ARL) were derived from dose standards in the NSSC Notice and dose limit for the public. Based on meteorological data for the three years from 2008 to 2010 in the Shin Kori nuclear power plant site, atmospheric dispersion and ground deposition factors of gaseous effluent were evaluated using the XOQDOQ computer code. The exposure dose was evaluated using the ENDOS-G computer code. Because of differences in radiological sensitivity according to age groups, the results of Annual Release Objectives (ARO) and Annual Release Limits (ARL) showed significant differences depending on the radionuclides. The evaluation methodology of this study will provide meaningful information for radioactive effluent management for decommissioning of nuclear power plants.

Mucoadhesion, Swelling and Drug Release Characteristics of Hydroxypropylcellulose/Carbopol Solid Dispersions (히드록시프로필셀룰로오스/카르보폴 고체분산체의 점막부착성과 팽윤 및 약물방출특성)

  • Kim, Sang-Heon;Yang, Su-Geun;Shin, Dong-Sun;Lee, Min-Suk;Choi, Young-Wook
    • Journal of Pharmaceutical Investigation
    • /
    • v.24 no.3
    • /
    • pp.155-165
    • /
    • 1994
  • Some mucoadhesive polymers such as hydroxypropylcelluose (HPC) and carbopol-934 (CP) have been employed for the preparation of mucoadhesive polymeric systems, and their physical properties including mucoadhesion, swelling, and drug release were evaluated. A new simple experimental technique that can quantitatively measure the bioadhesive properties of various polymeric systems has been developed by the methods of detachment force test. As the polymeric systems, the discs of freeze-dried HPC/CP solid dispersions were prepared. The mucosa used in these tests were upper, middle, and lower parts of small intestine of male rats weighing $300{\sim}350\;g$. Detachment forces were increased as the mole fraction of CP increased in discs of HPC/CP solid dispersions. In the points of intestinal site dependence of mucoadhesion, the solid dispersions revealed non-specific mucoadhesion to the intestine. Swelling and drug release characteristics of mucoadhesive polymeric systems were studied extensively to find out the feasibility for the oral controlled delivery systems. Swelling ratio, expressed as the final height/initial height, has been determined in various pH buffer solutions. Hydrochlorothiazide (HCT) was employed as a model drug for release study. Apparent swelling and drug release rate constants, $K_s$ and $K_r$ respectively, were obtained from the square-root time plot of either swelling ratio or released amount of drug, particularly for the time periods before reaching the equilibrium. As a result, the swelling ratio of HPC/CP solid dispersions was increased as the weight percentage of CP increased. Similarly, the release of HCT from the solid dispersions was dependent on pH changes and CP contents, resulted in the slower release of HCT with the increases of pH and CP contents.

  • PDF

Development Of A Windows-Based Predictive Model For Estimating Sediment Resuspension And Contaminant Release From Dredging Operations

  • Je, Chung-Hwan;Kim, Kyung-Sub
    • Water Engineering Research
    • /
    • v.1 no.2
    • /
    • pp.137-146
    • /
    • 2000
  • A windows-based software package, named DREDGE, is developed for estimating sediment resuspension and contaminant release during dredging operations. DREDGE allows user to enter the necessary dredge information, site characteristics, operational data, and contaminant characteristics, then calculates an array of concentration using the given values. The program mainly consists of the near-field models, which are obtained empirically, for estimating sediment resuspension and the far-field models, which are obtained analytically, for suspended sediment transport. A linear equilibrium partitioning approach is applied to estimate particulate and dissolved contaminant concentrations. This software package which requires only a minimal amount of data consists of three components; user input, tabular output, and graphical output. Combining the near-field and far-field models into a user-friendly windows-based computer program can greatly save dredge operator's, planners', and regulators' efforts for estimating sediment transports and contaminant distribution.

  • PDF

SILICONE POLYMER FOR ANTIFOULING/FOULING RELEASE MARINE COATING APPLICATION

  • Choi, Seok-Bong;Jepperson, John;Thomas, Johnson;Jarabek, Laura;Chisholm, Bret;Boudjouk, Philip
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.378-378
    • /
    • 2006
  • The preparation, characterization, and bio-testing of biocide incorporated silicone coatings for marine applications have been conducted. Derivatives of the biocide, Triclosan (5-chloro-2-(2, 4-dichlorophenoxy) phenol), were used to covalently attach the biocide moiety to a silicone backbone. The synthetic process allowed for control of the resulting coating's mechanical properties as well as antifouling/fouling release performance in laboratory and ocean site testing. The test results showed significantly reduce macro fouling with sustained fouling release characteristics for the coatings produced.

  • PDF

Effects of Surface Charges on the Retention of Placenta-loaded Liposome Formulations Administered by Intramuscular Route

  • Noh, Sang-Myoung;Park, Da-Eui;Kim, Young-Bong;Oh, Yu-Kyoung
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.5
    • /
    • pp.333-337
    • /
    • 2009
  • We aimed to optimize the formulation of porcine placental extract (PPE)-loaded liposomes for intramuscular administration and to investigate the effect of surface charges on the muscular retention in mice. PPE-loaded liposomes were formulated to have neutral, anionic, or cationic surface charges. The in vitro release profiles were studied by spectrofluorometry. In vivo distribution patterns at mice were studied using molecular imaging technology. Among the three types of liposomes, 1,2-dioleoyl-3-trimethylammonium-propane and 1,2-dioleoyl-sn-glycero-3-phosphoethanolamine-based cationic liposomes showed the most prolonged in vitro release profile. Consistent with the in vitro results, the in vivo distribution study revealed that the cationic liposomes were retained at the site of administration for the longest period. Our results suggest the potential of cationic PPE-loaded liposomes for sustained release of the components after intramuscular administration.

Derivation of site-specific derived concentration guideline levels at Korea Research Reactor-1&2 sites

  • Kim, Geun-Ho;Do, Tae Gwan;Kwon, Jae;Ryu, Gangwoo;Kim, Kwang Pyo
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.493-500
    • /
    • 2022
  • The objective of this study was to derive derived concentration guideline levels (DCGLs) reflecting the site-specific characteristics of KRR-1&2. A total of 7 nuclides (H-3, C-14, Co-60, Sr-90, Cs-137, Eu-152, and Eu-154) were selected for DCGLs derivation. Radiation dose at the sites was evaluated with RESRAD-ONSITE program. The dose contribution due to direct external exposure was the highest during the entire evaluation period. Ingestion had the second effect. The DCGLs of Co-60 was derived to be 0.051 Bq/g, and DCGLs of Cs-137 was 0.193 Bq/g. The DCGLs of H-3 showed the highest value of 129 Bq/g. The ratio of DCGLs derived by applying site-specific values and default values ranged from 0.27 to 19.6. For six nuclides excluding H-3, KRR-1&2 sites and the overseas NPP sites showed similar DCGLs. H-3 showed large differences in DCGLs from this study and overseas NPPs. The large difference resulted from input parameter values applied to the sites. In conclusion, it is critical to apply site-specific parameter values reflecting the site characteristics to derive DCGLs for decommissioned site clearance. The result of this study can be used as a reference for nuclide selection and DCGLs derivation reflecting the site characteristics when decommissioning nuclear facilities, including nuclear power plants in Korea.

A Method for Identifying Splice Sites and Translation Start Sites in Human Genomic Sequences

  • Kim, Ki-Bong;Park, Kie-Jung;Kong, Eun-Bae
    • BMB Reports
    • /
    • v.35 no.5
    • /
    • pp.513-517
    • /
    • 2002
  • We describe a new method for identifying the sequences that signal the start of translation, and the boundaries between exons and introns (donor and acceptor sites) in human mRNA. According to the mandatory keyword, ORGANISM, and feature key, CDS, a large set of standard data for each signal site was extracted from the ASCII flat file, gbpri.seq, in the GenBank release 108.0. This was used to generate the scoring matrices, which summarize the sequence information for each signal site. The scoring matrices take into account the independent nucleotide frequencies between adjacent bases in each position within the signal site regions, and the relative weight on each nucleotide in proportion to their probabilities in the known signal sites. Using a scoring scheme that is based on the nucleotide scoring matrices, the method has great sensitivity and specificity when used to locate signals in uncharacterized human genomic DNA. These matrices are especially effective at distinguishing true and false sites.

Homing of the Serotine Bat, Eptesicus serotinus (Chiroptera: Vespertilionidae) (문둥이박쥐(Eptesicus serotinus)의 귀소성에 관한 연구)

  • Chung, Chul-Un;Kim, Sung-Chul;Han, Sang-Hoon
    • Journal of Environmental Science International
    • /
    • v.23 no.12
    • /
    • pp.2083-2087
    • /
    • 2014
  • Between May and September 2014, a total of 226 serotine bats (Eptesicus serotinus) were captured and subsequently released at a site 50 km distant from the site of capture, in order to determine the homing ability of the bats and changes in the homing rate according to the season. The bats were captured from a nursery colony at a bridge in An-dong (Gyeongbuk, Korea), and then released at a similar site in Yeong-Ju (Gyeongbuk, Korea). We found that 115 of the 226 bats released (51%) returned to the capture site. However, there was a difference in the homing ability of the serotine bats depending on the season and reproductive status. We found that the homing rate was the highest in June during late pregnancy and the lowest in August after the lactation period.

Offsite Risk Assessment on Flammable Hazard Site (가연성물질 저장설비의 사고시 사업장외에 미치는 영향평가)

  • Lee, Dong Hoon;Park, Kyo Shik;Kim, Tae Ok;Shin, Dong Min;Shin, Seo Yun
    • Korean Journal of Hazardous Materials
    • /
    • v.3 no.1
    • /
    • pp.52-58
    • /
    • 2015
  • Since the HF release in 2012 in Korea, it became one of the most significant to evaluate consequence to the vicinity of industry facilities handling hazardous materials. BTX plant is selected to assess off-site risk to check whether the facility satisfies the Chemical Control Law by Korea Government. Accident scenarios were listed using process safety information. The scenarios having effect to the off-site were selected and assessed further according to guideline provided by Korea government. Worst case and alternative scenarios including other interested scenarios were evaluated using ALOHA. Each evaluated scenario was assessed further considering countermeasures. The results showed that the facility handling chloric acid is safe enough and needed no further protections at the moment.

Study on the Distribution of Fluorides in Plants and the Estimation of Ambient Concentration of Hydrogen Fluoride Around the Area of the Accidental Release of Hydrogen Fluoride in Gumi (구미 불산 누출사고 지점 주변 식물의 불소화합물 농도 분포 및 공기 중 불화수소 농도 추정에 관한 연구)

  • Gu, Seulgi;Choi, Inja;Kim, Won;Sun, Oknam;Kim, Shinbum;Lee, Yungeun
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.4
    • /
    • pp.346-353
    • /
    • 2013
  • Objectives: The goal of this study is to identify the distribution of the foliar fluorine content of vegetation surrounding the area where hydrofluoric acid was accidently released in Gumi, Gyeongsangbuk-do on September 27, 2012. In addition, it also aims to estimate the concentration of hydrogen fluoride in the air on the day of the accident. Methods: Samples of plant leaves were collected on October 7, 2012 within 1 km from the site where the accident occurred. These samples were analyzed for soluble fluorine ion with an ion selective electrode. The ambient concentration of hydrogen fluoride was calculated using the fluoride content in the plant via the dose-rate equation (${\Delta}F$=KCT). Results: The arithmetic and geometric means of the concentrations were 2158.2 and 1183.7mg F $kg^{-1}$ for leaves and, 2.4 and 1.1 ppm HF for the air, respectively. The highest concentration of hydrogen fluoride in the air was 14.7 ppm, which is higher than the maximum concentration reported by the government (1 ppm) and the exposure limit (ceiling, 3 ppm). The concentrations of both fluorine and hydrogen fluoride decreased with increasing distance from the accident site and showed a significant decrease outside of a 500m radius from the site (p <0.05). Conclusions: The area around the accident site was highly polluted with hydrogen fluoride according to the results of this study. Considering the persistency of hydrogen fluoride in the environment, long-term monitoring and environmental impact assessment should be pursued.