• 제목/요약/키워드: Site coefficients

검색결과 333건 처리시간 0.024초

일조시간 및 운량을 이용한 태양고도에 따른 수평면 전일사 산출 (Generation of Horizontal Global Irradiance using the Cloud Cover and Sunshine Duration According to the Solar Altitude)

  • 이관호;재프 리버모어
    • 한국태양에너지학회 논문집
    • /
    • 제40권2호
    • /
    • pp.37-48
    • /
    • 2020
  • This study compares cloud radiation model (CRM) and sunshine fraction radiation model (SFRM) according to the solar altitude using hourly sunshine duration (SD) and cloud cover (CC) data. Solar irradiance measurements are not easy for the expensive measuring equipment and precise measuring technology. The two models with the site fitting and South Korea coefficients have been analyzed for fourteen cities of South Korea during the period (1986-2015) and evaluated using the root mean square error (RMSE) and the mean bias error (MBE). From the comparison of the results, it is found that the SFRM with the site fitting coefficients could be the best method for fourteen locations. It may be concluded that the SFRM models of South Korea coefficients generated in this study may be used reasonably well for calculating the hourly horizontal global irradiance (HGI) at any other location of South Korea.

Introduction to 1M telescope of Deokheung Optical Astronomy Observatory, National Youth Science Center (NYSC)

  • Kang, Wonseok;Lee, Sang-Gak;Kwon, Sun-Gill
    • 천문학회보
    • /
    • 제40권1호
    • /
    • pp.86.4-87
    • /
    • 2015
  • We will soon complete the installation of 1m telescope at Deokheung Optical Astronomy Observatory (DOAO), National Youth Space Center (NYSC). Before the test observation with NYSC 1m telescope, we present the specs of the 1M telescope and observational conditions of the DOAO site, such as the seeing data at DOAO and the atmospheric extinction coefficients obtained from the observations of standard stars and stellar clusters with 120mm and 150mm refractor in 2014. Since atmospheric extinction coefficients depend on the observational instruments as well as the atmospheric conditions of the site, the improved data with NYSC 1m telescope will be obtained right after the completion of 1M telescope installation. We are planning to invite all astronomers to use 1m telescope for their sciences via regular proposal processes in this year.

  • PDF

지역고유 지진응답 특성 정량화를 통한 국내 부지 분류 기준의 추가 반영 제안 (Suggestion of Additional Criteria for Site Categorization in Korea by Quantifying Regional Specific Characteristics on Seismic Response)

  • 선창국
    • 지구물리와물리탐사
    • /
    • 제13권3호
    • /
    • pp.203-218
    • /
    • 2010
  • 지진 지반운동의 증폭 유발 요인인 부지 효과는 지역적 및 국부적 부지 조건에 직접적인 영향을 받게 됨에도 불구하고, 현행 국내 내진 설계 기준의 부지 분류와 그에 따른 부지 증폭계수는 미국 서부 지역의 기준을 준용한다. 이러한 내진 기준의 경우, 단주기와 중장주기에 관한 두 종류의 부지 증폭계수들을 30 m 심도까지의 평균 전단파속도라는 기준에 따라 A 부터 E까지의 다섯 종류로 분류한다. 본 연구에서는 국내 부지 조건을 반영한 부지 분류 체계를 제시할 목적으로, 경주, 홍성, 해미, 사천의 네 지역에 대해 체계적인 부지 특성 평가를 수행하였으며, 현장에서는 지표면부터 기반암까지의 전단파속도 깊이분포를 결정하고 실내에서는 지반의 비선형적 물성을 획득하였다. 국내 토사층은 미국 서부에 비해 상대적으로 얕고 강성이 크게 파악되었고, 그로 인해 국내의 부지 주기는 상대적으로 작고 좁은 범위에 분포하였다. 현장과 실내에서 구한 지반 특성을 이용하여 등가선형 및 비선형 기법을 적용한 다양한 부지고유 지진응답 해석을 총 75부지를 대상으로 실시하였다. 해석 결과로부터 현행 국내 기준에 정의된 부지 증폭계수는 지반운동을 단주기에서는 과소 평가하고 중장주기에서는 과대평가함을 알 수 있었다. 이러한 차이는 국내와 미국 서부간의 기반암 심도를 포함한 국부적 지반 특성들의 차이로 인한 것이다. 본 연구의 해석 결과와 한반도 대상의 선행 연구 결과들을 토대로 대표 기준인 부지 주기와 추가 기준으로서의 30 m 보다 얕은 심도까지의 평균 전단파속도를 도입함으로써, 국내 지역적 부지 특성을 고려한 지반운동과 설계 스펙트럼을 신뢰성 높게 결정할 수 있는 새로운 부지 분류 체계를 개발하였다.

RI를 이용한 하천 현장실험 및 수치 모델링 (A Field Tracer Experiment by using RI and Numerical Modelling in River)

  • 김기철;천일용;정성희;이정렬;서경석
    • 방사선산업학회지
    • /
    • 제2권3호
    • /
    • pp.135-140
    • /
    • 2008
  • A field tracer experiment using radioisotope was carried out to investigate the characteristics of a pollutant transport and a determination of the dispersion coefficients in a river system. The dispersion coefficients in the longitudinal and transverse directions were determined by using the measured concentration of a radioisotope. The two-dimensional numerical models were applied to calculate the flow and concentration fields at the experimental site. Several numerical simulations were performed to investigate the effects of the numerical results according to variations of the dispersion coefficients. The calculated concentrations agreed well with the measured ones.

New site classification system and design response spectra in Korean seismic code

  • Kim, Dong-Soo;Manandhar, Satish;Cho, Hyung-Ik
    • Earthquakes and Structures
    • /
    • 제15권1호
    • /
    • pp.1-8
    • /
    • 2018
  • A new site classification system and site coefficients based on local site conditions in Korea were developed and implemented as a part of minimum design load requirements for general seismic design. The new site classification system adopted bedrock depth and average shear wave velocity of soil above the bedrock as parameters for site classification. These code provisions were passed through a public hearing process before it was enacted. The public hearing process recommended to modify the naming of site classes and adjust the amplification factors so that the level of short-period amplification is suitable for economical seismic design. In this paper, the new code provisions were assessed using dynamic centrifuge tests and by comparing the design response spectra (DRS) with records from 2016 Gyeongju earthquake, the largest earthquake in history of instrumental seismic observation in Korea. The dynamic centrifuge tests were performed to simulate the representative Korean site conditions, such as shallow depth to bedrock and short-period amplification characteristics, and the results corroborated with the new DRS. The Gyeongju earthquake records also showed good agreement with the DRS. In summary, the new code provisions are reliable for representing the site amplification characteristic of shallow bedrock condition in Korea.

치주질환 심도와 치은열구액내 Myeloperoxidase에 관한 연구 (A STUDY ON PERIODONTAL DISEASE SEVERITY AND MYELOPEROXIDASE IN GINGIVAL CREVICULAR FLUID)

  • 최병선;곽정민;김형섭
    • Journal of Periodontal and Implant Science
    • /
    • 제25권3호
    • /
    • pp.733-740
    • /
    • 1995
  • This investigation was undertaken to determine the relationship between the amount of polymorphonuclear leukocyte(PMN) enzyme myeloperoxidase(MPO) in gingival crevicular fluid(GCF) collected from active or control site and gingival disease status described by clinical indices(gingival index, papillary bleeding index, pocket depth, periotron unit). The results were as follows : 1. MPO activity/site was greater at active sites than at control sites. 2. According to increasing the clinical parameters, MPO/sites was higher statistically (P<0. 01, P<0.05). 3. High MPO(unit/site) groups was higher statistically than low MPO(unit/site) groups in various clinical parameters. 4. Correlation coefficients between MPO(unit/site) and GI, MPO($unit/{\mu}l$ GCF) and periotron unit were 0.4782, -0.5901, respectively.

  • PDF

시험방법에 따른 흡음률 비교 (Comparison of Absorption Coefficient according to Test Methods)

  • 이재원;구진회;박형규;강대준
    • 한국소음진동공학회논문집
    • /
    • 제17권5호
    • /
    • pp.373-378
    • /
    • 2007
  • Today, the use of the sound absorptive material is increasing to improve the room acoustics in the auditorium and music hall, etc. Usually, the sound absorption materials have been used to enhance the performance of a noise barrier and improve the room acoustics in construction site. Generally, the sound absorbtion coefficients are the most important factor reflecting the sound absorbtion performance. There are two methods to measure the sound absorption coefficient. The first one is the reverberation room method, and the second is the impedance tube method. In this study, we measure the sound absorbtion coefficients using these two methods, and then we compared the results of the sound absorbtion coefficients to look into the difference of results between reverberation room method and impedance tube method. Also we compared the results of the sound absorbtion coefficients with respect to the size of sample and the volume of reverberation room. From the experiment, we could see that the sound absorbtion coefficients are measured equally for different sample size. But the sound absorbtion coefficients are measured differently according to test methods and test conditions.

NYCDOT2008 기준을 이용한 국내 지반의 지반분류방법 결정 (Determination of Site Classification Method in the Korean Peninsula Based On NYCDOT2008(2008 New York City DOT Seismic Design Guidelines))

  • 강호덕;김기상;선창국;김명모
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.777-784
    • /
    • 2010
  • In the current Korean seismic design guide, the site classification and the corresponding site coefficients were determined based on the UBC-1997 (Uniform Building Code). In order to develop the current site classification system, it is important to compare the local site conditions in Korea to other countries which have similar seismic design guides. In the eastern United States, New York City(40degrees 45minutes north latitude, 73degrees 59minutes west longitude) suggested that current design guidelines are unsuitable to shallow bedrock depth sites. So the 3-parameter methods are performed for new criteria in New York City. In this study, site response analyses were performed at 181 study sites using one-dimensional equivalent linear to evaluate the site-specific earthquake ground motions at inland areas in the Korean peninsula and reclassify the results according to similar ground motions using the 3-parameter methods. It is effective that multi-parameter methods for Korean site characteristics in comparison with single parameter method.

  • PDF

역사 지진 피해 발생 읍성 지역의 부지 응답 특성 평가 (Estimation of Site Response Characteristics at Town Fortress Areas Damaged by Historical Earthquakes)

  • 선창국;방은석;정충기;김동수
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.125-132
    • /
    • 2006
  • To estimate the local site effects at two town fortress areas where stone parapets were collapsed during historical earthquakes, site characteristics were evaluated using borehole drillings and seismic tests and equivalent-linear site response analyses were conducted based on the shear wave velocity (Vs) profiles determined from site investigations. The study sites are categorized as site classes C and B according to the mean Vs to 30 m ranging from 500 to 850 m/s, and their site periods are distributed in short period range of 0.06 to 0.16 sec. For site class C in the study areas, the short-period (0.1-0.5 sec) and mid-period (0.4-2.0 sec) site coefficients, $F_{\alpha}$ and $F_\nu$ specified in the Korean seismic design guide, underestimate the ground motion in short-period band and overestimate the ground motion in mid-period band, respectively, due to the characteristics showing high amplification in short period range, which can result in the collapse of stone parapets having the short natural period.

  • PDF

도시대기측정망 자료를 이용한 대구지역 대기오염물질의 공간분포에 관한 연구 (A Study for Spatial Distribution of Principal Pollutants in Daegu Area Using Air Pollution Monitoring Network Data)

  • 주재희;황인조
    • 한국대기환경학회지
    • /
    • 제27권5호
    • /
    • pp.545-557
    • /
    • 2011
  • The objective of this study was to estimate the trends of each pollutant using the air pollution monitoring networks data from January 2005 to December 2008 in Daegu area. Also, the spatial characteristics of each pollutant were determined using the Pearson correlation coefficients and COD (coefficients of divergence). In this study, the trends of hourly, monthly, seasonal, and total average concentrations of each pollutant for the 10 sites were analyzed. The Ihyeon site showed highest concentration for the $SO_2$, $NO_2$, and PM10}. In the case of $O_3$, the Jisan site showed highest concentration among the other sites. Also, industrial area presented highest concentration for the $SO_2$, CO, and PM10. On the other hand, $NO_2$ showed highest in commercial area. The IDW (inverse distance weighting) method was used to estimate characteristics of spatial distribution. The results provide identify spatial distribution for each pollutant. Also, the Pearson correlation coefficients and COD values provide spatial variability among the monitoring sites. The COD of each pollutant showed very low values for all of the sites pairs. On the other hand, the Pearson correlation coefficients showed high values for all of the sites pairs. Finally, analysis of spatial variability can be used to characterize the spatial uniformity and similarity of concentrations from each pollutant.