• Title/Summary/Keyword: Sinusoidal gratings

Search Result 10, Processing Time 0.019 seconds

Visual Measurement of Rotational Displacements by Using Two Different Moire Fringes Simultaneously Generated by Repeated Sinusoidal Gratings (반복사인격자에서 동시에 생기는 두 가지 무아레 무늬를 이용한 회전변위의 가시적 측정)

  • Jeong, Youn-Hong;Oh, Jeong-Hyo;Jo, Jae-Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.4
    • /
    • pp.302-309
    • /
    • 2008
  • We present the precise visual measurement method of rotational displacements using two different moire fringes simultaneously generated by repeated sinusoidal gratings. We investigate the variation of moire fringes depending on rotational displacements through computer simulation and experiment using a rotator in detail. The moire fringes are composed of the wide linear fringe part with a long period and the narrow linear fringe part with a short period. These parts are superior to the angle detection of more than 12 degrees and less than 12 degree, respectively. Additionally, the method can be visually used in the determination of the rotational direction by observing the moire fringe's direction.

High-Density Quantum Nanostructure for Single Mode Distributed Feedback Semiconductor Lasers by One-Step Growth (단일 공정에 의한 고효율 단일모드 반도체 레이저 구조 제작을 위한 고밀도 양자 나노구조 형성)

  • Son, Chang-Sik;Baek, Jong-Hyeob;Kim, Seong-Il;Park, Young-Ju;Kim, Yong-Tae;Choi, Hoon-Sang;Choi, In-Hoon
    • Korean Journal of Materials Research
    • /
    • v.13 no.8
    • /
    • pp.485-490
    • /
    • 2003
  • We have developed a new way of the constant growth technique to maintain a grating height of originally-etched V-groove of submicron gratings up to 1.5 $\mu\textrm{m}$ thickness by a low pressure metalorganic chemical vapor deposition. The constant growth technique is well performed on two kinds of submicron gratings that made by holography and electron (e)-beam lithography GaAs buffer layer grown on thermally deformed submicron gratings has an important role in recovering the deformed grating profile from sinusoidal to V-shaped by reducing mass transport effects. The thermal deformation effect on submicron gratings made by e-beam lithography is less than that on submicron gratings made by holography. The constant growth technique is an important step to realize complex optoelectronic devices such as one-step grown distributed feedback lasers and two-dimensional photonic crystals.

Analysis of Reconstructed Images of Computer Generated Hologram Formed according to Grating Modulation Methods (회절격자의 변조방식에 따라 형성된 CGH의 재생 영상 분석)

  • Jeong, Man-Ho
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.5
    • /
    • pp.360-364
    • /
    • 2008
  • The diffraction efficiencies of gratings are affected by the inner structure which is determined by modulation type. CGH (Computer generated Hologram) basically uses the principles of a diffraction grating. As like as the diffraction gratings the patterns recorded in the CGH are different according to modulation methods which result in the performances of the reconstructed images. In this paper, on this fact CGHs are recorded according to sinusoidal and rectangular modulation methods and the characteristics of reconstructed images are analyzed. Also the reconstruction performances of the amplitude and phase, phase-only and binary phase CGH are analyzed.

Research on a New Vision Test Chart Measuring Visual and Spatial Sense of Moire Fringes (무아레 무늬의 시각적 공간감각을 측정하는 시표로서의 가능성 조사)

  • Woo, Hyun Kyung;Lee, Seongjae;Jeong, Youn Hong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.241-245
    • /
    • 2010
  • Purpose: In this work we suggested a grating chart of vision test which could be used to measure the sense of distance and motion of object. Methods: A couple of gratings with periodic structure were fabricated. Through a lens the grating images showing geometrical shapes were projected on a vision test chart in order to form a new grating chart of vision test. In rotating and translating the gratings the examinee perceived the variation of position of gratings by the variation of the sense of distance and motion. Results: The results of the sense of distance and motion measured in rotating and translating the gratings showed the average errors of ~2.98% and ~1.73% at $\theta=15^{\circ}$ respectively compared to calculated values. Conclusions: The grating chart of vision test suggested in this work can be used as a new test chart that lets an examinee perceive a sense of distance and motion of object.

Ray-optical determination of the coupling coefficients of waveguide gratings by use of the rigorous coupled wave theory (회절격자구조를 갖는 도파로 소자의 엄밀한 광선광학적 결합계수 계산)

  • 박선택;송석호;오차환;김필수
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.4
    • /
    • pp.348-353
    • /
    • 1999
  • Ray-optics approach based on the rigorous coupled wave theory, called by the rigorous ray-optics method (RROM), is developed for the calculation of couling coefficients of waveguide grating devices. The coupling coefficients of several grating structures, such as rectangular, sinusoidal, triangle, and trapezoidal shapes, are determined by the RROM, and they are compared with those obtained by conventional methods of the ray-optics method (ROM) and the coupled mode method (CMM). In the case of rectangular gratings, the coupling coefficients is evaluated in detail by various depths and duty-cycles of the grating. We have found that the RROM gives more exact solutions for the coupling coefficients of even arbitrary shapes of diffractive waveguide grating devices than the other conventional methods.

  • PDF

MTF comparision of CCD camera measured by two methods: Twyman-Green interferometer method and zoom lens method with three sinusoidal gratings (트와이만-그린 간섭계를 이용한 CCD의 MTF 값과 줌 렌즈를 이용한 CCD의 MTF 값 측정 비교.)

  • 홍성목;조재흥;임천석;이윤우;이회윤
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.28-29
    • /
    • 2003
  • 각종 렌즈 및 카메라, 망원경, 현미경 등 다양한 광학계들이 설계 및 개발 되고 있는 시점에서 그 성능을 정확하게 평가하는 것이 매우 중요하다. 광학계의 성능 평가를 위해서는 크게 정성적인 방법과 정량적인 방법으로 나눌 수 있는데, 정성적인 방법에 의한 평가는 분해능 표판이나 주기적인 격자의 상을 스크린 등에 결상시킨 후 사람의 눈을 통해서 한계 분해능을 평가하는 방법이다. 정량적인 방법에 의한 평가는 OTF(Optical Transfer Function)를 측정하거나 설계 자료를 통해 계산해 내는 것이다. (중략)

  • PDF

Acceleration Sensor Using Optical Fibers and Film Gratings (광섬유와 필름격자를 이용한 가속도 센서)

  • Lee, Youn-Jea;Jo, Jae-Heung;Kwon, Il-Bum;Seo, Dae-Cheol;Lee, Nam-Kwon
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.3
    • /
    • pp.175-181
    • /
    • 2008
  • We develop a fiber optic acceleration sensor with LED, PD, POF, and a cantilever beam, having film grating at the edge of the beam. Light is transmitted from LED to PD through the film grating. When the cantilever beam moves by external vibration, output light is modulated as sinusoidal signals. The characteristics of output signals are dominated by the spacing of the film grating and also by the size and the elasticity of the beam. Two output signals, having constant initial phase difference, are obtained by two gratings with 90 degree phase difference. Those two signals are used to determine phase angle, which is proportional to the displacement of the beam. Finally, the acceleration is determined from conversion equation between displacement and acceleration. This sensor is designed for monitoring the vibration of large and complex building in the low frequency range of below 7 Hz, and is particularly suitable to measure acceleration in electromagnetic environments.

Study on Physiological Summation in Peripheral Retina for Eccentric Viewing Training (중심외주시 훈련용 주변부 망막의 생리적 가중에 관한 연구)

  • Seo, Jae-Myoung;Lee, Ki-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.489-493
    • /
    • 2013
  • Purpose: This study was to investigate peripheral vision and provide people with macular degeneration with a guideline for eccentric viewing training. Methods: 30 adult subjects with normal vision took part in this study. The lateral area of $20^{\circ}$ eccentricity from the fovea of right eye was only used to measure the physiological summation. The target was sinusoidal vertical gratings within a circular aperture. The critical points in spatial and temporal summation was found to compare each other for 0.7 cpd and 3.0 cpd, respectively. Results: Critical duration and contrast sensitivity for 0.7 cpd were 540 ms and 1.1, and 315 ms and 0.98 for 3.0 cpd respectively. The critical degrees and contrast sensitivity for 0.7 cpd were $11.3^{\circ}$ and 2.8, and $5^{\circ}$ and 2.63 for 3.0 cpd respectively. Conclusions: The critical point in peripheral vision reaches relatively faster than the one in central vision. It is recommended to train the peripheral retina under the lower spatial frequency more frequently for a short time than constantly for a long time.

Analysis of the Visual Function in low Vision Patients and Normals in Canada, Using Contrast Sensitivity (대비감도를 사용한 캐나나 내 저시력 환자와 정상인의 시기능 분석)

  • Seo, Jae Myung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.83-88
    • /
    • 2009
  • Purpose: It is said that persons with low vision (LV) require larger object and longer exposure time to make a visual judgment. The spatial summation stands for the increasing of contrast sensitivity (CS), as the target size is enlarged. Likewise, the term temporal summation is used when the CS increases as the exposure duration is extended. The present study investigates whether or not greater target and longer exposure duration is required for LV subjects than for control subjects. Methods: Twenty subjects with LV and twenty age-matched controls took part in the study. The CS was measured with a 2 alternative forced choice stair case for 0.7 and 3.0 cycle per degree (c/d) static sinusoidal gratings within a circular aperture. The results were analyzed by mixed ANOVA (2${\times}$2). Results: As expected, the CS in the LV group were overall depressed. For spatial summation, mixed ANOVA (2 groups${\times}$2 spatial frequencies) gave p values of 0.13 for the effect of group, 0.14 for spatial frequency and there was no interaction (p=0.59). Similarly, for temporal summation the results were p=0.19 for group, 0.31 for spatial frequency and p=0.95 for interaction. Conclusions: Despite the depression of CS in the LV group, a significant difference for spatial and temporal summation between two subject groups was not reached.

  • PDF