• Title/Summary/Keyword: Single phase

Search Result 5,349, Processing Time 0.045 seconds

Speed Control for Single Phase Induction Motor Using Phase Angle (위상각제어에 의한 단상유도전동기의 속도제어)

  • 임영철;김광헌;최찬학;나석환;정영국;장영학;장학충
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.5
    • /
    • pp.41-50
    • /
    • 1995
  • Single-phase induction motors are widely used in many light duty applications, especially in home and office. many applications which use these motors require adjustable speed control continuously. In general, the speed control of single-phase induction motor is accomplished at a few discrete speeds by using tapped-windings, pole switching or gear. These techniques are inefficient and complicated. In this paper, Torque controller which adjusts a generating torque using phase difference between main winding voltage and auxiliary winding voltage is proposed. The analysis includes the determination of the relationship between the auxiliary winding voltage is proposed. The analysis includes the determination of the relationship between the auxiliary winding voltage phase angle and torque. Simulation results of the torque-speed characteristics using the controlled auxiliary winding supply are shown and discussed. and the drive is tested experimentally to verify the results of the theory by using a dynamometer.

  • PDF

Definition of Powers and Power Quality Factors at a Point of Common Coupling in Single-Phase Systems and Three-Phase Systems

  • Kim, Hyosung;Frede Blaabjerg;Jensen, Birgitte-Bak
    • Journal of Power Electronics
    • /
    • v.2 no.1
    • /
    • pp.32-45
    • /
    • 2002
  • This paper proposes an unified definition of powers for various circuit conditions such as balanced/unbalanced, sinusoidal/non-sinusoidal, and linear/nonlinear, fur single-phase systems and three-phase systems. Conventional reactive power is more classified into an interactive power and an alternating power. These powers are defined both in the time domain and the frequency domain consistently, and agree well with the conservation law. Several important power quality factors are defined to measure and evaluate the power quality fur the various circuits in the single-phase and three-phase systems. Simulation results show the power quality factors can evaluate and classify the various circuit conditions clearly.

The Torque Characteristics Analysis of the Single-Phase Switched Reluctance Motor According to the Starting Method (기동 방법에 따른 단상 SRM의 토크 특성 해석)

  • Kim, Jun-Ho;Kim, IL-Jung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.9
    • /
    • pp.40-46
    • /
    • 2012
  • The single-phase switched reluctance motor(SRM) has only one inductance variation and the positive torque is generated in the restricted section. So, it cannot be started by itself. To solve this problem, many researchers have addressed the several starting method for the single-phase SRM. This paper is focused on the torque characteristics of the single-phase SRM according to starting method. The four major starting method - permanent magnet, saturable stator pole, to grade the rotor, stepped rotor pole - is selected to analyze the torque characteristics. The analysis model of each starting method is designed to changed the pole shape or inserting other material in the basic model. The torque characteristics of each analysis model is obtained by using FEM analysis. The FEM analysis is performed at incremental rotor positions over half inductance cycle in any one pole with 250AT, 500AT, 750AT. The distortion factor of each analysis model is analyzed through the FFT to compare the distortion between basic model and four analysis model.

Air-Water Two-Phase Flow Test Facility of a Single Stage Closed-type Centrifugal Pump (단단 밀폐형 원심펌프의 기액이상류 성능시험 설비)

  • Kim, S. Y.;Lee, S. L.;Kim, Y. T.;Kim, S. D.;Lee, Y. S.;Lee, Y. H.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.49-53
    • /
    • 2004
  • LabVIEW is mostly preferred to use in experiment, measurement and control as one of the useful thing in America and Europe. So, We tried performance experiment of a single-stage closed-type centrifugal pump by using the LabVIEW. The pump rpm and the shaft torque are measured by rpm sensor and torque sensor The test pump's maximum rpm, head, kW are 1,750, 13m, and 1.5kW, respectively The casing is made up with transparency acrylic for confirmation the flow patterns. We installed experimental equipment for air water two phase flow. This paper tries to analyze the single-phase flow characteristics through this air water two phase flow experimental apparatus. The performance results of a single-stage closed-type centrifugal pump satisfied reappearance and coincide well with head and coefficients according to the change of rpm.

  • PDF

Characteristics of Utility Transformer on Household Single-Phase ESS-PCS According to LC Filter Location (주택용 단상 ESS-PCS의 LC 필터위치에 따른 상용변압기의 특성)

  • Kim, Yong-Jung;Kim, Hyosung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.2
    • /
    • pp.101-105
    • /
    • 2018
  • Shortage of electric power occurs frequently along with increased electric power demand. ESS is a precaution to solve this issue. Household ESS has a capacity of approximately 3 kW/7 kWh. Household ESS batteries are typically designed with nominal voltages between 40 and 50 V. To connect household ESS with a 220 V AC system, low battery voltages in power conditioning system (PCS) should be boosted. To boost low battery voltage and match it with AC grid voltage, the use of a transformer for a commercial frequency can be considered. To attenuate switching harmonics of the household single-phase ESS-PCS, LC filter can be installed in two positions: on the primary side or on the secondary side of a transformer. A method has been used generally in single-phase inverters for the ESS-PCS. In another method, however, the output efficiency of the ESS-PCS may be decreased. Parasitic components of the transformer can affect voltage losses, when the square wave with the switching frequency in the ESS-PCS is passed through the transformer windings. In this work, the characteristics of the transformer according to the position of an LC filter are investigated for household single-phase ESS-PCS.

A Study on the Design of Single Phase LSPM Considering the Irreversible Demagnetization of Permanent Magnet (불가역 감자를 고려한 단상 LSPM 설계에 관한 연구)

  • Jung, Dae-Sung;Go, Sung-Chul;Park, Hyun-June;Kwon, Sam-Young;Lee, Hyung-Woo;Lee, Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2186-2193
    • /
    • 2008
  • The growth on consideration of energy savings and motor efficiency has caused the LSPM(Line Start Permanent Magnet Motor) to be focused as a substitute for conventional induction motors. A Line start permanent magnet motor able to be driven at synchronous speed is designed based on a single phase induction motor in this paper. The single phase LSPM is identical to the induction motor except a permanent magnet is installed in the rotor. As the permanent magnet influences the characteristics of both transient state and steady state, a design considering both starting and synchronization conditions was used. In this paper, by adopting DOE, a single phase motor has been designed showing high power and smooth start. Also, optimal model is selected by weighting function. And the characteristics demagnetization are analyzed according to the variation of magnet shape. Finally, to verify the design results, a prototype was measured.

A Study on Driving Algorithm of Single-phase PMSM based on Proportional Resonant Current Controller (비례공진 전류제어기 기반의 단상 영구자석 동기전동기 운전에 관한 연구)

  • Seong, Uiseok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.1
    • /
    • pp.115-120
    • /
    • 2021
  • In this paper, an operating algorithm for single-phase permanent magnet synchronous motor based on PR current controller is proposed. In general, an asymmetric gap may occur depending on the shape of the rotor of single-phase PMSM, and this causes noise and vibration during high-speed operation. Therefore, in this paper, an operating algorithm for a single-phase PMSM usihng a proportional resonant current conrtoller with excellent control stability was proposed. Proportional resonant current controller has on steady state error is relatevly robust against distortion. Also, steady state error of AC input can be eleminated without complicated calculation process. The validity and availability of the proposed algorithm are verified through the experiment.

A Performance Comparison of the Current Feedback Schemes with a New Single Current Sensor Technique for Single-Phase Full-Bridge Inverters

  • Choe, Jung-Muk;Lee, Young-Jin;Cho, Younghoon;Choe, Gyu-Ha
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.621-630
    • /
    • 2016
  • In this paper, a single current sensor technique (SCST) is proposed for single-phase full-bridge inverters. The proposed SCST measures the currents of multiple branches at the same time, and reconstructs the average inductor, capacitor, and load current in a single switching cycle. Since all of the branches' current in the LC filter and the load are obtained using the SCST, both the inductor and the capacitor current feedback schemes can be selectively applied while taking advantages of each other. This paper also analyzes both of the current feedback schemes from the view point of the closed-loop output impedance. The proposed SCST and the analysis in this paper are verified through experiments on a 3kVA single-phase uninterruptible power supply (UPS).

Analysis of Fault Current limiting Characteristics According to Fault Type in Integrated Three-Phase Flux-Lock Type Superconducting Fault Current limiting (사고종류에 따른 삼상 일체화된 자속구속형 SFCL의 사고전류제한특성 분석)

  • Park, Chung-Ryul;Lim, Sung-Hun;Park, Hyoung-Min;Cho, Yong-Sun;Choi, Hyo-Sang;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.54-56
    • /
    • 2005
  • In this paper, we investigated the quench characteristics of HTSC elements in the integrated three-phase flux-lock type SFCL according to fault types such as the single-line-to-ground fault, the double-line-to-ground fault, the line-to-line fault and the three-line-to-ground fault. The integrated three-phase flux-lock type SFCL was the upgrade version of the single-phase flux-lock type SFCL. The structure of the integrated three-phase flux-lock type SFCL consisted of three-phase flux-lock reactor wound on an iron core with the ratio of the same turn between coil 1 and coil 2 in each phase. When the SFCL is operated under the normal condition, the flux generated in the iron core is zero because the flux generated between two coils of each single phase is canceled out. Therefore, the SFCL's impedance is zero, and the SFCL has negligible influence on the power system. However, if a fault occurs in any single-phase among three phases, the flux generated in the iron core is not zero any more. The flux makes HTSC elements of all phases quench irrespective of the fault type, which reduces the current of fault phase as well as the current of sound phase. It was observed that the fault current limiting characteristics of the suggested SFCL were dependent on the quench characteristics of HTSC elements in all three phases.

  • PDF

Reduction of DC-link Capacitance for Single-Phase Transformerless Photovoltaic Power Converters (절연형 단상 태양광 PCS의 직류링크 커패시터 저감)

  • Nguyen, Hoang Vu;Lee, Dong-Choon
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.365-366
    • /
    • 2016
  • This paper presents a single-phase transformerless photovoltaic (PV) power converter systems based on the AC/DC boost inverter, which is capable of solving the leakage current and second-order ripple power issues. By eliminating the inherent ripple power in single-phase inverter, the bulky electrolytic capacitor can be replaced by a small film capacitor. The validity of the proposed scheme has been verified by the simulation results.

  • PDF