• Title/Summary/Keyword: Single panel

Search Result 437, Processing Time 0.033 seconds

Comparison of Sound Transmission Loss Through Single and Double with Vacuum Layer Polymer Soundproof Panel (단일 구조 및 진공층이 있는 이중 구조 폴리머 방음패널의 음향투과손실 비교)

  • Lee, Ju Haeng;Kim, Ilho;Ahn, Kwang ho
    • International Journal of Highway Engineering
    • /
    • v.15 no.6
    • /
    • pp.11-15
    • /
    • 2013
  • PURPOSES : This study is to compare sound transmission loss(STL) value depending on the four kinds of materials, PC(Polycarbonate), PMMA(Polymethyl mathacrylate), PE(Polyethlyene), PP(Polypropylene), and two types of structure, single layer and double with vacuum layer, of soundproof panel. METHODS : With four sorts of polymer material, the specimens were made as various structures, 4 mm and 8 mm of single soundpoof panel and vacuum layered 4 mm of one. The experimental condition and procedures were complied with authorized process test, KS F 2808. RESULTS : STL of single panel made of PC were the greatest followed by PMMA, PE, PP regardless of the thickness of panel, However, STL of PMMA panel began to decrease around 2500 Hz and reached the lowest value among others in 5000 Hz. Vacuum layer soundproof panel showed good performance in more than 2000 Hz. Only vacuum layer panel made of PC presented resonance frequency at 800 Hz while that of other vacuum ones at 1000 Hz. CONCLUSIONS : According to results of single layer, it was found that single panel functioned as the theorical way we expected in terms of surface density. That trends were blurred as the panel got thicker. And it was suggested also that vacuum layer panel performed well at high frequency, more than 2000 Hz.

Prediction of Sound Transmission through Single Lightweight Concrete Panel (단일 경량콘크리트판넬의 차음성능 예측)

  • Yang, Hong-Seok;An, Ji-Hyeong;Kim, Myung-Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.56-60
    • /
    • 2007
  • Nowadays shear wall structural system is gradually changing to framed structure. For this reason, lightweight panel is increasingly being used as separating walls. One of design methods to obtain high transmission loss is double panel. To predict the acoustic performance of double panel, prediction of transmission loss of single panel must be performed, previously. In this study, the predicted values for four single panels were compared with the measured values. The result shows the arithmetical average deviations(100Hz to 3150Hz) between the predicted and measured transmission loss were in range between 1.1dB and 3.9dB. The predicted values were generally lower than measured values above critical frequency. The single-number quantities, $R_W+C$, were predicted in range between 36dB to 38dB, and the differences of single-number quantities between the predicted and measured value were within 1dB.

  • PDF

Men's Single-layered $Chog{\breve{a}}ri$ in Joseon Dynastry -Focused on SongHyosang(1430-1490), SongHeejong(the late 1500s) tombs - (조선시대 남성 분묘 출토 적삼 고찰 - 송효상(宋效商, 1430-1490), 송희종(宋喜從, 16C중후반)묘 출토 복식을 중심으로 -)

  • Kweon, Jun-Hee;Kweon, Young-Suk
    • Journal of the Korean Society of Costume
    • /
    • v.59 no.3
    • /
    • pp.131-144
    • /
    • 2009
  • This study is about single-layered $Chog{\breve{a}}ri$ excavated from SongHyosang(宋效商, 1430-1490, SHS hereafter), SongHeeJong(宋喜從, the late 1500s, SHJ hereafter) tombs. There are 7 single-layered $Chog{\breve{a}}ris$ for men. We focus on comparison of their design and sowing method. 1. Design: Investigating collar, $Chog{\breve{a}}ris$ from SHS have MokpanGit and $Chog{\breve{a}}ris$ from SHJ have KalGit. KalGit has been seen from SHJ to 17th, 18th and 19th centuries. After the late 1500s, there is no MokpanGit single-laTered $Chog{\breve{a}}ri$ for men. Side panel under arm has various shapes(triangle, trapezoid, triangle+trapezoid) in 15th century. After the late 1500s, It changes into no side panel. Two $Chog{\breve{a}}ris$ with no side panel from SHJ reveals that the late 1500s is a period of transition. 2. Sewing method: First, researching lengthwise grainline of the fly, the left fly has lengthwise grainline outside In four, inside in three. The right fly has lengthwise grainline outside in just one, the others have lengthwise grainline inside. Compared with today's way, there is a great difference, but in those times there isn't an established rule. This is true of side panel under arm. The sewing method are backstitch, running stitch, and hemming. Researching the construction method of seam, in putting two selvages together, open seam and plain seam are used. In putting selvage and bias, bias and bias together, flat felled seam and french seam are used. This study shows that single-layered $Chog{\breve{a}}ri$ far men from 15C. to 16C. has changes of design such as collar(Git) and side panel undo. arm. But there is little change in sewing method.

Development of a Single Tangle Net for the Brown Shrimp by Observation of Entanglement Behaviour

  • Kim Yong-Hae
    • Fisheries and Aquatic Sciences
    • /
    • v.6 no.1
    • /
    • pp.34-40
    • /
    • 2003
  • Three panel trammel nets were made illegal for the brown shrimp (Penaeus japonicus) or fishes by Korean fisheries law while trammel nets for fleshy prawn in the West sea remained legal. In this study a single panel tangle net with vertical loop lines rigged between the float line and sinker line was specially designed to catch brown shrimp. This net was developed for the first time after observation of the brown shrimp behaviour when reacting to a net in an observation tank. In field experiments these single tangle nets were compared with the traditional trammel nets in the coastal waters of the Keoje area. The mean number of the brown shrimp for 53 fishing operations was 1.13 per unit panel of the single tangle nets when fitted with the vertical loop lines. This was $84\%$ of the mean catch of 1.36 achieved with the trammel nets. These results of fishing experiments using single tangle nets in the field revealed a high fishing efficiency for the brown shrimp and showed little difference from trammel nets. The size of the brown shrimp or number of by-catch was not different between single tangle nets and trammel nets.

Sound Quality Enhancement by using the Single Core Exciter in OLED Panel

  • Lee, Sungtae;Park, Kwanho;Park, Hyungwoo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.2
    • /
    • pp.871-888
    • /
    • 2020
  • With the development of display engineering and technology, the screen and sound quality of information devices such as TVs are improving. The screen used LEDs via LCD and PDP and a large flat panel in the early CRT to create super-high resolution. The sound is improved by directly vibrating a thin and simple panel, such as an OLED. In our previous study, the exciter speaker was attached to the rear of the OLED panel to be used as the diaphragm of the speaker, and the sound quality was as good as that of the TV using the existing dynamic speaker. This method supplied the viewer with the direct sound coming from the panel, delivering clear sound, and the sound and image came from the same location, thus giving the viewer high immersion and maximizing the effect of information transfer. OLED exciter speakers, however, have a special directivity, which tends to slightly attenuate the tone at the very center of the screen. This study improves the sound quality by improving the structure of the exciter speaker and the radiated sound of the flat panel display. A 2-in-1 Exciter is made into a single core to improve the speaker's radiation pattern.

A High Speed Address Recovery Technique for Single-Scan Plasma Display Panel(PDP) (Single-Scan Plasma Display Panel(PDP)를 위한 고속 어드레스 에너지 회수 기법)

  • Lee, Jun-Young
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.239-242
    • /
    • 2005
  • A high speed address recovery technique for AC plasma display Panel(PDP) is proposed. By removing the GND switching operation, the recovery speed can be increased and switching loss due to GND switch also becomes to be reduced. The proposed method is able to perform load-adaptive operation by controlling the voltage level of energy recovery capacitor, which prevents increasing inefficient power consumption caused by circuit loss during recovery operation. Thus, the technique shows the minimum address power consumption according to various displayed images, different from Prior methods operating in fixed mode regardless of images. Test results with 50" HD single-scan PDP(resolution = 1366$\times$768) show that less than 350ns of recovery time is successfully accomplished and about 54% of the maximum power consumption can be reduced, tracing minimum power consumption curves.

  • PDF

Comparative study on one and two-path single energy recovery circuit for plasma display panel (PDP)

  • Yi, Kang-Hyun;Choi, Seong-Wook;Moon, Gun-Woo;Park, Jung-Pil;Jung, Nam-Sung
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.256-259
    • /
    • 2006
  • Comparison of one two-path single energy recovery circuit for plasma display panel (PDP) is shown in this paper. A single energy recovery circuit (SERC) is proposed to reduce cost for manufacturing PDP and there are two ways, one and two-path, in driving this circuit. Compared with one-path SERC, there are low power consumption, low surge current and high performance in two-path SERC. The results will be shown with 42-inch HD panel.

  • PDF

A Study on Image Reversal Phenomenon of Three-Electrode Type Electronic Paper Display (3전극형 전자종이 디스플레이의 이미지 반전현상에 관한 연구)

  • Shin, Yong-Kwan;Kim, Young-Cho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.8
    • /
    • pp.524-530
    • /
    • 2015
  • We propose a three-electrode type electronic paper display and its fabrication process to realize single color at the same display panel. We establish a fabrication process with the mixing of electronic ink, loading of this ink, electronic ink assembly, packaging and driving. Also, we discuss an operating principle of this panel and the induced image reversal phenomenon by electric field area of the lower electrodes. This phenomenon is not occurred for the panel having $10{\mu}m$ electrode space. By this pixelation structure like this three-electronic paper display, a single color realization without color filter is possible and various kind of color is defined by a dye selection for charged particles and electrically neutral fluid.

A High Speed Address Recovery Technique for Single-Scan Plasma Display Panel(PDP) (Single-Scan Plasma Display Panel(PDP)를 위한 고속 어드레스 에너지 회수 기법)

  • Lee Jun-Young
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.9
    • /
    • pp.450-453
    • /
    • 2005
  • A high speed address recovery technique for AC plasma display panel(PDP) is proposed. Replacing GND switch by clamping diode. the recovery speed can be increased by saving GND hold-time and switching loss due to GND switch also becomes also be reduced. The proposed method is able to perform load-adaptive operation by controlling the voltage level of energy recovery capacitor, which prevents increasing inefficient power consumption caused by circuit loss during recovery operation. Test results with 50' HD single-scan PDP(resolution = 1366$\times$768) show that less than 3sons of recovery time is successfully accomplished and about$54\%$ of the maximum power consumption can be reduced, tracing minimum power consumption curves.