• 제목/요약/키워드: Single fracture

검색결과 654건 처리시간 0.023초

알루미늄 단순겹치기 접착이음의 에지계면균열에 대한 연구 (Analysis on the Interface Edge Crack in Aluminum Bonded Single Lap-joint)

  • 유영철;박정환;정의섭;이원
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.655-659
    • /
    • 1997
  • The analysis of cracks at the interface between dissimilar materilar has received a great deal of attention in recent years. In this paper we conducted the static tensile test for the aluminum bonded single lap-joint with the interface edge crack. Comparing this results, that is ultimate load and strain value of aluminum adherend by strain gauge with the fracture mechanics parameters, compliance and stress intensity factors acquied from the boundary element analysis, we concluded that there are critical value of crack length to provoke the interface fracture.

  • PDF

Fracture Toughness of 3Y-TZP Dental Ceramics by Using Vickers Indentation Fracture and SELNB Methods

  • Moradkhani, Alireza;Baharvandi, Hamidreza;Naserifar, Ali
    • 한국세라믹학회지
    • /
    • 제56권1호
    • /
    • pp.37-48
    • /
    • 2019
  • The objective of this research is to analyze the fracture toughness of pure and silica co-doped yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP) bioceramics containing 0.1 and 0.2 wt.% of alumina, and sintered at a temperature of $1500^{\circ}C$. Because of the relatively easy preparation of the test specimens and the high speed of testing, the Vickers indentation fracture (VIF) technique is more frequently used to evaluate the fracture toughness of biomaterials and hard biological tissues. The Young's modulus and hardness values were obtained by means of nanoindentation and indentation methods. The fracture toughness values of 3Y-TZP bioceramics were calculated and analyzed using 15 equations related to the VIF technique, and loadings of 49.03 and 196.13 N with a Vickers diamond. For validation, the results were compared with fracture toughness values obtained by the single-edge laser-notch beam (SELNB) method with an almost atomically sharp laser-machined initial notch.

입내 분산형 Al2O3/Ag 나노복합체의 제조와 특성 (Preparation and Properties of the Intra-type Al2O3Ag Nanocomposites)

  • 천승호;한인섭;히데오 아와지
    • 한국세라믹학회지
    • /
    • 제44권4호
    • /
    • pp.208-213
    • /
    • 2007
  • Alumina/silver ($Al_2O_3/Ag$) nanocomposites with Ag content up to 9 vol% were prepared from nanopowder by soaking method using ${\gamma}-Al_2O_3$ of needle type and spark plasma sintering (SPS). The mechanical properties of specimens were investigated three-point flexural strength and toughness as a function of the Ag contents. The maximum flexural strength of the alumina/silver nanocomposite was 850 MPa for the 1 vol% composite, and also higher than monolith alumina as about 800 MPa at 3, 5, and 7 vol% Ag contents. Fracture toughness by single edged V-notch beam (SEVNB) was $4.05MPa{\cdot}m^{1/2}$ for the 3 vol% composite and maintained about $4.00MPa{\cdot}m^{1/2}$ at 5, and 7 vol% Ag content. Microstructure of fracture surface for each fracture specimens was observed. Due to the inhibition effect of alumina grain growth, the average grain size of nanocomposites depends on the content of Ag nano particles. The fracture morphology of nanocomposite with dislocation (sub-grain boundary) by silver nano-particles of second phases in the alumina matrix also showed transgranular fracture-mode compare with intergranular of monolith alumina. Thermal conductivity of specimens at room temperature was about 40 W/mK for the 1 vol% Ag content.

원자로 냉각재배관 엘보우 및 서포트 스컷트용 (Fracture Resistance Characteristics of SA516-Gr.70 Steel Plate for RCS Piping Elbow and Support Skirt)

  • 손종동;임만배
    • 한국안전학회지
    • /
    • 제21권4호
    • /
    • pp.49-54
    • /
    • 2006
  • The evaluation of elastic-plastic fracture characteristic was investigated in ferrite steel SA 516- Gr70 used for reactor coolant piping elbow and support skirt of pressure vessels. This paper describes the effect of temperature on J-R curve characteristic of this material. The elastic-plastic fracture mechanics parameter J is obtained with unloading compliance method. The test method were analyzed according to ASTM E 813-89 and E 1152-89. Unloading compliance $J_{IC}$ tests were performed on 1 CT specimens at varied temperatures from $25^{\circ}C$ to about $400^{\circ}C$ using a high temperature extensometer. At all temperature, valid $J_{IC}$ measurements could be made and $J_{IC}$ decreased with increasing temperature. SEM fractography schematically illustrates microvoid initiation, growth and coalescence at the tip of a preexisting crack.

기하양상을 고려한 균열 내 투수계수 산정

  • 채병곤;;김용재
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 임시총회 및 추계학술발표회
    • /
    • pp.159-163
    • /
    • 2004
  • This study was conducted to calculate the permeability coefficient in a single fracture while taking the true fracture geometry into consideration. The fracture geometry was measured using the confocal laser scanning microscope (CLSM). The CLSM geometry data were used to reconstruct a fracture model for numerical analysis using a homogenization analysis (HA) method. The HA is a new type of perturbation theory developed to characterize the behavior of a micro-inhomogeneous material that involves periodic microstructures. The HA permeability was calculated based on the local geometry and local material properties (water viscosity in this case). The results show that the permeability coefficients do not follow the theoretical relationship of the cubic law.

  • PDF

$Al_2O_3$$Al_2O_3$ -$SiC_w$ 복합재료의 동적 및 정적 파괴인성에 관한 연구 (Dynamic and Quasi-Static Fracture Toughness of $Al_2O_3$ and $Al_2O_3$ Ceramic Matrix Composite Reinforced with Sic Whiskers)

  • 조경목;이성학;표성규;장영원
    • 한국세라믹학회지
    • /
    • 제27권4호
    • /
    • pp.457-464
    • /
    • 1990
  • This paper presents the influence of the loading rate on the room temperature fracture toughness of a brittle Al2O3 and a SiC whisker reinforced Al2O3 composite. Dynamic fracture toughness tests were conduced using compressive fatigue pre-cracked notched round bars loaded in tension to produce a stress intensity rate K1=106 MPa√m/sec. The experimental results show that for each loading rate the fracture toughness values obtained for the ceramic matrix composite are higher than the corresponding values for the single phase alumina. In addition, both the reinforced and unreinforced ceramic are singnificantly tougher under dynamic loading than static loading. This dynamic and quasi-static fracture initiation behaviro can be interpreted by identifying quantitatively the mode of fractuer initiation as a function of loading rate.

  • PDF

Application of Monitored Anesthesia Care Using Dexmedetomidine to Common Oral and Maxillofacial Trauma Cases

  • Lee, Deok-Won;Shin, Min Cheol;Hong, Sung ok
    • Journal of Korean Dental Science
    • /
    • 제10권2호
    • /
    • pp.82-86
    • /
    • 2017
  • Oral and maxillofacial surgery (OMFS) trauma cases are commonly treated under general anesthesia. The purpose of this case report is to introduce an alternative method of anesthesia in patients who refuse general anesthesia. A combination of dexmedetomidine and ketamine for sedation anesthesia in 3 frequent fracture types in the field of OMFS-Le Fort I fracture, mandibular fracture, and alveolar bone fracture-was used. Dexmedetomidine as the single agent has not shown stable success rates for invasive procedures. To overcome some of the pitfalls with dexmedetomidine, combination sedation using ketamine was performed. Visual analogue scale scores were recorded postoperatively. Dexmedetomidine combined with ketamine administration provided safe and effective sedation and anxiolysis for surgical reduction and internal fixation of OMFS fractures. It showed advantages of decreased admission time, reduced expenses, minimal pain, and reduced anesthetic burden for the patient thus ultimately increasing overall satisfaction.

불용성 골감소증을 동반한 손목골절환자의 각변형에 대한 증례 보고 (Korean Medicine Treatments for the Angular Deformity of Wrist Fracture with Disuse Osteopenia: A Case Report)

  • 오명진
    • Korean Journal of Acupuncture
    • /
    • 제35권4호
    • /
    • pp.234-238
    • /
    • 2018
  • Objectives : This report details on a single case of Korean Medical treatments for the angular deformity of wrist fracture with disuse osteopenia. Methods : A 74-year-old lady with angular deformity of wrist fracture with disuse osteopenia was treated by Korean Medical therapies including manual acupuncture with electroacupuncture, pharmacopuncture, and chuna, twice daily for 41 days. Visual analogue scale for pain and range of motion were evaluated. Results : 1. Wrist pain decreased by Korean medical treatments over 41 days. 2. As a result of evaluation by visual analogue scale, the score marked from 6 to 3. 3. ROM of wrist joint increased from $0^{\circ}$ to $10^{\circ}$. Conclusions : Korean medical treatments helped symptom improvement in a patient with angular deformity of wrist fracture with disuse osteopenia.

An Anterior Approach to Entire Length of Humerus and to Distal Shaft for Fracture Fixation

  • Lee, Chul-Hyung;Choi, Hyun;Kim, Tae-In;Kim, Jun Beom;Shin, Sang Yeop;Rhee, Seung-Koo
    • Clinics in Shoulder and Elbow
    • /
    • 제19권4호
    • /
    • pp.223-228
    • /
    • 2016
  • Background: The aim of study was to confirm the clinical effectiveness and results of wide and single anterior approach for fractures occurring along length of humerus. Methods: A total of 23 patients with humeral fracture were enrolled into our study who were able to participate in at least one year of follow-up. Seven patients had segmental comminuted humeral fractures and 16 patients had distal humeral fractures. We made various tractions of the muscles to expose the proximal and the middle third humerus between the biceps and brachialis and the distal humerus by partial splitting of lateral side of biceps through a single incision. Postoperatively, we measured the Mayo elbow performance index (MEPI). Results: we achieved bone union in all 23 patients. Solid union of the bone was achieved at an average 13.9 weeks. Postoperatively, two complications were observed screw loosening and nonunion. Revision surgery was performed in both patients. The patient with bone nonunion was treated using bone grafts. No postoperative infections or peripheral neuropathies were observed. At the final follow-up (average 20 months), we found that the average MEPI functional score of the patients was 91.7 points regardless of the fracture site. Conclusions: Our whole humerus with a single incision was effective for the treatment of segmental comminuted and distal fractures. we believe it is a useful alternative to preexisting methods of fracture fixation.

지하 LPG 저장공동에 인접한 단일절리에서의 이상유체거동해석: I. 수치모형의 개발 및 모형실험 (Simulation of Two-Phase Fluid Flow in a Single Fracture Surrounding an Underground LPG Storage Cavern: I. Numerical Model Development and Parallel Plate Test)

  • 한일영;서일원
    • 한국수자원학회논문집
    • /
    • 제34권5호
    • /
    • pp.439-448
    • /
    • 2001
  • 본 연구에서는 단일절리에서 2상유체 동시거동을 해석하기 위해서 2차원 유한차분 수치모형을 개발하였다. 개발된 모형은 압력에 따른 점성의 변화가 포화도에 따른 상대투과계수의 변화를 절리간극의 크기별로 고려할 수 있다. 수치기법으로는 IMPES해법을 적용하여 물과 가스의 압력변화량과 포화도를 차례로 구하였다. 개발된 수치 모형에 이용할 상대투과계수의 특성식 도출을 위해서 일곱가지 경우의 평판모형실험을 실시하였다. 실험으로부터 도출된 상대투과계수 특성곡선은 기존의 경험식으로는 표현되기 어려웠으며, 따라서 새로운 경험식으로 로지스틱 방정식을 제시하였다. 이 방정식은 간극의 크기가 포함된 매개변수를 사용하였기 때문에 임의의 절리 간극크기의 적용이 가능한 형태이다.

  • PDF