• Title/Summary/Keyword: Single fracture

Search Result 654, Processing Time 0.021 seconds

Numerical Study on the Reduction of Blast-induced Damage Zone (최외곽공 주변암반의 발파굴착 손상영역 저감에 관한 수치해석적 연구)

  • Park, Se-Woong;Oh, Se-Wook;Min, Gyeong-Jo;Fukuda, Daisuke;Cho, Sang-Ho
    • Explosives and Blasting
    • /
    • v.37 no.3
    • /
    • pp.25-33
    • /
    • 2019
  • Controlling the blast-induced damage zone(BDZ) in mining excavation is a significant issue for the safety of employees and the maintenance of facilities. Numerous studies have been conducted to accurately predict the BDZ in underground mining. This study employed the dynamic fracture process analysis (DFPA) to estimate the BDZ from a single hole blasting. The estimated BDZ were compared with the results obtained by Swedish empirical equation. The DFPA was also used to investigate the control mechanism of BDZ and fracture plane formation around perimeter holes for underground mining blasting.

Surgical extrusion of a maxillary premolar after orthodontic extrusion: a retrospective study

  • Choi, Yong-Hoon;Lee, Hyo-Jung
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.45 no.5
    • /
    • pp.254-259
    • /
    • 2019
  • Objectives: Crown-root fracture and cervical caries in maxillary premolars constitute a challenge in cases of subgingival placement of restoration margins. Surgical extrusion has been practiced successfully in permanent anterior teeth. The aim of the present retrospective study was to assess the clinical outcome of surgical extrusion after orthodontic extrusion in maxillary premolars. Materials and Methods: Twenty-one single, tapered root maxillary premolars with subgingival crown-root fracture or caries were included. Presurgical orthodontic extrusion was performed on all teeth to prevent root resorption. Extent of extrusion and rotation was determined based on crown/root ratio. The postoperative splinting period was 7 to 14 days. Clinical and radiographic examination was performed at an interval of 1, 2, and 3 months. Results: After the mean follow-up of $41.9{\pm}15.2months$, failure was observed as increased mobility in 3 of 21 cases. No significant difference was observed in the outcome of surgical extrusion based on tooth type, age, sex, $180^{\circ}$ rotation, or time for extraction. Furthermore, marginal bone loss was not observed. Conclusion: Surgical extrusion of maxillary premolars can be a possible therapeutic option in cases of subgingival crown-root fracture.

Properties of Substrate Glass by Single ion Exchange Process (단일이온교환 공정에 따른 기판유리의 특성)

  • 이회관;이용수;강원호
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.9 no.3
    • /
    • pp.25-29
    • /
    • 2002
  • Single ion exchange process was used, and the ion exchange behavior and mechanical properties were investigated in substrate glass for flat panel display. In order to study the effects of ion exchange, ion exchange behavior with ion penetration depth, amount of ion exchange, density and thermal expansion was measured according to the time and temperature. The mechanical properties were evaluated by the three point bending test and curvature change, and then the fracture patterns were investigated by optical microscope.

  • PDF

A Study on the Nano-Deformation Behaviors of Single Crystal Silicon and Amorphous Borosilicate Considering the Mechanochemical Reaction (기계화학적 반응을 고려한 단결정 실리콘과 비정질 보로실리케이트의 나노 변형 거동에 관한 연구)

  • 윤성원;신용래;강충길
    • Transactions of Materials Processing
    • /
    • v.12 no.7
    • /
    • pp.623-630
    • /
    • 2003
  • Nanomachining process, static nanoplowing, is one of the most promising lithographic technologies in terms of the low cost of operation and variety of workable materials. In nanomachining process, chemical effects are more dominant factor compared with those by physical deformation or fracture. For example, during the nanoscratch on a silicon surface in the atmosphere, micro protuberances are formed due to the mechanochemical reaction between diamond tip and the surfaces. On the contrary, in case of chemically stable materials, such as ceramic or glass, surface protuberances are not formed. The purpose of this study is to understand effects of the mechanochemical reaction between tip and surfaces on deformation behaviors of hard-brittle materials. Nanometerscale elasoplastic deformation behavior of single crystal silicon (100) was characterized with micro protuberance phenomena, and compared with that of borosilicate (Pyrex glass 7740). In addition, effects of the silicon protuberances on nanoscratch test results were discussed.

Single-Stage Reconstruction with Titanium Mesh for Compound Comminuted Depressed Skull Fracture

  • Eom, Ki Seong
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.5
    • /
    • pp.631-639
    • /
    • 2020
  • Objective : Traditionally, staged surgery has been preferred in the treatment of compound comminuted depressed fracture (FCCD) after traumatic brain injury (TBI) and involves the removal of primarily damaged bone and subsequent cranioplasty. The main reason for delayed cranioplasty was to reduce the risk of infection-related complications. Here, the author performed immediate reconstruction using a titanium mesh in consecutive patients with FCCD after TBI, reported the surgical results, and reviewed previous studies. Methods : Nineteen consecutive patients who underwent single-stage reconstruction with titanium mesh for FCCD of the skull from April 2014 to June 2018 were retrospectively analyzed. The demographic and radiological characteristics of the patients with FCCD were investigated. The characteristics associated with surgery and outcome were also evaluated. Results : The frequency of TBI in men (94.7%) was significantly higher than that in women. Most FCCDs (73.7%) occurred during work, the rest were caused by traffic accidents. The mean interval between TBI and surgery was 7.0±3.9 hours. The median Glasgow coma scale score was 15 (range, 8-15) at admission and 15 (range, 10-15) at discharge. FCCD was frequently located in the frontal (57.9%) and parietal (31.6%) bones than in other regions. Of the patients with FCCDs in the frontal bone, 62.5% had paranasal sinus injury. There were five patients with fractures of orbital bone, and they were easily reconstructed using titanium mesh. These patients were cosmetically satisfied. Postoperatively, antibiotics were used for an average of 12.6 days. The mean hospital stay was 17.6±7.5 days (range, 8-33). There was no postoperative seizure or complications, such as infection. Conclusion : Immediate bony fragments replacement and reconstruction with reconstruction titanium mesh for FCCD did not increase infectious sequelae, even though FCCD involved sinus. This suggests that immediate single-stage reconstruction with titanium mesh for FCCD is a suitable surgical option with potential benefits in terms of cost-effectiveness, safety, and cosmetic and psychological outcomes.

Interfacial Evaluation of Single Ramie and Kenaf Fibers/Epoxy Composites Using Micromechanical Technique (Micromechanical 시험법을 이용한 Kenaf 및 Ramie 섬유 강화 에폭시 복합재료의 계면물성 평가)

  • Park, Joung-Man;Tran, Quang Son;Jung, Jin-Gyu;Kim, Sung-Ju;Hwang, Byung-Sun
    • Journal of Adhesion and Interface
    • /
    • v.6 no.2
    • /
    • pp.13-20
    • /
    • 2005
  • Interfacial shear strength (IFSS) of environmentally friendly natural fiber reinforced polymer composites plays a very important role in controlling the overall mechanical performance. The IFSS of various Ramie and Kenaf fibers/epoxy composites was evaluated using the combination of micromechanical test and nondestructive acoustic emission (AE) to find out optimal conditions for desirable final performance. Dynamic contact angle was measured for Ramie and Kenaf fibers and correlated the wettability properties with interfacial adhesion. Mechanical properties of Ramie and Kenaf fibers were investigated using single-fiber tensile test and analyzed statistically by both uni-and bimodal Weibull distributions. An influence of clamping effect on a real elongation for both Ramie and Kenaf fibers were evaluated as well. Two different microfailure modes, axial debonding and fibril fracture coming from fiber bundles and single fiber composites (SFC) were observed under tension and compression.

  • PDF

Analysis of fatigue crack growth behavior in composite-repaired aluminum place (복합재 패치 보강 평판의 균열선단 진전거동 해석)

  • 이우용;이정주
    • Composites Research
    • /
    • v.17 no.4
    • /
    • pp.68-73
    • /
    • 2004
  • An analytical study was conducted to characterize the fatigue crack growth behavior of pre-cracked aluminum plates repaired with asymmetric bonded composite patch. For single-sided repairs, due to the asymmetry and the presence of out-of$.$plane bending, crack front shape would become skewed curvilinear started from a uniform through-crack profile, as observed from Previous studies. Therefore, for the accurate investigation of fatigue behavior, it is necessary to predict the actual crack front evolution and take it into consideration in the analysis. In this study, the fatigue analysis of single-sided repairs considering crack front shape development was conducted by implementing three-dimensional successive finite element method coupled with linear elastic fracture mechanics (LEFM) concept, which enables the growing crack front to be directly traced and modeled in a step by step way. Through conducting present analysis technique, crack path of the patched plate as well as the fatigue life was evaluated with sufficient accuracy. The analytical predictions of both the crack front shape evolution and the fatigue life were in good agreement with the experimental observations.

Comparing the Use of Single and Double Interlocking Distal Screws on a Polarus Intramedullary Nail for Humeral Shaft Fractures

  • Yang, Hee Seok;Kim, Jeong Woo;Kang, Hong Je;Park, Jung Hyun;Lee, Yong Chan;Kim, Kwang Mee
    • Clinics in Shoulder and Elbow
    • /
    • v.18 no.2
    • /
    • pp.91-95
    • /
    • 2015
  • Background: Our aim was to make a comparative analysis of radiological and clinical outcomes of using either one or two interlocking distal screws on a Polarus intramedullary nail for the internal fixation of humeral shaft fractures. Methods: From January 2008 to March 2014, we enrolled 26 patients with humeral shaft fractures who were operated on using intramedullary nails. The patients were divided into 2 groups according to how many interlocking distal screws were used to lock the Polarus nail: in group 1, a single interlocking distal screw was used in 12 patients; and in group 2, double interlocking distal screws, in 14 patients. We compared the degree of recovery of the displaced fracture fragments between the two groups. To compare the nonunion and shoulder function, we assessed each patient's modified American Shoulder and Elbow Surgerns (ASES) score. Results: We found that 10 of 12 fractures achieved union in group 1, and 13 of 14 fractures, in group 2. We did not find a meaningful difference in the time to bone union between the two groups. The percentage of recovery of displaced fracture fragments until union was 66.9% for group 1 and 59.41% for group 2. At the final follow-up, we found that the scores for shoulder joint modified ASES was 78.7 for group 1 and 80.7 for group 2. Conclusions: Our results show that if locked appropriately, even a single screw on a Polarus nail can provide satisfactory radiological union and improved clinical outcome after intramedullary nailing of humeral shaft fractures.

Celiac Artery Compression After a Spine Fracture, and Pericardium Rupture After Blunt Trauma: A Case Report from a Single Injury

  • Kim, Joongsuck;Cho, Hyun Min;Kim, Sung Hwan;Jung, Seong Hoon;Sohn, Jeong Eun;Lee, Kwangmin
    • Journal of Trauma and Injury
    • /
    • v.34 no.2
    • /
    • pp.130-135
    • /
    • 2021
  • Celiac artery compression is a rare condition in which the celiac artery is compressed by the median arcuate ligament. Case reports of compression after trauma are hard to find. Blunt traumatic pericardium rupture is also a rare condition. We report a single patient who experienced both rare conditions from a single blunt injury. An 18-year-old woman was brought to the trauma center after a fatal motorcycle accident, in which she was a passenger. The driver was found dead. Her vital signs were stable, but she complained of mild abdominal pain, chest wall pain, and severe back pain. There were no definite neurologic deficits. Her initial computed tomography (CT) scan revealed multiple rib fractures, moderate lung contusions with hemothorax, moderate liver injury, and severe lumbar spine fracture and dislocation. She was brought to the angiography room to check for active bleeding in the liver, which was not apparent. However, the guide wire was not able to pass through the celiac trunk. A review of the initial CT revealed kinking of the celiac trunk, which was assumed to be due to altered anatomy of the median arcuate ligament caused by spine fractures. Immediate fixation of the vertebrae was performed. During recovery, her hemothorax remained loculated. Suspecting empyema, thoracotomy was performed at 3 weeks after admission, revealing organized hematoma without pus formation, as well as rupture of the pericardium, which was immediately sutured, and decortication was carried out. Five weeks after admission, she had recovered without complications and was discharged home.

EFFECT OF RESIN MATRIX ON DEGREE OF CONVERSION AND FRACTURE TOUGHNESS OF DENIAL COMPOSITES (기질레진의 조성에 따른 복합레진의 물리적 성질에 관한 연구)

  • Lee, Yun-Shin;Choi, Kyoung-Kyu;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.1
    • /
    • pp.77-86
    • /
    • 2002
  • Current composites are made with dimethacrylate monomers and silane-treated silica microfillers, either alone or with silane treated glass fillers The main reasons for clinical failure of dental composites are secondary caries, wear and fracture. Most of practitioner want to get a composite which is more tougher under occlusal stress, less polymerization contraction, and better handling properties in application clinically. The aim of this study was to investigate the influence of resin matrix with various flows on the physical proper-ties such as fracture toughness and degree of conversion of the experimental resins. It was hypothesized that flexible or tough resin composites can be designed by judicious choice of monomer composition Various flow resin matrices containing Bis-GMA, UDMA, and TEG-DMA were made by altering the pro-portion of the monomers. After the unfilled resins were light-cured for different light intensity, the fracture toughness(K$_{1c}$) was measured according to ASTM standard using the single edge notched geometry, and degree of conversion(DC) was measured by FTIR. And experimental composites were formulated with variations in the proportion of silanated quartz and strontium glass fillers as 60, 75, and 77wt%. Also, the physical properties of composites with various filer contents were evaluated as same manner. All resulting data were compared by ANOVA/Tukeys test at 0.05 level. The results were as follows; 1. The degree of conversion of high flow resin containing less Bis-GMA was higher than that of low flow unfilled resin 2. While the degree of conversion of unfilled resin was increased according to light intensity for polymerization, there was no significant increase with moderate and high light intensity. Also, the fracture toughness was not increased by high light intensity. 3. The fracture toughness was high in the low flow unfilled resin containing higher contents of Bis-GMA. 4. There was a significant increase for fracture toughness and a tendency for degree of conversion to be reduced when the content of fillers was increased. 5. In the experimental composites, the flow of resin matrix did not affected on the fracture toughness, even, which was decreased as increase of viscosity. These results showed that the physical properties of a dental composite could be attributed to the flow of resin matrix with relative content of monomers. Specific combination of resin monomers should be designed to fulfil the needs of specific indication for use.