• 제목/요약/키워드: Single Wafer Cleaning

검색결과 13건 처리시간 0.029초

T형의 waveguide를 이용한 Post CMP용 메가소닉 세정장치에 대한 연구 (Study of T Type Waveguide in Single Wafer Megasonic Cleaning for Post CMP)

  • 김태곤;이양래;임의수;강국진;김현세;박진구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.364-365
    • /
    • 2006
  • Transverse some wave was generated by T type waveguide for single wafer cleaning application T type megasonic waveguide was analyzed by acoustic pressure measurements and particle removal efficiency. Compared to conventional longitudinal waves, not like longitudinal waves, transverse waves showed changes of direction and phase which increased the cleaning efficiency.

  • PDF

매엽식 세정장비의 동작순서 시뮬레이션 및 웨이퍼 처리량 측정에 관한 연구 (Study on Measurement of Wafer Processing Throughput and Sequence Simulation of SWP(Single Wafer Process) Cleaning Equipment)

  • 선복근;한광록
    • 전자공학회논문지CI
    • /
    • 제42권5호
    • /
    • pp.31-40
    • /
    • 2005
  • 본 연구에서는 웨이퍼의 식각, 세정, 연마 공정에 사용되는 매엽식 세정장비의 동작순서의 시뮬레이션과 단위 시간당 처리량 측정 방법에 대해 연구한다. 유한상태기계를 바탕으로 스케쥴링 알고리즘에 따른 로봇의 상태를 정의하여 시뮬레이션 모델을 구축하였으며, 이에 따른 시뮬레이션 수행을 통해 세정장비의 시간당 처리량을 측정하였다. 본 연구에서 제시한 시뮬레이션 기법을 통해 레시피와 로봇의 동작속도에 따라 세정장비의 단위시간당 처리량을 측정하고, 처리량을 극대화 할 수 있는 레시피와 로봇의 동작순서를 찾아낼 수 있다.

Evaluation of Particle Removal Efficiency during Jet Spray and Megasonic Cleaning for Aluminum Coated Wafers

  • Choi, Hoomi;Min, Jaewon;Kulkarni, Atul;Ahn, Youngki;Kim, Taesung
    • 반도체디스플레이기술학회지
    • /
    • 제11권3호
    • /
    • pp.7-11
    • /
    • 2012
  • Among various wet cleaning methods, megasonic and jet spray gained their popularity in single wafer cleaning process for the efficient removal of particulate contaminants from the wafer surface. In the present study, we evaluated these two cleaning methods for particle removal efficiency (PRE) and pattern damage on the aluminum layered wafer surface. Also the effect of $CO_2$ dissolved water in jet spray cleaning is assessed by measuring PRE. It is observed that the jet spray cleaning process is more effective in terms of PRE and pattern damage compared to megasonic cleaning and the mixing of $CO_2$ in the water during jet sprays further increases the PRE. We believe that the outcome of the present study is useful for the semiconductor cleaning process engineers and researchers.

Wafer 반송용 End-Effector의 FEM 해석 및 파지력 제어에 관한 연구 (A Study on the FEM Analysis and Gripping Force Control of End-Effector for the Wafer Handling Robot System)

  • 권오진;최성주;이우영;이강원;박원규
    • 반도체디스플레이기술학회지
    • /
    • 제2권3호
    • /
    • pp.31-36
    • /
    • 2003
  • On this study, an E.E(End-Effector) for the 300 mm wafer transfer robot system is newly suggested. It is a mechanical type with $180^{\circ}$ rotating ranges and is composed of 3-point arms, two plate springs and single-axis DC motor controlled by microchip. To design, relationship between the gripping force and the wafer deformation is analyzed by FEM. By analytic results, the gripping force for 300 mm wafer is confirmed as 255~274 gf. From experimental results on gripping force, repeatable position accuracy and gripping cycle times in a wafer cleaning system, we confirmed that the suggested E.E was well designed to satisfiy on the required performance for 300 mm wafer transfer robot system.

  • PDF

나노입자 제거용 Far Field 메가소닉 개발 (Development of a Far Field type Megasonic for Nano Particle Removing)

  • 이양래;김현세;임의수
    • 한국정밀공학회지
    • /
    • 제30권11호
    • /
    • pp.1193-1201
    • /
    • 2013
  • Improved far field type(improved type) megasonic applicable to the cleaning equipment of single wafer processing type has been developed. In this study, to improve the uniformity of acoustic pressure distribution(APD), we utilize far field with relatively uniform APD, piezoelectric ceramic with a triangle hole in its center to prevent standing wave resulted from radial mode, and reflected wave from the wall of waveguide. On the basis of these methods, two analysis models of improved type were designed to which piezoelectric ceramic of different shape of electrode attached, and APD were analyzed by means of finite element method, and then one of them was selected by analysis results, finally, the selected model was fabricated. Test results show that the fabricated is better in the uniformity of APD than the imported and the conventional, also the fabricated shows high particle removal efficiency of 92.3% using DI water alone as a cleaning solution.

초고속 미세 액적 충돌을 이용한 나노미터 크기 입자상 오염물질의 세정에 대한 CFD 시뮬레이션 (CFD simulation of cleaning nanometer-sized particulate contaminants using high-speed injection of micron droplets)

  • 박진효;김정건;이승욱;이동근
    • 한국입자에어로졸학회지
    • /
    • 제18권4호
    • /
    • pp.129-136
    • /
    • 2022
  • The line width of circuits in semiconductor devices continues to decrease down to a few nanometers. Since nanoparticles attached to the patterned wafer surface may cause malfunction of the devices, it is crucial to remove the contaminant nanoparticles. Physical cleaning that utilizes momentum of liquid for detaching solid nanoparticles has recently been tested in place of the conventional chemical method. Dropwise impaction has been employed to increase the removal efficiency with expectation of more efficient momentum exchange. To date, most of relevant studies have been focused on drop spreading behavior on a horizontal surface in terms of maximum spreading diameters and average spreading velocity of drop. More important is the local liquid velocity at the position of nanoparticle, very near the surface, rather than the vertical average value. In addition, there are very scarce existing studies dealing with microdroplet impaction that may be desirable for minimizing pattern demage of the wafer. In this study, we investigated the local velocity distribution in spreading liquid film under various impaction conditions through the CFD simulation. Combining the numerical results with the particle removal model, we estimated an effective cleaning diameter (ECD), which is a measure of the particle removal capacity of a single drop, and presented the predicted ECD data as a function of droplet's velocity and diameter particularly when the droplets are microns in diameter.

Wafer 반송용 End-Effector의 설계 및 파지력 제어에 관한 연구

  • 권오진;최성주;이우영;이강원
    • 한국반도체및디스플레이장비학회:학술대회논문집
    • /
    • 한국반도체및디스플레이장비학회 2003년도 춘계학술대회 발표 논문집
    • /
    • pp.80-87
    • /
    • 2003
  • On this study, an End-Effector for the 300mm wafer transfer robot System is newly suggested. It is a mechanical type with $180^{\circ}$ rotating ranges and is composed of 3-point arms, two plate springs and single-axis DC motor. It is controlled by microchip for the DC motor control. To design, relationships on the gripping force and the wafer deformation is analyzed by FEM analysis. Criterion on gripping force of a suggested End-Effector is confirmed as $255 ~ 274g_f$ from experimental results. From experimented results on repeatable position accuracy, gripping force and gripping cycle times in a wafer cleaning system, we confirmed that the suggested End-Effector is well satisfied on the required performance for 300mm wafer transfer robot system.

  • PDF

주성분분석과 신경회로망의 융합을 통한 실리콘 웨이퍼의 마이크로 크랙 분류에 관한 연구 (A Study on Classification of Micro-Cracks in Silicon Wafer Through the Fusion of Principal Component Analysis and Neural Network)

  • 서형준;김경범
    • 한국정밀공학회지
    • /
    • 제32권5호
    • /
    • pp.463-470
    • /
    • 2015
  • Solar cell is typical representative of renewable green energy. Silicon wafer contributes about 66 percent to its cost structure. In its manufacturing, micro-cracks are often occurred due to manufacturing process such as wire sawing, grinding and cleaning. Their detection and classification are important to process feedback information. In this paper, a classification method of micro-cracks is proposed, based on the fusion of principal component analysis(PCA) and neural network. The proposed method shows that it gives higher results than single application of two methods, in terms of shape and size classification of micro-cracks.

Development of Multi-Chemical Supply System for Semiconductor Wafer Cleaning Station

  • Chung, Myung-Jin;Song, Young-Wook
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1309-1312
    • /
    • 2005
  • A multi-chemical supply system is developed and applied to a wet station, which uses the multi-chemical process in one bath. To control the concentration of two chemicals, control logic of a supply pump is programmed using the programable logic controller (PLC). By using the multi-chemical supply system, wet station with single bath is applied to cleaning process using multi chemicals such as buffed oxide etchant (BOE) and standard clean 1 (SC-1). The concentration of each chemical is measured in the bath to verify the multi-chemical supply system. The control range in the each chemical concentration is measured to 1.33weight% in NH4OH and 0.23weight% in H2O2. The multi-chemical supply system can be movable and usable as an independent module of fixed wet station. By simply midifying the PLC, a multi-chemical supply system can be developed for a wet station.

  • PDF