• Title/Summary/Keyword: Single Stage

Search Result 2,448, Processing Time 0.033 seconds

Measurement of the Metabolism of Energy Substrates in Single IVF-derived Bovine Embryos (소 체외수정란에 있어서 Non-invasive 방법에 의한 기질 대사량의 측정)

  • ;;S. Sugawara
    • Korean Journal of Animal Reproduction
    • /
    • v.19 no.3
    • /
    • pp.161-169
    • /
    • 1995
  • To investigate the metabolism of various substrates in preimplantation bovine embryos, uptake of glucose and pyruvate, and lactate production were measured in single IVF-derived bovine embryos by a non-invasive method. When the embryos were incubated for 5 h in culture medium supplemented with 1 mM glucose and 0.4mM pyruvate as substrates at each developmental stage, glucose uptake was increased with more advanced developmental stages while pyruvate uptake was decreased. Total lactate producton of 2-cell embryos was significantly higher than that of blastocysts (p<0.05). Both of glucose uptake and lactate production in normal morulae produced in vitro was significantly high compared to the degenerated embryos(p<0.05). The results obtained in the study suggest that pyruvate as an exogenous substrate may be support in bovine embryos until 8-cell stage, whereas glucose may be effective as an energy source after morula stage. In addition, it was proven thatlactate was not effective as an energy source in preimplantation development of IVF-derived bovine embryos.

  • PDF

Single Stage Anatomic Repair of Aortic Atresia with Normal Left Ventricle (정상 좌심실을 가진 대동맥 판막 폐쇄증에서의 일차성 완전교정술)

  • Kim, Uk-Seong;Kim, Yong-Jin
    • Journal of Chest Surgery
    • /
    • v.26 no.9
    • /
    • pp.701-704
    • /
    • 1993
  • Four to seven percent of infants born with aortic atresia have a normal-sized left ventricle in association with a ventricular septal defect and a normal mitral valve. In contrast to the more common group of infants with aortic atresia whose left ventricle is hypoplastic, this important subgroup has potential for complete operative correction involving both the right and left ventricle. Our approach was to perform complete repair at one stage. The patient who underwent single-stage repair was discharged from the hospital in good condition. Achieving a physiologically normal circulation simplifies the postoperative management of this condition.

  • PDF

Single Stage Replacement of Entire Thoracic Aorta for Chronic Aortic Dissection (만성 대동맥 박리 환자에서 전 흉부 대동맥 동시 치환)

  • 최진호;박계현;전태국;이영탁;박표원
    • Journal of Chest Surgery
    • /
    • v.34 no.11
    • /
    • pp.865-869
    • /
    • 2001
  • Operations for extensive aortic aneurysm are generally performed as staged operations with or without elephant trunk technique. However, we must consider single stage replacement in cases that are unsuitable for elephant trunk technique. We report a case of successful sing1e stage replacement of the entire thoracic aorta from the aortic valve to the level of diaphragm. The patient was a 35-year-old male who had Marfanoid features and had previously undergone replacement of the ascending aorta for aortic dissection. He recovered without neurologic complication and was discharged on 29th day after the operation. .

  • PDF

A Second-order Harmonic Current Reduction with a Fast Dynamic Response for a Two-stage Single-phase Grid-connected Inverter

  • Jung, Hong-Ju;Kim, Rae-Young
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.1988-1994
    • /
    • 2014
  • In a single-phase grid-connected power system consisting of a DC/DC converter and a DC/AC converter, the current drawn from renewable energy sources has a tendency to be pulsated and contains second-order frequency ripple components, which results in several drawback such as a power harvesting loss and a shortening of the energy source's life. This paper presents a new second-order harmonic current reduction scheme with a fast dc-link voltage loop for two-stage dc-dc-ac grid connected systems. In the frequency domain, an adequate control design is performed based on the small signal transfer function of a two-stage dc-dc-ac converter. To verify the effectiveness of proposed control algorithm, a 1 kW hardware prototype has been built and experimental results are presented.

Study of Single-Stage High-Power-Factor Electronic Ballast for fluorescent lamps operating in critical conduction mode (임계모드에서 동작하는 단일 전력단을 갖는 고역률 형광등용 전자식 안정기에 관한 연구)

  • Seo, C.S.;Kim, D.H.;Byun, Y.B.;Lee, P.S.;Sim, K.Y.;Oh, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1126-1128
    • /
    • 2001
  • A single-stage high-power-factor electron ic ballast operating in critical conduction mode is presented in this paper. The proposed topology is based on integration of a boost-like converter and a LCC Type half-bridge serial resonant inverter. The power-factor-correction(PFC) stage is a boost-like converter operating in critical conduction mode for positive and negative half cycle voltage respectively at line frequency (60Hz) so that a high power factor is achieved naturally. The simulated and experimental results for 100w fluorescent lamps operating at 42kHz switching frequency and 220V line voltage have been obtained.

  • PDF

Nano Position Control of Plane X-Y Stage Using Minimum Order Observer (최소차원 관측기를 이용한 평면 X-Y 스테이지의 나노 위치제어)

  • 김재열;윤성운;곽이구;안재신;한재호
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.180-185
    • /
    • 2003
  • Performance test of servo control system that is used ultra-precision positioning system with single plane X-Y stage is performed by simulation with Matlab. Analyzed for previous control algorithm and adapted for modem control theory, dual servo algorithm is developed by minimum order observer, and stability priority on controller are secured. Through the simulation and experiments on ultra precision positioning, stability and priority on ultra-precision positioning system with single plane X-Y stage and control algorithm are secured by using Matlab with Simulink and ControlDesk made in dSPACE

  • PDF

The Oscillation Frequency of CML-based Multipath Ring Oscillators

  • Song, Sanquan;Kim, Byungsub;Xiong, Wei
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.6
    • /
    • pp.671-677
    • /
    • 2015
  • A novel phase interpolator (PI) based linear model of multipath ring oscillator (MPRO) is described in this paper. By modeling each delay cell as an ideal summer followed by a single pole RC filter, the oscillation frequency is derived for a 4-stage differential MPRO. It is analytically proved that the oscillation frequency increases with the growth of the forwarding factor ${\alpha}$, which is also confirmed quantitatively through simulation. Based on the proposed model, it is shown that the power to frequency ratio keeps constant as the speed increases. Running at the same speed, a 4-stage MPRO can outperform the corresponding single-stage ring oscillator (SPRO) with 27% power saving, making MPRO with a large forwarding factor ${\alpha}$ an attractive option for lower power applications.

Three-Phase Isolated Capacitorless Charger with a Single-Stage Power Converter (1단 전력변환기를 가진 3상 절연형 커패시터리스 충전기)

  • Chae, Soo-Yong;Hong, Soon-Chan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.11
    • /
    • pp.84-92
    • /
    • 2014
  • In this paper, we propose a three-phase isolated electrolytic capacitorless charger available for quick charger. In the proposed charger, electrolytic capacitor in DC link is eliminated by direct conversion from AC input to DC output. Conventional chargers are two stage structure including AC-DC and DC-DC converters, but the proposed charger can be simplified into single stage converter by using a matrix converter. And the waveform of input currents is improved by giving the weighting factor to the duty ratio of auxiliary switches. In order to verify the effectiveness of the proposed charger, simulations are carried out and a 1.2kW charger was constructed and experimented.

An Optimization Study on the Reliquefaction of Boil-Off Gas from Liquefied Petroleum Gas Storage Tank (액화석유가스 저장탱크로부터 발생하는 증발가스 재액화 공정의 최적화에 대한 연구)

  • NOH, SANGGYUN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.5
    • /
    • pp.395-400
    • /
    • 2019
  • Comparative studies between single- and two-stage refrigeration cycle using propane as a refrigerant have been performed for a vapor recompression refrigeration cycle. PRO/II with PROVISION release 10.2 from AVEVA company was used, and the Soave-Redlich-Kwong equation of state model with Twu's alpha function was selected for the modeling and optimization of the refrigeration cycle for the reliquefaction of BOG coming out from the LPG storage tank. In two-stage refrigeraton cycle, 24.8% of compressor power was reduced compared to that of single-stage refrigeration cycle through the optimization works.

A Study on the Separation of Fetal ECG from a Single Channel Abdominal ECG (단일채널 복부 심전도를 통한 태아 심전도 분리)

  • Park Kwang-Li;Lee Kyoung-Joung;Lee Jeon
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.3
    • /
    • pp.198-205
    • /
    • 2005
  • In this paper, we proposed a new algorithm for the separation of fetal ECG from single channel abdominal ECG. The algorithm consists of a stage of demixing vector calculation for initial signal and a stage of fetal beat detection for the rest of signal. The demixing vector was obtained by applying independent component analysis technique to projected signals into time-frequency domain. For the test of this algorithm, simulation signals, De Lathauwer's data and some measured data, which was acquired from 8 healthy volunteers whose pregnant periods ranged from 22 weeks to 35 weeks and whose ages from 27 to 37, were used. For each data, the accuracy of fetal beat detection was $100\%$ and with the location of fetal beats, fetal heart rate variability and morphology could be offered. In conclusion, this proposed algorithm showed the possibility of fetal beat separation with a single channel abdominal ECG and it might be adopted to a fetal health monitoring system, by which a single channel abdominal ECG is acquired.