• Title/Summary/Keyword: Single Stage

Search Result 2,448, Processing Time 0.03 seconds

Performance and Parameter Comparison between single stage and Two-Stage Compression/Absorption Heat Pump System (단단 및 2단 압축/흡수 히트펌스시스템의 성능 및 중요인자비교 분석)

  • Tian, Huaizhang;Park, Seong-Ryong
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.451-456
    • /
    • 2005
  • The mathematical model for the heat exchangers of absorber and desorber is made in the elementary control volume method and the thermodynamic properties of working fluid. water/ammonia mixture. are calculated by some fundamental subroutines in RefProp 7.0 and flash subroutines made by authors The simulation results show that two-stage cycle has higher COP than single stage if temperature lift is high: the performance of single stage compression cycle can be improved by increase of absorber pressure. but the performance of two-stage compression cycle can not be improved in this way : the compressor discharging temperature of two-stage compression is much lower than that of single stage cycle. which is very important to the safety operation of CA heat pump. Major parameter comparison between the cycles at their optimal configurations is also given.

  • PDF

Modified RCC MPPT Method for Single-stage Single-phase Grid-connected PV Inverters

  • Boonmee, Chaiyant;Kumsuwan, Yuttana
    • Journal of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.1338-1348
    • /
    • 2017
  • In this study, a modified ripple correlation control (RCC) maximum-power point-tracking (MPPT) algorithm is proposed for a single-stage single-phase voltage source inverter (VSI) on a grid-connected photovoltaic system (GCPVS). Unlike classic RCC methods, the proposed algorithm does not require high-pass and low-pass filters or the increment of the AC component filter function in the voltage control loop. A simple arithmetic mean function is used to calculate the average value of the photovoltaic (PV) voltage, PV power, and PV voltage ripples for the MPPT of the RCC method. Furthermore, a high-accuracy and high-precision MPPT is achieved. The performance of the proposed algorithm for the single-stage single-phase VSI GCPVS is investigated through simulation and experimental results.

Surgical Strategy for Primary Colorectal Carcinoma and Synchronous Pulmonary Metastasis Resection

  • Kim, Tae Yeon;Cho, Jong Ho;Choi, Yong Soo;Kim, Hong Kwan;Kim, Jhin Gook;Shim, Young Mog
    • Journal of Chest Surgery
    • /
    • v.55 no.1
    • /
    • pp.37-43
    • /
    • 2022
  • Background: The surgical strategy for single-stage resection of primary colorectal cancer (CRC) and synchronous pulmonary metastases remains a matter of debate. Methods: Perioperative data of patients who underwent single-stage resection of primary CRC and synchronous pulmonary metastases were compared to those of patients who underwent 2-stage resections. The demographic data, number of metastases, type of pulmonary and colorectal resections, operation time, blood loss, postoperative complications, morbidities, mortality, medical costs, and length of hospital stay were analyzed. Results: Twenty-two patients underwent single-stage resection of primary CRC and pulmonary metastases, while 27 patients underwent 2-stage resection. Tumor size and the number of pulmonary metastases were not significantly different between the 2 groups. The extent of pulmonary metastasectomy and abdominal procedures were similar in both groups, as was the thoracic surgical approach (video-assisted thoracic surgery vs. thoracotomy). However, open laparotomy was performed more frequently in the 2-stage group than in the single-stage group (p=0.045), which also had a longer total anesthetic time (p=0.013). The operation time, medical costs, estimated blood loss, complication rates, and severity were similar in both groups, but the length of hospital stay was shorter in the single-stage group (p<0.001). Conclusion: Single-stage colorectal and pulmonary resection shortened the overall hospital stay, with no significant changes in operation time, medical costs, hospital mortality, and morbidity. Therefore, single-stage resection could be a good surgical strategy in selected patients.

Optimal Design of Cylinder Configuration for a 1-Stage Two Cylinder $CO_2$ Compressor (1단 2실린더 $CO_2$ 압축기의 실린더 형상 최적 설계)

  • Ahn, Jong-Min;Kim, Hyun-Jin;Cho, Sung-Oug
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.119-124
    • /
    • 2008
  • Recently, focus has been drawn on natural refrigerants due to increasing concern on global warming. As a consequence, CO2 systems such as a heat pump water heater using CO2 as a refrigerant are rapidly growing on the market. Currently, rolling piston rotary compressors are widely used for CO2 heating and/or refrigeration systems. There are several ways of realizing gas compression structure. They are single stage compression with single cylinder, single stage compression with two cylinders, and two stage compression with two cylinders. In this paper, computer simulation program which was validated for a single stage rotary compressor with one cylinder has been extended for a single stage, two cylinder rotary type. Numerical investigation has been made on optimal design for the cylinder configuration using the extended simulation program. For a single stage two cylinder rotary compressor having a displacement volume of 4 cc for each cylinder, compressor efficiency has been found to be maximum when the cylinder radius and height are 31mm and 10mm, respectively.

  • PDF

Phase II two-stage single-arm clinical trials for testing toxicity levels

  • Kim, Seongho;Wong, Weng Kee
    • Communications for Statistical Applications and Methods
    • /
    • v.26 no.2
    • /
    • pp.163-173
    • /
    • 2019
  • Simon's two-stage designs are frequently used in phase II single-arm trials for efficacy studies. A concern of safety studies is too many patients who experience an adverse event. We show that Simon's two-stage designs for efficacy studies can be similarly used to design a two-stage safety study by modifying some of the design parameters. Given the type I and II error rates and the proportion of adverse events experienced in the first stage cohort, we prescribe a procedure whether to terminate the trial or proceed with a stage 2 trial by recruiting additional patients. We study the relationship between a two-stage design with a safety endpoint and an efficacy endpoint as well as use simulation studies to ascertain their properties. We provide a real-life application and a free R package gen2stage to facilitate direct use of two-stage designs in a safety study.

Effect of Protein Feeding Systems for Egg-type Growing Pullets on Pullet Growth, Nutrient Consumption and Subsequent Laying Performance (난용계 육성기의 단백질 공급체계가 육성계의 성장 및 영양소 섭취량과 산란능력에 미치는 영향)

  • 이규호;정연종
    • Korean Journal of Poultry Science
    • /
    • v.21 no.4
    • /
    • pp.257-266
    • /
    • 1994
  • Three protein feeding systems for egg-type pullets involving conventional step-down protein 18-15-12%), step-up protein(12-15-18%) and single-stage low protein (13-13-13%) with an iso-energy level of 2,900 ME kcal /kg were compared to examine the effect on pullet growth and subsequent laying performance. During the growing period, pullets subjected to the step-up and single-stage low protein feeding systems were lighter in body weight and consumed less feed and netabolizable energy than those on the conventional step-down protein feeding system(P<0.05). 3ut the pullets on the step-up protein diet consumed more protein, and those on the single-stage low protein diet consumed less protein than those on the step-down protein diet(P<0.05). Also, he feed cost was less in pullets on the single-stage low protein diet than in those on the other systems(P<0.05). During the laying period, sexual maturity was later in hens reared on the step-up and single-stage low protein diets than in those on the step-down protein diet(P<0.05), however, average hen-day egg production and egg weight were not significantly affected by the protein feeding systems in the growing period. Daily feed intake and feed required per egg were significantly reduced in hens on the single-stage low protein diet compared to those on conventional protein feeding system(P<0.05). It was concluded that the 13% single-stage low protein feeding system produced smaller pullets with less feed, energy, protein, and feed cost during the growing period, and hens reared on that system consumed less feed during the laying period without any impairment of production compared to the conventional rearing system.

  • PDF

Soft Switching Single Stage AC-DC Full Bridge Boost Converter Using Non-Dissipative Snubber (무손실 스너버 적용 소프트 스위칭 Single Stage AC-DC Full Bridge Boost 컨버터)

  • 김은수;조기연;김윤호;조용현;박경수;안호균;박순구
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.4
    • /
    • pp.377-383
    • /
    • 1999
  • A new soft switching single stage AC-DC full bridge boost converter with unit input power factor and isolated output i is presented in this paper. Due to the use of a non-dissipative snubber on the primary side, a single stage high-power f factor isolated full bridge boost converter has a significant reduction of switching losses in the main switching devices. The non-dissipative snubber adopted in this study consists of a snubber capacitor Cr, a snubber inductor Cr, a fast r recovery snubber diode Dr' and a commutation diode Dp. This paper presents the complete operating principles, t theoretical analysis and experimental results.

  • PDF

Direct Single-stage Power Converter with Power Factor Improvement for Switched Mode Power Supply

  • Kalpana, R.;Singh, Bhim;Bhuvaneswari, G.
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.3
    • /
    • pp.468-476
    • /
    • 2010
  • This paper presents a direct single-stage power converter using single-phase isolated full-bridge converter modules, with inherent power factor correction (PFC) for a 12 kW switched mode power supply (SMPS). The advantages of the proposed converter are its simple control strategy, reduction in number of conversion stage, low input line current harmonics, and improvement in power factor. Analysis of the single-stage converter is carried out in continuous conduction mode of operation. Steady-state analysis of the proposed converter is conducted to obtain converter parameters. A systematic design procedure is also presented for a 12k W converter with a design example. The effect of load variation on SMPS is also studied in order to demonstrate the effectiveness of the proposed converter for the complete range of load conditions. A set of power quality indices on input ac mains for an SMPS fed from a single-stage converter is also presented for easy comparison of their performance.

A Numerical Method & Experiments for the Aerodynamic Design of High Performance 2-Stage Axial Flow Fans (고성능 2단 축류송풍기의 공력설계를 위한 수치해석 및 실험에 관한 연구)

  • Cho, Jinsoo;Han, Cheolhui;Cho, Leesang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.8
    • /
    • pp.1048-1062
    • /
    • 1999
  • A numerical method and experiments for the aerodynamic design of high performance two-stage axial flow fans was carried out. A vortex ring element method used for the aerodynamic analysis of the propellers was extended to the fan-duct system. Fan Performance and velocity profiles at the fan inlet and outlet are compared with experimental data for the validations of numerical method. Performance test was done based on KS B 6311(testing methods for turbo-fans and blowers). The velocity profile was obtained using a 5-hole pitot tube by the non-nulling method. The two stage axial flow fan configurations for the optimal operation conditions were set by using the experimental results for the single rotating axial flow fan and the single stage axial flow fan. The single rotating axial flow fan showed relatively low efficiency due to the swirl velocities behind rotor exit which produced pressure losses. In contrast, the single stage and the two-stage axial flow fans showed performance improvements due to the swirl velocity reduction by the stator. The peak efficiency of the two stage axial flow fan was improved by 21% and 6%, compared to the single rotating axial flow fan and the single stage axial flow fan, respectively.

Two-stage & Single-stage Power Factor Correction circuits for Single-phase Power source (단상전원에 적합한 단일단 및 2단 역률개선회로)

  • Kim Chert-Jin;Yoo Byeong-Kyu;Kim Choong-Sik;Kim Young-Tae
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1214-1216
    • /
    • 2004
  • Conventional Switched Mode Power Supplies(SMPS) with diode-capacitor rectifier have distorted input current waveform with high harmonic contents. Typically, these SMPS have a power factor lower than 0,65. To improve with this problem the power factor correction(PFC) circuit of power supplies has to be introduced. PFC circuit have tendency to be applied in new power supply designs. The input active power factor correction circuits can be implemented using either the two-stage or the single-stage approach. In this paper, the comparative analysis of power factor correction circuit using feedforward control with average current mode single-stage flyback method converter and two-stage converter which is combination of boost and flyback converter. The two prototypes of 50W were designed and tested a laboratory experimental. Also, the comparative analysis is confirmed by simulation and experimental results.

  • PDF