• Title/Summary/Keyword: Single Sensor

Search Result 1,584, Processing Time 0.028 seconds

Current control of 6/4 pole SRM with Delta modulation using Single current sensor (한 상의 전류검출에 의한 6/4극 SRM의 3상 Delta modulation 전류제어)

  • Kim D.K.;Yoon Y.H.;Song S.H.;Won C.Y.;Kim Y.R.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.671-676
    • /
    • 2003
  • This paper presents 3-phase current regulation of SR motor by only single current sensor. The conventional drive system of SR motor has a current sensor per each phase. In this paper, The asymmetric bridge converter which Is able to control independently phases and be excited simultaneously is used fs the driver system for 6/4 poles SR motor. And the sensor Is replaced 3 sensors of each phase with only one on bus line of converter so as to detect current of every phase. A drive logic circuit is designed on EPLD with Delta modulation using a fixed frequency This technique is verified through simulation and experiment.

  • PDF

Development of Wireless Instrument for Measuring Cattle's Somatic Information for Stockbreeding Automatization(II) - Development of Single-Channel Wireless Instrument for Measuring Sphygmus - (축산자동화를 위한 가축의 생체정보 무선 계측장치 개발(II) - 단일채널 무선 맥박 계측장치 개발 -)

  • Lee, S.K.;Min, Y.B.;Kim, T.K.
    • Journal of Biosystems Engineering
    • /
    • v.17 no.4
    • /
    • pp.404-409
    • /
    • 1992
  • It is important to measure the somatic informations for stockbreeding automatization. This study was carried out for the development of wireless measurement system of sphygmus in living animals. In meauring sphygmus counting with the single-channel telemety system, a LED-photo transistor sensor showed more sensitivity to the change of blood pressure than a piezo-electric sensor based pressure sensor. The LED-photo transistor sensor resulted ${\pm}1.29%$ of measurement error of sphygmus counting. In the process of transmitting and receiving the blood pressure signal for counting sphygmus, noises were mixed with, and the noises made the counting almost impossible. Auto-correlation analysis technique was applied to the signal data to extract the sphygmus information, and the technique was proved to be very effective.

  • PDF

Formal Models of Module Linking Mechanisms for a Single Address Space

  • Kim, Hiecheol;Hong, Won-Kee
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.19 no.2
    • /
    • pp.51-58
    • /
    • 2014
  • As WSNs(Wireless Sensor Networks) are being deployed widely in diverse application areas, their management and maintenance become more important. Recent sensor node software takes modular software architectures in pursuit of flexible software management and energy efficient reprogramming. To realize an flexible and efficient modular architecture particularly on resource constrained mote-class sensor nodes that are implemented with MCUs(Micro-Controller Units) of a single address space. an appropriate module linking model is essential to resolve and bind the inter-module global symbols. This paper identifies a design space of module linking model and respectively their implementation frameworks. We then establish a taxonomy for module linking models by exploring the design space of module linking models. Finally, we suggest an implementation framework respectively for each module linking model in the taxonomy. We expect that this work lays the foundations for systematic innovation toward more flexible and efficient modular software architectures for WSNs.

Development of the Measurement System for the Multi-Functional DO Sensor (다기능 DO 센서용 계측시스템 개발)

  • 이동희;김태진;최복길
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.86-88
    • /
    • 1996
  • A method is presented for the development of the PC-based measurement system on the 6 cathodes-single anode type multi-functional oxygen electrodes for detecting various components of the solution by measuring the dissolved oxygen(DO) concentration. The system is consisted with the 6 channel sensor signal modyfing circuits for the sensor and the PC interface circuits using the single chip microprocessor 80c196kc. Typical polarograms for the DO probes under test using this sensor circuits are presented. This system covers wide range of measuring time from 300sec to over 16 hour in one measurement step by programming the 9 monitor disply mode.

  • PDF

A Design of Single Pixel Photon Counter for Digital X-ray Image Sensor (X-ray 이미지 센서용 싱글 픽셀 포톤 카운터 설계)

  • Baek, Seung-Myun;Kim, Tae-Ho;Kang, Hyung-Geun;Jeon, Sung-Chae;Jin, Seung-Oh;Huh, Young;Ha, Pan-Bong;Park, Mu-Hun;Kim, Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.2
    • /
    • pp.322-329
    • /
    • 2007
  • A single pixel photon counting type image sensor which is applicable for medical diagnosis with digitally obtained image and industrial purpose has been designed with $0.18{\mu}m$ triple-well CMOS process. The designed single pixel for readout chip is able to be operated by single supply voltage to simplify digital X-ray image sensor module and a preamplifier which is consist of folded cascode CMOS operational amplifier has been designed to enlarge signal voltage(${\Delta}Vs$), the output voltage of preamplifier. And an externally tunable threshold voltage generator circuit which generates threshold voltage in the readout chip has been newly proposed against the conventional external threshold voltage supply. In addition, A dark current compensation circuit for reducing dark current noise from photo diode is proposed and 15bit LFSR(Linear Feedback Shift Resister) Counter which is able to have high counting frequency and small layout area is designed.

A channel parameter-based weighting method for performance improvement of underwater acoustic communication system using single vector sensor (단일 벡터센서의 수중음향 통신 시스템 성능 향상을 위한 채널 파라미터 기반 가중 방법)

  • Kang-Hoon, Choi;Jee Woong, Choi
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.6
    • /
    • pp.610-620
    • /
    • 2022
  • An acoustic vector sensor can simultaneously receive vector quantities, such as particle velocity and acceleration, as well as acoustic pressure at one location, and thus it can be used as a single input multiple output receiver in underwater acoustic communication systems. On the other hand, vector signals received by a single vector sensor have different channel characteristics due to the azimuth angle between the source and receiver and the difference in propagation angle of multipath in each component, producing different communication performances. In this paper, we propose a channel parameter-based weighting method to improve the performance of an acoustic communication system using a single vector sensor. To verify the proposed method, we used communication data collected from the experiment conducted during the KOREX-17 (Korea Reverberation Experiment). For communication demodulation, block-based time reversal technique which is robust against time-varying channels were utilized. Finally, the communication results showed that the effectiveness of the channel parameter-based weighting method for the underwater communication system using a single vector sensor was verified.

A Survey on Communication Protocols for Wireless Sensor Networks

  • Jang, Ingook;Pyeon, Dohoo;Kim, Sunwoo;Yoon, Hyunsoo
    • Journal of Computing Science and Engineering
    • /
    • v.7 no.4
    • /
    • pp.231-241
    • /
    • 2013
  • Improvements in wireless sensor network (WSN) technology have resulted in a large number of applications. WSNs have been mainly used for monitoring applications, but they are also applicable to target tracking, health care, and monitoring with multimedia data. Nodes are generally deployed in environments where the exhausted batteries of sensor nodes are difficult to charge or replace. The primary goal of communication protocols in WSNs is to maximize energy efficiency in order to prolong network lifetime. In this paper, various medium access control (MAC) protocols for synchronous/asynchronous and single/multi-channel WSNs are investigated. Single-channel MAC protocols are categorized into synchronous and asynchronous approaches, and the advantages and disadvantages of each protocol are presented. The different features required in multi-channel WSNs compared to single-channel WSNs are also investigated, and surveys on multi-channel MAC protocols proposed for WSNs are provided. Then, existing broadcast schemes in such MAC protocols and efficient multi-hop broadcast protocols proposed for WSNs are provided. The limitations and challenges in many communication protocols according to this survey are pointed out, which will help future researches on the design of communication protocols for WSNs.

Length Effects of Hetero-Core Optical Biosensor based on Evanescent Field Absorption

  • Shim, Joon-Hwon;Chan, Joo-Kwong;Sohn, Kyung-Rak
    • Journal of Navigation and Port Research
    • /
    • v.32 no.9
    • /
    • pp.723-727
    • /
    • 2008
  • Sensing performances of evanescent field absorption (EFA) hetero-core fiber sensor has been presented based on EFA by changing the length and the core diameter of the single mode fiber. Experimental results have demonstrated a good feature in their relationship between the length and the core diameter of the single mode fiber. The sensor consists of 2 fiber optics which have the same cladding diameter of $125{\mu}m$ However one fiber optic used is single mode and has varying core diameter ranging from 3.3 to $5.6{\mu}m$. The other fiber is multimode type and has a thicker fixed core diameter of $62.5{\mu}m$. The 2 fiber optics are thermally spliced together. Experiments conducted to measure the resonance wavelength were carried out over a range of refractive index, to find the optimum sensing length Experiments show that core diameter of the single mode fiber and sensing length offects the linearity and sensitivity.

Possible application of single-walled carbon nanotube transistors for humidity sensor (단겹 탄소나노튜브 트랜지스터의 나노습도센서 응용가능성 연구)

  • Na, Pil-Sun;Kim, Hyo-Jin;Lee, Young-Hwa;Lee, Jeong-O;Kim, Jin-Hee
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.331-336
    • /
    • 2005
  • The influence of water molecule on the electrical properties of single-walled carbon nanotube field effect transistors (SWNT-FETs) was reported. Conductance suppression was observed with the increase of the humidity. This can be explained by doping of the SWNT-FETs, which has p-type semiconductor characteristic, with the water molecules acting as an electron donor. However, after 65 % of humidity, conductance of the SWNT-FETs started to increase again, due to the opening of electron channels. Upon annealing at $400^{\circ}C$ in Ar atmosphere, conductance increases more than 500 %, and the threshold voltage shifts toward further positive gate voltages. The results of this experiment support possible application of single-walled carbon nanotubes for humidity sensing material.

Algorithm of Modified Single-slope A/D Converter with Improved Conversion Time for CMOS Image Sensor System

  • Lee, Sang-Hoon;Kim, Jin-Tae;Shin, Jang-Kyoo;Choi, Pyung
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.6
    • /
    • pp.359-363
    • /
    • 2015
  • This paper proposes an algorithm that reduces the conversion time of a single-slope A/D converter (SSADC) that has n-bit resolution, which typically is limited by conversion time taking up to $2^n$ clock cycles for an operation. To improve this situation, we have researched a novel hybrid-type A/D converter that consists of a pseudo-pipeline A/D converter and a conventional SSADC. The pseudo-pipeline A/D converter, using a single-stage of analog components, determines the most significant bits (MSBs) or upper bits and the conventional SSADC determines the remaining bits. Therefore, the modified SSADC, similar to the hybrid-type A/D converter, is able to significantly reduce the conversion time because the pseudo-pipeline A/D converter, which determines the MSBs (or upper bits), does not rely on a clock. The proposed A/D converter was designed using a $0.35-{\mu}m$ 2-poly 4-metal standard complementary metal oxide semiconductor (CMOS) technology process; additionally, its characteristics were simulated.