• 제목/요약/키워드: Single PD pulse

검색결과 11건 처리시간 0.029초

가스절연 구조에서 단일 부분방전펄스 분석에 의한 결함 판별 (Identification of Defect Type by Analysis of a Single PD Pulse in Gas Insulated Structure)

  • 조향은;김선재;정기우;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제28권5호
    • /
    • pp.320-325
    • /
    • 2015
  • This paper dealt with a defect identification algorithm which is based on single partial discharge (PD) pulse analysis in gas insulated structure. Four types of electrode systems such as a needle-plane, a plane-needle, a free particle and a crack inside spacer were fabricated to simulate defects in gas insulated switchgear (GIS). We measured single PD pulse by an oscilloscope with a sampling rate of 5 GS/s and a frequency bandwidth of 1 GHz. Data aquisition and signal processing were controlled by a LabVIEW program. Physical shapes of PD pulses were compared with kurtosis, skewness and time-based parameters as rising time, falling time and pulse-width. These parameters were analysed by an algorithm with a back propagation algorithm (BPA). By applying the algorithm, the identification rate was 97% for the needle-plane electrode, 96% for the plane-needle electrode, 91% for the free particle and 93% for the crack inside spacer. The results verified that the algorithm could identify the type of defects in GIS.

유중 부분방전 펄스 특성을 이용한 TF 분석에 대한 고찰 (Considerations on the TF Anal,ysis using Partial Discharge Pulse Characteristics in Oil)

  • 김정태
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권11호
    • /
    • pp.508-514
    • /
    • 2005
  • In this paper, it was investigated the characteristics of PD(partial discharge) pulse shapes in oil and the possibility of TF(Time-Frequency) analysis for the discrimination of air corona in on-site PD measurement of oil transformers. For the purpose, single and multiple discharges combined with oil discharges and air corona were generated and measured by use of artificial models through the HFPD pulse detector and the oscilloscope. PD pulse shapes were different according to the type of defects, especially including air corona- pulses. Also, through the TF analysis, data clusters could be classified each other in the TF Map, even in the case of multiple discharges. Therefore, it is known that TF analysis could be aprlied for the improvement of on-site PD measurement in oil transformers.

Setup of standard PD calibrator and its uncertainties

  • Kim, Kwang-Hwa;Yi, Sang-Hwa;Lee, Heun-Jin;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권5호
    • /
    • pp.677-683
    • /
    • 2011
  • The present paper describes the setup of standard partial discharge calibrator for measuring partial discharge and estimating uncertainties. The standard PD calibrator was designed and set up, consisting of a digital pulse generator, capacitor modules, and a digital oscilloscope controlled by software developed in the laboratory. Using this software, averages of charges and rising times and their standard deviations in the measured pulses can also be calculated. The standard PD calibrator generates five types of pulses: single, double, random, oscillating, and long-rising. The coefficient sensitivities to estimate the uncertainties of pulses were extracted in the model circuit of the standard PD calibrator. The uncertainties of charges and rising times in pulses of the standard PD calibrator were estimated with single pulses. These values were 0.3%-1.4% in charges and 1.9%-7.0% in rising time; however, these values are lower than the limit values in IEC 60270.

부분방전 교정펄스 발생기의 표준화 시스템구축과 불확도 (Setup and Uncertainty of Standard System for Calibrating Pulse Generator of Partial Discharge)

  • 김광화;이상화;이헌진;강동식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1355_1357
    • /
    • 2009
  • This paper describes the standard system for calibrating pulse generator of partial discharge(PD) and its uncertainty. The system is consisted of digital pulse generator, digital recorder and evaluation software. The uncertainty requirement of calibrator charge is less than $\pm$ (0.1pC + 0.03q) and that of pulse duration is less than $\pm$ 10 %. The system can generate various kind of calibration pulses such as single pulse, double pulses, oscillation pulse, long-duration pulse, random pulses and evaluate their uncertainty.

  • PDF

Novel Single-State PWM Technique for Common-Mode Voltage Elimination in Multilevel Inverters

  • Nguyen, Nho-Van;Quach, Hai-Thanh;Lee, Hong-Hee
    • Journal of Power Electronics
    • /
    • 제12권4호
    • /
    • pp.548-558
    • /
    • 2012
  • In this paper, a novel offset-based single-state pulse width modulation (PWM) method for achieving zero common-mode voltage (CMV) and reducing switching losses in multilevel inverters is presented. The specific active switching state of the zero common-mode (ZCM) voltage that approximates the reference voltage can be deduced from the switching state sequence of the reduced CMV phase disposition PWM (CMV PD PWM) method. From the reference leg voltages for the zero common-mode voltage, an N-to-2-level transformation defines a virtual two-level inverter and the corresponding nominal leg voltage references. The commutation process of the reduced CMV PD PWM method in a multilevel inverter and its outputs can be simply followed in a nominal switching time diagram for the virtual inverter. The characteristics of the reduced CMV PD PWM and the single-state PWM for zero common-mode voltage are analyzed in detail in this paper. The theoretical analysis of the proposed PWM method is verified by experimental results.

웨이블렛 변환을 이용한 부분 방전 신호 분석 (An Analysis of Partial Discharge signal Using Wavelet Transforms)

  • 박재준;장진강;임윤석;심종탁;김재환
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.169-172
    • /
    • 1999
  • Recently, the wavelet transform has been a new and powerful tool for signal processing. It is more suitable specially for the feature extraction and detection of non-stationary signals than traditional methods such as, the Fourier Transform(FT), the Fast Fourier Transform(FFT) and the Least Square Method etc. because of the characteristic of the multi-scale analysis and time-frequency domain localization. The wavelet transform has been developed for the analysis of PD pulse signal to raise in the progress of insulation degradation. In this paper, the wavelet transform was applied to one foundational method for feature extraction. For the obtain experimental data, a computer-aided partial discharge measurement system with a single acoustic sensor was used. If we are applying to the neural network method the accumulated data through the extracted feature, it is expected that we can detect the PD pulse signal in the insulation materials on the on-line.

  • PDF

부분방전 펄스특성을 이용한 TF Map에 대한 고찰 (Considerations on the TF Map using Partial Discharge Pulse Characteristics)

  • 김정태;김남준;장용무;김지홍;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2126-2128
    • /
    • 2005
  • In this paper, it was investigated the applicability of TF analysis for the discrimination of air corona in on-site PD measurement. For the purpose, single and multiple discharges combined with oil discharges and air corona were generated and measured by use of artificial models and HFPD pulse detector. Through the TF analysis, data clusters could be classified each other in the TF Map, even in the case of multiple discharges. Therefore, it is known that TF analysis could be applied for the improvement of on-site PD measurement.

  • PDF

Estimation of baroreflex sensitivity using pulse arrival time rather than systolic blood pressure measurement

  • Lee, Jong-Shill;Chee, Young-Joon
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권1호
    • /
    • pp.14-19
    • /
    • 2010
  • Baroreflex sensitivity (BRS) is a parameter of the cardiovascular system that is reflected in changes in pulse interval (PD and systolic blood pressure (SBP). BRS contains information about how the autonomic nervous system regulates hemodynamic homeostasis. Normally the beat-to-beat SBP measurement and the pulse interval measured from the electrocardiogram (ECG) are required to estimate the BRS. We investigated the possibility of measuring BRS in the absence of a beat-to-beat SBP measurement device. Pulse arrival time (PAT), defined as the time between the R-peak of the ECG and a single characteristic point on the pulse wave recorded from any arterial location was measured by photoplethysmography. By comparing the BRS obtained from conventional measurements with our method during controlled breathing, we confirmed again that PAT and SBP are closely correlated, with a correlation coefficient of -0.82 to -0.95. The coherence between SBP and PI at a respiration frequency of 0.07-0.12 Hz was similar to the coherence between PAT and PI. Although the ranges and units of measurement are different (ms/mmHg vs. ms/ms) for BRS measured conventionally and by our method, the correlation is very strong. Following further investigation under various conditions, BRS can be reliably estimated without the inconvenient and expensive beat-to-beat SBP measurement.

1급 와동에서 상아질과 복합레진의 결합강도에 대한 중합방법의 효과 (THE EFFECT OF DIFFERENT CURING MODES ON COMPOSITE RESIN/DENTIN BOND STRENGTH IN CLASS ICAVITIES)

  • 백신영;조영곤;송병춘
    • Restorative Dentistry and Endodontics
    • /
    • 제33권5호
    • /
    • pp.428-434
    • /
    • 2008
  • 본 연구는 1급 복합레진 수복물에서 할로겐 광조사기를 이용한 4가지 중합방법이 상아질의 결합강도에 미치는 효과를 알아보기 위하여 시행하였다. 발거된 상 하악 대구치 20개의 교합면측 법랑질을 Diamond Wheel Saw를 이용하여 제거한 후 1급 와동을 형성하였다. 중합방법에 따라 파동지연 중합방법 (PD) 군, 연성 중합방법 (SS) 군, 파동 중합방법 (PC) 군, 지속 중합방법 (CC) 군의 4개 군으로 분류하고, Z250 복합레진을 각 군의 와동에 충전한 후 광조사하였다. 각 군의 시편을 주수하에 접착계면의 단면적이 $1mm^2$가 되도록 절단하여 막대모양의 시편을 제작하였고, 각 군당 20개의 시편을 사용하여 미세인장 결합강도를 측정하여 다음과 같은 결과를 얻었다. 1. PD 군은 PC 군과 CC 군보다 통계학적으로 더 높은 미세인장 결합강도를 나타내었다. 2. SS군의 미세인장 결합강도는 PC 군과 CC 군보다 높게 나타났으나, 통계학적으로 유의한 차이를 나타내지 않았다. 결론적으로, 1급 복합레진 수복물을 중합할 때 파동지연 중합방법과 연성 중합방법을 사용하여 중합속도를 조절함으로써 상아질과 복합레진의 결합강도를 개선할 수 있을 것으로 사료된다.

멀티모드 레이다 신호처리를 위한 저복잡도 FFT 프로세서 설계 (Design of Low-complexity FFT Processor for Multi-mode Radar Signal Processing)

  • 박예림;정용철;정윤호
    • 한국항행학회논문지
    • /
    • 제24권2호
    • /
    • pp.85-91
    • /
    • 2020
  • 최근 다양한 환경에서 무인기를 효율적으로 운용하기 위한 목적으로 멀티모드 레이다 시스템이 고안되었으며, 이는 PD (pulse Doppler) 방식과 FMCW (frequency modulated continuous wave) 방식을 통합하여 활용할 수 있다는 장점을 가진다. 멀티모드 레이다 시스템의 하드웨어 구조의 경우 FFT (fast Fourier transform) 프로세서와 IFFT (inverse fast Fourier transform) 프로세서가 필수적이지만, FFT 프로세서는 큰 복잡도를 갖는 구조 중 하나로 FFT 프로세서의 복잡도를 감소시키는 방향으로의 구조 설계가 필요하다. 또한, 다양한 거리 해상도를 요구하는 레이다 응용 환경을 고려했을 때, FFT 프로세서는 가변 길이의 연산을 지원할 필요가 있다. 이에 본 논문에서는 멀티모드 레이다 신호처리 프로세서 거리 추정부의 FFT 프로세서와 IFFT 프로세서를 16~1024 포인트의 가변 길이 연산을 지원하는 단일 FFT 프로세서의 하드웨어로 설계하여 제안한다. 제안된 FFT 프로세서는 MATLAB 기반 알고리즘 설계를 수행한 뒤, 그 결과를 토대로 Verilog-HDL (hardware description language)을 활용하여 RTL (register transfer level) 설계가 수행되었으며, 논리 합성 결과 총 총 7,452개의 logic elements, 5,116개의 registers로 구현 가능함을 확인하였다.