• 제목/요약/키워드: Single Operation

검색결과 2,606건 처리시간 0.031초

구역분할 버스운영에 관한 연구 - 2-구역분할 운영의 경우 - (A Study on Zonal Operation of Buses - 2-Zonal operation Case -)

  • 고승영;이양호
    • 대한교통학회지
    • /
    • 제14권1호
    • /
    • pp.69-80
    • /
    • 1996
  • In most cities, travel demand is distributed along long corridors and its destinations tend to concentrate in a central business district. For this kind of many-to-one or one-to-many travel demand pattern, a zonal operation of buses can be an efficient bus operation technique in which a long bus-demand corridor is divided into service zones and each service zone is provided with its own bus route connecting the service zone and single destination separately. This paper develops models of the total transportation costs for a single-zone operation and 2-zonal operation of buses for a long demand corridor with single destination in terms of various cost parameters, demand density, bus operation speeds, and location of the boundary between two service zones. In this study the total transportation cost is assumed to consist of the bus operation cost, passenger waiting cost and passenger travel time cost. It was proved that a zonal operation of buses can be more efficient than a single-zone operation for certain circumstances of the system and an boundary condition between two operation techniques was obtained. Also, several case studies were performed for various values of the cost parameters.

  • PDF

복선구간의 단선운행 방안 시뮬레이션 (Single line Operation in a double line)

  • 정의진;김종기;이재호;조봉관;김양모
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.384-386
    • /
    • 1998
  • In the emergency case such as a single line operation in a double line section because of a line broken or train's mal-operation, single line equipments that can operate without a line indication are needed. The main purpose of this study is to verify and analyze the availability of the single line operation that is able to operate without the indication of up or down line, and to offer a realizably alternative method to improve this situation. In order to carry out this study, we concentrated on getting related information. And to adopt the single line operation to existing line, the technology survey of other countries signalling system and the technical analysis of the interior signalling equipment were performed. As a result of this study, the required system and effect of the single line operation system were represented.

  • PDF

단상유도전동기의 효율개선을 위한 평형운전에 관한 연구 (A Study on Balanced Operation for Efficiency Improvement of Single Phase Induction Motor)

  • 백수황;김병택;권병일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.143-145
    • /
    • 2006
  • In this paper, single phase induction motor achieved improvement in efficiency by adapting the condition of Balanced operation and Quasi-balanced operation. Also, the process of efficiency improvement to find the optimum point of secondary resistance and running capacitor for working single phase induction motor is performed in order to attain the conclusion to put out the maximum efficiency at the rated operation point with meeting the starting torque.

  • PDF

Analysis, Design, Modeling, Simulation and Development of Single-Switch AC-DC Converters for Power Factor and Efficiency Improvement

  • Singh, Bhim;Chaturvedi, Ganesh Dutt
    • Journal of Power Electronics
    • /
    • 제8권1호
    • /
    • pp.51-59
    • /
    • 2008
  • This paper addresses several issues concerning the analysis, design, modeling, simulation and development of single-phase, single-switch, power factor corrected AC-DC high frequency switching converter topologies with transformer isolation. A detailed analysis and design is presented for single-switch topologies, namely forward buck, flyback, Cuk, Sepic and Zeta buck-boost converters, with high frequency isolation for discontinuous conduction modes (DCM) of operation. With an awareness of modem design trends towards improved performance, these switching converters are designed for low power rating and low output voltage, typically 20.25W with 13.5V in DCM operation. Laboratory prototypes of the proposed single-switch converters in DCM operation are developed and test results are presented to validate the proposed design and developed model of the system.

다목적댐군의 실제 연계운영 효과 평가 (Evaluation of Effects of Real Joint-Operation of Multi-purpose Dams)

  • 강민구;이광만;차형선
    • 한국수자원학회논문집
    • /
    • 제40권2호
    • /
    • pp.101-112
    • /
    • 2007
  • 본 연구에서는 댐군을 연계운영할 경우 발생하는 효과를 이수측면에서 평가할 수 있는 방법을 개발하여 한강수계 댐군 운영 실적의 평가에 적용하였다. 개발된 평가방법에서는 용수공급과 유황개선 부분에서 연계운영의 효과를 평가하기 위하여 평가지점에서 필요수량에 대한 충족률과 유황안정도를 평가지표로 사용하였다 발전 부분에서 연계운영의 효과는 댐군에 의해 생산된 총발전량을 평가지표로 사용하였다. 실제 운영실적은 공칭공급량을 공급하는 단독운영과 최적화 모형에 의한 평가지표들과 비교하여 평가되었다. 한강수계의 2001년부터 2004년까지의 실제 연계운영 실적을 단독운영과 최적화 모형의 결과와 각 연도별로 비교해 보면, 용수공급 측면에서 필요수량 충족률은 단독운영은 $94.36{\sim}99.68%$, 실제운영은 $97.16{\sim}99.90%$, 최적화 모형은 4개년 모두 100.0 %를 나타냈다. 댐 운영 방법별로 하상계수와 유황계수를 사용하여 유황안정도를 평가해 보면, 유황이 단독운영 보다 실제운영과 최적화 모형이 더 안정적인 결과를 나타냈다. 실제 총발전량을 다른 운영방법의 결과와 비교해 보면, 최적화 모형은 실제 총발전량 보다 $-3.47{\sim}6.54%$ 증가된 결과를 나타냈으며, 단독운영은 실제 총발전량 보다 $12.68{\sim}38.94%$ 감소된 결과를 나타냈다.

가전기기용 소형 단상 Written Pole Motor의 운전특성 (Operation Characteristics of a Small Single-phase Written-pole Motor in Home Appliance)

  • 박성철;이원용;유병훈;김대경;신덕식;김병택
    • 전기학회논문지
    • /
    • 제59권2호
    • /
    • pp.311-317
    • /
    • 2010
  • This paper deals with operation characteristics of a written-pole motor (WPM), having that of a permanent magnet (PM) synchronous motor and induction motor at once. The WPM also has a magnet layer on the surface of the rotor and the exciter pole that is a device to make the magnet layer magnetized during the operation. This study, introducing a fundamental structure and operation characteristics of a single-phase WPM, proposes a initial design method. With those ground, a 130W, single-phase WPM that is designed for a home appliance is presented and verified with a performance through the experiment.

단상 Inverter를 사용한 단상/3상 상변환기구와 그 특성에 관한 연구 (Characteristic Study on Single to Three Phase Conversion Using Single Phase Inverter)

  • 이승원;남부희
    • 전기의세계
    • /
    • 제27권3호
    • /
    • pp.47-52
    • /
    • 1978
  • This paper deals with the phase converter. The single-phase inverter with 120.deg.C phase-lagging is used for the phase conversion. As the waveform of the inverter is rectangular, the output waveforms of the three-phase lines include the harmonics. Single-phase operation by using phase converter and three-phase balanced operation of the three-phase induction motor are compared, and the effects of the harmonics are analyzed and discussed.

  • PDF

단배부 절개를 이용한 무지 외반증 수술 (Single Dorsal Incision Technic for Hallux Valgus Surgery)

  • 송경원;박인헌;김갑래;이승용;현윤석;서은호
    • 대한족부족관절학회지
    • /
    • 제11권1호
    • /
    • pp.35-38
    • /
    • 2007
  • Purpose: In this study, we introduced a newly developed technique of operation for hallux valgus. We used a single dorsal incision to correct major components of Bunion in stead of two or three incisions, which had been used by most of surgeons for long time. Materials and Methods: Between 2003 and 2005, 27 feet with hallux valgus deformity were operated through single dorsal incision. 10 out of 17 patients underwent operation on both feet, 5 patient underwent operation on left feet, remaining 2 underwent operation on right. There were 16 women and 1 man. Average age of patients was 45 (range, 21-59). Post operatively all feet were evaluated by physical examination, Maryland Foot score profile, radiographic measurements and complication. Results: Maryland foot score profile increased from preoperative 67/100 to postoperative 95/100. Most patients satisfied pain relieve and cosmesis. Average preoperative intermetatarsal angle was 15 degrees, which were decreased to 9 degrees after operation and average preoperative hallux valgus angle was 32 degrees, which were decreased to 12 degrees after operation. Conclusion: According to our experience, the single dorsal incision technic for correction of moderate to severe hallux valgus deformities was rather safe and easily performed without noticeable complication with almost same results as multiple incisions technics. We highly recommend this technic to be tried by foot surgeons without hesitation.

  • PDF

3실형 인버터 열펌프 시스템의 냉방성능 측정 (Cooling Performance Measurement of a 3 Room Type Inverter Heat Pump System)

  • 정광진;최영돈;장효환;송재복;박윤철
    • 설비공학논문집
    • /
    • 제13권6호
    • /
    • pp.431-439
    • /
    • 2001
  • Recently, multi-room type heat pump system has aroused much attention, because it can achieve much reduction of installation cost and space as well as energy saving in companion with the single room type heat pump system. In the present study, performance characteristics of a 3 room type inverter driven heat pump system, which is widely spread in Japanese market, are measured.. In the single room operation, performances of a heat pump system such s the difference of compressor outlet and inlet pressures and the mass flowrate may increase with the increase of cooling capacity so that COP of the system decrease with the increase of cooling capacity. However, in the 2 room operation, mass flowrate and COP of the total system increase markedly as compared with the single room operation.

  • PDF

마이크로 가스터빈의 탈설계 운전 성능특성 (Performance Characteristics for Off-design Operation of Micro Gas Turbines)

  • 황성훈;김동섭
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.80-87
    • /
    • 2003
  • Micro gas turbines are designed with low turbine inlet temperature and pressure ratio. To overcome the efficiency defect of the simple cycle, adoption of the recuperator is an inevitable choice. In addition to the design performance, we should also pay attention to the off-design performance of gas turbines since they usually operate at part-load conditions for a considerable amount of the time. This study aims at analyzing off-design performance characteristics of micro gas turbines and addressing the importance of the recuperator in the part load operation. Comparative analyses have been performed to evaluate the part load performance differences among various design and operating options : simple vs recuperative cycles, single vs two shaft configurations, various operating strategies for the single shaft configuration (fuel only control, variable speed operation, variable inlet guide vane control), and current vs advanced engines. Major finding is that maintaining turbine at high level is crucial in efficient operation of micro gas turbines.

  • PDF