• Title/Summary/Keyword: Single Operation

Search Result 2,587, Processing Time 0.03 seconds

A Study on Zonal Operation of Buses - 2-Zonal operation Case - (구역분할 버스운영에 관한 연구 - 2-구역분할 운영의 경우 -)

  • 고승영;이양호
    • Journal of Korean Society of Transportation
    • /
    • v.14 no.1
    • /
    • pp.69-80
    • /
    • 1996
  • In most cities, travel demand is distributed along long corridors and its destinations tend to concentrate in a central business district. For this kind of many-to-one or one-to-many travel demand pattern, a zonal operation of buses can be an efficient bus operation technique in which a long bus-demand corridor is divided into service zones and each service zone is provided with its own bus route connecting the service zone and single destination separately. This paper develops models of the total transportation costs for a single-zone operation and 2-zonal operation of buses for a long demand corridor with single destination in terms of various cost parameters, demand density, bus operation speeds, and location of the boundary between two service zones. In this study the total transportation cost is assumed to consist of the bus operation cost, passenger waiting cost and passenger travel time cost. It was proved that a zonal operation of buses can be more efficient than a single-zone operation for certain circumstances of the system and an boundary condition between two operation techniques was obtained. Also, several case studies were performed for various values of the cost parameters.

  • PDF

Single line Operation in a double line (복선구간의 단선운행 방안 시뮬레이션)

  • Joung, E.J.;Kim, J.K.;Lee, J.H.;Cho, B.K.;Kim, Y.M.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.384-386
    • /
    • 1998
  • In the emergency case such as a single line operation in a double line section because of a line broken or train's mal-operation, single line equipments that can operate without a line indication are needed. The main purpose of this study is to verify and analyze the availability of the single line operation that is able to operate without the indication of up or down line, and to offer a realizably alternative method to improve this situation. In order to carry out this study, we concentrated on getting related information. And to adopt the single line operation to existing line, the technology survey of other countries signalling system and the technical analysis of the interior signalling equipment were performed. As a result of this study, the required system and effect of the single line operation system were represented.

  • PDF

A Study on Balanced Operation for Efficiency Improvement of Single Phase Induction Motor (단상유도전동기의 효율개선을 위한 평형운전에 관한 연구)

  • Baek, Soo-Whang;Kim, Byung-Taek;Kwon, Byung-Il
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.143-145
    • /
    • 2006
  • In this paper, single phase induction motor achieved improvement in efficiency by adapting the condition of Balanced operation and Quasi-balanced operation. Also, the process of efficiency improvement to find the optimum point of secondary resistance and running capacitor for working single phase induction motor is performed in order to attain the conclusion to put out the maximum efficiency at the rated operation point with meeting the starting torque.

  • PDF

Analysis, Design, Modeling, Simulation and Development of Single-Switch AC-DC Converters for Power Factor and Efficiency Improvement

  • Singh, Bhim;Chaturvedi, Ganesh Dutt
    • Journal of Power Electronics
    • /
    • v.8 no.1
    • /
    • pp.51-59
    • /
    • 2008
  • This paper addresses several issues concerning the analysis, design, modeling, simulation and development of single-phase, single-switch, power factor corrected AC-DC high frequency switching converter topologies with transformer isolation. A detailed analysis and design is presented for single-switch topologies, namely forward buck, flyback, Cuk, Sepic and Zeta buck-boost converters, with high frequency isolation for discontinuous conduction modes (DCM) of operation. With an awareness of modem design trends towards improved performance, these switching converters are designed for low power rating and low output voltage, typically 20.25W with 13.5V in DCM operation. Laboratory prototypes of the proposed single-switch converters in DCM operation are developed and test results are presented to validate the proposed design and developed model of the system.

Evaluation of Effects of Real Joint-Operation of Multi-purpose Dams (다목적댐군의 실제 연계운영 효과 평가)

  • Kang, Min-Goo;Lee, Gwang-Man;Cha, Hyung-Sun
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.2 s.175
    • /
    • pp.101-112
    • /
    • 2007
  • In this study, a methodology was developed to evaluate the effects produced in the event of joint-operation of dams from the viewpoint of water use. It was applied to evaluating the actual results of dam operation in the Han River basin. In order to evaluate the effects of real joint-operation in terms of water supply and flow conditions, the methodology used the satisfaction rate of water requirement and the stability of flow conditions at the evaluation site as indicator. In order to evaluate the effects of joint-operation in terms of power generation, the total power generation produced by dams was used as evaluation indicator. Actual operation results were evaluated by comparison of evaluation indicators relating to single dam operation by which the notified mont of water was supplied, as well as to optimization models. Results of actual joint-operation of the Han River basin, from 2001 to 2004, were compared yearly with results from single operation and optimization model; in terms of water supply, the satisfaction ratio of water requirement stood at $94.36{\sim}99.68%$ for single operation, $97.16{\sim}99.90%$ for actual joint-operation, and 100.0 % for optimization model for all four years. The stability of flow condition was evaluated by the coefficient of river regime and coefficient of flow conditions definitely, indicating that flow conditions were more stable in case of actual operation and optimization models than in case of single operation. The actual total power generation was compared with that generated by other operation rules, indicating that the optimization model increased the power generation by $-3.47{\sim}6.54%$ compared with the actual total power generation, and that the single operation decreased the power generation amount by $12.68{\sim}38.94%$ compared with the actual total power generation.

Operation Characteristics of a Small Single-phase Written-pole Motor in Home Appliance (가전기기용 소형 단상 Written Pole Motor의 운전특성)

  • Park, Seong-Cheol;Lee, Won-Yong;Yu, Byung-Hun;Kim, Dae-Kyong;Shin, Duck-Shick;Kim, Byung-Taek
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.2
    • /
    • pp.311-317
    • /
    • 2010
  • This paper deals with operation characteristics of a written-pole motor (WPM), having that of a permanent magnet (PM) synchronous motor and induction motor at once. The WPM also has a magnet layer on the surface of the rotor and the exciter pole that is a device to make the magnet layer magnetized during the operation. This study, introducing a fundamental structure and operation characteristics of a single-phase WPM, proposes a initial design method. With those ground, a 130W, single-phase WPM that is designed for a home appliance is presented and verified with a performance through the experiment.

Characteristic Study on Single to Three Phase Conversion Using Single Phase Inverter (단상 Inverter를 사용한 단상/3상 상변환기구와 그 특성에 관한 연구)

  • 이승원;남부희
    • 전기의세계
    • /
    • v.27 no.3
    • /
    • pp.47-52
    • /
    • 1978
  • This paper deals with the phase converter. The single-phase inverter with 120.deg.C phase-lagging is used for the phase conversion. As the waveform of the inverter is rectangular, the output waveforms of the three-phase lines include the harmonics. Single-phase operation by using phase converter and three-phase balanced operation of the three-phase induction motor are compared, and the effects of the harmonics are analyzed and discussed.

  • PDF

Single Dorsal Incision Technic for Hallux Valgus Surgery (단배부 절개를 이용한 무지 외반증 수술)

  • Song, Kyung-Won;Park, In-Heon;Kim, Gab-Lae;Lee, Seung-Yong;Hyun, Youn-Seok;Seo, Eun-Ho
    • Journal of Korean Foot and Ankle Society
    • /
    • v.11 no.1
    • /
    • pp.35-38
    • /
    • 2007
  • Purpose: In this study, we introduced a newly developed technique of operation for hallux valgus. We used a single dorsal incision to correct major components of Bunion in stead of two or three incisions, which had been used by most of surgeons for long time. Materials and Methods: Between 2003 and 2005, 27 feet with hallux valgus deformity were operated through single dorsal incision. 10 out of 17 patients underwent operation on both feet, 5 patient underwent operation on left feet, remaining 2 underwent operation on right. There were 16 women and 1 man. Average age of patients was 45 (range, 21-59). Post operatively all feet were evaluated by physical examination, Maryland Foot score profile, radiographic measurements and complication. Results: Maryland foot score profile increased from preoperative 67/100 to postoperative 95/100. Most patients satisfied pain relieve and cosmesis. Average preoperative intermetatarsal angle was 15 degrees, which were decreased to 9 degrees after operation and average preoperative hallux valgus angle was 32 degrees, which were decreased to 12 degrees after operation. Conclusion: According to our experience, the single dorsal incision technic for correction of moderate to severe hallux valgus deformities was rather safe and easily performed without noticeable complication with almost same results as multiple incisions technics. We highly recommend this technic to be tried by foot surgeons without hesitation.

  • PDF

Cooling Performance Measurement of a 3 Room Type Inverter Heat Pump System (3실형 인버터 열펌프 시스템의 냉방성능 측정)

  • 정광진;최영돈;장효환;송재복;박윤철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.6
    • /
    • pp.431-439
    • /
    • 2001
  • Recently, multi-room type heat pump system has aroused much attention, because it can achieve much reduction of installation cost and space as well as energy saving in companion with the single room type heat pump system. In the present study, performance characteristics of a 3 room type inverter driven heat pump system, which is widely spread in Japanese market, are measured.. In the single room operation, performances of a heat pump system such s the difference of compressor outlet and inlet pressures and the mass flowrate may increase with the increase of cooling capacity so that COP of the system decrease with the increase of cooling capacity. However, in the 2 room operation, mass flowrate and COP of the total system increase markedly as compared with the single room operation.

  • PDF

Performance Characteristics for Off-design Operation of Micro Gas Turbines (마이크로 가스터빈의 탈설계 운전 성능특성)

  • Hwang, S.H.;Kim, T.S.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.80-87
    • /
    • 2003
  • Micro gas turbines are designed with low turbine inlet temperature and pressure ratio. To overcome the efficiency defect of the simple cycle, adoption of the recuperator is an inevitable choice. In addition to the design performance, we should also pay attention to the off-design performance of gas turbines since they usually operate at part-load conditions for a considerable amount of the time. This study aims at analyzing off-design performance characteristics of micro gas turbines and addressing the importance of the recuperator in the part load operation. Comparative analyses have been performed to evaluate the part load performance differences among various design and operating options : simple vs recuperative cycles, single vs two shaft configurations, various operating strategies for the single shaft configuration (fuel only control, variable speed operation, variable inlet guide vane control), and current vs advanced engines. Major finding is that maintaining turbine at high level is crucial in efficient operation of micro gas turbines.

  • PDF