• 제목/요약/키워드: Single Component

검색결과 1,272건 처리시간 0.031초

HisCoM-PCA: software for hierarchical structural component analysis for pathway analysis based using principal component analysis

  • Jiang, Nan;Lee, Sungyoung;Park, Taesung
    • Genomics & Informatics
    • /
    • 제18권1호
    • /
    • pp.11.1-11.3
    • /
    • 2020
  • In genome-wide association studies, pathway-based analysis has been widely performed to enhance interpretation of single-nucleotide polymorphism association results. We proposed a novel method of hierarchical structural component model (HisCoM) for pathway analysis of common variants (HisCoM for pathway analysis of common variants [HisCoM-PCA]) which was used to identify pathways associated with traits. HisCoM-PCA is based on principal component analysis (PCA) for dimensional reduction of single nucleotide polymorphisms in each gene, and the HisCoM for pathway analysis. In this study, we developed a HisCoM-PCA software for the hierarchical pathway analysis of common variants. HisCoM-PCA software has several features. Various principle component scores selection criteria in PCA step can be specified by users who want to summarize common variants at each gene-level by different threshold values. In addition, multiple public pathway databases and customized pathway information can be used to perform pathway analysis. We expect that HisCoM-PCA software will be useful for users to perform powerful pathway analysis.

$S^{35}$(1,2-dichloro vinyl) L-Cysteine의 소에 의(依)한 대사물(代謝物)의 분리(分離)

  • 김재욱
    • Applied Biological Chemistry
    • /
    • 제2권
    • /
    • pp.36-39
    • /
    • 1961
  • It has been ascertained that S-(1, 2-dichlorovinyl) L-cysteine (DCVC) is probably the toxic component in the trichloro-ethylene extracted soybean oil meal on the bovine. For the study of the metabolites of DCVC, the components with radioactive $S^{35}$-in the urine of the calf, to which $S^{35}$-DCVC was administrated, were separated using of cellulose powder with propanol-water (70:30 V/V) which is easily removable by evaporation. As the results followings were obtained: Peak 1, which shows fractions containing single $S^{35}$-radioactive components, whose Rf is 0.815 Peak 2, which shows fractions containing jingle $S^{35}$-radioactive component, whose Rf is 0.447 Peak 3, which shows fractions containing both $S^{35}$-radioactive components whose Rfs are 0.090 and 0.171 Peak 4, which shows fractions containing single $S^{35}$-radioactive component, whose Rf is 0.142. Peak 5, which shows fractions containing single $S^{35}$-radioactive component, whose Rf is 0.084. Besides these, two of small peak were obtained. Although, the resolving power of the cellulose powder column is not sufficient, it is applicable for the study of the components of metabolytes of DCVC conveniently with the rest of removable solvent easily. Also the components with radioactive $S^{35}$ in the feces of the calf were separated using citrate buffer gradient system of Moore and stein. As the results; three $S^{35}$-radioactive components were separated.

  • PDF

Analysis of Decoupling Method in DQ Transform-based for Grid Connected Inverter

  • Windarko, Novie Ayub;Lee, Jin-Mok;Choi, Jae-Ho
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.924-925
    • /
    • 2008
  • There are many types of grid-connected inverter controllers, PI controller based is the most popular methods. But, a common PI control is produced zero-steady state error and phase delay in sinusoidal reference. Synchronous reference frame or DQ transform based controller is capable for reducing both of zero-steady state error and phase delay is. But DQ transform based controller has cross-coupling component which difficult to analyze the system in single phase model. In this paper, to obtained single phase model of the system, DQ transform based controller is analyzed in two techniques. The first is by neglecting cross-coupling. The second is eliminated cross-coupling component by decoupling method. By these two techniques, single phase model is obtained. Then, the single phase model is analyzed to evaluate its performance in stability and frequency response, through Root Locus and Bode diagram, respectively. MATLAB and PSIM simulation is used to verify the analysis. Simulation result is shown; cross-coupling component has no significant influent to the controller.

  • PDF

EXPERIMENTAL VALIDATION OF THE BACKSCATTERING GAMMA-RAY SPECTRA WITH THE MONTE CARLO CODE

  • Hoang, Sy Minh Tuan;Yoo, Sang-Ho;Sun, Gwang-Min
    • Nuclear Engineering and Technology
    • /
    • 제43권1호
    • /
    • pp.13-18
    • /
    • 2011
  • In this study, simulations were done of a 661.6 keV line from a point source of $^{137}Cs$ housed in a lead shield. When increasing the scattering angle from 60 to 120 degrees with a 6061 aluminum alloy target placed at angles of 30 and 45 degrees to the incident beam, the spectra showed that the single scattering component increases and that the multiple scattering component decreases. The investigation of the single and multiple scattering components was carried out using a MCNP5 simulation code. The component of the single Compton scattering photons is proportional to the target electron density at the point where the scattering occurs. The single scattering peak increases according to the thickness of the target and saturates at a certain thickness. The signal-to-noise ratio was found to decrease according to the target thickness. The simulation was experimentally validated by measurements. These results will be used to determine the best conditions under which this method can be applied to testing electron densities or to assess the thickness of samples to locate defects in them.

다성분연료 분무에 있어서 증발과정의 해석모델 제안 (Propose an Analysis Model of Evaporation Process in Multi-Component Fuel Spray)

  • 염정국;전중지지
    • 대한기계학회논문집B
    • /
    • 제33권5호
    • /
    • pp.373-380
    • /
    • 2009
  • The evaporation process of multi-component fuel is different from one of a single component, because the properties of each component affects among the components. In actual engine, the spatial distribution of fuel vapor concentration dominates auto-ignition and initial combustion, and depends on the volatility and diffusivity of each component fuel contained in the multi-component fuel. Then, this study proposes a simplified numerical scheme for analysis of evaporation process of multi-component fuel sprays. Evaporation process is calculated by KIVA-II code based on the simple two-phases region that is approximated by modified saturated liquid-vapor line, which was obtained by connecting the 50% distillation temperature for each component under several pressure fields. Consequently, it can be quantitatively simulated that vapor of low boiling fuel component mostly exists around nozzle and spray tip region, the high boiling duel component, on the other hand, mostly appears near the spray tip.

Colloidal Crystallization in Microgravity

  • Okubo, Tsuneo
    • 한국섬유공학회:학술대회논문집
    • /
    • 한국섬유공학회 2003년도 The Korea-Japan Joint Symposium
    • /
    • pp.5-6
    • /
    • 2003
  • Kinetic study on the colloidal crystallization of single component and mixture of different sizes or densities of spheres was made in the exhaustively deionized suspensions and in microgravity, and compared with the results in normal gravity. Colloidal crystallization rates were retarded in microgravity for single component of spheres, whereas rates of alloy crystallization were enhanced substantially in microgravity. The rotational diffusion coefficients of colloids and the formation reaction rates of colloidal silica spheres were also studied in microgravity.

  • PDF

적은 소자수를 갖고 전해커패시터가 없는 단일단 인터리브드 토템폴 전기자동차 탑재형 충전기 (A Reduced Component count Single-stage Electrolytic Capacitor-less Interleaved Totem-pole On-board Battery Charger)

  • 김병우;조우식;최세완
    • 전력전자학회논문지
    • /
    • 제22권6호
    • /
    • pp.510-516
    • /
    • 2017
  • This paper proposes a single-stage interleaved totem-pole on-board battery charger with a simple structure and a reduced component count. Apart from achieving ZVS turn-on of all switches and ZCS turn-off of all diodes, this charger does not require an input filter due to its CCM operation and bulky electrolytic capacitors, which in turn result in a high power density. A single-stage power conversion technique is applied to the interleaved structure in order to achieve a high power density and high efficiency. A 2.5 kW prototype of the proposed charger is also built and tested to validate the proposed operation.

채도의 선형 변환을 이용한 단일 영상 안개 제거 (Single Image Dehazing Using Linear Transformation of Saturation)

  • 박태희
    • 대한임베디드공학회논문지
    • /
    • 제14권4호
    • /
    • pp.197-205
    • /
    • 2019
  • In this paper, an efficient single dehazing algorithm is proposed based on linear transformation by assuming that a linear relationship exists in saturation component between the haze image and haze-free image. First, we analyze the linearity of saturation channel, estimate the medium transmission map in terms of the saturation component. Then, the intensity of haze-free image is assumed by using CLAHE to enhance contrast of haze image. Experimental results demonstrate that proposed algorithm can naturally recover the image, especially can remove color distortion caused by conventional methods. Therefore, our approach is competitive with other state-of-the art single dehazing methods.

A Scheduling Approach with Component Selection

  • Harashima, Katsumi;Satoh, Hisashi;Hiro, Daisuke;Kutsuwa, Toshiro
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 ITC-CSCC -1
    • /
    • pp.399-402
    • /
    • 2000
  • The reduction of chip area and delay is important purpose of Scheduling in High-Level Synthesis. This paper presents a scheduling approach with component selection. After obtaining a initial schedule taking only single-functional u-nits, the component selection of our approach attempts the reduction of chip area and/or delay by the selection more suitable components in a component library using Simulated Annealing.

  • PDF

주택용 단상 ESS-PCS의 전압손실과 직류링크 맥동을 고려한 직류측 배터리 사이즈 및 제어기 설계 (Design of DC Battery Size & Controller for Household Single-Phase ESS-PCS Considering Voltage Drop and DC Link Voltage Ripple)

  • 김용중;이진성;김효성
    • 전력전자학회논문지
    • /
    • 제23권2호
    • /
    • pp.94-100
    • /
    • 2018
  • Generally, in a single-phase energy storage system (ESS) for households, AC ripple component with twice the fundamental frequency exists inevitably in the DC link voltage of single-phase PCS. In the grid-connected mode of a single-phase inverter, the AC ripple component in the DC link voltage causes low-order harmonics on grid-side current that deteriorates power quality on an AC grid. In this work, a control system adopting a feedforward controller is established to eliminate the AC ripple interference on the DC link side. Optimal battery nominal voltage design method is also proposed by considering the voltage loss and AC ripple voltage on DC link side in a single-phase ESS. Finally, the control system and battery nominal voltage design method are verified through simulations and experiments.