• Title/Summary/Keyword: Single Chamber

Search Result 456, Processing Time 0.053 seconds

Complete Chloroplast Genome Sequence of Dumortiera hirsuta

  • Kwon, Woochan;Kim, Yongsung;Park, Jongsun
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2018.04a
    • /
    • pp.43-43
    • /
    • 2018
  • Dumortiera hirsuta (Sw.) Nees (Dumortieraceae) is a thallose liverwort distributed in tropics and subtropics. It is the only species in family Dumortieraceae, which is the second basal family in order Marchantiales. D. hirsuta is characterized by hairy receptacles and lacking air chamber. The complete chloroplast genome of D. hirsuta was successfully rescued from raw reads generated by HiSeq4000. Its total length is 122,050 bp consisting of four regions: large single copy (LSC) region (81,697 bp), small single copy (SSC) region (20,061 bp), and two inverted repeats (IRs; 10,146 bp per each). It contained 129 genes (84 coding DNA sequence (CDS), eight rRNAs, and 37 tRNAs); 18 genes including four rRNAs, and five tRNAs are duplicated in the IR regions. The overall GC content of D. hirsuta is 28.7%, which is almost same to that of Marchantia paleacea. Phylogenetic tree based on all genes from whole chloroplast genomes will provides phylogenetic position of D. hirstua. This sequence will be an fundamental resources for further researches of order Marchantiales.

  • PDF

Improved Self Plasma-Optical Emission Spectroscopy for In-situ Plasma Process Monitoring (실시간 플라즈마공정 모니터링을 위한 Self Plasma-Optical Emission Spectroscopy 성능 향상)

  • Jo, Kyung Jae;Hong, Sang Jeen
    • Journal of the Semiconductor & Display Technology
    • /
    • v.16 no.2
    • /
    • pp.75-78
    • /
    • 2017
  • We reports improved monitoring performance of Self plasma-optical emission spectroscopy (SP-OES) by augmenting a by-pass tube to a conventional straight (or single) tube type self plasma reactor. SP-OES has been used as a tool for the monitoring of plasma chemistry indirectly in plasma process system. The benefits of SP-OES are low cost and easy installation, but some semiconductor industries who adopted commercialized SP-OES product experiencing less sensitivity and slow sensor response. OH out-gas chemistry monitoring was performed to have a direct comparison of a conventional single type tube and a by-pass type tube, and fluid dynamic simulation on the improved hardware design was also followed. It is observed faster pumping out of OH from the chamber in the by-pass type SP-OES.

  • PDF

Experimental study on the spray characteristics of a dual-manifold liquid-centered swirl coaxial injector

  • Lee, Ingyu;Yoon, Jungsoo;Park, Gujeong;Yoon, Youngbin
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.15 no.4
    • /
    • pp.444-453
    • /
    • 2014
  • A throttleable rocket engine enables operational possibilities such as the docking of spacecraft, maneuvering in a certain orbit and landing on a planet's surface, altitude control, and entrance to atmosphere-less planets. Thus, throttling methods have long been researched. However, dual-manifold injectors, which represent one throttling method, have been investigated less than others. In this study, dual-manifold and single-manifold injectors were compared to determine the characteristics of dual-manifold injectors. Also, the effects of gas injection were investigated with various F/O ratios. To investigate the characteristics, mass flow rate, spray pattern, spray angle, and droplet size were measured. The spray angle and droplet size were captured by indirect photography. About 30 images were taken to assess the spray patterns and spray angle. Also, 700 images were analyzed to understand the droplet distribution and targeting area, moving to the right from the centerline with 1.11-cm intervals. The droplet size was obtained from an image processing procedure. From the results, the spray angle showed two transition regions, due to swirl momentum in the swirl chamber regardless of the F/O ratio. The droplet size showed similar trends in both dual-manifold and single-manifold injectors except in the low mass flow rate region. In the case of the dual- manifold injector, the spray cone was not fully developed in the low mass flow rate region due to low angular momentum in the swirl chamber.

The Effect of Injection Angle and Nozzle Diameter on HCCI Combustion (분사각 및 분공 직경이 예혼합 압축착화 엔진 연소에 미치는 영향)

  • Kook, Sang-Hoon;Kong, Jang-Sik;Park, Se-Ik;Bae, Choong-Sik;Kim, Jang-Heon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.2
    • /
    • pp.1-7
    • /
    • 2007
  • The effect of injector geometries including the injection angle and number of nozzle holes on homogeneous charge compression ignition (HCCI) engine combustion has been investigated in an automotive-size single-cylinder diesel engine. The HCCI engine has advantages of simultaneous reduction of PM and NOx emissions by achieving the spatially homogenous distribution of diesel fuel and air mixture, which results in no fuel-rich zones and low combustion temperature. To make homogeneous mixture in a direct-injection diesel engine, the fuel is injected at early timing. The early injection guarantees long ignition delay period resulting in long mixing period to form a homogeneous mixture. The wall-impingement of the diesel spray is a serious problem in this type of application. The impingement occurs due to the low in-cylinder density and temperature as the spray penetrates too deep into the combustion chamber. A hole-type injector (5 holes) with smaller angle ($100^{\circ}$) than the conventional one ($150^{\circ}$) was applied to resolve this problem. The multi-hole injector (14 holes) was also tested to maximize the atomization of diesel fuel. The macroscopic spray structure was visualized in a spray chamber, and the spray penetration was analyzed. Moreover, the effect of injector geometries on the power output and exhaust gases was tested in a single-cylinder diesel engine. Results showed that the small injection angle minimizes the wall-impingement of diesel fuel that results in high power output and low PM emission. The multi-hole injector could not decrease the spray penetration at low in-cylinder pressure and temperature, but still showed the advantages in atomization and premixing.

Therapeutic Proton Beam Range Measurement with EBT3 Film and Comparison with Tool for Particle Simulation

  • Lee, Nuri;Kim, Chankyu;Song, Mi Hee;Lee, Se Byeong
    • Progress in Medical Physics
    • /
    • v.30 no.4
    • /
    • pp.112-119
    • /
    • 2019
  • Purpose: The advantages of ocular proton therapy are that it spares the optic nerve and delivers the minimal dose to normal surrounding tissues. In this study, it developed a solid eye phantom that enabled us to perform quality assurance (QA) to verify the dose and beam range for passive single scattering proton therapy using a single phantom. For this purpose, a new solid eye phantom with a polymethyl-methacrylate (PMMA) wedge was developed using film dosimetry and an ionization chamber. Methods: The typical beam shape used for eye treatment is approximately 3 cm in diameter and the beam range is below 5 cm. Since proton therapy has a problem with beam range uncertainty due to differences in the stopping power of normal tissue, bone, air, etc, the beam range should be confirmed before treatment. A film can be placed on the slope of the phantom to evaluate the Spread-out Bragg Peak based on the water equivalent thickness value of PMMA on the film. In addition, an ionization chamber (Pin-point, PTW 31014) can be inserted into a hole in the phantom to measure the absolute dose. Results: The eye phantom was used for independent patient-specific QA. The differences in the output and beam range between the measurement and the planned treatment were less than 1.5% and 0.1 cm, respectively. Conclusions: An eye phantom was developed and the performance was successfully validated. The phantom can be employed to verify the output and beam range for ocular proton therapy.

Catalytic Characteristics of Perovskite-type Oxides under Mixed Methane and Oxygen Gases (메탄-산소 혼합가스 조건에서의 페롭스카이트계 산화물의 촉매특성 평가)

  • Ahn, Ki-Yong;Kim, Hyoung-Chul;Chung, Yong-Chae;Son, Ji-Won;Lee, Hae-Won;Lee, Jong-Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.4
    • /
    • pp.232-237
    • /
    • 2008
  • As the single chamber SOFC(SC-SOFC) showed higher prospect on reducing the operation temperature as well as offering higher design flexibility of SOFCs, lots of concerns have been given to investigate the catalytic activity of perovskite-type oxide in mixed fuel and oxidant conditions. Hence we thoroughly investigated the catalytic property of various perovskite-type oxides such as $La_{0.8}Sr_{0.2}MnO_3(LSM),\;La_{0.6}Sr_{0.4}CoO_3(LSC),\;La_{0.6}Sr_{0.4}Co_{0.2}Fe_{0.8}O_3(LSCF),\;Sm_{0.5}Sr_{0.5}CoO_3(SSC),\;and\;Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}(BSCF)$ under the partial oxidation condition of methane which used to be given for SC-SOFC operation. In this study, powder form of each perovskite oxides whose surface areas were controlled to be equal, were investigated as functions of methane to oxygen ratios and reactor temperature. XRD, BET and SEM were employed to characterize the crystalline phase, surface area and microstructure of prepared powders before and after the catalytic oxidation. According to the gas phase analysis with flow-through type reactor and gas chromatography system, LSC, SSC, and LSCF showed higher catalytic activity at fairly lower temperature around $400^{\circ}C{\sim}450^{\circ}C$ whereas LSM and BSCF could be activated at much higher temperature above $600^{\circ}C$.

Post-endodontic Restoration on Erupting Permanent First Molars Using Endocrown with a Polyglass Composite Resin: Report of Two Cases (맹출 중인 제1대구치의 근관 치료 후 엔도크라운을 통한 수복 증례 보고)

  • Jeong, Hyuntae;Kim, Seonmi;Kim, Jaehwan;Choi, Namki
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.1
    • /
    • pp.111-118
    • /
    • 2019
  • Post-endodontic restorations are both important and challenging for clinical success in endodontically treated posterior teeth. Several options have been proposed to restore endodontically treated molars. In pediatric dentistry, restoration using conventional single crowns, especially for partially erupted molars with insufficient retentive tooth structure, has proven to be difficult. However, the endocrown presents a conservative and esthetic restorative alternative to conventional crowns with post-and-core, as it acquires additional retention within the pulp chamber. The tooth preparation consists of a circular, equigingival, butt-joint margin and a central retention cavity in the pulp chamber that helps to construct both the crown and core as a single unit. This case report describes the esthetic and conservative endocrown restorations of erupting permanent first molars with extensive coronal destruction.

Study on Internal Ballistic Performance Analysis for Single-chamber Dual-thrust Rocket Motors (단일연소관 이중추력 로켓모터의 내탄도성능 분석법 연구)

  • Kwon, Hyeokmin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.4
    • /
    • pp.1-11
    • /
    • 2020
  • In this study, study on the internal ballistic analysis method for single-chamber dual-thrust rocket motors meeting a dual-thrust profile requirement by tailoring the grain burning area is presented. The analysis method, which can acquire variables required for the performance prediction, considering gradual change of burning rate correction factor and specific impulse in the transition phase, is proposed. Improvements compared to the analysis method in the previous study, which do not consider change in the transition phase, are verified through comparison between the newly proposed method and the method in the previous study. Internal ballistic variables are obtained for four different ground firing test conditions using the proposed method, and the performance prediction for each condition is conducted using these variables. These prediction results and the ground test data are in good agreement, so it is confirmed that the performance prediction of dual-thrust motors with same design geometries based on the proposed analysis method is available.

YBCO coated conductor with a single buffer layer of Yttrium Oxide

  • Park, Chan;Dongqi Shi;Kyujeong Song;Rokkil Ko;Park, Soojeong;Yoo, Sang-Im
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.3
    • /
    • pp.20-22
    • /
    • 2003
  • Y$_2$O$_3$ films were pulsed laser deposited on cube textured Ni and Ni-W substrates to be used as a single buffer layer of YBCO coated conductor. Initial deposition of $Y_2$O$_3$ films was performed in a reducing atmosphere, and subsequent deposition was done in the base pressure of the chamber and oxygen atmosphere. The $Y_2$O$_3$ films have a strong cube texture (The full width at half maximum of the ø-scan of $Y_2$O$_3$ was 8.4 which was the same as that of metal substrate) and smooth crack-free microstructure. The biaxially textured YBCO films (The full width at half maximum of the ø-scan was 10.2) pulsed laser deposited on the $Y_2$O$_3$/metal exhibited Tc(R=0) of 86.5K and Jc of 0.7 MA/cm2 at 77K in self field, representing that the $Y_2$O$_3$ single buffer layer is an efficient diffusion barrier of Ni and thus very promising for the achievement of high-Jc YBCO coated conductor.

Changes of Amino Acid Neurotransmitter Contents in Rat Brain by Toluene Inhalation (톨루엔 흡입이 뇌내 아미노산 신경전달물질 함량에 미치는 영향)

  • 이선희;신대섭;김부영
    • Biomolecules & Therapeutics
    • /
    • v.3 no.1
    • /
    • pp.91-96
    • /
    • 1995
  • The effects of toluene inhalation on the contents of amino acid neurotransmitters in rat brain were investigated and blood toluene concentrations inducing changes of behavior and amino acid neurotransmitter contents in rat brain were observed. Male wistar rats were exposed to toluene vapor (single dose : 1700, 5000 and 10000 ppm for 2 hrs, repeated dose : 1700 and 5000 ppm for 2 hrs/day$\times$6 days). Toluene concentrations in blood and the inhalation chamber were assayed by GC with headspace sampler. HPLC method following PITC derivatization was used to measure the amino acid contents in brain tissues such as frontal cortex, caudate, hippocampus, cerebellum and brain stem. Glutamic acid and aspartic acid levels were increased by single inhalation of toluene (5000 ppm) in all the brain areas assayed in this experiment. In caudate and cerebellum, taurine levels were decreased by single inhalation of low dose toluene (1700 ppm), but increased by repeated administration. At high blood toluene concentration, GABA levels were increased in all the brain areas assayed in this experiment and the increasing extents of inhibitory amino acid contents measured in caudate and hippocampus were greater than those of excitatory amino acids. These results suggest that the changes of amino acid neurotransmitter contents in brain by exposure to toluene may modulate toluene-induced behaviors.

  • PDF