• Title/Summary/Keyword: Single Cell

Search Result 3,845, Processing Time 0.046 seconds

Fuel Cell Generation Systems with Active Clamp Current fed Half Bridge Converter (능동 클램프 전류형 하프 브리지 컨버터를 적용한 연료전지 발전시스템)

  • Jang S. J.;Kim J. T.;Lee T. W.;Lee B. K.;Won C. Y.
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.78-86
    • /
    • 2005
  • Recently, a fuel cell with low voltage and high current output characteristics is remarkable for new generation system. It needs both a dc-dc boost converter and dc-ac inverter to be used in fuel cell generation system. Therefore, this paper presents dc-dc active clamp current-fed half-bridge converter with ZVS for fuel cell generation system. The proposed converter has outstanding advantages over the conventional dc-dc converters with respect to high efficiency and high component utilization. The Fuel Cell generation system consist of active clamp current-fed half-bridge converter to boost the Fuel Cell(PEMFC) voltage(28∼43[Vdc]) to 380[Vdc]. A single phase full-bridge inverter is implemented to produce 220[Vac], 60[Hz] AC outputs.

A cell scheduling of a logically separated buffer in ATM switch (ATM 스위치에서 논리적으로 분할된 버퍼의 셀 스케쥴링)

  • 구창회;나지하;박권철;박광채
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.8
    • /
    • pp.1755-1764
    • /
    • 1997
  • In this paper, we proposed the mechanism for the buffer allocation and a cell scheduling method with logical separation a single buffer in the ATm switch, and analyzed the cell loss probability and the delay of each trafic (CBR/VBR/ABR) based on the weighted value and the dynamic cell service scheduling algorithm. The proposed switch buffering system classifies composite trafics incoming to the switch, according to the characteristic of traffic, then stores them in the logically separated buffers, and adopts the round-robin service with weighted value in order to transmit cells in buffers though one output port. We analyzed 4 cell service scheduling algorithms with dynamic round-robinfor each logically separated service line of a single buffer, in which buffers have the respective weighted values and 3 classes on mixed traffic which characteristized by traffic descriptor. In simulation, using SIMCRIPT II.5., we model the VBR and the ABR traffics as ON/OFF processes, and the CBR traffic as a Poisson processes. As the results of analysis according to the proposed buffer management mechanism and cell service algorithm, we have found that the required QoS of each VC can be quaranteed depends on a scale of weighted values allocated to buffers that changed the weighted values, and cell scheduling algorithm.

  • PDF

Evaluation of Commercial Anion Exchange Membrane for the application to Water Electrolysis (수전해 시스템에 적용하기 위한 상용 음이온교환막의 특성평가)

  • Jun Ho, Park;Kwang Seop, Im;Sang Yong, Nam
    • Membrane Journal
    • /
    • v.32 no.6
    • /
    • pp.496-513
    • /
    • 2022
  • In this study, we sought to verify the applicability of anion exchange membrane water electrolysis system using FAA-3-50, Neosepta-ASE, Sustainion grade T, and Fujifilm type 10, which are commercial anion exchange membranes. The morphology of the commercial membranes and the elements on the surface were analyzed using SEM/EDX to confirm the distribution of functional groups included in the commercial membranes. In addition, mechanical strength and decomposition temperature were measured using UTM and TGA to check whether the driving conditions of the water electrolyte were satisfied. The ion exchange capacity and ion conductivity were measured to understand the performance of anion exchange membranes, and the alkaline resistance of each commercial membrane was checked and durability test was performed because they were driven in an alkaline environment. Finally, a membrane-electrode assembly was manufactured and a water electrolysis single cell test was performed to confirm cell performance at 60℃, 70℃, and 80℃. The long-term cell test was measured 20 cycles at other temperatures to compare water electrolysis performance.

Effects of Slow Freezing on Development of Blastomeres Separated from Mouse Preimplantation Embryos (완만동결이 생쥐 초기배 난할세포의 발달에 미치는 영향)

  • Jin, D.I.
    • Korean Journal of Animal Reproduction
    • /
    • v.24 no.3
    • /
    • pp.263-268
    • /
    • 2000
  • The development of single blastomeres isolated from 2-, 4- and 8-cell mouse embryos and the ability of such blastomeres to survive slow freezing were studied. Of 223, 60 and 188 single blastomeres isolated from 2-, 4- and 8-cell mouse embryos, respectively, 111 blastomeres (49.8%) from 2-cell embryos, 12 blastomeres (20.0%) from 4-cell embryos and blastomeres (16.5) from 8-cell embryos developed into blastocysts after culture for 96 hrs. The recovery rate was 54.2% (65/120), 46.4% (13/28) and 24.3% (17/70) of blastomeres derived from 2-, 4- and 8-cell embryos following freezing and thawing and the survival of frozen-thawed blastomeres was 27.1% (16/59), 36.4% (4/11) and 17.6% (3/17), and respectively. The apparently six normal fetuses were obtained from frozen-thawed blastomere from 2-cell embryos after transferring into the recipients. These results indicate that mouse btastomeres isolated from preimplatation stage embryos can survive storage in liquid nitrogen following slow freezing.

  • PDF

Boost-Half Bridge Single Power Stage PWM DC- DC Converters for PEM-Fuel Cell Stacks

  • Kwon, Soon-Kurl;Sayed, Khairy F.A.
    • Journal of Power Electronics
    • /
    • v.8 no.3
    • /
    • pp.239-247
    • /
    • 2008
  • This paper presents the design of 1 kW prototype high frequency link boost half bridge inverter-fed DC-DC power converters with bridge voltage-doublers suitable for small scale PEM fuel cell systems and associated control schemes. The operation principle of this converter is described using fuel cell modeling and some operating waveforms. The switching mode equivalent circuits are based on simulation results and a detailed circuit operation analysis at soft-switching conditions.

Development of a three-dimensional dynamic model for chemotaxis

  • Song, Jihwan;Kim, Dongchoul
    • Interaction and multiscale mechanics
    • /
    • v.4 no.2
    • /
    • pp.165-171
    • /
    • 2011
  • In this study, we proposed a three-dimensional dynamic model under the diffuse interface description for the single crawling cell. From the developed model, we described the clear evolution processes for crawling neutrophil and assessed the reliable quantitative chemotactic property, which confirmed the high possibility of adequate predictions. To establish the system considering of multiple mechanisms such as, diffusion, chemotaxis, and interaction with surface, a diffuse interface model is employed.

Performance evaluation method for Solid Oxide Fuel Cell (고체 전해질형 연료전지의 특성평가법 연구)

  • Kim, G.Y.;Eom, S.W.;Moon, S.I.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1389-1390
    • /
    • 1997
  • The object of this research is to develop various composing material for Solid Oxide Fuel Cell generation system, and to test single cell performance manufactured. So we try to present a guidance for developing mass power generation system. We concentrated on development of manufacturing process for cathode, anode and electrolyte.

  • PDF

Solar-hydrogen Production by a Monolithic Photovoltaic-electrolytic Cell

  • Jeon, Hyo Sang;Min, Byoung Koun
    • Journal of Electrochemical Science and Technology
    • /
    • v.3 no.4
    • /
    • pp.149-153
    • /
    • 2012
  • Among the various solar-hydrogen production techniques a combination of a photovoltaic (PV) and an electrolytic cell into one single system, a monolithic PV-electrolytic cell, has been suggested as a promising one in terms of efficiency and stability. In this mini-review, we describe our recent efforts on the fabrication of the monolithic PV-electrolytic cell. Particularly, we focus on the electrocatalysts for water oxidation and its fabrication method suitable for a monolithic PV-electrolytic cell. We also introduce proto-type devices with a dye-sensitized solar cell module and an InGaP/GaAs photoelectrodes.

Effects of reactant gases on phosphoric acid fuel cell performance (인산형 연료전지의 발전성능에 미치는 반응기체 영향)

  • 송락현;김창수;신동렬
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.3
    • /
    • pp.374-379
    • /
    • 1996
  • Effects of reactant gas flow rates and starvation on phosphoric acid fuel cell performance were studied. As the reactant gas flow rates increased, the cell performance increased and then the cell maintained constant performance. The optimum flow rates of hydrogen, oxygen and air under galvanostatic condition of 150 mA/cm$_{2}$ are found to be 5cc/min cm$_{2}$ 5cc/min cm$_{2}$ and 15cc/min cm$_{2}$ at room temperature and 1 atm, respectively. Also the open circuit voltage of single cell decreased with increasing oxygen flow rate due probably to the decreased probably to the decreased oxygen pressure in the cathode side. Hydrogen and oxygen starvation resulted in voltage loss of about 5mV and 0-2mV, respectively. The voltage loss was independent of starvation time. These results were discussed from point of view of electrochemical reaction of the cell. (author). 9 refs., 8 figs.

  • PDF