• Title/Summary/Keyword: Simultaneous measurements

Search Result 262, Processing Time 0.027 seconds

Simultaneous Determination of Traces of Platinum and Rhodium by Differential Pulse Polarograpy (펄스 차이 폴라로그래피법에 의한 미량 백금과 로듐의 동시 정량)

  • Czae, Myoung-Zoon;Lee, Chul;Hong, Tae-Kee;Kwon, Young-Soon;Hong, Mi-Jeong
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.1
    • /
    • pp.35-39
    • /
    • 1995
  • Simultaneous measurements of trace platinum and rhodium, based on catalytic reduction of protons by the adsorbed Pt-formazone and Rh-formaldehyde complexes formed in formaldehyde-hydrazine-sulfuric acid medium, were demonstrated. The conditions for the measurements of Pt and Rh both present at trace levels (>10-10 M) were 0.004% (w/v) formaldehyde-0.0012% (w/v) hydrazine-0.75 M sulfuric acid. In this medium method detection limits are 7.3${\times}$10-11 M Pt and 3.2${\times}$10-11 M Rh. And dynamic ranges are 5${\times}$10-10~6${\times}$10-8 M and 1${\times}$10-10∼2${\times}$10-8 M for platinum and rhodium respectively. In the linear dynamic ranges, Rh and Ir interfere platinum in the presence of only 10 and 100 times that of Pt respectively. There are no interferences from other platinum group metal ions for rhodium even in the presence of a 500-fold excess of Ir(IV), a hundredfold excess of platinum.

  • PDF

Simultaneous Analysis of Conazole Fungicides in Garlic by Q-TOF Mass Spectrometer Coupled with a Modified QuEChERS Method

  • Bong, Min-Sun;Yang, Si-Young;Lee, Seung-Ho;Seo, Jung-Mi;Kim, In-Seon
    • Korean Journal of Environmental Agriculture
    • /
    • v.30 no.3
    • /
    • pp.323-329
    • /
    • 2011
  • BACKGROUND: The conazoles, difenoconazole, diniconazole, hexaconazole, penconazole and tetraconazole are a large class of synthetic fungicides used extensively for foliage and seed treatments in agricultural crops. The extensive use of conazoles has brought concerns on the potentiality of environmental contamination and toxicity. Thus studies on the development of methods for monitoring the conazoles are required. METHODS AND RESULTS: A modified quick, easy, effective, rugged and safe (QuEChERS) method was involved in sample preparation. Quadrapole time of flight mass spectrometer (Q-TOF MS) in electron spray ionization (ESI) mode was employed to determine conazoles in garlic samples. The limit of detection (LOD) and limit of quantification (LOQ) of conazoles by Q-TOF-MS ranged from 0.001 to 0.002 mg/L and 0.002 to 0.005 mg/L, respectively. Q-TOF-MS analysis exhibited less than 2.6 ppm error of accurate mass measurements for the detection of conazoles spiked at 0.05 mg/L in garlic matrix. Recovery values of conazoles fortified in garlic samples at 0.02, 0.05 and 0.1 mg/L were between 79.2 and 106.2% with a maximum 11.8% of standard deviation. No detectable conazoles were found in the domestic market samples by using the Q-TOF-MS method. CONCLUSION(s): High degree of confirmation for conazoles by accurate mass measurements demonstrated that Q-TOF-MS analysis combined with a QuEChERS method may be applicable to simultaneous determination of conazoles in garlic samples.

Development of New Stacked Element Piezoelectric Polyvinylidene Fluoride Pressure Sensor for Simultaneous Heartbeat and Respiration Measurements (PVDF 압전소자를 이용한 심장박동 및 호흡수 동시측정센서개발)

  • Park, Chang-Yong;Kweon, Hyun-Kyu;Lee, So-Jin;Manh, Long-Nguyen
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.4
    • /
    • pp.100-108
    • /
    • 2019
  • In this paper, a new stacked element pressure sensor has proposed for heartbeat and respiration measurement. This device can be directly attached to an individual's chest; heartbeat and respiration are detected by the pulsatile vibration and deformation of the chest. A key feature of the device is the simultaneous measurement of heart rate and respiration. The structure of the sensor consists of two stacked elements, in which one element includes one polyvinylidene fluoride (PVDF) thin film bonded on polydimethylsiloxane (PDMS) substrate. In addition, for the measurement and signal processing, the electric circuit and the filter are simply constructed with an OP-amp, resistance, and a capacitor. One element (element1, PDMS) maximizes the respiration signal; the other (element2, PVDF) is used to measure heartbeat. Element1 and element2 had sensitivity of 0.163V/N and 0.209V/N, respectively, and element2 showed improved characteristics compared with element1 in response to force. Thus, element1 and element2 were optimized for measuring respiration heart rate, respectively. Through mechanical and vivo human tests, this sensor shows the great potential to optimize the signals of heartbeat and respiration compared with commercial devices. Moreover, the proposed sensor is flexible, light weight, and low cost. All of these characteristics illustrate an effective piezoelectric pressure sensor for heartbeat and respiration measurements.

An improved extended Kalman filter for parameters and loads identification without collocated measurements

  • Jia He;Mengchen Qi;Zhuohui Tong;Xugang Hua;Zhengqing Chen
    • Smart Structures and Systems
    • /
    • v.31 no.2
    • /
    • pp.131-140
    • /
    • 2023
  • As well-known, the extended Kalman filter (EKF) is a powerful tool for parameter identification with limited measurements. However, traditional EKF is not applicable when the external excitation is unknown. By using least-squares estimation (LSE) for force identification, an EKF with unknown input (EKF-UI) approach was recently proposed by the authors. In this approach, to ensure the influence matrix be of full column rank, the sensors have to be deployed at all the degrees-of-freedom (DOFs) corresponding to the unknown excitation, saying collocated measurements are required. However, it is not easy to guarantee that the sensors can be installed at all these locations. To circumvent this limitation, based on the idea of first-order-holder discretization (FOHD), an improved EKF with unknown input (IEKF-UI) approach is proposed in this study for the simultaneous identification of structural parameters and unknown excitation. By using projection matrix, an improved observation equation is obtained. Few displacement measurements are fused into the observation equation to avoid the so-called low-frequency drift. To avoid the ill-conditioning problem for force identification without collocated measurements, the idea of FOHD is employed. The recursive solution of the structural states and unknown loads is then analytically derived. The effectiveness of the proposed approach is validated via several numerical examples. Results show that the proposed approach is capable of satisfactorily identifying the parameters of linear and nonlinear structures and the unknown excitation applied to them.

Simultaneous Synthesis and Densification of NiSi2 and NiSi2-20vol.%Nb Composite by Field-Activated and Pressure-Assisted Combustion (가압통전 활성연소에 의한 치밀한 NiSi2와 NiSi2-20vol.%Nb 복합재료 제조)

  • Kim, H.C.;Shon, I.J.;Park, C.D.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.14 no.1
    • /
    • pp.1-7
    • /
    • 2001
  • A method to simultaneously synthesize and consolidate the silicide $NiSi_2$ and the composite $NiSi_2$-20vol.%Nb from powders of Ni, Si, and Nb was investigated. Combustion synthesis was carried out under the combined effect of an electric field and mechanical pressure. The final density of the products increased nearly linearly with the applied pressure. Highly dense $NiSi_2$ and $NiSi_2$-20vol.%Nb with relative densities of up to 97% were produced under the simultaneous application of a 60MPa pressure and a 3000A current on the reactant powders. The respective Vickers microhardness values for these materials were 6.0 and 5.8 GPa. From indentation crack measurements, the fracture toughness values for $NiSi_2$ and $NiSi_2$-20vol.%Nb were calculated to be 3.3 and 4.7 $MPa{\cdot}m^{1/2}$, respectively.

  • PDF

Simultaneous Measurement of Strain and Temperature During and After Cure of Unsymmetric Composite Laminate Using Fiber Optic Sensors (비대칭 복합적층판의 성형시 및 성형후 광섬유 센서를 이용한 변형률 및 온도의 동시 측정)

  • 강동훈;강현규;김대현;방형준;홍창선;김천곤
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.05a
    • /
    • pp.244-249
    • /
    • 2001
  • In this paper, we present the simultaneous measurement of the fabricaition strain and temperature during and after cure of unsymmetric composite laminate uising fiber optic sensors. Fiber Bragg grating/extrinsic Fabry-Perot interferometric (FBG/EFPl) hybrid sensors are used to measure those measurands. The characteristic matrix of sensor is analytically derived and measurements can be done without sensor calibration. A wavelength-swept fiber laser is utilized as a light source. FBG/EFPI sensors are embedded in a graphite/epoxy unsymmetric cross-ply composite laminate at different direction and different location. We perform the real time measurement of fabrication strains and temperatures at two points of the composite laminate during cure process in an autoclave. Also, the thermal strains and temperatures of the fabricated laminate are measured in thermal chamber. Through these experiments, we can provide a basis for the efficient smart processing of composite and know the thermal behavior of unsymmetric cross-ply composite laminate.

  • PDF

A Simulation for Robust SLAM to the Error of Heading in Towing Tank (Unscented Kalman Filter을 이용한 Simultaneous Localization and Mapping 기법 적용)

  • Hwang, A-Rom;Seong, Woo-Jae
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.339-346
    • /
    • 2006
  • Increased usage of autonomous underwater vehicle (AUV) has led to the development of alternative navigational methods that do not employ the acoustic beacons and dead reckoning sensors. This paper describes a simultaneous localization and mapping (SLAM) scheme that uses range sonars mounted on a small AUV. The SLAM is one of such alternative navigation methods for measuring the environment that the vehicle is passing through and providing relative position of AUV by processing the data from sonar measurements. A technique for SLAM algorithm which uses several ranging sonars is presented. This technique utilizes an unscented Kalman filter to estimate the locations of the AUV and objects. In order for the algorithm to work efficiently, the nearest neighbor standard filter is introduced as the algorithm of data association in the SLAM for associating the stored targets the sonar returns at each time step. The proposed SLAM algorithm is tested by simulations under various conditions. The results of the simulation show that the proposed SLAM algorithm is capable of estimating the position of the AUV and the object and demonstrates that the algorithm will perform well in various environments.

  • PDF

Mobile Robot Localization and Mapping using a Gaussian Sum Filter

  • Kwok, Ngai Ming;Ha, Quang Phuc;Huang, Shoudong;Dissanayake, Gamini;Fang, Gu
    • International Journal of Control, Automation, and Systems
    • /
    • v.5 no.3
    • /
    • pp.251-268
    • /
    • 2007
  • A Gaussian sum filter (GSF) is proposed in this paper on simultaneous localization and mapping (SLAM) for mobile robot navigation. In particular, the SLAM problem is tackled here for cases when only bearing measurements are available. Within the stochastic mapping framework using an extended Kalman filter (EKF), a Gaussian probability density function (pdf) is assumed to describe the range-and-bearing sensor noise. In the case of a bearing-only sensor, a sum of weighted Gaussians is used to represent the non-Gaussian robot-landmark range uncertainty, resulting in a bank of EKFs for estimation of the robot and landmark locations. In our approach, the Gaussian parameters are designed on the basis of minimizing the representation error. The computational complexity of the GSF is reduced by applying the sequential probability ratio test (SPRT) to remove under-performing EKFs. Extensive experimental results are included to demonstrate the effectiveness and efficiency of the proposed techniques.

Evaluation of Combustion Mechanism of Droplet Cluster in Premixed Spray Flame by Simultaneous Time-Series Measurement (동시 시계열 계측에 의한 예혼합 분무화염 내 유적군 연소기구의 평가)

  • Hwang, Seung-Min
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.6
    • /
    • pp.442-448
    • /
    • 2009
  • To evaluate the combustion mechanism of each droplet cluster downstream of the premixed spray flame, the simultaneous time-series measurements were conducted by using optical measurement system consisting of laser tomography, multi-color integrated Cassegrain receiving optics (MICRO) and phase Doppler anemometer (PDA). Furthermore, the group combustion number of droplet cluster was estimated experimentally, and the combustion mechanism of droplet cluster was examined applying the theoretical analysis. The group combustion number, $G_c$, was experimentally estimated about all droplet cluster verified by planar images, and it was classified into the internal group combustion mode and the external group combustion mode according to the theoretical analysis. It is found that there are cases in which the group combustion number estimated experimentally for droplet cluster agree or disagree with the classification by theoretical analysis. The reason of disagreement is considered due to that the group combustion number was only estimated by the geometrical arrangement of droplets in cluster, and that the actual phenomenon is three-dimensional but the measurement system is two-dimensional.

Simultaneous Quantification of Oleins (triolein, diolein and monoolein) in Mouse Feces using Liquid Chromatography-Electrospray Ionization/Mass Spectrometry

  • Lim, Jong-Hyun;Lee, Jeong-Ae;Jang, Yu-Ra;Chung, He-Sson;Lee, Won-Yong;Chung, Bong-Chul
    • Mass Spectrometry Letters
    • /
    • v.3 no.3
    • /
    • pp.68-73
    • /
    • 2012
  • Fat malabsorption is an important cause of poor growth in infancy and childhood. Steatorrhea tests have been developed using various methods. Traditional measurements of stool fat, however, require large samples and it often takes as a week to complete the analysis. In this paper, a liquid chromatography-electrospray ionization/mass spectrometry (LC-ESI/MS) method was developed for simultaneous quantitative analysis of triacylglycerols, triolein, diolein and monoolein, in mouse feces. Moreover, the procedure was rapid, simple as well as compatible with LC-ESI/MS. Chloroform-isopropyl alcohol solution was used for fat-soluble sample extraction. After centrifugation and filtration, an analytical solution was prepared. Triolein, diolein and monoolein were separated using non-aqueous reversed-phase column with the mobile phase consisting of A (methanol) and B (acetone-isopropyl alcohol). The precision (% CV) and accuracy (% bias) of the assay were 3.8-14.7% and 85.2-114.9%, respectively. This method has been successfully applied to simultaneous determination of triolein, diolein and monoolein in feces from 30 mice. This method can therefore be applied to measure triacylglycerols in mouse feces accurately and precisely by LC-ESI/MS, thereby helping to predictive biomarker in fat malabsorption and diagnostic research.