• Title/Summary/Keyword: Simultaneous measurements

Search Result 264, Processing Time 0.024 seconds

Soft tissue change of the midface in skeletal class III orthognathic surgery patients (골격성 III급 부정교합자에서 상악골 전진술을 동반한 양악 수술 시 중안면 연조직 형태의 변화)

  • Jung, Jong-Hyun;Kim, Seong-Sik;Son, Woo-Sung;Park, Soo-Byung
    • The korean journal of orthodontics
    • /
    • v.38 no.2
    • /
    • pp.83-94
    • /
    • 2008
  • Purpose: The first objective of this study was to compare the upper midface morpholgy, focusing on the soft tissues, between skeletal Class III maloccusion patients with midfacial depression and the norm. The second objective was to estimate and analyze the change in the upper midface soft tissues following surgical correction with maxillary advancement by Lefort I osteotomy and mandibular setback by bilateral sagittal split osteotomy (BSSRO). Methods: The samples consisted of 34 adult patients (15 males and 12 females) with an average age of 21 years, who had severe anteroposterior discrepancy with midfacial depression. These patients had received presurgical orthodontic treatment and surgical treatment which consisted of simultaneous Lefort I osteotomy and BSSRO. Results: The correlation coefficient between changes in maxillary advancement and changes in Or' (soft tissue orbitale) was 0.599 (p < 0.05). Change in maxillary plane angle and vertical change of the maxilla were not correlated with the change in Or' (p < 0.05). The ratio of soft tissue change in Or' to maxillary advancement was 43.57 %, and 81.54 % in Sn. Regression equations between maxillary movement and Or' were devised. The $r^2$ value was 0.476. Conclusions: The majority of measurements in the upper midface in skeletal Class III maloccusions when compared to the norm, showed significant differences. In Class III malocclusion with midfacial depression, maxillary advancement produces soft tissue change in the upper midface.

The First Photometric Study of NSVS 1461538: A New W-subtype Contact Binary with a Low Mass Ratio and Moderate Fill-out Factor

  • Kim, Hyoun-Woo;Kim, Chun-Hwey;Song, Mi-Hwa;Jeong, Min-Ji;Kim, Hye-Young
    • Journal of Astronomy and Space Sciences
    • /
    • v.33 no.3
    • /
    • pp.185-196
    • /
    • 2016
  • New multiband BVRI light curves of NSVS 1461538 were obtained as a byproduct during the photometric observations of our program star PV Cas for three years from 2011 to 2013. The light curves indicate characteristics of a typical W-subtype W UMa eclipsing system, displaying a flat bottom at primary eclipse and the O'Connell effect, rather than those of an Algol/b Lyrae eclipsing variable classified by the northern sky variability survey (NSVS). A total of 35 times of minimum lights were determined from our observations (20 timings) and the SuperWASP measurements (15 ones). A period study with all the timings shows that the orbital period may vary in a sinusoidal manner with a period of about 5.6 yr and a small semi-amplitude of about 0.008 day. The cyclical period variation can be interpreted as a light-time effect due to a tertiary body with a minimum mass of 0.71 M. Simultaneous analysis of the multiband light curves using the 2003 version of the Wilson-Devinney binary model shows that NSVS 1461538 is a genuine W-subtype W UMa contact binary with the hotter primary component being less massive and the system shows a low mass ratio of q(mc/mh)=3.51, a high orbital inclination of 88.7°, a moderate fill-out factor of 30 %, and a temperature difference of ΔT=412 K. The O'Connell effect can be similarly explained by cool spots on either the hotter primary star or the cool secondary star. A small third-light corresponding to about 5 % and 2 % of the total systemic light in the B and V bandpasses, respectively, supports the third-body hypothesis proposed by the period study. Preliminary absolute dimensions of the system were derived and used to look into its evolutionary status with other W UMa binaries in the mass-radius and mass-luminosity diagrams. A possible evolution scenario of the system was also discussed in the context of the mass vs mass ratio diagram.

The Relationship between Exposure to Benzene and the Excretion of Urinary Trans, Trans-muconic Acid in Petrochemical Factory Turnaround Process Workers (석유화학공장 대정비 작업 근로자의 벤젠 노출과 요중 trans, trans-muconic acid 배설과의 관계)

  • Lee, Seung Min;Won, Jong Uk;Kim, Chi Nyon;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.1
    • /
    • pp.52-58
    • /
    • 2014
  • Objectives: Using laborers participating in the petrochemical factory turnaround process as subjects, this study aims to identify exposure to benzene in the air and examine the relationship between exposure and the excretion of urinary metabolites by measuring concentrations of urinary trans, trans-muconic acid (t,t-MA). Methods: A passive sampler was used to measure the level of benzene in the air. In order to analyze urinary metabolites, the urine of laborers participating in the turnaround process was collected twice daily, both before and after work. In addition, a survey was conducted on work factors and lifestyle habits as factors affecting the concentration of urinary metabolites. Results: During the survey period, benzene was detected in the samples from all workers, and its average concentration was $0.16{\pm}0.22ppm$. The average concentration of t,t-MA after work was $1.20{\pm}1.86mg/g$ creatinine, and the results of analyzing urinary metabolites concentration before and after work showed statistically significant differences(p=0.003). There was also a statistically significant correlation (r=0.52, p=0.002) between benzene in the air and the concentration of after-work urinary t,t-MA. Conclusions: During the turnaround process, the average benzene concentration in workers was $0.16{\pm}0.22ppm$, which was below the exposure limit. However, their average t,t-MA concentration was $1.20{\pm}1.86mg/g$ creatinine, which exceeded the exposure limit of 1mg/g creatinine. The characteristics of turnaround process work require considerations such as underestimating the passive sampler being used and the skin absorption of benzene, and there needs to be a simultaneous assessment of working environment measurements and biological monitoring.

Experimental Study on the Deformation and Failure Behavior of Tono Granite (토노(Tono) 화강암의 변형 및 파괴거동에 관한 실험적 연구)

  • Choi, Jung-Hae;Chae, Byung-Gon
    • The Journal of Engineering Geology
    • /
    • v.22 no.2
    • /
    • pp.173-183
    • /
    • 2012
  • The nature of surface deformation of Tono granite was investigated using a confocal laser scanning microscope (CLSM) under water-saturated stress relaxation conditions. A new apparatus was developed for this experiment, enabling continuous measurements of stress-strain and simultaneous observations of surface deformation by CLSM. The amounts of grain contact deformation and intra-granular surface deformation were calculated using a finite element method. The results reveal that intense grain contact deformation and intra-granular surface deformation occurred during the period of stress relaxation, and that the intensity of this deformation increased with increasing applied stress. Finite element method (FEM) results show that the strain of grain boundary was greater than strain of inter-granular surface. Contour maps of these local strains were compiled for individual grains and their boundaries, revealing intense deformation at the boundaries between biotite and quartz under compressional stress. This result was a consequence of the mechano-chemical effect of biotite and quartz minerals. Biotite in granite has a layered structure of iron-magnesium-aluminum silicate sheets that are weakly bonded together by layers of potassium ions. In contrast, quartz occurs as stable spherical grains.

Development of an Automated and Continuous Analysis System for PM2.5 and Chemical Characterization of the PM2.5 in the Atmosphere at Seoul (자동연속측정시스템 개발 및 이 시스템을 이용한 서울 대기 중 PM2.5의 화학적 조성과 특성에 관한 연구)

  • Lee Bo Kyoung;Kim Young Hoon;Ha Jae Yoon;Lee Dong Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.4
    • /
    • pp.439-458
    • /
    • 2005
  • An automated analysis system for water soluble constituents in $PM_{2.5}$ has been developed. The system consists of a high capacity multi tube diffusion scrubber (MTDS), a low temperature particle impactor (LTPI), and two ion (anion and cation) chromatography (IC) systems. Atmospheric particles have been collected by passing sample air through a thermostated MTDS followed by a LTPI. This system allows simultaneous measurements of soluble ions in $PM_{2.5}$ at 30 minutes interval. At the air sampling flow rate of 1.0L/min, the detection limits of the overall system are in the order of tens of $ng/m^3$. This system has been successfully used for the measurement of particulate components of Seoul air from April 2003 to January 2004. $SO_4^{2-},\;NO_3^-,\;NH_4^+,\;NO_2^-,\;Cl^-,\;Na^+,\;K^+,\;Ca^{2+},\;and\;Mg^{2+}$ are the major ionic species for $PM_{2.5}$ at Seoul. Among them, $SO_4^{2-},\;NO_3^-\;and\;NH_4^+$ are the most abundant ions, contributed up to $86\%$ of the total and the concentrations were higher than those in any other urban sites in the world except for Chinese cities. There are high pollutant episodes which contribute about $15\~20\%$ of annual average values of the major ions. During the episode, the all parcels were transported from the asian continent and $PM_{2.5}$ were significantly neutralized. This suggests that aged and long range transported pollutants caused the high pollutant episodes. They showed a distinct daily and seasonal variations:they showed a peak in the early morning caused by the night-time accumulation of particulate matters. Atmospheric reactions including gas-to-particle reactions and inter-particle reactions and meteorological parameters including relative humidity and ambient temperature were described with related to the $PM_{2.5}$ 5 concentrations. All of the ionic species showed higher concentrations during the spring than those for summer and winter.

Discrepancies and Validation of Ethanol Level Determination with Osmolar Gap Formula in Patients with Suspected Acute Poisoning (급성 중독환자에서 삼투압 계산식으로 추정된 에탄올 농도의 유효성 검증)

  • Jung, Haewon;Lee, Mi Jin;Cho, Jae Wan;Ahn, Jae Yun;Kim, Changho
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.17 no.2
    • /
    • pp.47-57
    • /
    • 2019
  • Purpose: Osmolar gap (OG) has been used for decades to screen for toxic alcohol levels. However, its reliability may vary due to several reasons. We validated the estimated ethanol concentration formula for patients with suspected poisoning and who visited the emergency department. We examined discrepancies in the ethanol level and patient characteristics by applying this formula when it was used to screen for intoxication due to toxic levels of alcohol. Methods: We retrospectively reviewed 153 emergency department cases to determine the measured levels of toxic ethanol ingestion and we calculated alcohol ingestion using a formula based on serum osmolality. Those patients who were subjected to simultaneous measurements of osmolality, sodium, urea, glucose, and ethanol were included in this study. Patients with exposure to other toxic alcohols (methanol, ethylene glycol, or isopropanol) or poisons that affect osmolality were excluded. OG (the measured-calculated serum osmolality) was used to determine the calculated ethanol concentration. Results: Among the 153 included cases, 114 had normal OGs (OG≤14 mOsm/kg), and 39 cases had elevated OGs (OG>14). The mean difference between the measured and estimated (calculated ethanol using OG) ethanol concentration was -9.8 mg/dL. The 95% limits of agreement were -121.1 and 101.5 mg/dL, and the correlation coefficient R was 0.7037. For the four subgroups stratified by comorbidities and poisoning, the correlation coefficients R were 0.692, 0.588, 0.835, and 0.412, respectively, and the mean differences in measurement between the measured and calculated ethanol levels were -2.4 mg/dL, -48.8 mg/dL, 9.4 mg/dL, and -4.7 mg/dL, respectively. The equation plots had wide limits of agreement. Conclusion: We found that there were some discrepancies between OGs and the calculated ethanol concentrations. Addition of a correction factor for unmeasured osmoles to the equation of the calculated serum osmolality would help mitigate these discrepancies.

Analysis of Operation Efficiency in Private University Using the DEA (DEA를 활용한 국내 사립대학 운영 효율성 분석)

  • Bae, Young-Min;Han, Seung-Jo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.67-75
    • /
    • 2021
  • The structure of universities needs to be adjusted and reformed to cope with the decrease in admission resources and the quality of education due to the low birth rate and aging population. Such a policy is receiving much attention. To analyze the relative efficiency of private universities in Korea from the perspective of resource and performance, this study evaluated the efficiency of private university operation by applying a DEA(Data Envelopment Analysis) technique. The DEA measurements were compared with the diagnosis results of the department of education (Government) in 2018. The input and output variables used in the research analysis were utilized by the university's notification materials (public disclosure information). An analysis of the operational efficiency showed that 48% (12 universities) of the 25 DMUs (Decision Making Unit) were efficient for DEA-BCC models and that some of the capacity-building universities were operating efficiently. In addition, the DEA analysis found ways to improve inefficient groups through DEA-Additive results. This paper can be meaningful because it confirmed the relative efficiency of private universities and suggested improvement directions through the DEA method, which is characterized by the simultaneous consideration of various input and output factors. This will help apply the limited resources related to the input and output elements of each university.

Physical Model Experiment for Estimating Wave Overtopping on a Vertical Seawall under Regular Wave Conditions for On-Site Measurements (현장 월파계측을 위한 규칙파 조건에서 직립식 호안의 월파량 추정에 관한 모형실험)

  • Dong-Hoon Yoo;Young-Chan Lee;Do-Sam Kim;Kwang-Ho Lee
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.35 no.4
    • /
    • pp.75-83
    • /
    • 2023
  • Apart from implementing hardware solutions like raising the crest freeboard of coastal structures to efficiently counter wave-overtopping, there is a simultaneous requirement for software-driven disaster mitigation strategies. These tactics involve the swift and accurate dissemination of wave-overtopping information to the inland regions of coastal zones, enabling the regulation of evacuation procedures and movement. In this study, a method was proposed to estimate wave-overtopping by utilizing the temporal variation of wave heights exceeding the structure's crown level, with the aim of developing an on-site wave measurement system for providing wave-overtopping information in the field. Laboratory model experiments were conducted on vertical seawall structures to measure wave-overtopping volumes and wave runup heights under different wave conditions and structural freeboard variations. By assuming that the velocity of water inundation on the top of the structure during wave-overtopping events is equivalent to the long-wave velocity, an overtopping discharge coefficient was introduced. This coefficient was utilized to estimate the rate of wave-overtopping based on the temporal changes in wave runup heights measured at the top of the structure. Upon reasonably calculating the overtopping discharge coefficient, it was verified that the estimation of wave-overtopping could be achieved solely based on the wave runup heights.

A Simple Design of an Imaging System for Accurate Spatial Mapping of Blood Oxygen Saturation Using a Single Element of Multi-wavelength LED (혈중 산소 포화도의 정확한 공간 매핑을 위한 다중 파장 LED 단일소자를 활용한 이미징 시스템 설계)

  • Jun Hwan Kim;Gi Yeon Yu;Ye Eun Song;Chan Yeong Yu;Yun Chae Jang;Riaz Muhammad;Kay Thwe Htun;Ahmed Ali;Seung Ho Choi
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.6
    • /
    • pp.450-464
    • /
    • 2023
  • Pulse oximetry, a non-invasive technique for evaluating blood oxygen saturation, conventionally depends on isolated measurements, rendering it vulnerable to factors like illumination profile, spatial blood flow fluctuations, and skin pigmentation. Previous efforts to address these issues through imaging systems often employed red and near-infrared illuminations with distinct profiles, leading to inconsistent ratios of transmitted light and the potential for errors in calculating spatial oxygen saturation distributions. While an integrating sphere was recently utilized as an illumination source to achieve uniform red and near-infrared illumination profiles on the sample surface, its bulkiness presented practical challenges. In this work, we have enhanced the pulse oximetry imaging system by transitioning illumination from an integrating sphere to a multi-wavelength LED configuration. This adjustment ensures simultaneous emission of red and near-infrared light from the same position, creating a homogeneous illumination profile on the sample surface. This approach guarantees consistent patterns of red and near-infrared illuminations that are spatially uniform. The sustained ratio between transmitted red and near-infrared light across space enables precise calculation of the spatial distribution of oxygen saturation, making our pulse oximetry imaging system more compact and portable without compromising accuracy. Our work significantly contributes to obtaining spatial information on blood oxygen saturation, providing valuable insights into tissue oxygenation in peripheral regions.

The Analysis of Blood Glucose Level Difference According to the Exact Use of Blood Glucose Measurement Test Strips in $^{18}F$-FDG Wholebody PET ($^{18}F$-FDG를 이용한 전신 PET 검사에서 혈당 측정 검사지의 정확한 사용에 따른 혈당 수치의 차이 분석)

  • Park, Soon-Ki;Lee, Nam-Ki;NamGung, Chang-Kyung;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.100-103
    • /
    • 2010
  • Purpose: $^{18}F$-FDG wholebody PET is to evaluate the tumor using glucose metabolism. The blood glucose level is important factor that affects on a result of examination. High glucose levels may interfere with tumor targeting due to competitive inhibition of FDG uptake by D-glucose. The blood glucose level measurement test strips used in the blood glucose measurement are classified into the capillary blood measurement test strips and general purpose measurement test strips that can measure the venous blood and capillary blood altogether depends on cases. The purpose of the study was to compare the blood glucose measurements between simultaneously obtained capillary and venous blood samples using the capillary blood measurement test strips, general purpose measurement test strips. Materials and Methods: A total of 46 subjects (32 males, 14 females) with a mean age of $57.3{\pm}12.3$ years were enrolled. The blood glucose estimation was performed with a Optium Xceed Glucometer (Abbott). Simultaneous capillary and venous blood samples were obtained from each subject. The blood glucose levels were measured using the capillary blood measurement test strips and general purpose measurement test strips. The capillary and venous measurements were compared using a pared t-test. Results: The mean capillary and venous glucose values using the general purpose measurement test strips were $95.2{\pm}12.4$ mg/dL and $104.1{\pm}14.4$ mg/dL, giving a statistically significant difference (p<0.001) between the mean values for the capillary and venous glucose samples (9.0 mg/dL; 95% confidence interval (CI) -11.2 to -6.7). The mean capillary and venous glucose values using the capillary blood measurement test strips were $91.5{\pm}13.6$ mg/dL and $108.6{\pm}16.2$ mg/dL, giving a statistically significant difference (p<0.001) between the mean values for the capillary and venous glucose samples (16.6 mg/dL; 95% CI -20.2 to -13.0). Conclusion: When measuring the blood glucose level before $^{18}F$-FDG PET examination, since the incorrect blood glucose level can be measured, it should note to measure the blood glucose level of the venous blood by the capillary blood measurement test strips. Therefore the measurement variation can be reduced to fulfill the standardized measurement procedure with the suitable measurement test strips, the preparation of the PET examination will be able to be clearly confirmed. In addition, the standardized procedure of the following measurement on the area which is same at all times the blood area in the blood glucose measurement among a capillary or a vein will be needed.

  • PDF