• 제목/요약/키워드: Simultaneous detection

검색결과 755건 처리시간 0.023초

Monte-Carlo simulation for detecting neutron and gamma-ray simultaneously with CdZnTe half-covered by gadolinium film

  • J. Byun ;J. Seo ;Y. Kim;J. Park;K. Shin ;W. Lee ;K. Lee ;K. Kim;B. Park
    • Nuclear Engineering and Technology
    • /
    • 제55권3호
    • /
    • pp.1031-1035
    • /
    • 2023
  • Neutron is an indirectly ionizing particle without charge, which is normally measured by detecting reaction products. Neutron detection system based on measuring gadolinium-converted gamma-rays is a good way to monitor the neutron because the representative prompt gamma-rays of gadolinium have low energies (79, 89, 182, and 199 keV). Low energy gamma-rays and their high attenuation coefficient on materials allow the simple design of a detector easier to manufacture. Thus, we designed a cadmium zinc telluride detector to investigate feasibility of simultaneous detection of gamma-rays and neutrons by using the Monte-Carlo simulation, which was divided into two parts; first was gamma-detection part and second was gamma- and neutron-simultaneous detection part. Consequently, we confirmed that simultaneous detection of gamma-rays and neutrons could be feasible and valid, although further research is needed for adoption on real detection.

Development of Single-tube Multiplex Immunocapture RT-PCR Assay for Simultaneous Detection of Two Pepper Tobamoviruses

  • Kim, Jae-Hyun;Choi, Gug-Seoun;Kim, Jeong-Soo;Lee, Sin-Ho;Choi, Jang-Kyung;Ryu, Ki-Ryun
    • The Plant Pathology Journal
    • /
    • 제22권2호
    • /
    • pp.164-167
    • /
    • 2006
  • An immunocapture reverse transcription-polymerase chain reaction (IC/RT-PCR) was developed for simultaneous detection of two pepper-infecting RNA viruses, Pepper mud mottle virus (PMMoV) and Tobacco mild green mosaic virus (TMGMV). The assay could be performed in a single tube for simultaneous and sensitive detection of these tobamoviruses. This detection system revealed thousand-fold increase in detection sensitivity compare to ELISA. This method could save time and reagent cost compare to common RT-PCR which needs several reactions and several procedures of viral RNA extractions for the same number of samples.

Simultaneous Detection of Listeria monocytogenes, Escherichia coli O157:H7, Bacillus cereus, Salmonella spp., and Staphylococcus aureus in Low-fatted Milk by Multiplex PCR

  • Kim, Ji-Hyun;Rhim, Seong-Ryul;Kim, Kee-Tae;Paik, Hyun-Dong;Lee, Joo-Yeon
    • 한국축산식품학회지
    • /
    • 제34권5호
    • /
    • pp.717-723
    • /
    • 2014
  • A rapid and specific PCR assay for the simultaneous detection of Listeria monocytogenes, Escherichia coli O157:H7, Bacillus cereus, Salmonella spp., and Staphylococcus aureus in foods was developed to reduce the detection time and to increase sensitivity. Multiplex PCR developed in this study produced only actA, fliC, hbl, invA, ileS amplicons, but did not produce any non-specific amplicon. The primer sets successfully amplified the target genes in the multiplex PCR without any non-specific or additional bands on the other strains. The multiplex PCR assays also amplified some target genes from five pathogens, and multiplex amplification was obtained from as little as 1 pg of DNA. According to the results from the sensitivity evaluation, the multiplex PCR developed in this study detected 10 cells/mL of the pathogens inoculated in milk samples, respectively. The results suggested that multiplex PCR was an effective assay demonstrating high specificity for the simultaneous detection of five target pathogens in food system.

Simultaneous Determination of Ranitidine and Metronidazole at Poly(thionine) Modified Anodized Glassy Carbon Electrode

  • Rahman, Md. Mahbubur;Li, Xiao-Bo;Jeon, Young-Deok;Lee, Ho-Joon;Lee, Soo Jae;Lee, Jae-Joon
    • Journal of Electrochemical Science and Technology
    • /
    • 제3권2호
    • /
    • pp.90-94
    • /
    • 2012
  • A simple and sensitive electrochemical sensor for simultaneous and quantitative detection of ranitidine (RT) and metronidazole (MT) was developed, based on a poly(thionine)-modified anodized glassy carbon electrode (PTH/GCE). The modified electrode showed the excellent electrocatalytic activity towards the reduction of both RT and MT in 0.1M phosphate buffer solution (PBS, pH 7.0). The peak-to-peak separations (${\Delta}E_p$) for the simultaneous detection of RT and MT between the two reduction waves in CV and DPV were increased significantly from ca. 100 mV at anodized GCE, to ca. 550 mV at the PTH/GCE. The reduction peak currents of RT and MT were linear over the range from 35 to $500{\mu}M$ in the presence of 200 and $150{\mu}M$ of RT and MT, respectively. The sensor showed the sensitivity of 0.58 and $0.78{\mu}A/cm^2/{\mu}M$ with the detection limits (S/N = 3) of 1.5 and $0.96{\mu}M$, respectively for RT and MT.

Simultaneous outlier detection and variable selection via difference-based regression model and stochastic search variable selection

  • Park, Jong Suk;Park, Chun Gun;Lee, Kyeong Eun
    • Communications for Statistical Applications and Methods
    • /
    • 제26권2호
    • /
    • pp.149-161
    • /
    • 2019
  • In this article, we suggest the following approaches to simultaneous variable selection and outlier detection. First, we determine possible candidates for outliers using properties of an intercept estimator in a difference-based regression model, and the information of outliers is reflected in the multiple regression model adding mean shift parameters. Second, we select the best model from the model including the outlier candidates as predictors using stochastic search variable selection. Finally, we evaluate our method using simulations and real data analysis to yield promising results. In addition, we need to develop our method to make robust estimates. We will also to the nonparametric regression model for simultaneous outlier detection and variable selection.

A Facile Electrochemical Fabrication of Reduced Graphene Oxide-Modified Glassy Carbon Electrode for Simultaneous Detection of Dopamine, Ascorbic Acid, and Uric Acid

  • Yu, Joonhee;Kim, Tae Hyun
    • Journal of Electrochemical Science and Technology
    • /
    • 제8권4호
    • /
    • pp.274-281
    • /
    • 2017
  • This paper describes the simple fabrication of an electrode modified with electrochemically reduced graphene oxide (ERGO) for the simultaneous electrocatalytic detection of dopamine (DA), ascorbic acid (AA), and uric acid (UA). ERGO was formed on a glassy carbon (GC) electrode by the reduction of graphene oxide (GO) using linear sweep voltammetry. The ERGO/GC electrode was formed by subjecting a GO solution ($1mg\;mL^{-1}$ in 0.25 M NaCl) to a linear scan from 0 V to -1.4 V at a scan rate of $20mVs^{-1}$. The ERGO/GC electrode was characterized by Raman spectroscopy, Fourier transform infrared spectroscopy, contact angle measurements, electrochemical impedance spectroscopy, and cyclic voltammetry. The electrochemical performance of the ERGO/GC electrode with respect to the detection of DA, AA, and UA in 0.1 M PBS (pH 7.4) was investigated by differential pulse voltammetry (DPV) and amperometry. The ERGO/GC electrode exhibited three well-separated voltammetric peaks and increased oxidation currents during the DPV measurements, thus allowing for the simultaneous and individual detection of DA, AA, and UA. The detection limits for DA, AA, and UA were found to be 0.46, 77, and $0.31{\mu}M$ respectively, using the amperometric i-t curve technique, with the S/N ratio being 3.

SIMULTANEOUS FAULT DETECTION AND CONTROL OF LINEAR TIME-INVARIANT SYSTEM VIA DISTURBANCE OBSERVER-BASED CONTROL APPROACH

  • PANG, GUOCHEN;JIAO, YU;ZHANG, HONGZI;CHEN, XIANGYONG;ZHANG, ANCAI;QIU, JIANLONG
    • Journal of applied mathematics & informatics
    • /
    • 제40권1_2호
    • /
    • pp.47-59
    • /
    • 2022
  • This paper concerns the problem of simultaneous fault detection and disturbance reject control(SFDDRC) for a class of linear time-invariant system. In the framework of fault detection, residual generators are required to be robust to disturbances existing in the system. Different from most of the existing simultaneous fault and control(SFDC) methods, SFDDRC rejects the influences of disturbances on residual generators by disturbance observer-based control(DOBC). This not only effectively improves the accuracy of fault detection, but also solves the problem that most of the existing SFDC methods require that the disturbance must be bounded. Finally, a numerical example is given to verify the validity of the method.

Simultaneous identification of damage in bridge under moving mass by Adjoint variable method

  • Mirzaee, Akbar;Abbasnia, Reza;Shayanfar, Mohsenali
    • Smart Structures and Systems
    • /
    • 제21권4호
    • /
    • pp.449-467
    • /
    • 2018
  • In this paper, a theoretical and numerical study on bridge simultaneous damage detection procedure for identifying both the system parameters and input excitation mass, are presented. This method is called 'Adjoint Variable Method' which is an iterative gradient-based model updating method based on the dynamic response sensitivity. The main advantage of proposed method is inclusion of an analytical method to augment the accuracy and speed of the solution. Moving mass is a model which takes into account the inertia effects of the vehicle. This interaction model is a time varying system and proposed method is capable of detecting damage in this variable system. Robustness of proposed method is illustrated by correctly detection of the location and extension of predetermined single, multiple and random damages in all ranges of speed and mass ratio of moving vehicle. A comparison study of common sensitivity and proposed method confirms its efficiency and performance improvement in sensitivity-based damage detection methods. Various sources of errors including the effects of measurement noise and initial assumption error in stability of method are also discussed.

Rugate 구조를 갖는 자립형 다공성 실리콘 박막을 이용한 유기 증기, 압력차, 자기장의 동시 감응 특성 (Simultaneous Detection Properties of Organic Vapor, Pressure Difference and Magnetic Field using a Rugate-structured Free-standing Porous Silicon Film)

  • 한성범;이기원
    • 센서학회지
    • /
    • 제26권3호
    • /
    • pp.186-191
    • /
    • 2017
  • In this study, we investigated the simultaneous detection properties of organic vapor, pressure difference, and magnetic field using a single rugate-structured free-standing porous silicon (RFPS) thin film. Both the wavelength and the intensity of the rugate peaks were changed in the reflectivity spectrum measured at the thin film surface while the organic vapor was exposed to the RFPS thin film. However, when the pressure difference and the magnetic field were exposed to the film, only the rugate peak intensity was changed. Therefore, it is possible to distinguish whether or not the organic vapor is detected by simultaneously changing the rugate peak wavelength and intensity. In addition, a method of distinguishing between the pressure difference and the magnetic field detection signal has been derived by rapidly modulating the direction of the magnetic field. This study shows that it is possible to simultaneously detect and distinguish various objects using a single RFPS thin film, and it is found that porous silicon can be utilized as a sensor sufficiently.

Simultaneous Detection of Cd (II), Pb (II), Cu (II), and Hg (II) Ions in Dye Waste Water Using a Boron Doped Diamond Electrode with DPASV

  • Yoon, Jang-Hee;Yang, Jee-Eun;Kim, Jong-Phil;Bae, Jong-Seong;Shim, Yoon-Bo;Won, Mi-Sook
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권1호
    • /
    • pp.140-145
    • /
    • 2010
  • The simultaneous detection of Cd (II), Pb (II), Cu (II), and Hg (II) ions in aqueous medium using a BDD electrode with DPASV is described. XPS was used to characterize the chemical states of trace metal ions deposited on the BDD electrode surface. Experimental parameters that affect response, such as pH, deposition time, deposition potential, and pulse amplitude were carefully optimized. The detection limits for Cd (II), Pb (II), Cu (II), and Hg (II) ions were 3.5 ppb, 2.0 ppb, 0.1 ppb and 0.7 ppb, respectively. The application of the BDD electrode on the electrochemical pretreatment for the simultaneous metal detection in the dye waste water was also investigated.