• Title/Summary/Keyword: Simultaneous Injection Method

Search Result 76, Processing Time 0.027 seconds

A Study on the Combustion Characteristics of Lean Mixture by Radicals Induced Injection in a Constant Volume Combustor (1) (정적연소기에서 라디칼 유도분사를 이용한 희박혼합기의 연소특성에 관한 연구 (1))

  • 박종상;이태원;하종률;정성식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.2
    • /
    • pp.45-53
    • /
    • 2004
  • An experimental study was carried out to obtain the fundamental data about the effects of radicals induced injection on premixture combustion. A constant volume combustor divided to the sub-chamber and the main chamber was used. The volume of the sub-chamber is set up to occupy less than 1.5% of that of whole combustion chamber. Radial twelve narrow passage holes are arranged between the main chamber and the sub-chamber. The products including radicals generated by spark ignition in the sub-chamber will derive the simultaneous multi-point ignition in the main chamber. While the equivalence ratio of pre-mixture in the main chamber and the sub-chamber is uniform. We have examined the effects of the sub-chamber volume, the diameter of passage hole, and the equivalence ratio on the combustion characteristics by means of burning pressure measurement and flame visualization. In the case of radical ignition method(RI), the overall turning time including the ignition delay became very short and the maximum burning pressure was slightly increased in comparison with those of the conventional spark ignition method(SI), that is, single chamber combustion without the sub-chamber. The combustible lean limit by RI method is extended to more ER=0.25 than that by SI method. Therefore the decrease of every emission including NOx and the improvement of fuel consumption is anticipated due to lean burn.

Sensorless Control of Induction Motors with Simultaneous Estimation of Speed and Rotor Resistance in the Very Low Speed Region (속도와 2차 저항의 동시 추정이 가능한 유도전동기의 극 저속 영역 센서리스 속도제어)

  • 정석권;이진국;유삼상
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.9
    • /
    • pp.552-561
    • /
    • 2004
  • This paper is concerned with a new speed sensorless induction motor scheme which can be successfully applied to at any speed including even zero speed. The proposed method is robust against rotor resistance variations. In addition, simultaneous on-line estimations of speed and rotor resistance are realized based on a feedforward type torque control approach. The rotor flux with a low frequency sinusoidal waveform has been utilized to help the simultaneous estimation for both speed and rotor resistance. The control scheme has no current minor loop to determine voltage references. Since the proposed estimation does not depend on any derivative terms of currents and stator voltages, it offers a good performance at extremely low speed region for sensorless induction motor. Furthermore, the proposed control is simply using motor parameters and stator currents without determining any PI gains for current feedback and any signal injection for the rotor resistance estimation. Finally, both simulation and experimental results are given to show the effectiveness of this method.

The Effects of Simultaneous Hand Washing by Nurse and Child Before IV Injection (아동과 간호사의 손씻기 프로그램이 정맥주사와 관련한 아동의 불안, 동통과 피부손상에 미치는 효과)

  • Lee, Ae-Ran;Park, Min-Im;Lee, Hyo-Soon;Kim, So-Hyun;Park, Jin-Kyong;Kim, Ji-Soo
    • Child Health Nursing Research
    • /
    • v.14 no.2
    • /
    • pp.129-137
    • /
    • 2008
  • Purpose: To examine the effects on skin injury, pain, and anxiety when nurses and children simultaneous wash their hands before IV injections. Method: A nonequivalent control group, non-synchronized design study was used with 61 children. For a month and a half, children in the experimental group(30) following hand-washing guidelines, washed their hands with nurses before IV insertion. Anxiety and pain were observed and recorded during IV insertion using the Anxiety Reaction Scale and FACES pain scale. After 48-72 hours on IV therapy with an arm-board, skin condition was checked by a research assistant according to guidelines for assessing skin injury developed by the researcher. t-test, ${\chi}^2$-test, Pearson correlation, and Kendall's tau b were used to analyze data with the SPSS program. Results: Children who washed their hands with the nurse before IV insertion showed less pain (p =.021) and skin injury (p <.001) compared to the control group. Conclusion: This finding suggests that simultaneous hand washing by nurse and child before IV injection has a strong effect on skin injury caused by arm-boards used to maintain IV therapy as well as on pain during IV insertion. This program demonstrates an effective intervention to prevent skin injuries in children on IV therapy.

  • PDF

The Research on the Simultaneous Examination of Thyroid Uptake Measurement and Thyroid Scan using Attenuation Filter (감쇄필터를 이용한 갑상선섭취율 측정과 갑상선스캔의 동시검사법 연구)

  • Lee, Hyo-Yeong;Kim, Jong-Eon;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.309-313
    • /
    • 2011
  • It is necessary for patients to wait twice for the thyroid examination of thyroid uptake measurement and thyroid scan by using $^{99m}Tc$-pertechnetate. In the study, a method of simultaneous examination of thyroid uptake measurement and thyroid scan by one intravenous injection of $^{99m}Tc$-pertechnetate was suggested by using attenuation filter. As a result, there was a significant correlation between control group and experimental group according to existence of attenuation filter. Consequently, the simultaneous examination of thyroid uptake measurement and thyroid scan by one intravenous injection can be applied clinically.

A study on the process optimization of injection molding for replicability enhancement of micro channel (미세채널 전사성 향상을 위한 사출성형 공정최적화 기초연구)

  • Go, Young-Bae;Kim, Jong-Sun;Yu, Jae-Won;Min, In-Gi;Kim, Jong-Duck;Yoon, Kyung-Hwan;Hwang, Cheul-Jin
    • Design & Manufacturing
    • /
    • v.2 no.1
    • /
    • pp.45-50
    • /
    • 2008
  • Micro channel is to fabricate desired pattern on the polymer substrate by pressing the patterned mold against the substrate which is heated above the glass transition temperature, and it is a high throughput fabrication method for bio chip, optical microstructure, etc. due to the simultaneous large area patterning. However, the bad pattern fidelity in large area patterning is one of the obstacles to applying the hot embossing technology for mass production. In the present study, stamper of cross channel with width $100{\mu}m$ and height $50{\mu}m$ was manufactured using UV-LiGA process. Micro channel was manufactured using stamper manufactured in this study. Also replicability appliance was evaluated for micro channel and factors affected replicability were investigated using Taguchi method.

  • PDF

Performance Enhancement of a Low Speed Axial Compressor Utilizing Simultaneous Tip Injection and Casing Treatment of Groove Type

  • Taghavi-Zenouz, Reza;Behbahani, Mohammad Hosein Ababaf
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.18 no.1
    • /
    • pp.91-98
    • /
    • 2017
  • Performance of a low speed axial compressor is enhanced through a proper configuration of blade row tip injection and casing treatment of groove type. Air injectors were mounted evenly spaced upstream of the blade row within the casing groove and were all aligned parallel to the compressor axis. The groove, which covers all the blade tip chord length, extends all-round the casing circumference. Method of investigation is based on solution of the unsteady form of the Navier-Stokes equations utilizing $k-{\omega}$ SST turbulence model. Extensive parametric studies have been carried out to explore effects of injectors' flow momentums and yaw angles on compressor performance, while being run at different throttle valve setting. Emphasis has been focused on situations near to stall condition. Unsteady numerical analyses for untreated casing and no-injection case for near stall condition provided to discover two well-known criteria for spike stall inception, i.e., blade leading edge spillage and trailing edge back-flow. Final results showed that with only 6 injectors mounted axially in the casing groove and at yaw angle of 15 degrees opposite the direction of the blade row rotation, with a total mass flow rate of only 0.5% of the compressor main flow, surprisingly, the stall margin improves by 15.5%.

A Study on the Mixture Formation Process and Combustion Characteristics According to Injection Timing in Premixed Charge Compression Ignition (예혼합 압축착화 디젤엔진의 분사시기 변화에 따른 혼합기 형성 과정 및 연소 특성에 관한 연구)

  • Cho, Byung-Ho;Han, Yong-Tak;Lee, Ki-Hyung;Lee, Chang-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.12
    • /
    • pp.1692-1698
    • /
    • 2002
  • A diesel engine has various merits such as high thermal-efficiency, superior fuel consumption and durability. Therefore the number of diesel engine in the world is increasing. As the seriousness of environmental pollution increases in the world, the method to reduce the noxious materials of $CO_2$, NOx and P.M. is very important subject to correspond to exhaust gas regulations. A new concept, so called premixed charge diesel combustion(PCCI), is focused among the various corresponding manners. In this study, we investigated the mixture formation within the cylinder with injection timing using GTT simulation code and also compared combustion characteristics of PCCI engine with that of commercial diesel engine. From this experiments, it could be found that homogeneous mixture formation was observed according to advance of injection timing and simultaneous reduction of NOx and Soot in injection timing of BTDC 60$^{\circ}$.

Numerical study on evaluation of grout diffusion range by the conditions of steel pipe reinforced grouting method (강관보강그라우팅 주입 조건에 따른 그라우트 확산 범위 평가에 관한 수치해석적 연구)

  • Jun-Beom An;Gye-Chun Cho;Yuna Lee;Jaewon Lee;Kyeongnam Min;Gukje Jo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.26 no.4
    • /
    • pp.345-363
    • /
    • 2024
  • Steel pipe reinforced grouting method has been widely used to strengthen the crown of tunnel face and prevent groundwater leakage during tunnel excavation. Various injection procedures without sealing have recently been suggested to enhance efficiency. There are two representative injection methods. One is simultaneous injection in segmented batches, and the other is multiple injection using the external packer. The pros and cons of each method were discussed in terms of construction duration and equipment. However, it has yet to be discussed how the injection procedure affects the grout diffusion range in the ground. This study aims to evaluate the grout diffusion range quantitatively by considering the practical grouting sequences. The grout viscosity was measured by laboratory testing. Then, the numerical modeling was structured using the commercial computational fluid dynamics software. Finally, the grout diffusion range affected by the injection procedure and ground conditions was evaluated by performing the numerical parametric study. The results showed that the injection method highly affected the grout diffusion range, especially for inhomogeneous soil. Consequently, it is anticipated that the proper method of steel pipe reinforced grouting will be suggested.

Simultaneous Determination of Methylphenidate, Amphetamine and their Metabolites in Urine using Direct Injection Liquid Chromatography-Tandem Mass Spectrometry

  • Kwon, Woonyong;Suh, SungIll;In, Moon Kyo;Kim, Jin Young
    • Mass Spectrometry Letters
    • /
    • v.5 no.4
    • /
    • pp.104-109
    • /
    • 2014
  • Nonmedical use of prescription stimulants such as methylphenidate (MPH) and amphetamine (AP) by normal persons has been increased to improve cognitive functions. Due to high potential for their abuse, reliable analytical methods were required to detect these prescription stimulants in biological samples. A direct injection liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed and implemented for simultaneous determination of MPH, AP and their metabolites ritalinic acid (RA) and 4-hydroxyamphetamine (HAP) in human urine. Urine sample was centrifuged and the upper layer ($100{\mu}L$) was mixed with $800{\mu}L$ of distilled water and $100{\mu}L$ of internal standards ($0.2{\mu}g/mL$ in methanol). The mixture was then directly injected into the LC-MS/MS system. The mobile phase was composed of 0.2% formic acid in distilled water (A) and acetonitrile (B). Chromatographic separation was performed by using a Capcell Pak MG-II C18 ($150mm{\times}2.0mm$ i.d., $5{\mu}m$, Shiseido) column and all analytes were eluted within 5 min. Linear least-squares regression with a 1/x weighting factor was used to generate a calibration curve and the assay was linear from 20 to 1500 ng/mL (HAP), 40-3000 ng/mL (AP and RA) and 2-150 ng/mL (MPH). The intra- and inter-day precisions were within 16.4%. The intra- and inter-day accuracies ranged from -15.6% to 10.8%. The limits of detection for all the analytes were less than 4.7 ng/mL. The suitability of the method was examined by analyzing urine samples from drug abusers.

Determination of Coccidiostats (Amprolium and Decoquinate) in Cattle and Chicken's Muscle using High Performance Liquid Chromatography

  • Kim, Byung-Ju;Ham, Hyun-Sun;Lee, Jin-Joo;Cheong, Nam-Yong;Myung, Seung-Woon
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.2
    • /
    • pp.559-563
    • /
    • 2012
  • An analytical method for the simultaneous determination of veterinary medicines (amprolium and decoquinate) in cattle and chicken's muscle by HPLC/UV-vis was established. Samples were extracted by a HLB (Hydrophilic-Liphophilic Balance) cartridge with acetonitrile and methanol. Prior to HPLC injection, a mixture solvent (Water:MeOH, 1:1) was utilized as a reconstitution solvent. Chromatographic separation was achieved with a C18 column ($250{\times}4.6mm$, $5{\mu}m$) using gradient elution with 20 mM HFBA and MeOH:ACN (1:1.8). The calibration curves from the spiked blank matrix showed good linearity (above $r^2$=0.997) in the concentration range of $0.13-12.0mg\;kg^{-1}$. The relative recovery (accuracy) and limit of quantitation (LOQ) were in the range of 78.5-107.1% and $0.13-0.42mg\;kg^{-1}$, respectively. The developed method can be used to determine under the MRL (Maximum Residue Limits) levels of veterinary medicines in animal tissues.