Study on cognitive load of OM interface and eye movement experiment for nuclear power system

  • Zhang, Jingling;Su, Daizhong;Zhuang, Yan;QIU, Furong
    • Nuclear Engineering and Technology
    • /
    • v.52 no.1
    • /
    • pp.78-86
    • /
    • 2020
  • The operation and monitoring (OM) interface is the digital medium between nuclear power system and operators. The cognitive load of OM interface has an important effect on the operation errors made by operator during OM task between operator and computer. The cognitive load model of OM interface is constructed for analysing the composition and influencing factors of OM interface cognitive load. And to study the coping strategies and methods for cognitive load of nuclear power system. An experiment method based on eye movement is proposed to measure the cognitive load of OM interface. Experiment case is carried out with 20 subjects and typical OM interface of a nuclear power system simulator. The OM interface is optimized based on the experiment results. And the results comparison between the original OM interface and the optimized OM interface shows that the cognitive load model and proposed method is valuable contributions in reducing the cognitive load and improving the interaction efficiency of OM tasks.

Comparison of alarm systems for advanced control room

  • Lee, H.C.;Oh, I.S.;Sim, B.S.;Koo, I.S.;Kim, J.T.;Lee, K.Y.;Park, J.K
    • Proceedings of the ESK Conference
    • /
    • 1997.10a
    • /
    • pp.303-309
    • /
    • 1997
  • This study is carried out to investigate performance differences between two alarm presentation methods from the viewpoint of human factors and to provide items to be improved. One of the alarm display methods considered in this study displays alarm lists on VDT combined with hardwired alarm panels. The other method displays alarms on plant mimic diagrams of VDT. This alarm display method has other features for operator aid with which operator can get detailed information on the activated alarm in the mimic diagrams, and the capability for alarm processing such as alarm reduction and prioritization. To compare the twodisplay methods, a human factor experiment was performed with a plant simulator in the ITF(Integrated Test Fcility) that plant operators run for 4 event scenarios. During the experiment, physiological measurements, system and operator action log, and audio/video recordings were collected. Operators' subjective opinion was collected as well after the experiment. Time, error rate and situation awareness were major human factor criteria used for the comparison during the analysis stage of the experiment. No statistical significance was found in the results of our statistical comparison analysis. Several findings were identified, however, through the analysis of subjective opinions.

  • PDF

Implementation and Performance Evaluation of the Vector DLL in a Software GPS Receiver (소프트웨어 GPS 수신기에서의 벡터 DLL 구현과 성능 분석)

  • Lim, Deok-Won;Kim, Jeong-Won;Jeong, Ho-Cheol;Hwang, Dong-Hwan;Lee, Sang-Jeong
    • Proceedings of the KIEE Conference
    • /
    • 2008.04a
    • /
    • pp.65-66
    • /
    • 2008
  • A vector DLL represents signal tracking scheme utilizing navigation results, and it has been known that it has better performance than a conventional scalar DLL. This paper discusses the structure and conceptual benefits of the vector DLL, and describes implementation of the vector DLL in a software GPS receive. Also, the benefits of the vector DLL are confirmed by an experiment. Through the experiment, the code tracking accuracy between the vector DLL and a scalar DLL implementation is compared in static environments, and the navigation accuracy is analyzed using GPS signals received from a commercial GPS simulator.

  • PDF

Simulation and Experiment of Dynamic Torsional Vibration during Grid Low Voltage in a PMSG Wind Power Generation System (PMSG 풍력발전시스템에서 전원 저전압 발생시 비틀림 진동 동특성 시뮬레이션 및 실험)

  • Kwon, Sun-Hyung;Song, Seung-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.211-216
    • /
    • 2013
  • A wind generator system model includes wind model, rotor dynamics, synchronous generator, power converter, distribution line and infinite bus. This paper investigates the low-Voltage Ride-Through capability of PMSG wind turbine in a variable speed. The drive train of a wind turbine on 2-mass modeling can observe the shaft torsional vibration when the low-voltage occur. To reduce the torsional vibration when the low-voltage occur, this paper designs suppression control algorithm of the torsional vibration and implements simulation. The simulation based on MATLAB/SIMULINK has validated at the transient state of the PMSG and an experiment using 3kW simulator has validated the LVRT control.

A Study on the Validity of C-V Method for Extracting the Effective Channel Length of MOSFET) (MOSFET의 Effective Channel Length를 추출하기 위한 C-V 방법의 타당성 연구)

  • 이성원;이승준;신형순
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.10
    • /
    • pp.1-8
    • /
    • 2002
  • C- V method is a means to determine the effective channel length for miniaturized MOSFET's. This method achieves L$_{eff}$ by extracting a unique channel length independent extrinsic overlap length($\Delta$L) at a critical gate bias point. In this paper, we conducted an experiment on two different C-V methods. L$_{eff}$ extracted from experiment is compared with L$_{eff}$ simulated from a two-dimensional (2-D) device simulator, and the accuracy of C-V method for L$_{eff}$ extraction is analyzed.

The effects of types of knowledge on the performance of fault diagnosis

  • 함동한;윤완철
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1995.04a
    • /
    • pp.387-394
    • /
    • 1995
  • With respect to the effectiveness of types of knowledge on human diagnostic performance, the results of several experiments claimed that training with diagnostic rules (procedural knowledge) is more effective than training that provides theoretical knowledge (principle knowledge). However, we usually have the idea that understanding the principles of system dynamics is necessary for diagnosis in some situations. In this study, we pointed out some problems in the previous experiments that force to reinterpret their experimental conclusions. Accordingly, we conducted an experiment to reinvestigate the value of theoretical knowledge in two problem situations. A simulator system, which is named DLD, that is to diagnose an electronic device was created for this purpose. It is a context-free digital logic circuit which includes forty-one gates of three basic types. Our experiment investigated the marginal effects of theoretical knowledge over common diagnostic rules. The experimental results showed that the effectiveness of the instruction in theoretical knowledge is dependent on the complexity of diagnostic situations. This adds up an experimental evidence against the presumed ineffectiveness of theoretical knowledge and forward reasoning in fault diagnosis. Furthermore, the result suggests the source of the use of theoretical knowledge.

  • PDF

An Effective Pre-refresh Mechanism for Embedded Web Browser of Mobile Handheld Devices

  • Li Huaqiang;Kim Young-Hak;Kim Tae-Hyung
    • Journal of Korea Multimedia Society
    • /
    • v.7 no.12
    • /
    • pp.1754-1764
    • /
    • 2004
  • Lately mobile handheld devices such as Personal Digital Assistant (PDA) and cellular phones are getting more popular for personal web surfing. However, today most mobile handheld devices have relatively poor web browsing capability due to their low performance so their users have to suffer longer communication latency than those of desktop Personal Computers (PCs). In this paper, we propose an effective pre-refresh mechanism for embedded web browser of mobile handheld devices to reduce this problem. The proposed mechanism uses the idle time to pre-refresh the expired web objects in an embedded web browser's cache memory. It increases the utilization of Central Processing Unit (CPU) power and network bandwidth during the idle time and consequently reduces the client's latency and web browsing cost. An experiment was done using a simulator designed by us to evaluate the efficacy of the proposed mechanism. The experiment result demonstrates that it has a good performance to make web surfing faster.

  • PDF

An agent-based cockpit task management system: a task-oriented pilot-vehicle interface

  • Kim, J.N.
    • Journal of the Ergonomics Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.99-111
    • /
    • 1996
  • In today's highly automated aircraft, the role of the pilot has changed from an airplane controller to a system manager. As a system manager in a cockpit, today's pilot is in charge of a management-level activity called cockpit task management( CTM). According to earlier studies, pilot errors in performing CTM activities were significant factors in a large number of aircraft accidents and incidents. The primary objective of this research was to reduce CTM-related pilot errors. A prototype pilot- vehicle interface called the cockpit task management system (CTMS) was developed and its effectiveness in improving CTM performance was evaluated. After the CTMS was implemented, it was integrated into a PC-based flight simulator to perform an experiment to evaluate its effectiveness. Eight volunteer subjects were used to collect performance data. The results of the experiment indicated that a statistically significant improvement was observed when the subjects flew with the assistance of the CTMS.

  • PDF

A Study on Backscatter Field Reduction of the Curved Aluminum Plate using Active Cancellation Circuit (능동 상쇄 회로를 이용한 곡면 알루미늄 판의 Backscatter Field 감쇄 연구)

  • Kim, Junhwan;Chung, Young-Seek;Cheon, Changyul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.2
    • /
    • pp.276-279
    • /
    • 2015
  • This paper propose a method to reduce the backscatter field of the curved aluminum plate using the cancellation system. The cancellation circuit is composed of a circulator, a LNA(Low Noise Amplifier), a VGA(Variable Gain Amplifier) and two phase shifters. Prior to experiment, we performed simulations to confirm the possibility using FDTD(Finite Difference Time Domain) simulator. We confirmed that the backscatter field could be reduced by the cancellation circuit when we changed the appropriate gain and phase. Finally, we performed an experiment to verify the performance of the cancellation circuit.

3W PV Generation System Development with Solar Tracker (3kW급 추적식 태양광발전 시스템 개발)

  • Kang S.Y.;Park G.N.;Park S.L.;Kim K.H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.687-691
    • /
    • 2003
  • In photovoltaic generation, PV module is used to generate the electricity, and this system has been in limelight as nonpolluting alternative energy source. But, as energy density is low and PV module cost is high, there is a disadvantage that initial investment cost go up. In this study, we studied the method of allowing a tracker, adequate to photovoltaic generation, for Increasing the generating. We determined the proper error angle in order to decrease the repeating number of tracking without a reduction of the generating by using our developed simulator. And, we presented the photovoltaic approach tracking control and achieved its experiment. Through the result of experiment, it is expected that the fault rate and the consumption of electric power in a tracker get reduced and its cost become cut down.