• Title/Summary/Keyword: Simulation tool

Search Result 3,313, Processing Time 0.035 seconds

A Study on the Modeling of Step Voltage Regulator and Energy Storage System in Distribution System Using the PSCAD/EMTDC (PSCAD/EMTDC를 이용한 배전계통의 선로전압조정장치와 전지전력저장장치의 모델링에 관한 연구)

  • Kim, Byungki;Kim, Giyoung;Lee, Jukwang;Choi, Sungsik;Rho, Daeseok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.2
    • /
    • pp.1355-1363
    • /
    • 2015
  • In order to maintain customer voltage within allowable limit($220{\pm}13V$), tap operation of SVR(step voltage regulator) installed in primary feeder could be carried out according to the scheduled delay time(30 sec) of SVR. However, the compensation of BESS(battery energy storage system) is being required because the customer voltages during the delay time of SVR have a difficultly to maintain within allowable limit when PV system is interconnected with primary feeder. Therefore, this paper presents modeling of SVR to regulate voltage with the LDC(line drop compensation) method and modeling of BESS to control active and reactive power bi-directionally. And also, this paper proposes the coordination control modeling between BESS and SVR in order to overcome voltage problems in distribution system. From the simulation results based on the modeling with the PSCAD/EMTDC, it is confirmed that proposed modeling is practical tool for voltage regulation analysis in distribution system.

Development of State of Charge and Life Cycle Evaluation Algorithm for Secondary Battery (이차전지의 상태 감시 및 수명 예측 알고리즘 개발)

  • Park, Jaebeom;Kim, Byeonggi;Song, Seokhwan;Rho, Daeseok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.1
    • /
    • pp.369-377
    • /
    • 2013
  • This paper deals with the state of charge(SOC) and life cycle evaluation algorithm for lead-acid battery, which is essential factor of the electric vehicle(EV) and the stabilization of renewable energy in the smart grid. In order to perform the effective operation of the lead-acid battery, SOC and life cycle evaluation algorithm is required. Specific gravity with the change of electrolyte temperature inside battery case should be obtained to evaluate the SOC of lead-acid battery, however it is difficult to measure the electrolyte temperature of sealed type lead-acid battery. To overcome this problem, this paper proposes the equation of thermal transmission to compensate internal temperature of the lead-acid battery. Also, it is difficult to exactly evaluate the life cycle of battery, depending on the operation conditions of lead-acid battery such as charging and discharging state, self discharging rate and environmental issue. In order to solve the problem, this paper presents the concept for gravity accumulation of charge and discharge cycle, which is the value converted at $20^{\circ}C$. By using the proposed algorithm, this paper propose the test device based on the Labview software. The simulation results show that it is a practical tool for the maintenance of lead-acid battery in the field of industry.

Development of State Diagnosis Algorithm for Performance Improvement of PV System (태양광전원의 성능향상을 위한 상태진단 알고리즘 개발)

  • Choi, Sungsik;Kim, Taeyoun;Park, Jaebeom;Kim, Byungki;Rho, Daeseok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.2
    • /
    • pp.1036-1043
    • /
    • 2014
  • The installation of PV system to the power distribution system is being increased as one of solutions for environmental pollution and energy crisis. Because the output efficiency of PV system is getting decreased because of the aging phenomenon and several operation obstacles, the technology development of output prediction and state diagnosis of PV modules are required in order to improve operation performance of PV modules. The conventional methods for output prediction by considering various parameters and standard test condition values of PV modules may have difficult and complex computation procedure and also their prediction values may produce large error. To overcome these problems, this paper proposes an optimal prediction algorithm and state diagnosis algorithm of PV modules by using least square methods of linear regression analysis. In addition, this paper presents a state diagnosis evaluation system of PV modules based on the proposed optimal algorithms of PV modules. From the simulation results of proposed evaluation system, it is confirmed that the proposed algorithms is a practical tool for state diagnosis of PV modules.

Calibration and Validation of SWAT Model for Long Term Simulation of Runoff and Sediment Transport at the Nakdong River Basin (낙동강유역의 장기 유역 유출 및 유사 모의를 위한 SWAT 모형의 검보정)

  • Lee, Eun-Jung;Jang, Eun-Kyung;Kim, Tae-Keun;Hwang, Man-Ha;Kwon, Yong-Sung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.881-881
    • /
    • 2012
  • 낙동강유역에는 4대강 사업으로 8개의 보가 낙동강 본류에 새롭게 설치되었으며, 따라서 상류로부터 유입되는 유사가 보상류에 퇴적되어 하천제방이나 하천구조물의 안전을 위협할 수 있다. 또한 홍수시에는 농경지의 매몰과 저수지의 퇴적현상이 발생하는 등 유역유사에 의한 다양한 문제가 발생할 수 있으며, 강우로부터 유출되는 유사는 강우사상에 따라 빠르게 변할 수 있으나 수체에 즉각적인 영향을 유발하지 않을 경우 만성적인 특성으로 인해 침전물을 계속 이동시키며 축적되는 문제가 발생한다. 따라서 이러한 문제를 사전에 예측하고 낙동강유역에 대한 유역유사관리 대책마련을 마련하기 위해 유역유출과 유사의 이송 및 퇴적양상을 분석하여 유역관리를 위한 자료를 구축할 필요가 있다. 이러한 기초자료 분석을 위해 활용되는 유역모형 중 SWAT(Soil and Water Assessment Tool) 모형은 장기간 유역 유출로 인한 유사 모의를 수행하는데 가장 많이 활용되는 모형이며, 미국 농무성 농업연구소(USDA Agricultural Research Service, ARS)의 Jeff Amold 등에 의해 개발된 모형이다. SWAT 모형은 장기유출 및 유사 발생에 대한 시 공간적 변화를 모의하는 모형으로 넓은 범위의 유역에 대해 일단위 모의 간격으로 최대 100년까지 모의가 가능한 장기유역 모의에 최적화된 모형이다. 본 논문에서는 SWAT 모형을 이용하여 낙동강유역의 장기 유역 유출 및 유사 모의를 수행하기위해 2004년에서 2009년까지의 유출량 자료와 유량-유사량관계곡선 등을 이용하여 본류 및 지류 유출구 주요지점에 대해 검보정을 수행하고자 한다. 모의의 정확도 향상을 위해 안동댐, 임하댐, 영천댐, 합천댐, 남강댐, 밀양댐 및 낙동강 본류 등 총 7개 유역으로 구분하여 SWAT 모형을 구축하였으며, 각 유역별로 유출량과 유사량에 대하여 각각 보정 및 검증을 수행하였다. 낙동강 본류유역 총 7개의 댐 방류량자료와 20개의 대형하수종말처리장 방류량자료를 이용한 낙동강유역의 유출량 보정 및 검증 결과, 모의치가 실측치를 잘 반영하고 있는 것으로 나타났다. 또한 총 11개 지점의 수위관측소에 대해 유사량 측정 성과를 이용한 유사량 보정 및 검증 결과, 강우시 유사량 모의값은 유출량-유사량관계곡선 식을 잘 반영하였으나, 비강우시에는 모의값이 관계곡선 식의 결과값보다 대체적으로 높게 나타났다.

  • PDF

Evaluation of L-THIA WWW Dimet Runoff Estimation with AMC Adjustment (선행토양함수조건(AMC)을 고려한 L-THIA WWW 직접유출 모의 정확성 평가)

  • Kim, Jonggun;Park, Younshik;Jeon, Ji-Hong;Engel, Bernard A.;Ahn, Jaehun;Park, Young Kon;Kim, Ki-sung;Choi, Joongdae;Lim, Kyoung Jae
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.4
    • /
    • pp.474-481
    • /
    • 2007
  • With population growth, industrialization, and urbanization within the watershed, the hydrologic response changed dramatically, resulting in increases in peak flow with lesser time to peak and total runoff with shortened time of concentration. Infiltration is directly affected by initial soil moisture condition, which is a key element to determine runoff. Influence of the initial soil moisture condition on hydrograph analysis should be evaluated to assess land use change impacts on runoff and non-point source pollution characteristics. The Long-Term Hydrologic Impact Assessment (L-THIA) model has been widely used for the estimation of the direct runoff worldwide. The L-THIA model was applied to the Little Eagle Creek (LEC) watershed and Its estimated direct runoff values were compared with the BFLOW filtered direct runoff values by other researchers. The $R^2$ value Was 0.68 and the Nash-Sutcliffe coefficient value was 0.64. Also, the L-THIA estimates were compared with those separated using optimized $BFI_{max}$ value for the Eckhardt filter. The $R^2$ value and the Nash-Sutcliffe coefficient value were 0.66 and 0.63, respectively. Although these higher statistics could indicate that the L-THIA model is good in estimating the direct runoff reasonably well, the Antecedent Moisture Condition (AMC) was not adjusted in that study, which might be responsible for mismatches in peak flow between the L-THIA estimated and the measured peak values. In this study, the L-THIA model was run with AMC adjustment for direct runoff estimation. The $R^2$ value was 0.80 and the Nash-Sutcliffe coefficient value was 0.78 for the comparison of L-THIA simulated direct runoff with the filtered direct runoff. However there was 42.44% differences in the L-THIA estimated direct runoff and filtered direct runoff. This can be explained in that about 80% of the simulation period is classified as 'AMC I' condition, which caused lower CN values and lower direct runoff estimation. Thus, the coefficients of the equation to adjust CN II to CN I and CN III depending on AMC condition were modified to minimize adjustments impacts on runoff estimation. The $R^2$ and the Nash-Sutcliffe coefficient values increase, 0.80 and 0.80 respectively. The difference in the estimated and filtered direct runoff decreased from 42.44% to 7.99%. The results obtained in this study indicate the AMC needs to be considered for accurate direct runoff estimation using the L-THIA model. Also, more researches are needed for realistic adjustment of the AMC in the L-THIA model.

DUAL BAND SLOT COUPLED MULTIPLE PATCH ANTENNA WITH BROAD BANDWIDTH AND HIGH DIRECTIVITY FOR WIRELESS ACCESS POINT (무선 액세스 포인트용 광대역의 고지향성 이중대역 슬롯 결합 다중 패치안테나)

  • Yeom, Insu;Kang, Seonghun;Jung, Changwon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.3074-3078
    • /
    • 2014
  • We implemented a dual-band slot-coupled patch (SCP) antenna for the external access point (AP) of the wireless local area network (WLAN) band. The antennas consist of two radiators on three layers. The first radiator is a slotted bow tie antenna operating at the 2.4-2.483 GHz band. The second radiator is a patch antenna with parasitic elements operating at 4.095-5.845 GHz. The high gain and broad bandwidth is important element of wireless access. To enhance the bandwidth, a coupled feeding was used in the first radiator and a parasitic patch was used in the second radiator. We used a parasitic patch and chock to improve the directivity and isolation in both radiators. The porposed antenna was designed by EM simulation tool and measured. The S11 of the antenna was less than -11dB (VSWR 1.8:1) at operating frequency. The peak gain was more than 6 dBi in the first antenna and more than 8 dBi in the second antenna.

Development of an Image Processing System for the Large Size High Resolution Satellite Images (대용량 고해상 위성영상처리 시스템 개발)

  • 김경옥;양영규;안충현
    • Korean Journal of Remote Sensing
    • /
    • v.14 no.4
    • /
    • pp.376-391
    • /
    • 1998
  • Images from satellites will have 1 to 3 meter ground resolution and will be very useful for analyzing current status of earth surface. An image processing system named GeoWatch with more intelligent image processing algorithms has been designed and implemented to support the detailed analysis of the land surface using high-resolution satellite imagery. The GeoWatch is a valuable tool for satellite image processing such as digitizing, geometric correction using ground control points, interactive enhancement, various transforms, arithmetic operations, calculating vegetation indices. It can be used for investigating various facts such as the change detection, land cover classification, capacity estimation of the industrial complex, urban information extraction, etc. using more intelligent analysis method with a variety of visual techniques. The strong points of this system are flexible algorithm-save-method for efficient handling of large size images (e.g. full scenes), automatic menu generation and powerful visual programming environment. Most of the existing image processing systems use general graphic user interfaces. In this paper we adopted visual program language for remotely sensed image processing for its powerful programmability and ease of use. This system is an integrated raster/vector analysis system and equipped with many useful functions such as vector overlay, flight simulation, 3D display, and object modeling techniques, etc. In addition to the modules for image and digital signal processing, the system provides many other utilities such as a toolbox and an interactive image editor. This paper also presents several cases of image analysis methods with AI (Artificial Intelligent) technique and design concept for visual programming environment.

Water and mass balance analysis for hydrological model development in paddy fields

  • Tasuku, KATO;Satoko, OMINO;Ryota, TSUCHIYA;Satomi, TABATA
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.238-238
    • /
    • 2015
  • There are demands for water environmental analysis of discharge processes in paddy fields, however, it is not fully understood in nutrients discharge process for watershed modeling. As hydrological processes both surface and ground water and agricultural water managements are so complex in paddy fields, the development of lowland paddy fields watershed model is more difficult than upland watershed model. In this research, the improvement of SWAT (Soil and Water Assessment Tool) model for a paddy watershed was conducted. First, modification of surface inundated process was developed in improved pot hole option. Those modification was evaluated by monitoring data. Second, the monitoring data in river and drainage channel in lowland paddy fields from 2012 to 2014 were analyzed to understand discharge characteristics. As a case study, Imbanuma basin, Japan, was chosen as typical land and water use in Asian countries. In this basin, lowland paddy fields are irrigated from river water using small pumps that were located in distribution within the watershed. Daily hydrological fluctuation was too complex to estimate. Then, to understand surface and ground water discharge characteristics in irrigation (Apr-Aug) and non-irrigation (Sep-Mar) period, the water and material balance analysis was conducted. The analysis was composed two parts, watershed and river channel blocks. As results of model simulation, output was satisfactory in NSE, but uncertainty was large. It would be coming from discharge process in return water. The river water and ground water in paddy fields were exchanged each other in 5.7% and 10.8% to river discharge in irrigation and non-irrigation periods, respectively. Through this exchange, nutrient loads were exchanged between river and paddy fields components. It suggested that discharge from paddy fields was not only responded to rainfall but dynamically related with river water table. In general, hydrological models is assumed that a discharge process is one way from watershed to river. However, in lowland paddy fields, discharge process is dynamically changed. This function of paddy fields showed that flood was mitigated and temporally held as storage in ground water. Then, it showed that water quality was changed in mitigated function in the water exchange process in lowland paddy fields. In future, it was expected that hydrological models for lowland paddy fields would be developed with this mitigation function.

  • PDF

Estimation of Head Loss Coefficients at Surcharged Square Manhole Using Numerical Model (수치모형을 이용한 과부하 사각형 맨홀에서의 손실계수 산정)

  • Kim, Jung-Soo;Lim, Ga-Hui;Rim, Chang-Soo;Yoon, Sei-Eui
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.3
    • /
    • pp.143-150
    • /
    • 2011
  • Energy loss at manholes, often exceeding friction loss of pipes under surcharged flow, is considered as one of the major causes of inundation in urban area. Therefore, it is important to analyze the head losses at manholes, especially in case of surcharged flow. The stream characteristics were analyzed and head loss coefficients were estimated by using the computational fluid dynamics(CFD) model, FLUENT 6.3, at surcharged square manhole in this study. The CFD model was carefully assessed by comparing simulated results with the experimental ones. The study results indicate that there was good agreement between simulation model and experiment. The CFD model was proved to be capable of estimating the head loss coefficients at surcharged manholes. The head loss coefficients with variation of the ratio of manhole width(B) to inflow pipe diameter(d) and variation of the drop height at surcharged square manhole with a straight-path through were calculated using FLUENT 6.3. As the ratio of B/d increases, head loss coefficient increases. The depth and head loss coefficient at manhole were gradually increased when the drop height was more than 5cm. Therefore, the CFD model(Fluent 6.3) might be used as a tool to simulate the water depth, energy losses, and velocity distribution at surcharged square manhole.

A Study on Operation Method of Protection Device for LVDC Distribution Feeder in Light Rail System (경전철용 LVDC 배전계통의 보호기기 운용 방안에 관한 연구)

  • Kang, Min-Kwan;Choi, Sung Sik;Lee, Hu-Dong;Kim, Gi-Yung;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.25-34
    • /
    • 2019
  • Recently, when a fault occurs at a long-distance point in a LVDC (low voltage direct current) distribution feeder in a light rail system, the magnitude of the current can decrease to less than that of the load current of a light rail system. Therefore, proper protection coordination method to distinguish a fault current from a load current is required. To overcome these problems, this paper proposes an optimal algorithm of protection devices for a LVDC distribution feeder in a light rail system. In other words, based on the characteristics of the fault current for ground resistance and fault location, this paper proposes an optimal operation algorithm of a selective relay to properly identify the fault current compared to the load current in a light rail system. In addition, this paper modelled the distribution system including AC/DC converter using a PSCAD/EMTDC S/W and from the simulation results for a real light rail system, the proposed algorithm was found to be a useful and practical tool to correctly identify the fault current and load current.