• Title/Summary/Keyword: Simulated image

검색결과 651건 처리시간 0.027초

Generation of Simulated Geospatial Images from Global Elevation Model and SPOT Ortho-Image

  • Park, Wan Yong;Eo, Yang Dam
    • 한국측량학회지
    • /
    • 제32권3호
    • /
    • pp.217-223
    • /
    • 2014
  • With precise sensor position, attitude element, and imaging resolution, a simulated geospatial image can be generated. In this study, a satellite image is simulated using SPOT ortho-image and global elevation data, and the geometric similarity between original and simulated images is analyzed. Using a SPOT panchromatic image and high-density elevation data from a 1/5K digital topographic map data an ortho-image with 10-meter resolution was produced. The simulated image was then generated by exterior orientation parameters and global elevation data (SRTM1, GDEM2). Experimental results showed that (1) the agreement of the image simulation between pixel location from the SRTM1/GDEM2 and high-resolution elevation data is above 99% within one pixel; (2) SRTM1 is closer than GDEM2 to high-resolution elevation data; (3) the location of error occurrence is caused by the elevation difference of topographical objects between high-density elevation data generated from the Digital Terrain Model (DTM) and Digital Surface Model (DSM)-based global elevation data. Error occurrences were typically found at river boundaries, in urban areas, and in forests. In conclusion, this study showed that global elevation data are of practical use in generating simulated images with 10-meter resolution.

Correlation analysis between rotation parameters and attitude parameters in simulated satellite image

  • Yun, Young-Bo;Park, Jeong-Ho;Yoon, Geun-Won;Park, Jong-Hyun
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2002년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.553-558
    • /
    • 2002
  • Physical sensor model in pushbroom satellite images can be made from sensor modeling by rotation parameters and attitude parameters on the satellite track. These parameters are determined by the information obtained from GPS, INS, or star tracker. Provided from satellite image, an auxiliary data error is connected directly with an error of rotation parameters and attitude parameters. This paper analyzed how obtaining satellite images influenced errors of rotation parameters and attitude parameters. furthermore, for detailed analysis, this paper generated simulated satellite image, which was changed variously by rotation parameters and attitude parameters of satellite sensor model. Simulated satellite image is generated by using high-resolution digital aerial image and DEM (Digital Elevation Model) data. Moreover, this paper determined correlation of rotation parameter and attitude parameters through error analysis of simulated satellite image that was generated by various rotation parameters and attitude parameters.

  • PDF

Simulated Annealing의 수렴속도 개선에 관한 연구 (Fast Simulated Annealing Algorithm)

  • 정철곤;김중규
    • 한국통신학회논문지
    • /
    • 제27권3A호
    • /
    • pp.284-289
    • /
    • 2002
  • 본 논문에서는 MRF(Markov Random field)를 이용해 영상을 분할할 때, 에너지 최적화를 위해 사용되는 simulated annealing의 수렴속도를 개선하는 방법을 제안하였다. Simulated annealing은 잡음이 포함된 영상이나, 텍스쳐 영상에서 좋은 분할 결과를 나타내지만, 수렴속도가 길다는 단점이 있다. 본 논문에서는 수렴속도를 개선하기 위해 픽셀 레이블의 초기값을 픽셀의 intensity에 따라 adaptive하게 부여하여 simulated annealing을 수행하였다. 이 방법으로 모의실험을 수행한 결과, 기존의 방법보다 수렴 속도를 크게 향상시킬 수 있었다.

고해상도 모의위성영상 제작에 관한 연구 (A Study on the Ceneration of Simulated High-Resolution Satellite Images)

  • 윤영보;조우석;박종현;이종훈
    • 대한원격탐사학회지
    • /
    • 제18권6호
    • /
    • pp.327-336
    • /
    • 2002
  • 다양한 분야에서 고해상도 위성영상의 활용도가 높아짐에 따라 많은 고해상도 인공위성이 발사되고 있으며 발사예정에 있다. 본 논문은 DEM과 항공사진영상을 이용하여 임의의 궤도정보와 자세정보를 가지는 인공위성에 대하여 모의위성영상을 제작할 수 있는 두 가지 방법을 제안하였다. 제작된 모의위성영상의 센서모델에서 자세는 변화가 없는 것으로 가정하였고, 투영중심의 위치는 위성의 진행방향에 따라 변화하는 모델을 사용하였다. 또한 자세와 위치에 변화를 준 모의위성영상을 제작하여 입체시 가능성을 실험하였으며, 제작된 모의위성영상의 정확도를 검증하기 위해 공간전방 교회를 이용하여 검증하였다.

연속된 CT-Image를 이용한 고관절 3d 형상의 재구성 및 Simulated Implantation System 구축에 관한 연구 (A Study on 3d Reconstruction and Simulated Implantation of Human Femur Using Consecutive CT-Images)

  • 민경준;김중규;최재봉;최귀원
    • 대한의용생체공학회:의공학회지
    • /
    • 제20권2호
    • /
    • pp.155-164
    • /
    • 1999
  • 본 논문에서는 화상 신호처리 및 컴퓨터 그래픽스 요소기술을 이용하여, 컴퓨터 상에서 인공고관절의 시술절차를 적용해 보기 위한 Simulated Implantation System (이하 SIS)을 소개한다 SIS는 일련의 자동화된 절차에 따라, 골반(pelvis)과의 접촉이 이루어지는 대퇴골의 상단부위인 고관절(femoral head)을 대체하는 과정을 3차원적으로 가상 수행할 수 있으며, 환자의 고관절과 인공고관절간의 정합정도를 수치적으로 해석할 수 있는 기능을 궁극적 목표로 하게 된다. 이를 위해 필수적으로 필요한 CT-Image를 이용한 고관절 영상의 3차원 재구성, 그리고 projection image글 이용한 인공고관절의 3차원 표현기법에 대해 논의하고, 각각에 대응되는 결과물들을 분석해봄으로써 현재 의공학 분야에서 절실히 요구되고 있는, 영상신호처리와 컴퓨터그래픽스를 이용한 SIS의 prototype에 대한 모습을 제시해 보고자 한다

  • PDF

대기보정된 Landsat TM 영상으로부터 모의영상 제작 (Generation of Simulated Image from Atmospheric Corrected Landsat TM Images)

  • 이수봉;라푸히엔;어양담;편무욱
    • 한국측량학회지
    • /
    • 제33권1호
    • /
    • pp.1-9
    • /
    • 2015
  • 원격탐사영상의 기상조건과 계절에 따른 모의는 영상 전처리 단계 중 대기보정 알고리즘의 역방향 구현을 통해 수행될 수 있다. 본 연구는 상용 원격탐사영상처리 프로그램에서 제공되는 대기보정기능으로 보정된 Landsat영상을 특정기상조건이 고려된 대기보정 이전 상태로 모의하는 방법을 실험하였다. 실험에 적용한 방법은 Forster 알고리즘(1984)과 6S RTM (Radiative Transfer Model) 이고, 모의된 결과영상을 특정기상조건의 원영상과 비교하여 일치성을 분석하였다. 6S RTM을 적용한 결과가 Forster 알고리즘보다 일치성이 높았고, 결과연구대상지역 영상으로 모의영상을 제작한 결과, 원영상과의 평균 RMSE of DN difference가 9.35이고, 평균 $R^2$는 0.7이였다. 결과적으로 참조 영상과 계절이 동일하고 시기가 유사한 모의영상 생성 시 실용적 활용 가능성을 입증하였다.

High Spatial Resolution Satellite Image Simulation Based on 3D Data and Existing Images

  • La, Phu Hien;Jeon, Min Cheol;Eo, Yang Dam;Nguyen, Quang Minh;Lee, Mi Hee;Pyeon, Mu Wook
    • 한국측량학회지
    • /
    • 제34권2호
    • /
    • pp.121-132
    • /
    • 2016
  • This study proposes an approach for simulating high spatial resolution satellite images acquired under arbitrary sun-sensor geometry using existing images and 3D (three-dimensional) data. First, satellite images, having significant differences in spectral regions compared with those in the simulated image were transformed to the same spectral regions as those in simulated image by using the UPDM (Universal Pattern Decomposition Method). Simultaneously, shadows cast by buildings or high features under the new sun position were modeled. Then, pixels that changed from shadow into non-shadow areas and vice versa were simulated on the basis of existing images. Finally, buildings that were viewed under the new sensor position were modeled on the basis of open library-based 3D reconstruction program. An experiment was conducted to simulate WV-3 (WorldView-3) images acquired under two different sun-sensor geometries based on a Pleiades 1A image, an additional WV-3 image, a Landsat image, and 3D building models. The results show that the shapes of the buildings were modeled effectively, although some problems were noted in the simulation of pixels changing from shadows cast by buildings into non-shadow. Additionally, the mean reflectance of the simulated image was quite similar to that of actual images in vegetation and water areas. However, significant gaps between the mean reflectance of simulated and actual images in soil and road areas were noted, which could be attributed to differences in the moisture content.

악교정 수술에서 모의 조종된 3차원 전산화 단층촬영상의 응용 (Application of Simulated Three Dimensional CT Image in Orthognathic Surgery)

  • 김형돈;유선국;이경상;박창서
    • 치과방사선
    • /
    • 제28권2호
    • /
    • pp.363-385
    • /
    • 1998
  • In orthodontics and orthognathic surgery. cephalogram has been routine practice in diagnosis and treatment evaluation of craniofacial deformity. But its inherent distortion of actual length and angles during projecting three dimensional object to two dimensional plane might cause errors in quantitative analysis of shape and size. Therefore, it is desirable that three dimensional object is diagnosed and evaluated three dimensionally and three dimensional CT image is best for three dimensional analysis. Development of clinic necessitates evaluation of result of treatment and comparison before and after surgery. It is desirable that patient that was diagnosed and planned by three dimensional computed tomography before surgery is evaluated by three dimensional computed tomography after surgery. too. But Because there is no standardized normal values in three dimension now and three dimensional Computed Tomography needs expensive equipments and because of its expenses and amount of exposure to radiation. limitations still remain to be solved in its application to routine practice. If postoperative three dimensional image is constructed by pre and postoperative lateral and postero-anterior cephalograms and preoperative three dimensional computed tomogram. pre and postoperative image will be compared and evaluated three dimensionally without three dimensional computed tomography after surgery and that will contribute to standardize normal values in three dimension. This study introduced new method that computer-simulated three dimensional image was constructed by preoperative three dimensional computed tomogram and pre and postoperative lateral and postero-anterior cephalograms. and for validation of new method. in four cases of dry skull that position of mandible was displaced and four patients of orthognathic surgery. computer-simulated three dimensional image and actual postoperative three dimensional image were compared. The results were as follows. 1. In four cases of dry skull that position of mandible was displaced. range of displacement between computer-simulated three dimensional images and actual postoperative three dimensional images in co-ordinates values was from -1.8 mm to 1.8 mm and 94% in displacement of all co-ordinates values was from -1.0 mm to 1.0 mm and no significant difference between computer-simulated three dimensional images and actual postoperative three dimensional images was noticed(p>0.05). 2. In four cases of orthognathic surgery patients, range of displacement between computer­simulated three dimensional images and actual postoperative three dimensional images in coordinates values was from -6.7 mm to 7.7 mm and 90% in displacement of all co-ordinates values was from -4.0 to 4.0 mm and no significant difference between computer-simulated three dimensional images and actual postoperative three dimensional images was noticed(p>0.05). Conclusively. computer-simulated three dimensional image was constructed by preoperative three dimensional computed tomogram and pre and postoperative lateral and postero-anterior cephalograms. Therefore. potentiality that can construct postoperative three dimensional image without three dimensional computed tomography after surgery was presented.

  • PDF

Simulated Annealing 알고리즘을 이용한 에지추출 (Edge Detection Using Simulated Annealing Algorithm)

  • 박중순;김수겸
    • 동력기계공학회지
    • /
    • 제2권3호
    • /
    • pp.60-67
    • /
    • 1998
  • Edge detection is the first step and very important step in image analysis. We cast edge detection as a problem in cost minimization. This is achieved by the formulation of a cost function that evaluates the quality of edge configurations. The cost function can be used as a basis for comparing the performances of different detectors. This cost function is made of desirable characteristics of edges such as thickness, continuity, length, region dissimilarity. And we use a simulated annealing algorithm for minimum of cost function. Simulated annealing are a class of adaptive search techniques that have been intensively studied in recent years. We present five strategies for generating candidate states. Experimental results(building image and test image) which verify the usefulness of our simulated annealing approach to edge detection are better than other operator.

  • PDF

Theoretical Study of Scanning Probe Microscope Images of VTe2

  • Park, Sung-Soo;Lee, Jee-Young;Lee, Wang-Ro;Lee, Kee-Hag
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권1호
    • /
    • pp.81-84
    • /
    • 2007
  • Ab initio periodic Hartree-Fock calculations with the full potential and minimum basis set are applied to interpretation of scanning tunneling microscope (STM) and atomic force microscope (AFM) images on 1TVTe2. Our results show that the simulated STM image shows asymmetry while the simulated AFM image shows the circular electron densities at the bright spots without asymmetry of electron density to agree with the experimental AFM image. The bright spots of both the STM and AFM images of VTe2 are associated with the surface Te atoms, while the patterns of bright spots of STM and AFM images are different.