• Title/Summary/Keyword: Simulated Power Line

Search Result 235, Processing Time 0.027 seconds

A Protective Scheme for Wind Farm Interconnected to Distribution System (풍력발전단지가 연계된 배전계통에서의 보호방안)

  • Kim, Kyoung-Ho;Lee, Jong-Beom;Seo, Je-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.478-480
    • /
    • 2002
  • Wind energy can be conversed into electrical power using wind generator. Wind farm is made up of many wind generators, and it is often interconnected into distribution system to supply power for utilities. There are many protection problems on distribution system connected with Wind farm. It can effect on power quality severely when faults are occurred on distribution line or Wind farms. Therefore the correct protective scheme must be set for distribution system which has a Wind farm. In this paper, A wind farm connected into distribution line is simulated with several fault types which can be occurred on distribution line and Wind farm using PSCAD/EMTDC. And this paper proposes necessary relays to protect both sides of distribution system and wind farm.

  • PDF

A Study on Single-Stage High-Power-Factor Electronic Ballast for Discharge Lamps Operating in Critical Conduction Mode (임계모드에서 동작하는 단일 전력단 고역률 방전등용 전자식 안정기에 관한 연구)

  • Seo Cheol-Sik;Park Jae-Wook;Sim Kwang-Yeal;Kim Hae-Jun;Won Jae-Sun;Kim Dong-Hee
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.12
    • /
    • pp.601-608
    • /
    • 2005
  • This paper presents a novel single-stage high-power-factor electronic ballast for fluorescent lamps operating in critical conduction mode. The proposed topology is based on integration of boost converter as power factor corrector(PFC) and a half-bridge high frequency parallel resonant inverter into a single stage. The input stage of the boost converter is operating in critical conduction mode for positive and negative half cycle voltage respectively at line frequency(60Hz). So that a boost converter makes the line current follow naturally the sinusoidal line voltage waveform. The simulated and experimental results for 100W fluorescent lamps operating at 42kHz switching frequency and 220V line voltage have been obtained. This proposed inverter will be able to be practically used as a power supply in various fields as induction heating applications, fluorescent lamp and DC-DC converter etc.

A Study on Capacity Calculation of Power Supply System for Light Rail Transit (경량전철 전력공급시스템의 용량 산정에 관한 연구)

  • 백병산;서광덕;김종구
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.696-703
    • /
    • 2000
  • This paper describes the capacity calculation of power supply system for light Rail Transit Three factors are considered for the design i.e. substation arrangements, line configuration and substation power capacity. In this study, we considered all of them for capacity calculation of power supply system for LRT. At first DC-fed-traction system is introduced on an outline, a characteristics of train and fed network, and design method of substation arrangements. Optimal design procedures are described, and program for capacity calculation of the system is presented. In addition, the computer simulated results are computed with the conventional simple calculation method.

  • PDF

Numerical Study on the Thermal Model of High Power Density Welding (고에너지 밀도용접의 온도특성에 관한 수치해석적 연구)

  • 이성호;고상근
    • Journal of Welding and Joining
    • /
    • v.10 no.2
    • /
    • pp.19-31
    • /
    • 1992
  • A numerical study was performed to investigate the flow field and the heat transfer characteristics occurring in high power density welding which is important in many fields of engineering applications. A two dimensional quasi-steady state of keyhole welding model is simulated by using the finite volume methods. It is shown that the shape of isothermal line is elliptic and the temperature gradient is very steep compared with other welding method and the welding speed has on welding width and observed beam power.

  • PDF

A Study on the Effects of Neutral Current by Unbalanced Load in Two Step Type Pole using KEPCO's Distribution System (한전 배전 계통을 이용한 2단장주의 불평형 부하에 따른 중성선 전류의 영향에 관한 연구)

  • Park, K.W.;Seo, H.C.;Kim, C.H.;Jung, C.S.;Yoo, Y.P.;Lim, Y.H.;Lee, W.J.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.3
    • /
    • pp.465-471
    • /
    • 2007
  • The one step type pole and two step type pole are used in KEPCO's distribution system. The neutral current increases in three-phase four-wire distribution system due to unbalanced load. Usually, power line and communication line are installed at contiguity by effect of topography in Korea. To this end, the damages such as electrostatic induction, electromagnetic induction and harmonic induction generated by induced voltage and current are occured in power line and communication line. This paper calculates the neutral current in KEPCO's distribution system using EMTP by composing various simulated conditions. Also, these results are verified by vector analysis.

Channel Analysis of inside PLC (옥내 전력선 채널 분석)

  • Hong Duc-Pyo;Lee Jin-Mok;Kim Soo-Cheol;Choi Jae-Ho;Hong Hyun-Mun
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.456-458
    • /
    • 2006
  • Power line communication: PLC which easy to install at anywhere near outlet for electric machine. PLC uses transmission line for voltage of which is 60 Hz. Signals don't affect to electric machine in PLC because they are very small voltage. One of the important thing is the processes of adding signal to power line and extracting the signal from power line, the other is to choose the strong modulation method which sends signals long distance without loosing in PLC channel. but PLC channel have very high and variable noise and attenuation and then it is very hard to transmit optimally between the transmitter and the receiver. After all, impedance and noise problems of PLC channel must be overcame. Noises of 2 kinds which are AWGN abd impulse noise and attenuation are orated. To overcome the noise. Recently, Multi-carrier Modulation: MCM methods like as OFDM and DMT which are divide the channel into many sub-channel have been studied. those are powerful communication methods in PLC. In this paper, PLC channels made up of 3 numbers of noise and attenuation are simulated for getting BER by Matlab simulink.

  • PDF

De-noising in Power Line Communication Using Noise Modeling Based on Deep Learning (딥 러닝 기반의 잡음 모델링을 이용한 전력선 통신에서의 잡음 제거)

  • Sun, Young-Ghyu;Hwang, Yu-Min;Sim, Issac;Kim, Jin-Young
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.4
    • /
    • pp.55-60
    • /
    • 2018
  • This paper shows the initial results of a study applying deep learning technology in power line communication. In this paper, we propose a system that effectively removes noise by applying a deep learning technique to eliminate noise, which is a cause of reduced power line communication performance, by adding a deep learning model at the receive part. To train the deep learning model, it is necessary to store the data. Therefore, it is assumed that the existing data is stored, and the proposed system is simulated. we compare the theoretical result of the additive white Gaussian noise channel with the bit error rate and confirm that the proposed system model improves the communication performance by removing the noise.

An Analysis of Influence Between the Power Feeding Line Insulation and Negative Rail Potential for the DC Ground Fault Protection in the Rubber Wheel System (고무차륜시스템에서의 지락보호를 위한 급전선로 절연과 부극전위와의 영향 분석)

  • Jung, Hosung;Shin, Seongkuen;Kim, Hyungchul;Park, Young;Cho, Sanghoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.4
    • /
    • pp.577-583
    • /
    • 2013
  • We have analyzed influence of potential rise in negative bus, which caused by decrease of power feeding line insulation, upon protecting method of DC ground protection device which detecting potential rise between negative bus and ground in order to detect ground fault in the rubber wheel system. For this purpose, we proposed negative potential equation between negative bus and ground and calculated negative potential according to system condition changes by estimating power feeding line insulation changes in steel wheel system and rubber wheel system, and equalizing DC power feeding system when ground fault occurred. Also, in order to estimate negative potential of real system, we modeled the rubber wheel system, and simulated normal status, grounding fault occurrence and power feeding line insulation changes. In normal status, negative potential did not rise significantly regardless of vehicle operation. When ground fault occurred, negative potential rose up over 300V regardless of fault resistance. However, we also observed that negative potential rose when power feeding line insulation dropped down under $1M{\Omega}$. In conclusion, our result shows that in case of rubber wheel system unlike steel wheel system, relay will be prevented maloperation and insulation status observation can be ensured when ground over voltage relay will be set 200V ~ 300V.

The noise impacts of the open bit line and noise improvement technique for DRAM (DRAM에서 open bit line의 데이터 패턴에 따른 노이즈(noise) 영향 및 개선기법)

  • Lee, Joong-Ho
    • Journal of IKEEE
    • /
    • v.17 no.3
    • /
    • pp.260-266
    • /
    • 2013
  • The open bit line is vulnerable to noise compared to the folded bit line when read/write for the DRAM. According to the increasing DRAM densities, the core circuit operating conditions is exacerbated by the noise when it comes to the open bit line 6F2(F : Feature Size) structure. In this paper, the interference effects were analyzed by the data patterns between the bit line by experiments. It was beyond the scope of existing research. 68nm Tech. 1Gb DDR2, Advan Tester used in the experiments. The noise effects appears the degrade of internal operation margin of DRAM. This paper investigates sense amplifier power line splits by experiments. The noise can be improved by 0.2ns(1.3%)~1.9ns(12.7%), when the sense amplifier power lines split. It was simulated by 68nm Technology 1Gb DDR2 modeling.

Experimental Investigation of Differential Line Inductor for RF Circuits with Differential Structure

  • Park, Chang-kun
    • Journal of information and communication convergence engineering
    • /
    • v.9 no.1
    • /
    • pp.11-15
    • /
    • 2011
  • A Differential line inductor is proposed for a differential power amplifier. The proposed differential line inductor is composed of two conventional line inductors rearranged to make the current direction of the two line inductors identical. The proposed line inductor is simulated with a 2.5-D and a 3-D EM simulator to verify its feasibility with the substrate information in a 0.18-${\mu}m$ RF CMOS process. The inductances of various line inductors implemented with printed circuit boards were measured. The feasibility of the proposed line inductor was successfully demonstrated.