• 제목/요약/키워드: Simulated Materials

검색결과 1,266건 처리시간 0.029초

Artificial Intelligence-Based Identification of Normal Chest Radiographs: A Simulation Study in a Multicenter Health Screening Cohort

  • Hyunsuk Yoo;Eun Young Kim;Hyungjin Kim;Ye Ra Choi;Moon Young Kim;Sung Ho Hwang;Young Joong Kim;Young Jun Cho;Kwang Nam Jin
    • Korean Journal of Radiology
    • /
    • 제23권10호
    • /
    • pp.1009-1018
    • /
    • 2022
  • Objective: This study aimed to investigate the feasibility of using artificial intelligence (AI) to identify normal chest radiography (CXR) from the worklist of radiologists in a health-screening environment. Materials and Methods: This retrospective simulation study was conducted using the CXRs of 5887 adults (mean age ± standard deviation, 55.4 ± 11.8 years; male, 4329) from three health screening centers in South Korea using a commercial AI (Lunit INSIGHT CXR3, version 3.5.8.8). Three board-certified thoracic radiologists reviewed CXR images for referable thoracic abnormalities and grouped the images into those with visible referable abnormalities (identified as abnormal by at least one reader) and those with clearly visible referable abnormalities (identified as abnormal by at least two readers). With AI-based simulated exclusion of normal CXR images, the percentages of normal images sorted and abnormal images erroneously removed were analyzed. Additionally, in a random subsample of 480 patients, the ability to identify visible referable abnormalities was compared among AI-unassisted reading (i.e., all images read by human readers without AI), AI-assisted reading (i.e., all images read by human readers with AI assistance as concurrent readers), and reading with AI triage (i.e., human reading of only those rendered abnormal by AI). Results: Of 5887 CXR images, 405 (6.9%) and 227 (3.9%) contained visible and clearly visible abnormalities, respectively. With AI-based triage, 42.9% (2354/5482) of normal CXR images were removed at the cost of erroneous removal of 3.5% (14/405) and 1.8% (4/227) of CXR images with visible and clearly visible abnormalities, respectively. In the diagnostic performance study, AI triage removed 41.6% (188/452) of normal images from the worklist without missing visible abnormalities and increased the specificity for some readers without decreasing sensitivity. Conclusion: This study suggests the feasibility of sorting and removing normal CXRs using AI with a tailored cut-off to increase efficiency and reduce the workload of radiologists.

Correct Closure of the Left Atrial Appendage Reduces Stagnant Blood Flow and the Risk of Thrombus Formation: A Proof-of-Concept Experimental Study Using 4D Flow Magnetic Resonance Imaging

  • Min Jae Cha;Don-Gwan An;Minsoo Kang;Hyue Mee Kim;Sang-Wook Kim;Iksung Cho;Joonhwa Hong;Hyewon Choi;Jee-Hyun Cho;Seung Yong Shin;Simon Song
    • Korean Journal of Radiology
    • /
    • 제24권7호
    • /
    • pp.647-659
    • /
    • 2023
  • Objective: The study was conducted to investigate the effect of correct occlusion of the left atrial appendage (LAA) on intracardiac blood flow and thrombus formation in patients with atrial fibrillation (AF) using four-dimensional (4D) flow magnetic resonance imaging (MRI) and three-dimensional (3D)-printed phantoms. Materials and Methods: Three life-sized 3D-printed left atrium (LA) phantoms, including a pre-occlusion (i.e., before the occlusion procedure) model and correctly and incorrectly occluded post-procedural models, were constructed based on cardiac computed tomography images from an 86-year-old male with long-standing persistent AF. A custom-made closed-loop flow circuit was set up, and pulsatile simulated pulmonary venous flow was delivered by a pump. 4D flow MRI was performed using a 3T scanner, and the images were analyzed using MATLAB-based software (R2020b; Mathworks). Flow metrics associated with blood stasis and thrombogenicity, such as the volume of stasis defined by the velocity threshold ($\left|\vec{V}\right|$ < 3 cm/s), surface-and-time-averaged wall shear stress (WSS), and endothelial cell activation potential (ECAP), were analyzed and compared among the three LA phantom models. Results: Different spatial distributions, orientations, and magnitudes of LA flow were directly visualized within the three LA phantoms using 4D flow MRI. The time-averaged volume and its ratio to the corresponding entire volume of LA flow stasis were consistently reduced in the correctly occluded model (70.82 mL and 39.0%, respectively), followed by the incorrectly occluded (73.17 mL and 39.0%, respectively) and pre-occlusion (79.11 mL and 39.7%, respectively) models. The surfaceand-time-averaged WSS and ECAP were also lowest in the correctly occluded model (0.048 Pa and 4.004 Pa-1, respectively), followed by the incorrectly occluded (0.059 Pa and 4.792 Pa-1, respectively) and pre-occlusion (0.072 Pa and 5.861 Pa-1, respectively) models. Conclusion: These findings suggest that a correctly occluded LAA leads to the greatest reduction in LA flow stasis and thrombogenicity, presenting a tentative procedural goal to maximize clinical benefits in patients with AF.

대구경 상수도관 부식 손상부의 고분자 필러와 복합슬리브 성능 평가 (Performance assessment of polymeric filler and composite sleeve technique for corrosion damage on large-diameter water pipes)

  • 이호민;박정수;박정주;배철호
    • 상하수도학회지
    • /
    • 제37권4호
    • /
    • pp.203-214
    • /
    • 2023
  • In this study, the physical properties and fracture characteristics according to the tensile load are evaluated on the materials of the polymeric filler and carbon fiber-based composite sleeve technique. The polymeric filler and the composite sleeve technique are applied to areas where the pipe body thickness is reduced due to corrosion in large-diameter water pipes. First, the tensile strength of the polymeric filler was 161.48~240.43 kgf/cm2, and the tensile strength of the polyurea polymeric filler was relatively higher than that of the epoxy. However, the tensile strength of the polymeric filler is relatively very low compared to ductile cast iron pipes(4,300 kgf/cm2<) or steel pipes(4,100 kgf/cm2). Second, the tensile strength of glass fiber, which is mainly used in composite sleeves, is 3,887.0 kgf/cm2, and that of carbon fiber is up to 5,922.5 kgf/cm2. The tensile strengths of glass and carbon fiber are higher than ductile cast iron pipe or steel pipe. Third, when reinforcing the hemispherical simulated corrosion shape of the ductile cast iron pipe and the steel pipe with a polymeric filler, there was an effect of increasing the ultimate tensile load by 1.04 to 1.06 times, but the ultimate load was 37.7 to 53.7% compared to the ductile cast iron or steel specimen without corrosion damage. It was found that the effect on the reinforcement of the corrosion damaged part was insignificant. Fourth, the composite sleeve using carbon fiber showed an ultimate load of 1.10(0.61T, 1,821.0 kgf) and 1.02(0.60T, 2,290.7 kgf) times higher than the ductile cast iron pipe(1,657.83 kgf) and steel pipe(2,236.8 kgf), respectively. When using a composite sleeve such as fiber, the corrosion damage part of large-diameter water pipes can be reinforced with same level as the original pipe, and the supply stability can be secured through accident prevention.

우사깔짚에서 발생되는 온실가스 배출량 산정: 모의 실험결과 (Emission Rate of Greenhouse Gases from Bedding Materials of Cowshed Floor: Lab-scale simulation study)

  • 조원실;이진의;박규현;김정대;라창식
    • Journal of Animal Science and Technology
    • /
    • 제55권1호
    • /
    • pp.67-74
    • /
    • 2013
  • 우사바닥깔짚으로부터의 온실가스 배출량을 산정하기 위해 깔짚으로의 분뇨부하량을 정확히 조절할 수 있는 모의우사바닥에서의 깔짚두께별 $CH_4$$N_2O$ 가스 발생량을 조사하였다. 톱밥이 10, 15cm 높이로 깔린 $0.2583m^2$(L 0.63 m${\times}$W 0.41 m) 크기의 우사바닥으로의 한우와 젖소의 분뇨부하는 친환경 축사표준모델의 축사면적과 축종별 일일 분뇨배설량 자료를 기준으로 한우는 $1.586kg/m^2/d$, 젖소는 $3.588kg/m^2/d$로 정하고 24시간 주기로 분뇨를 투입/혼합하면서 깔짚으로부터 발생하는 온실가스 발생량을 조사하였다. 총 12개의 모의우사바닥을 이용하여 모든 실험은 3반복으로 3회에 걸쳐 수행되었다(5~7월, 9~11월, 2~4월). 그 결과 단위면적당 $CH_4$ 발생량은 한우, 젖소 모두에서 깔짚이 두꺼운 경우 적게 발생하는 경향을 보였으나 통계적으로 유의적인 차이가 없었으며(p<0.05), $N_2O$ 발생량의 경우에도 깔짚두께에 따른 차이가 없는 것으로 나타났다. 한우와 젖소를 비교할 때 단위면적당 온실가스 발생량은 젖소가 $CH_4$는 약 7.5배, $N_2O$는 약 1.2배 많았으며 연간 배출되는 $CH_4$는 한우 7.4 g/head/year, 젖소 130.4 g/head/year로 젖소가 한우에 비해 21배 높은 것으로 나타났다. 또한 $N_2O$는 한우 3,267 g/head/year, 젖소 14,719 g/head/year로 젖소가 약 4.5 배 많았으나 배설된 N 대비 $N_2O$-N은 한우 0.2148 kg $N_2O$-N/kg N, 젖소 0.1632 kg $N_2O$-N/kg N으로 오히려 한우가 높았으며 IPCC 2006 GL값 0.07 kg $N_2O$-N/kg N과 비교시 한우는 약 3.07배, 젖소는 약 2.33배 높은 것으로 나타났다.

생물개스 발생시스템을 위한 지하매설콘크리트 다이제스터의 열전달에 관한 연구 (Study on the Heat Transfer Phenomenon around Underground Concrete Digesters for Bigas Production Systems)

  • 김윤기;고재균
    • 한국농공학회지
    • /
    • 제22권1호
    • /
    • pp.53-66
    • /
    • 1980
  • The research work is concerned with the analytical and experimental studies on the heat transfer phenomenon around the underground concrete digester used for biogas production Systems. A mathematical and computational method was developed to estimate heat losses from underground cylindrical concrete digester used for biogas production systems. To test its feasibility and to evaluate thermal parameters of materials related, the method was applied to six physical model digesters. The cylindrical concrete digester was taken as a physical model, to which the model,atical model of heat balance can be applied. The mathematical model was transformed by means of finite element method and used to analyze temperature distribution with respect to several boundary conditions and design parameters. The design parameters of experimental digesters were selected as; three different sizes 40cm by 80cm, 80cm by 160cm and l00cm by 200cm in diameter and height; two different levels of insulation materials-plain concrete and vermiculite mixing in concrete; and two different types of installation-underground and half-exposed. In order to carry out a particular aim of this study, the liquid within the digester was substituted by water, and its temperature was controlled in five levels-35。 C, 30。 C, 25。 C, 20。C and 15。C; and the ambient air temperature and ground temperature were checked out of the system under natural winter climate conditions. The following results were drawn from the study. 1.The analytical method, by which the estimated values of temperature distribution around a cylindrical digester were obtained, was able to be generally accepted from the comparison of the estimated values with the measured. However, the difference between the estimated and measured temperature had a trend to be considerably increased when the ambient temperature was relatively low. This was mainly related variations of input parameters including the thermal conductivity of soil, applied to the numerical analysis. Consequently, the improvement of these input data for the simulated operation of the numerical analysis is expected as an approach to obtain better refined estimation. 2.The difference between estimated and measured heat losses was shown to have the similar trend to that of temperature distribution discussed above. 3.It was found that a map of isothermal lines drawn from the estimated temperature distribution was very useful for a general observation of the direction and rate of heat transfer within the boundary. From this analysis, it was interpreted that most of heat losses is passed through the triangular section bounded within 45 degrees toward the wall at the bottom edge of the digesten Therefore, any effective insulation should be considered within this region. 4.It was verified by experiment that heat loss per unit volume of liquid was reduced as the size of the digester became larger For instance, at the liquid temperature of 35˚ C, the heat loss per unit volume from the 0. 1m$^3$ digester was 1, 050 Kcal/hr m$^3$, while at for 1. 57m$^3$ digester was 150 Kcal/hr m$^3$. 5.In the light of insulation, the vermiculite concrete was consistently shown to be superior to the plain concrete. At the liquid temperature ranging from 15。 C to 350 C, the reduction of heat loss was ranged from 5% to 25% for the half-exposed digester, while from 10% to 28% for the fully underground digester. 6.In the comparison of heat loss between the half-exposed and underground digesters, the heat loss from the former was fr6m 1,6 to 2, 6 times as much as that from the latter. This leads to the evidence that the underground digester takes advantage of heat conservation during winter.

  • PDF

K2CO3 첨가에 따른 H2S 제거용 무기계 흡착제의 흡착성능 영향에 관한 연구 (Effect of K2CO3 Loading on the Adsorption Performance of Inorganic Adsorbent for H2S Removal)

  • 장길남;송영상;홍지숙;유영우;황택성
    • 청정기술
    • /
    • 제23권3호
    • /
    • pp.286-293
    • /
    • 2017
  • 본 연구는 악취가스 물질(바이오가스의 불순물)의 하나인 $H_2S$를 제거하기 위한 흡착제의 성능을 향상시키기 위해 수행하였다. 기본 담체로서 4가지 물질($Fe_2O_3$, $Ca(OH)_2$, 분말 활성탄, $Al(OH)_3)$을 혼합 사용하여 pellet 형태의 흡착제를 제조하였다. 또한, 4가지 물질의 $H_2S$ 흡착에 미치는 영향을 평가한 결과, $Fe_2O_3$와 분말활성탄은 $H_2S$ 흡착성능이 각각 1.5, 2배로 증가하는 것으로 나타났으며 $Ca(OH)_2$$Al(OH)_2$$H_2S$ 흡착성능에는 영향이 없는 것으로 나타났다. 또한 4가지 물질을 기본혼합 담체로 한 후, 활성물질로 KI, KOH, $K_2CO_3$를 선정하여 각각 5 wt% 첨가한 후에 $H_2S$ 흡착성능을 시험한 결과 $K_2CO_3$를 첨가한 흡착제가 가장 성능이 우수한 것으로 나타났다. 또한 $K_2CO_3$를 5 ~ 30 wt%까지 변화시키면서 흡착성능을 확인한 결과, $K_2CO_3$ 함량이 20 wt%까지는 함량과 비례하여 $H_2S$ 흡착성능이 증가하는 것을 확인할 수 있었으나 30 wt%에서는 $H_2S$ 흡착성능 급격히 떨어지는 것을 확인하였다. 또한 $K_2CO_3$ 첨가 함량에 따른 $H_2S$ 흡착성능을 바탕으로 Thomas model을 이용하여 모델링을 실시한 결과에서도 $K_2CO_3$ 함량이 20 wt%까지는 실험값과 모사값이 잘 일치하고 있음을 보여주었다. 이러한 결과들을 바탕으로, 본 연구에서 확인된 활성물질의 종류와 활성물질의 함량을 흡착제 제조에 이용한다면 $H_2S$ 흡착제의 흡착성능 개선뿐만 아니라 흡착제의 사용수명 증대를 기대할 수 있었다.

결찰양식이 교정용 브라켓과 교정선 사이의 마찰력에 미치는 영향 (THE EFFECT OF LIGATION METHOD ON THE FRICTIONAL FORGE BETWEEN ORTHODONTIC BRACKET AND ARCHWIRE)

  • 신현정;권오원;김교한
    • 대한치과교정학회지
    • /
    • 제28권5호
    • /
    • pp.813-823
    • /
    • 1998
  • 마찰력은 치아이동시 활주이동부에 유해한 인자로 인식되어져 왔으나 치아이동에 저항하는 고정원에 있어서는 유리한 인자로 받아들여질 수 있다. 즉 마찰력이 작은 결찰법들을 이용하여 효과적인 치아이동을 도모하는 반면 마찰력이 큰 결찰법들을 이용하여 브라켓의 걸림에 의해 치아이동이 거의 일어나지 않게 하면 고정원을 강화할 수 있다. 인공타액하에서 시간경과에 따른 교정선과 브라켓 사이의 마찰력 변화, 탄성 모듈과 스테인레스 강 결찰선을 이용하여 각각 결찰양식을 달리 하였을 때의 마찰력 변화 그리고 결찰재의 재료를 달리 하였을 때의 마찰력 변화를 알아보기 위하여 .018"x.025" 슬롯의 상악 중절치용 standard edgewise twin 브라켓과 .017"x.022" 스테인레스 강 교정선을 탄성 모듈, .009" 스테인레스 강 결찰선 그리고 .012" 스테인레스 강 결찰선을 이용하여 다양하게 결찰하였다. 또한 통상적인 방법으로 결찰한 탄성 모듈 결찰군을 결찰 직후와 1주 간격으로 4주간 마찰력을 측정하여 다음과 같은 결과를 얻었다. ${\cdot}$탄성 모듈 whole tie시 시간경과에 따른 마찰력은 4주 경과시 가장 높았으나 3주, 2주, 1주, 결찰 직후간에는 통계학적으로 유의한 차이가 없었다 (p>0.n). ${\cdot}$탄성 모듈로 결찰시 마찰력은 twisting tie가 가장 높았고 double overlay tie, whole tie, half tie 순으로 나타났으나 twisting tie와 double overlay tie 간에는 통계학적으로 유의한 차이가 없었다 (p>0.05). ${\cdot}$스테인레스 강 결찰선으로 결찰시 half tie 군이 whole tie 군보다 낮은 마찰력을 보였으며 ligature tying plier로 결찰한 경우가 needle holder로 결찰한 경우보다 더 높았고 .012" 결찰선을 이용한 경우가 .009" 결찰선을 이용한 경우보다 더 높았다 (p<0.05). ${\cdot}$통상적인 방법으로 탄성 모듈과 스테인레스 강 결찰선을 이용하여 결찰한 경우 두 군간에 유의한 차이가 없었다(p>0.05).

  • PDF

투수성 호안의 해수유통을 고려한 유동 수치모델링 (Numerical Hydrodynamic Modeling Incorporating the Flow through Permeable Sea-Wall)

  • 방기영;박성진;김선우;조창우;김태인;송용식;우승범
    • 한국해안·해양공학회논문집
    • /
    • 제25권2호
    • /
    • pp.63-75
    • /
    • 2013
  • 평택 당진항 내항 2공구 수역은 3개의 투수성 호안으로, 그리고 내항 2공구 동측의 투기장 수역은 2개의 투수성 호안으로 둘러싸여 있다. 2010년 5월에 관측된 내항 2공구 외곽호안 내측 수역과 내항 2공구 투기장 내측 수역의 최대조차는 각각 4.70 m와 2.32 m로서, 동시에 호안 외측에서 관측된 최대조차 8.74 m의 54%와 27%에 달한다. 호안 내 외수위차와 내측 수용적 변화율간의 회귀식을 도출하고, 이 식을 이용하여 투수성 호안의 해수 유통량을 매 계산시간마다 산정하는 모듈을 EFDC 모델에 추가하여 아산만의 3차원 해수유동 수치모형을 구축하였다. 2010년 5월 13~27일의 모의기간에 대하여 주요 5개 분조($M_2$, $S_2$, $K_1$, $O_1$, $N_2$)의 합성조석과 아산, 삽교, 남양, 석문방조제의 담수방류량을 실시간으로 입력하여 해수유동을 모의하였다. 2공구 내측과 2공구 투기장 내측에서 평균고조위, 평균해면과 평균저조위의 실측치에 대한 모델치의 skill score는 96~100%로서 매우 양호한 재현율을 보인다. 투수성 호안의 해수유통을 차단한 모의결과와 비교하면, 최강유속은 주수로를 따라 0.05~0.10 m/s 증가하고, 2공구 외곽호안 외측에서 국지적으로 0.1~0.2 m/s 증가한다. 해저면 전단응력은 유속이 강한 주수로에서 0.1~0.4 $N/m_2$의 범위로 증가하고, 2공구 외곽호안 우각부 주변에서 국지적으로 0.4 $N/m_2$ 이상 증가한다. 본 연구에서 적용한 투수성 호안의 해수유통 모의기법은 대규모 투수성 호안이 유지되는 해역에서 물질의 이류 확산과 해저지형의 침식 퇴적 및 호안 주변의 국부 세굴 등을 모의 예측하는데 유용하게 적용될 수 있다.

방사선 조사시 산소가 세포에 미치는 영향의 이론적 분석 (A Theoretical Study for Estimation of Oxygen Effect in Radiation Therapy)

  • Rena J. Lee;HyunSuk Suh
    • 한국의학물리학회지:의학물리
    • /
    • 제11권2호
    • /
    • pp.157-165
    • /
    • 2000
  • 목적: 방사선조사에 의해 형성된 DNA 손상정도가 산소에 의해 변화되는 추세을 이론적 모델을 이용하여 평가 및 분석하였다. 방법 및 대상: Water radiolysis(물의 방사성분해)시 생성되는 유리기 들간의 반응, 손상된 DNA의 형성, 손상의 복구, 및 산소에 의한 손상의 고정들을 시간 미분 방정식을 이용하여 표현하였다. 문헌에 나와 있는 반응상수(rate constants)들은 그대로 사용되었고 알려지지 않은 상수들은 실험에서 얻어진 데이터에서 얻은 곡선을 대입하여 얻었다. 화학반응상수 변화와 산소농도변화에 따른 세포 생존도를 구하였다. 모델을 통해 얻어진 세포 생존도와 방사선량의 상관관계를 세포 생존곡선으로 표시하였다. 산소에 의한 손상의 fixation(고착화)과정과 산소농도가 세포생존에 미치는 영향을 분석하여 보았다. 산소가 세포생존에 미치는 정도를 정량화 하기 위하여 산소증가효과비(Oxygen Ehhancement Ratio, OER)를 계산하여 실험치와 이론치를 비교하였다. 결과: 산소에 대한 민감성 연구에서 DNA생존도는 산소의 농도와 화학반응속도상수에 영향을 받았다. 산소의 농도가 0에서 1.0 $\times$ $10^{7}$ 으로 변화할 때 세포 생존도에는 변화가 없었다. 그러나 1.0 x $10^{7}$ 에서 1.0 $\times$ $10^{10}$ 변화할 경우 세포의 생존률이 감소하였다. 모의연구에서 얻은 OER치는 10% 세포생존시에는 2.32, 45% 세포생존시에는 1.9 이었다. 결론: 산소의 감수성 연구에서 보여주듯이 방정식을 이용하여 얻어진 새포생존곡선은 실험에서 얻어진 세포생존곡선을 재연할 수 있었다 또한 방사선조사시 생성되는 손상된 세포의 양은 산소 반응상수가 가장 크고 산소농도가 증가되는 경우에 증가됨을 알수있었다. 모의연구에서 얻은 산소증가효과비는 세포생존이 low level인 경우 높은 일치성을 보여 주었다 따라서 본 연구는 세포살해시 산소의 효과를 semi-empirical 모델을 사용하여 예측할수 있다는 것을 보여주고 있다.

  • PDF

다중양극 위치민감형 광전자증배관을 위한 위치검출회로 개발 (Development of Position Encoding Circuit for a Multi-Anode Position Sensitive Photomultiplier Tube)

  • 권순일;홍성종;이또우 미끼꼬;윤현석;이건송;심광숙;이준택;이동수;이재성
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권6호
    • /
    • pp.469-477
    • /
    • 2008
  • 목적: 소동물용 PET은 우수한 공간분해 능과, 민감도가 요구된다. 본 연구에서는 256개의 개별적 채널을 4개로 줄여 검출위치를 추정할 수 있는 회로를 설계하고 제작하였으며, 256($16{\times}16$)개의 양극 출력 채널을 가지는 고집적도의 광전자증배관 및 $L_{0.9}GSO$ 섬광결정과 결합하여 그 성능을 검증하였다. 대상 및 방법: 설계한 회로를 제작하기에 맞서 전자회로 시뮬레이션을 통해 성능을 예상하였다. 회로의 검증과 성능분석을 위하여 위치결정회로, H9500(Hamamatsu Photorucs K.K., 일본) 광전자증배관, $1.5{\times}1.5{\times}7.0\;mm^3$ $L_{0.9}GSO$ 섬광결정으로 두 개의 검출단을 제작하고 $3.7{\times}10^5$ Bq의 $^{22}Na$ 방사선원을 사용하여 동시이벤트를 검출하였다. 첫 번째 검출단은 $L_{0.9}GSO\;29{\times}29$ 섬광결정블록을 단층으로 구성하였고, 두 번째 검출단은 $L_{0.9}GSO\;29{\times}29$$28{\times}28$ 섬광결정블록을 x와 y방향으로 각각 섬광결정 단면 길이의 반만큼 오프셋을 두어 접합하였다. 또한 측정된 데이터를 실제 섬광결정 영역으로 보정하기 위하여 섬광결정지도를 구했다. 결과: 평면영상을 통해 각 섬광결정들이 잘 구분되는 것을 확인할 수 있었고, 회로 개선 후 주변부의 섬광결정들이 마지막 줄까지 명백히 구분되었다. 각 섬광결정들의 에너지 분해능은 11.6%(표준편차 1.6)이었다. 결론: 본 연구에서 제안한 위치결정회로는 실험을 통해 소동물용 PET개발에 있어 만족할만한 성능을 보여주었다. 향후 더욱 정밀한 시스템을 제작하기 위해서는 다중양극 광전자증배관의 이득 불균일을 보정하기 위한 연구가 진행되어야 할 것이다.