• Title/Summary/Keyword: Simplified Vector Control

Search Result 34, Processing Time 0.023 seconds

Three Phase Voltage Source Soft Switching Inverter with High Frequency Pulse Current Transformers

  • Inaba, Claudio Y.;Hiraki, Eiji;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.2 no.4
    • /
    • pp.288-296
    • /
    • 2002
  • In this paper, a high frequency transformer - assisted auxiliary active resonant commutated snubber (HFTA-ARCS) for voltage source soft switching pulse width modulated power conversion circuits is presented. A three phase voltage source type soft switching inverter incorporating HFTA-ARCS circuits in its three bridge legs can reduce current rating of auxiliary active power switches and has sensorless simplified control scheme which any specified boost current management is not required for soft switching. Its operation principle and digital control scheme are described and a practical design method of circuit parameters on this HFTA-ARCS circuit is also introduced on the basis of computer simulation. Moreover, this space voltage vector modulated soft switching inverter system with DSP-based digital control scheme Is discussed and its effectiveness is proved on the basis of performance evaluations. The operating performances of this inverter system are also compared with those of conventional three-phase hard switching inverter under practical conditions of specified parameters.

A Fuzzy Predictive Sliding Mode Control for High Performance Induction Motor Position Drives

  • Bayoumi E.H.E.;Nashed M.N.F.
    • Journal of Power Electronics
    • /
    • v.5 no.1
    • /
    • pp.20-28
    • /
    • 2005
  • This paper presents a fuzzy predictive sliding mode control for high performance induction motor position drives. A new simplified inner-loop sliding-mode current control scheme based on a nonlinear mathematical model of an induction motor is introduced. Novel predictive fuzzy logic PI and PID controllers are used in speed and position loops, respectively. Sliding-mode current controllers and fuzzy predictive logic controllers are designed based on indirect vector control. The overall system performance is examined under different dynamic operating conditions. The performance of the drive system is robust and stable, and insensitive to parameters and operating condition variations even though non-exact system parameters are used in the implementation of the proposed controllers.

A New Direct Torque Control Scheme of an Induction Motor Using Duty Ratio Modulation

  • Park, Jeong-Woo;Lee, Dong-Myung
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1223-1231
    • /
    • 2018
  • The direct torque control (DTC) scheme features a simple structure thanks to stator flux-oriented control. It has the advantage of robustness against motor parameters variation since only the stator resistance is involved in the control scheme. On the other hand, the disadvantage of DTC is large torque ripple. To reduce the torque ripple, many studies on DTC-space vector modulation (DTC-SVM) schemes, which modulate the duty ratio with a fixed switching cycle, have been proposed. However, there is the difficulty in obtaining the duty ratio for DTC-SVM. Hence, this paper proposes a new duty ratio selection and stator flux calculation methods for reducing torque ripple. Simulations and experiments were carried out to determine the validity of the proposed method. The proposed scheme has simplified the duty ratio command and achieved the same control performance as the conventional duty ratio modulation method without using the information of motor parameters.

Improvement of Linearized Characteristics for Induction Motor in the Transient State (과도상태에서 유도전동기의 선형화특성 개선에 관한 연구)

  • 윤병도;김민회;정재윤
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.2
    • /
    • pp.164-174
    • /
    • 1990
  • The improvement of linearized characteistics of induction motor control system with field oriented method is presented in this paper. A fully digitally controlled induction motor driver system based on the proposed linear control condition is described. The control system consists of IBM-PC/AT microcomputer, VSI PWM Inverter, and PI controller with softwave. By controlling the torque component, the rated flux component can be kept constant, even in the transient state. It is clearly confirmed by experiment that the improvement of the vector control condition is satisfactory. A simplified control model of an induction motor similar to the model for a separately excited DC motor drive system is obtained.

  • PDF

Fault Diagnosis and Accommodation of Linear Stochastic Systems with Unknown Disturbances

  • Lee, Jong-Hyo;Joon Lyou
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.4 no.4
    • /
    • pp.270-276
    • /
    • 2002
  • An integrated robust fault diagnosis and fault accommodation strategy for a class of linear stochastic systems subjected to unknown disturbances is presented under the assumption that only a single fault may occur at a given time. The strategy is based on the fault isolation and estimation using a bank of robust two-stage Kalman filters and introduction of the additive compensation input for cancelling out the fault's effect on the system. Each filter is set up such that the residual is decoupled from unknown disturbances and fault with the influence vector designed in the filter. Simulation results for the simplified longitudinal flight control system with parameter uncertainties, process and sensor noises demonstrate the effectiveness of the present approach.

AN ANALYSIS OF TECHNICAL SECURITY CONTROL REQUIREMENTS FOR DIGITAL I&C SYSTEMS IN NUCLEAR POWER PLANTS

  • Song, Jae-Gu;Lee, Jung-Woon;Park, Gee-Yong;Kwon, Kee-Choon;Lee, Dong-Young;Lee, Cheol-Kwon
    • Nuclear Engineering and Technology
    • /
    • v.45 no.5
    • /
    • pp.637-652
    • /
    • 2013
  • Instrumentation and control systems in nuclear power plants have been digitalized for the purpose of maintenance and precise operation. This digitalization, however, brings out issues related to cyber security. In the most recent past, international standard organizations, regulatory institutes, and research institutes have performed a number of studies addressing these systems cyber security.. In order to provide information helpful to the system designers in their application of cyber security for the systems, this paper presents methods and considerations to define attack vectors in a target system, to review and select the requirements in the Regulatory Guide 5.71, and to integrate the results to identify applicable technical security control requirements. In this study, attack vectors are analyzed through the vulnerability analyses and penetration tests with a simplified safety system, and the elements of critical digital assets acting as attack vectors are identified. Among the security control requirements listed in Appendices B and C to Regulatory Guide 5.71, those that should be implemented into the systems are selected and classified in groups of technical security control requirements using the results of the attack vector analysis. For the attack vector elements of critical digital assets, all the technical security control requirements are evaluated to determine whether they are applicable and effective, and considerations in this evaluation are also discussed. The technical security control requirements in three important categories of access control, monitoring and logging, and encryption are derived and grouped according to the elements of attack vectors as results for the sample safety system.

Development of Hi-efficiency Direct Drive PMAC Controller for Screen Door (스크린도아용 고효율 직접구동 PMAC Driver 개발)

  • Park, Jae-Sam
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.17 no.7
    • /
    • pp.35-41
    • /
    • 2012
  • To control screen door installed in the subway platform, geared BLDC motors have been being used. However, because of the geared mechanisms, the control profile of the screen door in slow speed is very poor. Moreover, geared mechanism tends to leads system malfunctions and low efficiency. To overcome those problems, in this paper, the techniques of developing hi-efficiency direct drive gearless PMAC motor controller and application example to control the screen door of subway platforms are proposed. The developed system has advantages that; the energy efficiency has been increased by adopting gearless PMAC motor; the system break-down factor has been decreased due to the actuator mechanism has been simplified. In this paper, the screen door control system structure, PMAC motor drive circuit design, implementations of vector control algorithm, and test results are shown.

Development of a reduced-order distillation model and real-time tuning using the extended kalmen filter (증류공정 차수감소 모델의 개발 extended kalmen filter에 의한 실시간대에서의 조정)

  • 정재익;최상열;이광순
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10a
    • /
    • pp.466-470
    • /
    • 1988
  • A tunable reduced-order distillation model is proposed for real-time applications. To develop the model, a binary distillation column with MaCabe-Thiele assumptions was considered first and then the governing equations for the column were reduced to a simplified vector differential equations using the collocation method combined with cubic spline interpolation function. The final reduced-order model has four tuning parameters, relative volatilities and liquid holdups for rectifying and stripping sections, respectively. To assess the applicability of the developed model,the real-time adjustment of the model was tried by recursively updating the tuning parameters using the BKF algorithm. As a result, it was found that the reduced-model follows the simulated distillation process very closely as the parameters are improved.

  • PDF

Performance analysis of an explicit guidance system (직접식 관성유도시스템의 성능 분석)

  • 최재원;윤용중;이장규
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.419-424
    • /
    • 1991
  • In this paper, a fuel minimizing closed loop explicit inertial guidance algorithm for the orbit injection of a rocket is developed. In this formulation, the fuel burning rate and magnitude of thrust are assumed constant, and the motion of a rocket is assumed to be subject to the average inverse-square gravity, but with negligible atmospheric effects. The optimum thrust angle for obtaining the given velocity vector in the shortest time with minimizing fuel consumption is first determined, and then the additive thrust angle for targeting the final position vectors is determined by using Pontryagin's Maximum Principle. To establish the real time processing, many algorithms of the onboard guidance software are simplified. Simulations for the explicit guidance algorithm, for the 2nd-stage flight of the N-1 rocket, are carried out. The results show that the guidance algorithm works well in the presence of the maximum .+-.10 % initial velocity and altitude error. The effects of the guidance cycle time is also examined.

  • PDF

Realization of the Space Vector PWM Inverter Using a Quasi - Resonant DC Link (준 공진 DC 링크를 사용한 공간 벡터 PWM 인버터의 구현)

  • 한완옥;조성정;이정규;임승하;이성백
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.12
    • /
    • pp.137-144
    • /
    • 1994
  • In this paepr, we present a soft switching PWM inverter as reducing switching loss and stress at high power application. The PWM inverter is designed by space voltage about 2$\sqrt{3}$ times (15%) than conventional SPWM method. To reduce switching loss and stress. The DC link requires a capacitor, an inductor and two additional switches. Therefore proposed inverter performs trun PWM operation under the soft switching condition. As a result of soft switching we can reduce switching loss and ensure stability of switching devices. For approach to real time, control system is realized by 8 bit single-chip microprocessor. Therefore, we can construct system is with simplified volumn and structure by eliminating carrier wave and referrence wave generator of conventional SPWM method.

  • PDF