• Title/Summary/Keyword: Simple radiography

검색결과 122건 처리시간 0.024초

X선 단순촬영에 있어서 신장결석의 출현에 관한 검토 (A Study on the Phenomena of Renal Stone in Simple Radiography)

  • 유장수;송재관;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제12권1호
    • /
    • pp.25-29
    • /
    • 1989
  • This paper investigated on influence on the distinguishability of renal stone in the accordance with thickness of object, x-ray tube voltage and base density. In the relationship between object and renal stone shadow, object and tube voltage, the obtained results can be summarized as the following. 1. When thickness of object was thin, the distinguishability increased in base density $2.0{\sim}2.5$, but for adults was best shown in base density 1.5. 2. In the relationship between object and tube voltage, the distinguishability increased at lower tube voltages ($50{\sim}60\;kVp$), using grid. As mentioned above, it was thought that this method was very effective in describing the phenomena of renal stone in film density 1.5, tube voltages 60 kVp.

  • PDF

농도 보상용 셀로판지를 사용한 흥부촬영에 대한 검토 (A Study of Chest Radiography with Cellulose Paper)

  • 김영환;이창엽;김창남;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제10권1호
    • /
    • pp.25-29
    • /
    • 1987
  • To compensate density of abnormal lung field for density of normal lung field, used each cellulose paper calculated sensitometry and contrast. As apply clinic part to the result: We are able to compensate density of abnormal lung that is pleural effusion atelectasis, etc for normal lung. We believe this method is good one because the method is simple to change exposure and the material is cheap enough to be accessible to every one and easily buyable and we need not be afraid of loss of image quality.

  • PDF

개 전안방 안구사상충증 (Ocular Filariasis in Canine Anterior Chamber)

  • 김기홍;엄혜윤;나기정;양만표
    • 한국임상수의학회지
    • /
    • 제16권2호
    • /
    • pp.506-508
    • /
    • 1999
  • An one-year-old, female pointer dog with conjunctival hyperemia, corneal opaque and ocular pain in right eye was referred to Veterinary Medical Teaching Hospital, Chungbuk National University. In the ophthalmic examination the worm was observed in anterior chamber, The heart worm antigen test was positive. A modified Knott's test was negative. The values of complete blood count and serum chemistry (TP, BUN, creatinine, AST, ALT, ALP, albumin, globuline) showed normal ranges. Any abnormality was not detected in the heart using a thoracic radiography and cardiac sonography. Therefore, this dog was diagnosed as ocular filariasis. The worm was removed by surgical incision through a limbus of cornea. The closure of limbal incision was sutured in a simple interrupted suture pattern with 6-0 silk and the eye was reinflated with sterile saline solution. Antibiotics and dexamethasone ophthalmic solution were applied to right eye every 24 hours for 7 days. To prevent latent filariasis, ivermectin was also administered on day 14 of operation. The heart worm antigen test on day 60 was negative. The dog was successfully cured.

  • PDF

THIN-FILM-COATED DETECTORS FOR NEUTRON DETECTION

  • McGregor Douglas S.;Gersch Holly K.;Sanders Jeffrey D.;Klann Raymond T.;Lindsay John T.
    • Journal of Radiation Protection and Research
    • /
    • 제26권3호
    • /
    • pp.167-175
    • /
    • 2001
  • Semiconductor diode detectors coated with neutron reactive material are presently under investigation for various uses, such as remote sensing of thermal neutrons, fast neutron counting, and thermal neutron radiography. Theory indicates that single-coated devices can yield thermal neutron efficiencies from 4% to 11 %, which is supported by experimental evidence. Radiation endurance measurements indicate that the devices function well up to a limiting thermal neutron fluence of $10^{13}/cm^2$, beyond which noticeable degradation occurs. Thermal neutron contrast images of step wedges and simple phantoms, taken with dual in-line pixel devices, show promise for thermal neutron imaging detectors.

  • PDF

요추 추간판 탈출증에 대한 고찰 (A Review of Lumbar Herniated Intervertebral Disc)

  • 김형수;김은영;배성수
    • 대한물리의학회지
    • /
    • 제1권1호
    • /
    • pp.125-137
    • /
    • 2006
  • Purpose : The purpose of the study was to examine lumbar pain through literature reviews about herniated intervertebral disc (HIVD). Methods : Diagnosis was made by patient's history, physical examination, simple radiography, myelography, spinal computerized tomography, electromyography, somatosensory evoked potential, etc. Results : There are two treatment modalities, one is conservative and the other is operative. About 90% of patients with HIVD have been recovered only by conservative treatment and therapeutic exercise was the most effective one among these conservative treatments. Conclusion : We consider HIVD can be treated with therapeutic exercise which can correct muscular imbalance and facet joint problems and make the degenerative process of intervertebral disc slower.

  • PDF

Bisphosphonate related osteonecrosis of the jaws: report of two cases

  • Han, Jin-Woo
    • Imaging Science in Dentistry
    • /
    • 제41권3호
    • /
    • pp.129-134
    • /
    • 2011
  • Bisphosphonates are compounds used to treat osteoporosis and malignant bone metastasis. Despite the benefits related to the use of these medications, osteonecrosis of the jaws is a significant complication in a subset of patients receiving these drugs. This complication occurs either spontaneously or after a simple dento-alveolar surgery. Recently there were two patients who showed the features of bisphosphonate related osteonecrosis of the jaws (BRONJ) in Gangneung-Wonju National University Dental Hospital. The patients revealed the clinical and radiological features of classical osteomyelitis. This report presents two cases of BRONJ which were examined by plain radiography and computed tomography.

결함추출을 위한 강판튜브 엑스선 영상의 명암도 향상 (Contrast Enhancement for Defects Extraction from Seel-tube X-ray Images)

  • 황중원;황재호
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2007년도 하계종합학술대회 논문집
    • /
    • pp.361-362
    • /
    • 2007
  • We propose a contrast-controlled feature detection approach for steel radiograph image. X-ray images are low contrast, dark and high noise image. So, It is not simple to detect defects directly in automated radiography inspection system. Contrast enhancement, histogram equalization and median filter are the most frequently used techniques to enhance the X-ray images. In this paper, the adaptive control method based on contrast limited histogram equalization is compared with several histogram techniques. Through comparative analysis, CLAHE(contrast controlled adaptive histogram equalization) can enhance detection of defects better.

  • PDF

개에서 컴퓨터 단층 촬영 검사를 통한 추간판 탈출증 진단례 (Computed Tomographic Images of Vertebral Disc Herniation in Dogs)

  • 이기창;송경진;권정국;최민철
    • 한국임상수의학회지
    • /
    • 제20권4호
    • /
    • pp.519-522
    • /
    • 2003
  • An appearance of herniated intervertebral disc into thoracolumbar vertebral canal was evaluated in two patients using computed tomography (CT). Before CT scanning, plain radiography and myelography were performed in both cases. CT images were compared to those of myelography. Dogs were positioned in sternal recumbency under inhalation anesthesia and transverse slices with 2 mm thickness were obtained around thoracolumbar region. The transverse CT images were examined using both vertebral and spiral window mode. The most common findings on CT images were loss of vertebral canal epidural fat, bulging of vertebral canal disc margins, displacement of spinal cord and flatted vertebral canal. Whereas, narrowed intervertebral disc space and simple extradural pattern were the main findings on plain and contrast radiographs. CT imges showed the extent of the herniated disc lesion, type II intervertebral disc hernation, and the displacement of spinal cord in detail in both occations. It is considered that degree and precise localization of the intervertebral disc herniation and subtle lesion of spinal cord could be identified accurately using computed tomography.

Surgical management of an accessory canal in a maxillary premolar: a case report

  • Kim, Hee-Jin;Yu, Mi-Kyung;Lee, Kwang-Won;Min, Kyung-San
    • Restorative Dentistry and Endodontics
    • /
    • 제44권3호
    • /
    • pp.30.1-30.6
    • /
    • 2019
  • We report the surgical endodontic treatment of a maxillary first premolar with a lateral lesion that originated from an accessory canal. Although lesions originating from accessory canals frequently heal with simple conventional endodontic therapy, some lesions may need additional and different treatment. In the present case, conventional root canal retreatment led to incomplete healing with the need for further treatment (i.e., surgery). Surgical endodontic management with a fast-setting calcium silicate cement was performed on the accessory canal using a dental operating microscope. At the patient's 9-month recall visit, the lesion was resolved upon radiography.

단순 방사선 사진에서 견봉 및 상완골 대결절의 퇴행성 변화와 MRI상 회전근 개 파열 정도와의 연관성 (Correlation Between Degree of Torn Rotator Cuff in MRI and Degenerative Change of Acromion and Greater Tuberosity in Simple Radiography)

  • 최정윤;염재광;송민철
    • Clinics in Shoulder and Elbow
    • /
    • 제16권1호
    • /
    • pp.1-9
    • /
    • 2013
  • 목적: 단순 방사선 사진상에서 견봉 및 상완골 대결절의 퇴행성 변화의 정도와 회전근 개 파열의 크기 사이의 연관성을 알아보고자 하였다. 대상 및 방법: 견관절의 자기 공명 영상을 시행한 퇴행성 회전근 개 파열 실험군 234예와 회전근 개 파열이 없는 대조군 284예 등 총 518예를 대상으로 하였다. 견관절 방사선 단순 촬영에서 퇴행성 변화의 정도를 관절와-상완 관절의 퇴행성 변화를 제외한 견봉과 대결절에서 골극의 길이와 형태의 변형에 따라 분류하였고, 자기 공명 영상에서 회전근 개의 파열의 정도 및 전층 파열의 크기를 분류하였다. 회전근 개의 파열의 정도와 크기에 따른 견봉 및 상완골 대결절의 퇴행성 변화 정도와의 연관성에 대해 알아 보았다. 결과: 견관절 단순 방사선 사진에서 보이는 견봉 및 상완골 대결절의 퇴행성 변화에 따른 MRI상 회전근 개 파열의 정도는 유의한 차이를 보였고(p<0.001), 견봉 및 상완골 대결절의 단순 방사선상 퇴행성 변화가 증가할수록 회전근 개 파열의 크기가 커지는 경향이 있었으며(p<0.001), 부분층 파열 보다 전층 파열 가능성이 높은 것으로 나타났다(p<0.001). 또한 고령 및 여자에서 회전근 개의 파열이 더 심하다는 결과를 얻었다(p<0.001, p<0.001). 결론: 퇴행성 회전근 개 파열 환자에서 견관절의 단순 방사선 사진상 견봉 및 상완골 대결절의 퇴행성 변화가 심할수록 회전근 개 파열의 크기가 더 크고, 나이와 성별도 관련 인자 중 하나로 사료된다.