• 제목/요약/키워드: Simple radiography

검색결과 122건 처리시간 0.026초

단순 디지털 촬영과 저선량 CT의 폐기종 소견으로부터 폐쇄성 폐기능 장애 위험 비교 (Evaluation of Obstructive Pulmonary Function Impairment Risks in Pulmonary Emphysema Detected by Low-Dose CT: Compared with Simple Digital Radiography)

  • 이원정;이정오;최병순
    • Tuberculosis and Respiratory Diseases
    • /
    • 제71권1호
    • /
    • pp.37-45
    • /
    • 2011
  • Background: Pulmonary emphysema (PE) is major cause of obstructive pulmonary function impairment (OPFI), which is diagnosed by spirometry. PE by high resolution CT is known to be correlated with OPFI. Recently, low dose CT (LDCT) has been increasingly used for screening interstitial lung diseases including PE. The aim of this study was to evaluate OPFI risks of subjects with PE detected by LDCT compared with those detected by simple digital radiography (SDR). Methods: LDCT and spirometry were administered to 266 inorganic dust exposed retired workers, from May 30, 2007 to August 31, 2008. This study was approved by our institutional review board and informed consent was obtained. OPFI risk was defined as less than 0.7 of forced expiratory volume in one second (FEV1)/forced vital capacity (FVC), and relative risk (RR) of OPFI of PE was calculated by multiple logistic regression analysis. Results: Of the 266 subjects, PE was found in 28 subjects (10.5%) by LDCT and in 11 subjects (4.1%) by SDR; agreement was relatively low (kappa value=0.32, p<0.001). FEV1 and FEV1/FVC were significantly different between PE and no PE groups determined by either SDR or LDCT. The differences between groups were larger when the groups were divided by the findings of SDR. When PE was present in either LDCT or SDR assays, the RRs of OPFI were 2.34 and 8.65, respectively. Conclusion: LDCT showed significantly higher sensitivity than SDR for detecting PE, especially low grade PE, in which pulmonary function is not affected. As a result, the OPFI risks in the PE group by LDCT was lower than that in the PE group by SDR.

슬관절 활액 양 측정에서의 신체검사와 단순 방사선 검사, 초음파의 상관성 (Correlation of the Ultrasonography with the Physical Examinations and Simple Radiography in Measurement of Amount of Effusion of the Knee Joint)

  • 김정만;라기항;남호진;이정우
    • 대한정형외과 초음파학회지
    • /
    • 제3권1호
    • /
    • pp.15-20
    • /
    • 2010
  • 목적: 슬관절 초음파가 활액 양의 측정에서 신체 검사 및 단순 방사선 검사 소견과 비교하여 얼마나 유용한가를 알아 보고자 하였다. 대상 및 방법: 슬관절의 활액 증가가 의심되는 60예의 슬관절을 대상으로 하였다. 평균 나이는 61.3세, 여자 38명, 남자 22명 이였고, 비만하지 않은 사람이 24명, 비만한 사람이 36명 이였다. 신체 검사는 stroke test와 슬개골 부구 검사를 시행하였고, 방사선 소견은 측면 상에서 활액 양을 관찰하여 3단계로 분류하였으며, 초음파로 이를 확인하여 비교 분석하였다. 결과: stroke test는 39예에서 양성, 슬개골 부구 검사는 20예에서 양성을 보였고, 방사선 측면 검사는 1단계 47예, 2단계 7예, 3단계 3예로 관찰되었다. 초음파 검사는 평균 $7.67{\pm}2.90mm$의 활액 양이 관찰되었다. stroke test와 슬개골 부구 검사, 측면 방사선 검사 모두 초음파 검사와 양의 상관관계에 있었다(r=.405, .259, .714). 성별은 신체 검사에서는 상관관계의 큰 차이를 보이고 있지 않았고 측면 방사선 검사에서는 여성에서 강한 상관관계를 보였다(r=.789). 비만한 사람보다 비만하지 않은 사람이 세 검사 모두에서 더 강한 상관관계를 보였다. 신체 검사는 비만하지 않은 사람에서는 비교적 유용하였으나 비만한 사람에서는 부정확하였으며, 방사선 검사 상에서도 활액 정도 파악이 어려웠으나 초음파 상으로는 활액의 두께를 동적으로 측정하여 과학적 데이터를 얻을 수 있었다. 결론: 슬관절 활액 양의 측정에서는 초음파가 신체 검사나 방사선 소견에 비해 객관적 데이터를 얻을 수 있어 유용하였다.

  • PDF

고정 그리드를 사용한 디지털 방사선 영상에서 1차원 필터에 기초한 왜곡의 제거 (Artifact Reduction in Digital Radiography Images with the Stationary Grid Based on 1-Dimensional Filters)

  • 김동식
    • 대한전자공학회논문지SP
    • /
    • 제47권5호
    • /
    • pp.117-126
    • /
    • 2010
  • 산란선을 흡수하여 보다 선명한 x선 영상을 얻기 위하여 산란방지 그리드를 사용하여 투사영상을 얻는데, 이때 그리드로 인한 왜곡이 발생한다. 본 논문에서는 회전된 그리드를 사용하여 투사영상을 얻고 단순한 1차원 저역필터를 영상의 공간영역에서 각 축으로 별도로 적용하여 그리드 왜곡을 효율적으로 제거하는 방법을 제안하고 그 성능을 고찰해 보았다. 제안한 방법은 왜곡 주파수를 별도로 예측할 필요 없이, 회전된 그리드를 사용하여 획득한 영상에 단순한 1차원 필터를 주파수영역이 아닌 공간영역에서 적용하므로 매우 단순하여 쉽게 구현이 가능하며 빠른 계산 속도를 가지는 장점을 가지고 있으면서 그 성능은 주파수영역에서 2차원 필터를 적용한 경우와 유사하다.

Recurrent simple bone cyst of the mandibular condyle: a case report

  • Kim, Kyoung-A;Koh, Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • 제43권1호
    • /
    • pp.49-53
    • /
    • 2013
  • Cysts of the mandibular condyle are rare and can be difficult to diagnose and treat. Clinically, a simple bone cyst is asymptomatic and often discovered incidentally on routine radiographic examination. This report shows an atypical simple bone cyst occurring in the mandibular condyle showing recurrence after surgical curettage. Radiologically, this lesion involving the mandibular condyle should be distinguished from other similar lesions such as a chondroma, a central giant cell granuloma, and an aneurysmal bone cyst. Radiographic assessment was useful for forecasting the prognosis of a simple bone cyst. Possible reasons for the recurrence were discussed radiographically.

일반촬영에서 kVp와 mAs의 변화에 따른 농도와 환자 선량 비교 (A Comparison of Density and Patient Doses According to kVp and mAs Changes in General Radiography)

  • 강은보
    • 한국방사선학회논문지
    • /
    • 제13권7호
    • /
    • pp.987-994
    • /
    • 2019
  • 일반촬영의 저관전압 촬영에서 발생되는 저 에너지 X-선은 신체에 흡수가 많고 영상 품질 향상에는 도움을 주지 못한다. 본 연구에서는 일반 촬영에서 적정 농도를 유지하면서 환자의 피폭 선량을 줄이기 위해 농도에 따른 관전압 15%법칙과 농도에 비례하는 관전류량을 이용하여 면적 선량과 입사표면선량을 측정하여 환자의 피폭선량을 비교하였다. Hand, Knee, Abdomen, Skull 촬영에서 kVp를 115%까지 증가하면서 mAs를 50%까지 감소시키고, kVp를 85%까지 감소시키고 mAs를 200%까지 증가시키면서 면적선량과 입사표면선량을 측정하여 각각의 선량을 비교하였다. 그리고 각 영상의 5군데를 정하여 농도를 측정하고 Kruskal wallis H 검증을 하여 집단-간의 유의확률을 알아보았다. 농도를 일정하게하기 위해 관전압을 115%로 증가하고, 관전류를 50%로 감소시킨 조건에서 각 부위별 평균 면적선량과 입사표면선량을 측정한 결과 기준 선량을 100%로 할 때 각각 58.68%, 59.85%로 감소하고, 관전압을 85%로 감소하고 관전류를 200%로 증가시킨 조건에서 각각 147.28%, 159.9%로 증가하였다. 농도 변화를 비교한 결과 Hand, Knee, Abdomen, Skull 촬영 모두 유의확률 >0.05 나타나 농도 변화는 없는 것으로 나타났다. 해상력과 대조도에 영향을 주지 않는 범위에서 적정한 계산을 통해 관전압을 증가시키고 관전류를 낮게 해서 촬영하는 것이 적정농도를 유지하면서 환자의 피폭 선량을 줄이는 간단한 방법으로 사료된다.

복부 선자세 단순촬영시 화질과 피폭선량에 관한 연구 (A Study on the Image Quality and Patient Dose in Erect Simple Abdomen Radiography)

  • 김정민;임태랑;석전유치;앵정달야
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제21권1호
    • /
    • pp.29-34
    • /
    • 1998
  • The purpose of simple abdomen erect projection is to see the fluid level which indicates gastrointestinal ileus or free air due to perforation. we do not have to insist on low kVp technique in simple abdomen erect position as long as we can detect the fluid level and free air shadow. Therefore, the author tried to decrease patient dose by high kVp technique and to improve the image quality due to motion artifact by reduction of exposure time. [Methods] Experiment 1. * screen/film SRO1000/HRH * exposure factor : $140\;kvp{\pm}5\;kv$ with added filters, 200 mA, 0.01 sec * phantom : Acryles : 15.0 cm(equivalent to 17 cm body thickness) 17.5 cm(equivalent to 21 cm body thickness) 20.0 cm (equivalent to 25 cm body thickness) With the exposure factor for same film density($D=0.8{\pm}0.1$) and with the materials above, we tried to find out entrance skin dose and gonad dose for both male and female. Experiment 2. Burger's phantom radiography were checked to see whether there was any change of image quality according to the kVp and the added filters. Experiment 3. Using rotating meter(self made), we examined the motion artifact and the exposure time limitation. [Results and conculution] 1. Using high voltage technique of 140 kVp with added filter, Skin dose, testicle dose and ovary dose decrease to 89.3%, 47% and 71.4% respectively compare to 70 kVp technique, 2. No great changes of Burger's phantom image has detected as from 70 kVp to 140 kVp and the air hole size of Burger's phantom over 0.028 cc(Diameter 3 mm, hight 4 mm) can be distinghished. 3. 0.01 sec(1 pulse) exposure time is possible in the single phase full wave rectification that why we can quitely reduce the unsharness caused by patient's movement.

  • PDF

항과립구 항체 골수스캔을 이용한 다발성 골수종 병변의 평가: 단순골X-선점사 및 골스캔과의 비교 (Bone Marrow Scintigraphy with Antigranulocyte Antibody in Multiple Myeloma: Comparison with Simple Radiography and Bone Scintigraphy)

  • 김동환;이재태;백진호;정진태;현동우;천경아;이영학;손상균;송홍석;이규보
    • 대한핵의학회지
    • /
    • 제32권4호
    • /
    • pp.354-364
    • /
    • 1998
  • 목적: 단순골X-선검사와 골스캔은 다발성 골수종 병변의 조기검출에 많은 제한점을 가진다. 본 연구는 다발성 골수종에서 방사능 표지 항백혈구항체를 이용한 골수스캔의 유용성을 평가하기 위해 실시되었다. 대상 및 방법: 다발성 골수종 환자 22례의 경우 남녀비는 2.1:1이었고 중간연령은 57세였으며, Stage II는 3례, Stage III는 19례였다. 골수스캔은 $^{99m}Tc$으로 표지된 항백혈구 항체를 이용하여 전신상을 촬영하였고, 그 결과를 단순골X-선검사 및 골스캔과 부위별로 비교하였다. 결과: 단순골X-선검사는 14명(64%), 골스캔에서는 11명(50%)의 환자에서 병변을 검출한 반면, 골수스캔에서는 19명(86%)의 환자에서 국소결손병변을 검출하였다. 골수스캔은 Stage II에서는 33%의 환자(1/3)에서 병변을 검출하였고, Stage III에서는 90%의 환자(17/19)에서 병변을 검출하였다. 골수스캔에서 골수확장의 소견은 68% (15/22)에서 관찰되었다. 전체환자 22명에서 124개의 국소결손병변이 단순골X-선 검사, 골스캔, 골수스캔에서 검출되었는데, 단순골X-선검사는 58개 병변을, 골스캔은 40개 병변을 검출한 반면 골수스캔을 통해서는 92개 병변을 검출하였고, 단순골X-선검사나 골스캔에서는 검출하지 못한 국소결손병변을 51개나 더 검출할 수 있었으며, 이는 특히 새로운 흉요추 국소결손병변의 검출에 도움이 되었다. 결론: 골수스캔은 단순골X-선검사나 골스캔보다 높은 검출율을 보였고, 흉요추병변의 검출에 많은 도움을 줄 수 있는 것으로 생각된다. 또한 골수스캔은 진행한 병기에서 더 높은 검출율을 보여주어 골수스캔소견과 임상적 병기간에 상관성을 가지는 것으로 생각된다. 다발성 골수종에서의 골수스캔은 새로운 병변의 검출뿐만 아니라 병기정도의 평가에 도움이 될 것으로 판단된다.

  • PDF

인공 치아우식 발생 모델에서 디지털 방사선 공제술을 이용한 인접면 치아우식증의 진단 (Proximal caries detection using digital subtraction radiography in the artificial caries activity model)

  • 박정훈;최용석;황의환;이기자;최삼진;박영호;김경숙;진현석;홍경원;오범석;박헌국
    • Imaging Science in Dentistry
    • /
    • 제39권1호
    • /
    • pp.35-39
    • /
    • 2009
  • Purpose: The purpose of the experiment was to evaluating the diagnostic ability of dental caries detection using digital subtraction in the artificial caries activity model. Materials and Methods: Digital radiographies of five teeth with 8 proximal surfaces were obtained by CCD sensor (Kodak RVG 6100 using a size #2). The digital radiographic images and subtraction images from artificial proximal caries were examined and interpreted. In this study, we proposed novel caries detection method which could diagnose the dental proximal caries from single digital radiographic image. Results: In artificial caries activity model, the range of lesional depth was $572-1,374{\mu}m$ and the range of lesional area was $36.95-138.52mm^2$. The lesional depth and the area were significantly increased with demineralization time (p<0.001). Furthermore, the proximal caries detection using digital subtraction radiography showed high detection rate compared to the proximal caries examination using simple digital radiograph. Conclusion: The results demonstrated that the digital subtraction radiography from single radiographic image of artificial caries was highly efficient in the detection of dental caries compared to the data from simple digital radiograph.

  • PDF

X-선 단순 Series 촬영 시 피폭 선량 평가 (Assessment of Radiation Dose Due to X-Ray Simple Series Examinations)

  • 강은보;황인철;신운재
    • 한국방사선학회논문지
    • /
    • 제8권2호
    • /
    • pp.81-88
    • /
    • 2014
  • 진단영상의학에서 일반영상촬영의 경우 각각의 부위를 연속(series)촬영으로 검사하는 경우가 대부분이다. 그러나 환자선량권고량(DRL)의 경우 각 부위의 전후(AP)방향과 측면(lateral)자세의 촬영 측정값만이 설정되어있는 것이 현실이다. 병원에서는 환자의 연속 촬영에 의해 누적 선량이 발생되며, 이는 환자선량권고량(DRL)과 누적된 피폭선량을 비교할 수 없거나, 과소평가할 수 있다. 본 연구에서 각 부위별 연속촬영의 누적선량을 측정한 결과, 조사야에 포함된 경우 입사표면선량(ESD)을 유효선량으로 변환하면 공중의 선량한도(Individual dose)의 최대 38.06%에서 최소 0.23%까지 측정되었다. 그리고 조사야에 포함되지 않은 각 부위의 입사표면선량(ESD)을 유효선량(Effective dose)으로 변환한 경우 공중의 선량한도(Individual dose)의 최대 5%에서 최소 0.04%까지 측정되었다. 연구결과 각 부위별 연속촬영에서 입사표면선량(ESD)이 많이 증가하는 것을 알 수 있다. 따라서 병원에서는 환자선량권고량(DRL)을 구체적으로 설정할 필요가 있으며, 불필요한 검사를 줄이기 위해 환자 촬영 order의 세분화가 필요하다고 판단된다. 또한, 여러 부위의 검사에서는 정확한 조사야의 필요성이 강조된다.

정상인의 가로막(diaphragm) 높이와 만곡도 계측 (Measurement of Diaphragm in Normal Human)

  • 김함겸;마상철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제30권4호
    • /
    • pp.335-341
    • /
    • 2007
  • Simple chest radiography에서 정상인의 가로막(diaphragm)에 대한 계측치는 다음과 같다. 1. 전체 대상자에 대한 흉곽(internal diameter of thorax: ID)의 평균은 293.3 mm이었으며, 최소 221.0 mm, 최대 335.3 mm이었다. 2. 가로막의 높이는 오른 가로막이 높은 경우가 81.4%, 오른 가로막과 왼 가로막이 동일한 경우가 16.2%, 왼 가로막이 높은 경우가 2.4% 순으로 나타났다. 3. 오른 가로막이 높은 경우 오른 가로막의 평균 높이는 15.2 mm이었으며, 가장 낮은 경우는 2.0 mm, 가장 높은 경우는 41.7 mm이었다. 4. 왼 가로막이 높은 경우 왼 가로막의 평균 높이는 11.5 mm이었으며, 가장 낮은 경우는 4.7 mm, 가장 높은 경우는 30.4 mm이었다. 5. 가로막의 만곡도에서 오른 가로막의 평균 만곡은 22.9 mm이었고, 가장 작은 경우는 10.4 mm, 가장 큰 경우는 37.3 mm이었다. 6. 왼 가로막의 평균 만곡은 22.4 mm이었고, 가장 작은 경우는 11.3 mm, 가장 큰 경우는 42.2 mm이었다. 7. ID와 오른 가로막과 왼 가로막 만곡에 대한 관계에서 ID는 오른 가로막 만곡(r= .427, p<.001)과 왼 가로막 만곡(r= .425, p<.001)에서 모두 통계적으로 유의미한 정적 상관관계를 보였다. 8. 오른 가로막 만곡과 왼 가로막 만곡의 관계는(r= .403, p<.001) 통계적으로 유의미한 정적 상관관계를 보였다.

  • PDF