• Title/Summary/Keyword: Simple power analysis

Search Result 1,061, Processing Time 0.027 seconds

Formulation and Verification on Ritz Method for In-Cabinet Response Spectrum (캐비닛내부응답스펙트럼 산정을 위한 리츠방법의 정식화 및 단순예제를 통한 검증)

  • Kim, Ki Hyun;Hong, Kee-Jeung;Cho, Sung Gook;Park, Woong Ki
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.23 no.5
    • /
    • pp.279-288
    • /
    • 2019
  • Safety-related cabinets and their electrical parts, such as relays and switches in nuclear power plants, should maintain continuous functioning, as well as structural safety according to the nuclear regulatory guidelines. Generally, an electrical part is qualified if its functioning is maintained without abnormality during excitement by motion compatible with the test response spectrum, which is larger than its in-cabinet response spectrum (ICRS). ICRS can be determined by shake-table test or dynamic analysis. Since existing cabinets in use can hardly be stopped and moved, dynamic analysis is preferred over shake-table test in determining ICRS. The simple method, suggested by the Electric Power Research Institute (EPRI) to determine ICRS, yields conservative or non-conservative results from time to time. In order to determine that the ICRS is better than EPRI method in a simple way, Ritz method considering global and local plate behaviors was suggested by Gupta et al. In this paper, the Ritz method is modified in order to consider the rocking and frame behaviors simultaneously, and it is applied to a simple numerical example for verification. ICRS is determined by Ritz method and compared with the results by finite element method (FEM). Based on this numerical example, recommendations for using Ritz method are suggested.

Countermeasure Techniques Analysis for Power Analysis Attack (전력분석공격에 대한 대응기술 분석)

  • Kang, Young-Jin;Jo, Jung-Bok;Lee, HoonJae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.221-223
    • /
    • 2014
  • Power analysis attack on cryptographic hardware device aims to study the power consumption while performing operations using secrets keys. Power analysis is a form of side channel attack which allow an attacker to compute the key encryption from algorithm using Simple Power Analysis (SPA), Differential Power Analysis (DPA) or Correlation Power Analysis (CPA). The theoretical weaknesses in algorithms or leaked informations from physical implementation of a cryptosystem are usually used to break the system. This paper describes how power analysis work and we provide an overview of countermeasures against power analysis attacks.

  • PDF

On the Security of ID-Based Cryptosystem against Power Analysis Attacks (전력 분석 공격과 ID기반 암호 시스템의 안전성)

  • 양연형;박동진;이필중
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.14 no.4
    • /
    • pp.135-140
    • /
    • 2004
  • The ID-based cryptosystem and Power Analysis Attack are attracting many researchers and have been developed aggressively to date. Especially, DPA (Differential Power Analysis) attack has been considered to be the most powerful attack against low power devices, such as smart cards. However, these two leading topics are researched independently and have little hewn relations with each other. In this paper, we investigate the effect of power analysis attack against ID based cryptosystem. As a result, we insist that ID-based cryptosystem is secure against DPA and we only need to defend against SPA (Simple Power Analysis).

Energy-based Approach to Power Transfer System Analysis

  • Moon, Young-Hyun;Lee, Jong-Gi;Kwon, Yong-Jun
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.4
    • /
    • pp.227-235
    • /
    • 2004
  • This paper presents a new theoretical approach to energy-based power system analysis for multibus power transmission systems. On the basis of mechanical analogy, an exact energy integral expression is derived for lossy multi-bus systems through rigorous energy analysis. A simple rigid rod model of mechanical power transfer system is introduced to address the physical meanings of potential energy terms associated with transfer conductances as well as transfer susceptances. Finally, energy-based analysis has been proposed to show that the energy function has all information of the power system characteristics.

FPGA Implementation and Power Analysis Attack of Versatile Elliptic Curve Crypto-processor (가변 타원곡선 암호 프로세서의 FPGA 구현 및 전력분석 공격)

  • Jang, Su-Hyuk;Lee, Dong-Ho
    • Proceedings of the IEEK Conference
    • /
    • 2004.06b
    • /
    • pp.521-524
    • /
    • 2004
  • For implementation of Cryptographic algorithms, security against implementation attacks such as side-channel attacks as well as the speed and the size of the circuit is important. Power Analysis attacks are powerful techniques of side-channel attacks to exploit secret information of crypto-processors. In this thesis the FPGA implementation of versatile elliptic crypto-processor is described. Explain the analysis of power consumption of ALTERA FPGA(FLEX10KE) that is used in our hand made board. Conclusively this thesis presents clear proof that implementations of Elliptic Curve Crypto-systems are vulnerable to Differential Power Analysis attacks as well as Simple Power Analysis attacks.

  • PDF

Simple Structure LED-Driving Power Converter with High Power Factor (높은 역률을 가지는 단순 구조 LED 구동 전력컨버터)

  • Jeong, Gang-Youl
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.767-773
    • /
    • 2018
  • This paper proposes the simple structure LED-driving power converter with high power factor. As the proposed power converter combines the PFC boost converter and the conventional flyback converter into only one power conversion circuit, it simplifies the structure of LED-driving power converter. Thus the proposed converter is controlled using only one PWM controller IC, and it achieves high power factor, constant output voltage/current and cost-effectiveness. Therefore the proposed converter is suitable for the industry production and utilization of LED-light-system. In this paper, the operation analysis and design example of the proposed converter are explained, briefly. Also experimental results of the prototype that is implemented based on the designed circuit parameters are shown to validate operation characteristics of the proposed converter.

Settlement Evaluation of Caisson-Type Quay Wall Using PSI of Velocity During Earthquake (지진시 속도의 PSI를 활용한 케이슨식 안벽의 침하량 평가 )

  • Gichun Kang;Hyunjun Euo;Minje Baek;Hyunsu Yun;Jungwook Choi;Seong-Kyu Yun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.22 no.2
    • /
    • pp.71-83
    • /
    • 2023
  • It is very important to predict the amount of settlement in order to maintain the function of the coastal structure. Finite element analysis methods and real and model experiments are used as methods for this, but this has the disadvantage of requiring a lot of cost and time. Therefore, this study was conducted for the purpose of a simple formula proposal that can easily predict the amount of settlement of the caisson-type quay wall structure. In the research process, after calculating the PSI (Power Spectrum Intensity) of the velocity, the amount of settlement of the structure is calculated by substituting it into the simple formula of the existing gravity breakwater. By comparing and analyzing the amount of settlement of the structure obtained through numerical analysis, it was confirmed that the error between the amount of settlement of the existing simple formula and the amount of settlement of the numerical analysis was large, and it was confirmed that the background could not be considered in the case of the existing simple formula. Therefore, this study proposed a correction factor for the background of the quay wall structure, indicating a simple formula that can obtain the amount of settlement of the caisson-type quay wall structure. Compared to the numerical analysis settlement amount, it was judged that this simple formula had sufficient precision in calculating the caisson-type quay wall settlement amount. In addition, facilities vulnerable to earthquake resistance can be easily extracted in situations where time and cost are insufficient, and it is expected to be used as a screening technique.

comparative Study of Analytical Modal Properties of Instrumentation Cabinet of Nuclear Power Plant (모델링 방법의 차이에 따른 원전계측캐비넷의 동특성 해석 결과 비교분석)

  • 조양희
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.10a
    • /
    • pp.186-192
    • /
    • 1999
  • Safety-related equipments of nuclear power plant must be seismically qualified to demonstrate their ability to function as required during and/or after the earthquake, The seismic qualification is usually achieved through analysis and testing. Analysis method is preferably adopted for structurally simple equipments which are easy to be mathematically modeled. However even for relatively complex equipments analysis method is occasionally used for computing the input motion or supporting information for the component test followed. Electrical cabinet is a typical example for which analysis method is combinedly used with test to get modal properties of the enclosing cabinet structure. Usually the structural elements and doors of the cabinet are loosely interconnected with small-size bolts or spot welding. Therefore cabinet-type equipment usually has high and complex nonlinear properties which are not easily idealized by simple practical modeling techniques. in this paper with respect to a typical cabinet-type structure(instrumentation cabinet of nuclear power plant) a comparative study has been performed between three different state-of-the -art modeling techniques: lumped mass model frame model and FEM modal. Form the study results it has been found that modal properties of the cabinet-type structure in the elastic behavior range can be reasonably computed through any type of modeling techniques in the practice with slight modification of model properties to get better accuracy. However it needs additional modeling techniques to get reasonable results up to nonlinear range.

  • PDF

Improvement in Catalytic Activity of Ag Catalyst via Simple Mixing with Carbon

  • Choun, Myounghoon;Baek, Ji Yun;Eom, Taehyoung
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.4
    • /
    • pp.331-335
    • /
    • 2019
  • In this study we investigate catalytic activity and selectivity of mixture of Ag and ketjenblack according to their ratios by product analysis and electrochemical experiments, such as cyclic voltammetry, linear sweep voltammetry and chronoamperometry. We reveal that catalytic activity toward CO2 reduction to CO is improved by simple mixing Ag nanoparticle and ketjenblack because addition of ketjenblack suppresses aggregation of Ag nanoparticles and brings increase in electrochemical active surface area. However, excess amount of ketjenblack rather inhibit the CO2 reduction to CO. These observations provide clues to develop highly active Ag catalyst or electrode toward electrochemical reduction of CO2.

Wireless Sensor for Diagnostics of Electric Equipments (전력 설비 감시를 위한 무선 센서)

  • Choi, Yong-Sung;Kim, Hyung-Gon;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04c
    • /
    • pp.98-102
    • /
    • 2008
  • Methods and analysis of a simple wireless sensor concept for detecting and locating faults as well as for load monitoring are presented. The concept is based on distributed wireless sensors that are attached to the incoming and outgoing power lines of secondary substations. A sensor measures only phase current characteristics of the wire it is attached to, is not synchronized to other sensors and does not need configuration of triggering levels. The main novelty of the concept is in detecting and locating faults by combining power distribution network characteristics on system level with low power sampling methods for individual sensors. This concept enables the sensor design to be simple, energy efficient and thus applicable in new installations and for retrofit purposes in both overhead and underground electrical distribution systems.

  • PDF