• 제목/요약/키워드: Simple Source

검색결과 1,343건 처리시간 0.026초

Development and validation of an LC-MS/MS method for the simultaneous analysis of 26 anti-diabetic drugs in adulterated dietary supplements and its application to a forensic sample

  • Kim, Nam Sook;Yoo, Geum Joo;Kim, Kyu Yeon;Lee, Ji Hyun;Park, Sung-Kwan;Baek, Sun Young;Kang, Hoil
    • 분석과학
    • /
    • 제32권2호
    • /
    • pp.35-47
    • /
    • 2019
  • In this study, high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was employed to detect 26 antidiabetic compounds in adulterated dietary supplements using a simple, selective method. The work presented herein may help prevent incidents related to food adulteration and restrict the illegal food market. The best separation was obtained on a Shiseido Capcell Pak(R) C18 MG-II ($2.0mm{\times}100mm$, $3{\mu}m$), which improved the peak shape and MS detection sensitivity of the target compounds. A gradient elution system composed of 0.1 % (v/v) formic acid in distilled water and methanol at a flow rate of 0.3 mL/min for 18 min was utilized. A triple quadrupole mass spectrometer with an electrospray ionization source operated in the positive or negative mode was employed as the detector. The developed method was validated as follows: specificity was confirmed in the multiple reaction monitoring mode using the precursor and product ion pairs. For solid samples, LOD ranged from 0.16 to 20.00 ng/mL and LOQ ranged from 0.50 to 60.00 ng/mL, and for liquid samples, LOD ranged from 0.16 to 20.00 ng/mL and LOQ ranged from 0.50 to 60.00 ng/mL. Satisfactory linearity was obtained from calibration curves, with $R^2$ > 0.99. Both intra and inter-day precision were less than 13.19 %. Accuracies ranged from 80.69 to 118.81 % (intra/inter-day), with a stability of less than 14.88 %. Mean recovery was found to be 80.6-119.0 % and less than 13.4 % RSD. Using the validated method, glibenclamide and pioglitazone were simultaneously determined in one capsule at concentrations of 1.52 and 0.53 mg (per capsule), respectively.

경안천 서하보 수저퇴적물 준설이 경기도 광주시 수질오염총량관리에 있어 추가적인 부하량 삭감수단으로써 타당한가? (Dredging Bottom Sediments of Seoha Weir at the Downstream of Kyongan Stream can be Used as a Feasible Pollutant Load Reduction Option in the Total Pollutant Load Management System of Kwangju City?)

  • 유승훈;이범연;이강현;박신정;이창희
    • 한국물환경학회지
    • /
    • 제27권1호
    • /
    • pp.19-29
    • /
    • 2011
  • In order to assess the influences of bottom sediment on water quality, following measurement were made. (1) Estimations of pollutant loads from the bottom sediment based on mass balance concept, (2) measurements of pollutant concentrations in the sediment to assess the pollution level and influence potential, (3) in situ and laboratory measurements of Sediment Oxygen Demants (SOD) and pollutant load (sediment release) from bottom sediment. Analyses of inflow and outflow loadings using simple mass balance show that there are some variations found according to the pollutants. However, there is no consistent evidence that the sediment can be a source of pollutants. Pollutant concentrations in the sediment range 16~724.8 mg/kg (COD), 1.68 ~12.64 mg/kg (T-P), 5.6~76.8 mg/kg (T-N), 0.32~21.6 mg/kg ($NH_3$-N), 0.092~0.544 mg/kg ($NO_2$-N), 4.8~18.4 mg/kg ($NO_3$-N), and 1.59~11.23 mg/kg ($PO_4$-P). Measured SOD ranges $0.190{\sim}0.802g{\cdot}m^{-2}{\cdot}d^{-1}$ and measured release rate ranges $-1618.42{\sim}10mg/m^2{\cdot}d$(COD), $-12{\sim}16mg/m^2{\cdot}d$(T-P), $-197.37{\sim}140mg/m^2{\cdot}d$(T-N), $0.4{\sim}74.32mg/m^2{\cdot}d$($NH_3$-N), $-2.04{\sim}0.8mg/m^2{\cdot}d$ ($NO_2$-N), $-70{\sim}40mg/m^2{\cdot}d$ ($NO_3$-N), and $-26.11{\sim}28.55mg/m^2{\cdot}d$($PO_4$-P). All study results indicate that bottom sediments in the Seoha weir show only limited effects on the water quality. It implies that sediment dredging is not an effective option or management measure to reduce pollutant loading.

수변도시의 물순환 목표 산정 방안 연구 (Study on Estimation Method of Water Cycle Goal in Waterfront City)

  • 김재문;백종석;신현석;박경재
    • 한국산학기술학회논문지
    • /
    • 제21권12호
    • /
    • pp.475-487
    • /
    • 2020
  • 국토교통부와 환경부의 물관리 일원화로 인해 국민들의 물관리 및 물환경 보존에 대한 관심이 고조되고 있다. 기존의 단순 유출 및 비점오염원 관리를 위한 장치형 시설 및 함양지의 확대에서 유역 전반의 건전한 물순환 체계 구축으로의 물관리 패러다임이 변화하고 있다. 이에 힘입어 유역 전반의 물관리에 대한 필요성은 지자체별 조례를 통해 기준을 확립하고 있다. 하지만 건전한 물순환을 위한 도시별 물관리 기준이 통일되지 않아 도시별 목표가 각기 다르고 대도시를 제외하고는 정량적 목표가 전무한 현실이다. 본 연구에서는 지자체별 물순환과 관련한 연구 및 조례를 정리하여 수변 지역의 도시를 대상으로 개발 이후에도 탄력적인 물관리가 가능한 물순환 목표를 설정하고, 이를 달성할 수 있는 정량적인 방안을 강우의 저장과 침투를 통해 제시하였다. 대상지의 전체 강우 분석을 통해 합리적인 수준의 물순환 목표를 설정하였고, 저영향개발 기법을 통해 최초 강우의 저장과 저장량을 초과한 강우에 대한 유역 전반의 침투를 통해 물관리를 계획하였다. 연구결과, 계획한 수변도시의 물순환 목표는 전체 강우의 52 %, 백분위수 비교를 통한 80 percentile의 강우 17 mm/day를 처리할 수 있는 것으로 확인되었다. 이러한 산정절차결과에 정량적으로 질을 높이기 위해서 추후에 저영향개발 요소의 안전성이나 적정제원선정 등과 같은 여러 변수들을 고려한다면 물순환 목표 산정에 신뢰도가 더 높을 것으로 사료된다.

블록체인 자동화도구 개발과 전자투표 적용사례 (A Blockchain Network Construction Tool and its Electronic Voting Application Case)

  • ;;김옥기;이경희;조완섭
    • 한국빅데이터학회지
    • /
    • 제6권2호
    • /
    • pp.151-159
    • /
    • 2021
  • 블록체인 네트워크를 구축하려면 다양한 유형의 IT 지식과 기술이 필요할 뿐 아니라 장시간의 번거로운 과정이 필요하다. 이러한 한계를 극복하기 위해 MS사와 같은 글로벌 IT 기업들은 클라우드 기반 블록체인 서비스를 제공하고 있다. 본 논문에서는 블록체인 개발자, 블록체인 운영자와 기업이 자신의 인프라에 블록체인을 보다 편안하게 배치할 수 있도록 하는 블록체인 기반 구축 및 관리 도구를 제안한다. 이 도구는 대표적인 프라이빗 블록체인 플랫폼 중 하나인 Hyperledger Fabric과 네트워크 전체 배포를 지원하는 오픈소스 IT 자동화 엔진인 Ansible을 사용하여 구현한다. 복잡하고 반복적인 텍스트 명령 대신 사용자가 블록체인 네트워크를 원활하게 설정, 배포 및 상호 작용할 수 있는 사용자 친화적인 웹 대시보드 인터페이스를 제공한다. 이 제안된 솔루션을 통해 블록체인 개발자, 운영자 및 블록체인 연구자는 블록체인 인프라를 보다 쉽게 구축하여 시간과 비용을 절약할 수 있다. 제안된 도구의 유용성과 편의성을 검증하기 위해 전자투표를 수행하는 블록체인 네트워크를 구축하여 테스트하였다. 10개 이상의 설정 파일을 작성하고 수백 줄에 걸쳐 명령을 실행하는 블록체인 네트워크 구성을 그래픽 사용자 인터페이스에서 간단한 입력 및 클릭 조작으로 대체할 수 있어 사용자의 편의성과 구축시간을 절약을 확인할 수 있었다. 제안된 블록체인 도구는 앞으로 식품안전 공급망 구축 등 다양한 분야에서 신뢰 데이터 인프라 구축에 활용될 예정이다.

암모니아 활용 고체산화물 연료전지 발전시스템의 엑서지 분석 (Exergetic Analysis of Ammonia-fueled Solid Oxide Fuel Cell Systems for Power Generation)

  • 쿠엔;배용균;안국영;이선엽;김영상
    • 한국가스학회지
    • /
    • 제27권3호
    • /
    • pp.27-34
    • /
    • 2023
  • 고체 산화물 연료전지의 연료로 암모니아를 사용하는 것은 고효율, 환경 친화성, 보관 및 운송의 용이성으로 인해 주목받고 있다. 암모니아 활용 SOFC 시스템의 효율을 더욱 높이려면 시스템의 비효율적인 구성 요소를 이해해야 하며 이를 위해 엑서지 분석을 수행하였다.본 연구에서는 단순 연료전지 시스템(FC), 연료극 재순환 시스템(RC-FC) 및 수분 제거 재순환 시스템(RC-WR-FC)의 세 가지 시스템에 대해 엑서지 분석을 수행하였다. FC, RC-FC 및 RC-WR-FC의 엑서지 효율은 각각 48.7%, 51.6% 및 58.4%이었으며, 세 시스템 모두에서 SOFC 스택은 엑서지 파괴의 주요 원인이었다. 또한 버너, 공기 열 교환기 및 냉각기/응축기와 같이 낮은 효율을 가진 부품들을 재구성한다면 효율을 높일 수 있다.

혈중 산소 포화도의 정확한 공간 매핑을 위한 다중 파장 LED 단일소자를 활용한 이미징 시스템 설계 (A Simple Design of an Imaging System for Accurate Spatial Mapping of Blood Oxygen Saturation Using a Single Element of Multi-wavelength LED)

  • 김준환;유기연;송예은;유찬영;장윤채;무하마드 리아즈;케이 뜨웨 툰;아메드 알리;최승호
    • 대한의용생체공학회:의공학회지
    • /
    • 제44권6호
    • /
    • pp.450-464
    • /
    • 2023
  • Pulse oximetry, a non-invasive technique for evaluating blood oxygen saturation, conventionally depends on isolated measurements, rendering it vulnerable to factors like illumination profile, spatial blood flow fluctuations, and skin pigmentation. Previous efforts to address these issues through imaging systems often employed red and near-infrared illuminations with distinct profiles, leading to inconsistent ratios of transmitted light and the potential for errors in calculating spatial oxygen saturation distributions. While an integrating sphere was recently utilized as an illumination source to achieve uniform red and near-infrared illumination profiles on the sample surface, its bulkiness presented practical challenges. In this work, we have enhanced the pulse oximetry imaging system by transitioning illumination from an integrating sphere to a multi-wavelength LED configuration. This adjustment ensures simultaneous emission of red and near-infrared light from the same position, creating a homogeneous illumination profile on the sample surface. This approach guarantees consistent patterns of red and near-infrared illuminations that are spatially uniform. The sustained ratio between transmitted red and near-infrared light across space enables precise calculation of the spatial distribution of oxygen saturation, making our pulse oximetry imaging system more compact and portable without compromising accuracy. Our work significantly contributes to obtaining spatial information on blood oxygen saturation, providing valuable insights into tissue oxygenation in peripheral regions.

천해역 취득 데이터를 이용한 수중음향통신 수신기 성능분석 (Performance Analysis of Receiver for Underwater Acoustic Communications Using Acquisition Data in Shallow Water)

  • 김승근;김시문;윤창호;임용곤
    • 한국음향학회지
    • /
    • 제29권5호
    • /
    • pp.303-313
    • /
    • 2010
  • 본 논문에서는 25 kHz의 반송파와 5 kHz의 심볼율을 갖는 QPSK (Quadrature Phase Shift Keying) 통신시스템에서 수신된 신호를 100 kHz로 샘플링하여 전송데이터를 복원하는 수중통신용 수신기의 구조에 대하여 논한다. 또한, 천해역에서 제작한 센서를 이용하여 취득한 데이터를 2:1의 비율로 간축한 후 설계한 수신기의 입력으로 하여, 결합채널등화기 출력신호의 BER (Bit Error Rate) 을 최소화하는 결합채널등화기의 FF (Feed-Forward) 및 FB (Feed-Back) 필터 탭 수 및 RLS (Recursive Least-Square) 알고리듬의 망각인자 등의 설계 파라미터를 도출하였다. 취득 신호의 전송거리는 각각 1.4 km, 2.9 km, 4.7 km이다. 분석결과 BER을 최소화하기 위한 결합채널등화기의 FF 와 FB 탭 수는 전송거리에 따라 상이하나 망각인자는 0.997에서 최적 또는 최적에 가까운 성능을 보이는 것을 확인하였다. 그러므로, 수중음향통신 수신기 설계시 망각인자, ${\lambda}$,는 0.997로 고정하고, 전송거리에 따라 최적의 성능을 갖는 결합채널등화기의 FF 필터 탭 수와 FB 필터 탭수를 가변적으로 변경할 수 있는 구조를 갖는 수신기를 설계하는 것이 바람직하다는 결론을 얻을 수 있었다. 또한, 수신기 성능 분석을 통하여 본 논문에서 고려하는 시스템에서는 16탭 길이를 갖는 간단한 형태의 필터를 161탭 길이를 갖는 정합필터 대신에 수신기의 저역통과필터로 사용하더라도 성능의 열화가 적음을 확인하였다.

터보차저의 공기맥동음 평가를 위한 측정 및 판별법 (Measurement and Discrimination Method for the Evaluation of Aero-Pulsation Noise Generated by the Turbocharger System)

  • 김재헌;이종규
    • 한국음향학회지
    • /
    • 제26권7호
    • /
    • pp.361-365
    • /
    • 2007
  • 터보차저가 장착된 승용디젤엔진차량의 주요 소음원 중 하나로 터보차저 회전체의 기하학적 불균형에 기인한 공기 맥동음을 들 수 있다. 이 소음의 주요 발생부는 일반적으로 터보차저의 컴프레서휠로서 소음기와 같은 후처리 장치에 의해 저감될 수 있지만, 제조비용을 증가시키는 요인이 될 수 있다. 보다 효과적인 방법은 전반적인 기하학적 대칭성을 개선하거나 문제가 될 수 있는 단품을 분별해냄으로써 단품 품질을 관리하는 것이다. 제조상의 문제나 기타 여러 관점에서 볼 때, 단품에 대한품질관리가 보다 효과적이고 적합하다고 할 수 있다. 이를 위해서는, 생산 라인상에서 공기맥동음의 수준을 평가할 수 있는 적절한 판별방법이 필요하다. 본 논문에서는 공기맥동음의 수준을 정확히 측정할수 있는 방법을 소개하고 그 판별기준도 제시하고자 한다. 또한 리그 측정시스템의 신뢰성 평가과 함께, 리그측정결과와 차량측정결과 간의 상관관계도 분석하였다. 25개 샘플에 대한 측정 재현성 검증을 위해 게이지 R&R 기법을 활용하였다. 이와같은 측정 및 분석 결과로부터, 공기맥동음 관점에서 단품의 우열을 판별할수 있는 표준관리값을 제시할 수 있었다.

Reduction of Radiation Dose to Eye Lens in Cerebral 3D Rotational Angiography Using Head Off-Centering by Table Height Adjustment: A Prospective Study

  • Jae-Chan Ryu;Jong-Tae Yoon;Byung Jun Kim;Mi Hyeon Kim;Eun Ji Moon;Pae Sun Suh;Yun Hwa Roh;Hye Hyeon Moon;Boseong Kwon;Deok Hee Lee;Yunsun Song
    • Korean Journal of Radiology
    • /
    • 제24권7호
    • /
    • pp.681-689
    • /
    • 2023
  • Objective: Three-dimensional rotational angiography (3D-RA) is increasingly used for the evaluation of intracranial aneurysms (IAs); however, radiation exposure to the lens is a concern. We investigated the effect of head off-centering by adjusting table height on the lens dose during 3D-RA and its feasibility in patient examination. Materials and Methods: The effect of head off-centering during 3D-RA on the lens radiation dose at various table heights was investigated using a RANDO head phantom (Alderson Research Labs). We prospectively enrolled 20 patients (58.0 ± 9.4 years) with IAs who were scheduled to undergo bilateral 3D-RA. In all patients' 3D-RA, the lens dose-reduction protocol involving elevation of the examination table was applied to one internal carotid artery, and the conventional protocol was applied to the other. The lens dose was measured using photoluminescent glass dosimeters (GD-352M, AGC Techno Glass Co., LTD), and radiation dose metrics were compared between the two protocols. Image quality was quantitatively analyzed using source images for image noise, signal-to-noise ratio, and contrast-to-noise ratio. Additionally, three reviewers qualitatively assessed the image quality using a five-point Likert scale. Results: The phantom study showed that the lens dose was reduced by an average of 38% per 1 cm increase in table height. In the patient study, the dose-reduction protocol (elevating the table height by an average of 2.3 cm) led to an 83% reduction in the median dose from 4.65 mGy to 0.79 mGy (P < 0.001). There were no significant differences between dose-reduction and conventional protocols in the kerma area product (7.34 vs. 7.40 Gy·cm2, P = 0.892), air kerma (75.7 vs. 75.1 mGy, P = 0.872), and image quality. Conclusion: The lens radiation dose was significantly affected by table height adjustment during 3D-RA. Intentional head off-centering by elevation of the table is a simple and effective way to reduce the lens dose in clinical practice.

이론적 모델을 이용한 4DCT에서의 Motion Artifact 분석 (A Theoretical Model for the Analysis of Residual Motion Artifacts in 4D CT Scans)

  • 김태호;윤제웅;강성희;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제23권3호
    • /
    • pp.145-153
    • /
    • 2012
  • 본 연구에서는 호흡에 의한 표적의 움직임 모사가 가능한 팬톰을 이용, 나선형 4DCT 영상에서 발생되는 위상 내 모션 아티팩트(residual motion artifact)의 경향을 분석했으며, 그 특성 및 원인 분석을 위한 이론적 모델을 제시하였다. 표적의 움직임은 SI 방향의 1차원 사인파형을 적용하였으며, 주기는 4s로 고정, 진폭은 10, 20, 30 mm로 변화를 주었다. 표적의 움직임과 동조를 이루는 호흡신호를 얻은 후 이를 기반으로 최대흡기(Inhale peak, 0%)로부터 10% 위상간격(phase bin)으로 재분류하여 총 10개의 4DCT 영상을 재구성하였다. 각각의 진폭(10, 20, 30 mm)별로 획득된 총 30 사례의 영상은 RTP 시스템(CorePLAN, SC&J)에서 분석을 수행하였으며, 경계설정 시 오류를 줄이기 위해 contour window를 고정 값으로 설정한 후 SI 방향의 표적 지름변화를 측정하여 왜곡 정도를 평가 하였다. 각 위상 별 표적의 지름 변화를 측정한 결과 일정한 변화 경향을 확인할 수 있었다. 3 사례(10, 20, 30 mm) 모두 50% 위상(phase) 영상에서 비교적 작은 지름 변화가 관찰 되었는데 10 mm 진폭에서는 정지 영상 대비 변화가 없었고, 20 mm 진폭에서는 0.1 cm (5%)의 변화, 30 mm 진폭에서는 0.1 cm (5%) 변화를 확인할 수 있었다. 반면 30% 위상(phase) 또는 80% 위상 영상에서는 다른 위상 영상에 비해 표적 지름의 변화가 비교적 크게 나타남을 확인할 수 있었다. 10 mm 진폭에서는 정지 영상대비 최대 0.2 cm (10%) 지름 변화가 나타났고 20 mm 진폭에서는 최대 0.7 cm (35%)의 변화, 30 mm 진폭에서는 최대 0.9 cm (45%)의 지름 변화가 나타났다. 이상의 실측결과를 이론모델의 시뮬레이션 결과와 비교해 봤을 때 변화의 양적인 측면에서는 다소 차이가 발생되었지만 변화의 경향성을 확인하는 측면에서는 의미 있는 결과를 얻을 수 있었다. 본 연구의 결과를 통해 규칙적인 1차원 표적 움직임(sine motion)이 적용된 나선형 4DCT 영상에서도 위상 내 움직임에 의한 표적 지름변화가 발생될 수 있음을 확인했고 각 위상(phase)에서의 영상왜곡 정도가 위상 내 움직임의 속도에 비례함을 증명할 수 있었다. 또한 이상의 실측 결과를 이론모델에 적용하여 분석함으로써 위상 내 모션 아티팩트(residual motion artifact)의 발생원인 및 경향성 분석에 직관적 이해를 도울 수 있었고 이론모델에 기초한 분석 프로그램을 개발하여 특정 CT 파라미터(parameter) 상에서 영상왜곡을 줄이기 위한 최적의 위상(phase) 선택에 도움을 줄 수 있었다.