• 제목/요약/키워드: Similitude

검색결과 147건 처리시간 0.027초

모델재를 이용한 회전단조 공정의 시뮬레이션 (Simulation of Rotary Forging Process by Model Material Technique)

  • 윤덕재;최석우;나경환;김종호
    • 소성∙가공
    • /
    • 제4권1호
    • /
    • pp.9-16
    • /
    • 1995
  • Model material technique, which requires only the small space of experimental set-up and low cost for experiment, is used to estimate the deformed profile and the forging load in rotary forging. The materials and working conditions are determined to satisfy the similitude conditions between the model test and the prototype test. The model material of the so-called plasticine and the mild steel are chosen as specimens, and they represent almost the same value of strain gardening exponent in the stress-strain relationship. Lubricant in the model test is also carefully selected so that it gives the same frictional conditions at the tool-specimen interface. Experiments for two kinds of specimens are carried out in each testing equipment at room temperatue. From the experiments the deformed dimensions and the forging loads are measured and compared with each other by using the simulation coefficients. It is shown that there are good agreements between the model test and the prototype test. Finally, for verifying the availability of the model material technique this mathod is applied to forging of bevel gear product. the good result is obained which can demonstrate that the model material technique is very efficent for estimating or developing a new process.

  • PDF

1/3축소 3층 삼환까뮤 P.C 모델의 진동대 실험 (Shaking Table Test of 1/3-Scale 3-Story Sam-Hwan Camus Precast Concrete Model)

  • 이한선
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1992년도 가을 학술발표회 논문집
    • /
    • pp.140-154
    • /
    • 1992
  • The objective of the research stated here was aimed at providing the information needed to establish the Korean Seismic Design Code Recommendations and Guides for precast concrete (P.C) large panel apartment buildings. This was accomplished by investigation and analysis of the response of P.C large panel structures subjected to shaking table excitation simulating earthquake ground motion. one of the test specimens used was 1/3-scaled 3-story box P.C model provided by Sam-Hwan Camus Corporation. The 4m $\times$4m shaking table was used to simulate the earthquake ground motion. the employed input accelerogram was the one recorded as Taft N21E component and the peak ground acceleration(PGA) was scaled depending on the desired level of seismic severity and the time according to dynamic similitude rule. Based on results obtained from shaking table test of this P.C model, the following conclusions were drawn . (1) As far as test specimen is concerned, the seismic safety factors turns out to be 7~8. (2)P.C model has damping ratio of about8% which is twice larger than in-situ R.C. structure. And (3)this model has global displacement ductility ratio of 2~3 through the energy dissipation by opening and sliding of joints.

  • PDF

자기회로의 위상학적 상사성을 이용한 전류제한기 구조에 관한 연구 (The Research for a Structure of Current Limiter using a Phasic Similitude of Magnetic Circuit)

  • 지근양;장봉환;이수원;민경일;문영현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.344_346
    • /
    • 2009
  • 본 논문에서는 전력계통에서 고장발생시 자속의 변화를 통한 magnetic switching을 이용한 전류제한기를 제안하였다. 구조는 자속이 흐를 수 있는 철심과 회로에 연결되어 있는 1차권선, 철심과 1차권선 사이에 위차한 1차권선과 반대방향으로 감겨져 있는 2차권선 및 2차권선 하부에 이동이 가능한 동판의 2차권선 secondary로 구성되어 있다. 정상상태에서는 철심내에 1차권선과 2차권선에 의해 발생된 자속이 서로 상쇄되어 두 권선에 유기되는 전압은 0이지만 고장이 발생하여 2차 권선의 스위치를 open하고 2차권선 secondary를 철심밖으로 쳐 내면 그동안 상쇄되었던 자속이 철심을 통하여 흐르게 되고 이에 따라 1차권선에 유기된 전압은 회로의 전류를 제한하게 되므로 차단기를 용이하게 동작시킬 수 있는 구조이다. 실험을 통하여 전류제한기 동작 전 후의 전류제한 효과를 분석하였으며 이를 통해 본 논문에서 제안하는 시스템은 차단기에 가해지는 아크충격을 완화하여 설비의 수명을 연장하고 적은 용량의 차단기 사용이 가능하므로 설비투자예산 절감 및 모든 차단기 사용분야에 활용될 수 있는 장점을 가지고 있음을 확인하였다.

  • PDF

일체형 하천호안블럭의 개발 및 모형실험 적용 (Invention and Hydraulic Model Test of Combined Block System in River Bank Protection)

  • 장석환;이창해;박상우
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2008년도 학술발표회 논문집
    • /
    • pp.449-453
    • /
    • 2008
  • This research focused on analyzing and comparing between the results of hydraulic physical modeling and the results of numerical modeling of Grass Concrete which is newly developed in-situ block system. The physical model was built as a scale of 1:50 by Froude similitude measuring the water levels and the water velocities for before and after vegetation and the effects were analyzed after reviewing the results. In consequence, the water velocities were observed to decrease meanly 19.1%, and the water depth were determined to increase meanly 27.8% in case of the of design flood, $Q=200m^3/sec$. Moreover, the velocities were produced reduction effects of 27.2%, and the water levels were derived from addition effects of the highest 31.3% in case of the probability maximum flood(PMF), $Q=600m^3/sec$. To verifying the hydraulic physical modeling, the numerical modeling was conducted for a close examination of before and after vegetation. HEC-RAS model was for 1 dimensional numerical analysis and RMA-2 was for 2 dimensional numerical analysis. The results of the numerical simulation, under the condition of roughness coefficient calibration, shows similar results of the physical modeling. These satisfactory results show that the accomplished results of hydraulic modeling and the predicted results of numerical modeling corresponded reasonably each others.

  • PDF

1/3축소 3층 습식접합 프리캐스트 콘크리트 대형판 입체모델의 진동대 실험 (Shaking Table Tests of 1/3-Scale 3-Story Wet-Jointed Precast Concrete Large Panel Box Model)

  • 이한선
    • 콘크리트학회지
    • /
    • 제5권1호
    • /
    • pp.115-127
    • /
    • 1993
  • 본 연구의 목적은 프리캐스트 콘크리트(P.C) 대형판 아파트 구조물에 대한 우리나라 내진설계기준안 및 지침을 수립하기 위해 필요로 하는 정보를 취득하는데 있다. 이것은 실제 지진과 유사한 진동을 발생시키는 진동대를 사용하여 P.C대형판 구조물의 거동을 분석관찰함으로써 달성되었다. 여기에 사용된 시험체중의 하나는 습식접합 1/3 축소 3층 입체 P.C모델이었다. 지진파를 일으키기 위해 4mx4m 크기의 진동대가 사용되었다. 또한 선택한 입력지진가속도파는 Taft N21E 성분기록지진파로서 최대지진가속도(PGA)는 원하는 지진세기수준에 따라 조정되었고 시간축으로는 동적상사성법칙에 따라 축소되었다. 이 P.C모델의 진동대 실험을 통해 얻은 결과를 근거로 하여, 근거로 하여 다음과 같은 결론을 도출하였다. (1)이 시험체에 관한한, 지진안전계수는 7-8정도로 나타났으며, (2)이 P.C모델이 감쇠계수는 대체로, 철근콘크리트구조물 감쇠계수의 두배에 해당하는 값인 8%정도이며, (3) 이 모델은 접합부의 벌어짐과 미끄러짐에 의한 에너지소산을 통해서 2-3정도의 전체적인 변위연성비를 보여주었다.

해안지역 안정적 수자원 확보를 위한 기초적 연구 (Basic Study for Securing Stable Water Resources in Coastal Area)

  • 고병련;오영훈;안승섭
    • 한국환경과학회지
    • /
    • 제23권12호
    • /
    • pp.1977-1985
    • /
    • 2014
  • Many countries around the world are amplifying interest and studies on irrigation, flood control and environment with concern on serious water problems. Especially for irrigation in water supply vulnerable areas such as coastal areas - islands, business on underwater resource security facilities are promoted to secure stable water resources due to development of society and increase of life quality. Also, various policies such as reuse of leaking underwater, utilization of underwater at waterfront, and artificial recharge, etc are planned and designed. In order to develop small sized underwater resource secure technology, verification of seawater-freshwater interface is executed and how the balance between these will develop is a great interest of coastal areas - islands. In this study, seawater-freshwater interface behavior analysis experiment was conducted while reflecting properties of coastal areas - islands and executed hydraulic similitude of saltwater intrusion form control technology on abstraction.

확대모델을 이용한 특성화된 핀형상의 열전달평가 (An Evaluation of Heat Transfer Characteristics of Individualized Fin Type Using Large Scale Model)

  • 윤점열;강희찬;이관수;김무환
    • 설비공학논문집
    • /
    • 제8권1호
    • /
    • pp.166-175
    • /
    • 1996
  • In recent years, air-conditioning units designed with higher efficiency and more compactness are required due to emphasis on energy efficiency in home electrical appliances. This trend in the air-conditioning industries has accelerated the development of improved heat exchanger with a better performance in heat transfer aspects. In this study, experiments were performed to investigate the shape and configuration of fins affecting on the performance of the conventional fin-and-tube type heat exchanger equipped in a commercial air conditioners. The geometry similtude method was employed to measure the heat transfer coefficient and pressure drop. Experimental results show that this method is very useful to analyze the heat transfer characteristics of the fin-and-tube type heat exchanger. It is also found that the slit fin has better performance than the conventional fin type in the air conditioners. The present results indicate that heat transfer from the fin si influenced by the parameters such as the forming area of the slit fin, the type of interrupted surfaces like a louver or slit, slit patterns and slit raised direction, and it also affects the overall heat exchanger performance.

  • PDF

Experimental and numerical analysis of RC structure with two leaf cavity wall subjected to shake table

  • Onat, Onur;Lourenco, Paulo B.;Kocak, Ali
    • Structural Engineering and Mechanics
    • /
    • 제55권5호
    • /
    • pp.1037-1053
    • /
    • 2015
  • This paper presents finite element (FE) based pushover analysis of a reinforced concrete structure with a two-leaf cavity wall (TLCW) to estimate the performance level of this structure. In addition to this, an unreinforced masonry (URM) model was selected for comparison. Simulations and analyses of these structures were performed using the DIANA FE program. The mentioned structures were selected as two storeys and two bays. The dimensions of the structures were scaled 1:1.5 according to the Cauchy Froude similitude law. A shake table experiment was implemented on the reinforced concrete structure with the two-leaf cavity wall (TLCW) at the National Civil Engineering Laboratory (LNEC) in Lisbon, Portugal. The model that simulates URM was not experimentally studied. This structure was modelled in the same manner as the TLCW. The purpose of this virtual model is to compare the respective performances. Two nonlinear analyses were performed and compared with the experimental test results. These analyses were carried out in two phases. The research addresses first the analysis of a structure with only reinforced concrete elements, and secondly the analysis of the same structure with reinforced concrete elements and infill walls. Both researches consider static loading and pushover analysis. The experimental pushover curve was plotted by the envelope of the experimental curve obtained on the basis of the shake table records. Crack patterns, failure modes and performance curves were plotted for both models. Finally, results were evaluated on the basis of the current regulation ASCE/SEI 41-06.

계단식 보강토옹벽의 파괴 메카니즘 연구 (Failure Mechanism of Geosynthetic-Reinforced Segmental Retaining Wall in a Tiered Configuration)

  • 유충식;정혁상;이봉원
    • 한국지반신소재학회논문집
    • /
    • 제3권4호
    • /
    • pp.13-19
    • /
    • 2004
  • 본 연구에서는 계단식 보강토 옹벽의 파괴메카니즘 연구를 위해 모형실험을 실시한 내용을 다루었다. 보강토옹벽의 모형실험은 성균관대학교 내의 지반시험장에 시험 시공한 계단식보강토옹벽의 원형을 축소하여 모사하였으며, 상사법칙을 이용하여 보강통옹벽에 사용된 재료의 크기 및 물성치를 원형에 가깝도록 축소하여 파괴메카니즘 분석에 신뢰성을 높였다. 또한 파괴메카니즘 분석을 위해 종전의 재하실험 방식과는 달리 자중에 의한 파괴가 가능해짐으로써 원형에 가까운 파괴 형상을 모사 할 수 있었다. 모형 실험의 내용으로는 보강토옹벽의 영향인자라고 할 수 있는 이격거리의 변화 및 보강재 길이변화에 따른 파괴 양상을 분석하였다.

  • PDF

Centrifuge shaking table tests on a friction pendulum bearing isolated structure with a pile foundation in soft soil

  • Shu-Sheng, Qu;Yu, Chen;Yang, Lv
    • Earthquakes and Structures
    • /
    • 제23권6호
    • /
    • pp.517-526
    • /
    • 2022
  • Previous studies have shown that pile-soil interactions have significant influences on the isolation efficiency of an isolated structure. However, most of the existing tests were carried out using a 1-g shaking table, which cannot reproduce the soil stresses resulting in distortion of the simulated pile-soil interactions. In this study, a centrifuge shaking table modelling of the seismic responses of a friction pendulum bearing isolated structure with a pile foundation under earthquakes were conducted. The pile foundation structure was designed and constructed with a scale factor of 1:100. Two layers of the foundation soil, i.e., the bottom layer was made of plaster and the upper layer was normal soil, were carefully prepared to meet the similitude requirement. Seismic responses, including strains, displacement, acceleration, and soil pressure were collected. The settlement of the soil, sliding of the isolator, dynamic amplification factor and bending moment of the piles were analysed to reveal the influence of the soil structure interaction on the seismic performance of the structure. It is found that the soil rotates significantly under earthquake motions and the peak rotation is about 0.021 degree under 24.0 g motions. The isolator cannot return to the initial position after the tests because of the unrecoverable deformation of the soil and the friction between the curved surface of the slider and the concave plate.