• 제목/요약/키워드: Silk Suture

검색결과 34건 처리시간 0.024초

Gamma선 조사에 의한 의류제품의 멸균연구 (A Study on Sterilization of Medical Products by Gamma-irradiation.)

  • 정해원;정문식;문석형
    • 한국환경보건학회지
    • /
    • 제5권1호
    • /
    • pp.1-9
    • /
    • 1978
  • Biological safety, physico-chemical and microbiological experiments were carried out in order to study the possibility of radiation sterilization on medical products, such as polyethylene and polystyrene bottles, gauze sponges and surgical silk suture. Results are as follows: 1. Biological test on plastic samples as to acute systemic toxicity, eye irritation, skin irritation, pyrogen, haemolysis showed satisfactory results. But physico-chemically, the oxidizable matter, nonvolatile residues, residue on ignition seemed to be increased slightly in irradiated samples, though the experimental results were within the range of U.S.P. 19, N.F. and K.P. III. 2. After irradiation, both plastic and gauze sponges showed considerable decrease in pH. 3. Most medical products were sterilized by 1.5 Mard. For the sterilization of the suigical silk suture, 4.5 Mrad is required dul to its radiation resistant micro-organisms. 4. Biologically, total dose of 2.5 Mrad was safe enough to sterilize the medical products, and physico-chemically the results are acceptable according to U.S.P. 19 and K.P. III. However, better results may be expected when the quality of material and additives are improved.

  • PDF

가토 대퇴정맥 미세정맥문합술 후 정맥 문합부 재생에 관한 미세조직학적 연구 (ULTRASTRUCTURAL STUDY FOR VEIN REGENERATION AFTER MICROVASCULAR ANASTOMOSIS IN RABBIT FEMORAL VEIN)

  • 노홍섭;김철환;김경욱
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제33권4호
    • /
    • pp.340-349
    • /
    • 2007
  • Free flap transplantation with microvascular anastomosis has been successfully performed by development of surgical technique, materials and postoperative monitoring equipments of flap. But success rate of microvascular anastomosis is influenced by various factors, and failure rate is about 5-10%. The most influential factor for success rate is surgical technique and other factors that influence failure of microvascular anastomosis are ischemic time of free flap, thrombus formation of anastomosis region and vascular spasm. In this study, vascular patency and thrombus formation in experimental micro-venous anastomosis, and endothelial repair were observed with histologic analysis, scanning electron microscopy, transmission electron microscopic examination. The results were obtained as follows: 1. In vascular patency test in 30 minute and 7 days after micro-venous anastomosis with heparin irrigation, all of 12 anastomosis site were good vascular patency. 2. In thrombus formation in 2 weeks group(Experimental I), 2 site of 6 cases were observed thrombus, and in 4 weeks group(Experimental II), 1 site of 6 cases were observed thrombus. 3. In histologic examination, normal vein(Control Group) showed continued internal elastic lamina, well formed thick smooth muscle layer and connective tissue. The group of 2 weeks after microvenous anastomosis(Experimental I) showd locally recovered internal lamina, discontinued internal lamina, disorganized smooth muscle cells and granulation tissue around suture silk. In the group of 4 weeks after micro-venous anastomosis(Experimental II), anastomosis site showed almostly continued internal lamina, disorganized smooth muscle cells and cicartrized tissue around suture silk. 4. In scanning electron microscope examination in 2 weeks(Experimental I) after micro-venous anastomosis, mesh fibrin formation showed near to endothelial cells, and in 4 weeks after micro-venous anastomosis(EXperimental II), numerous blood cells and fibrin mesh formation was seen associated with irregular endothelial cell arrangement. 5. In transmission electron microscope examination in 2 weeks after micro-venous anastomosis(Experimental I), irregular arrangement of smooth muscle cells was seen adjacent to collagenized tissue around suture silk. In 4 weeks after micro-venous anastomosis(Experimental II), denuded venous wall composed of relatively well arranged smooth muscle cells was covered by endothelial cells, but fibroblast cells and foreign body giant cells near to suture silk was remained. From the results obtained in this study, results of good vascular patiency and anti-thrombotic effect of heparin were obtained as a local irrigation solution, and repair of venous endothelial cell was observed in 2 weeks after micro-venous anastomosis.

Reliability of Early Ambulation after Intradural Spine Surgery : Risk Factors and a Preventive Method for Cerebrospinal Fluid Leak Related Complications

  • Lee, Subum;Cho, Dae-Chul;Kim, Kyoung-Tae;Lee, Young-Seok;Rhim, Seung Chul;Park, Jin Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권5호
    • /
    • pp.799-807
    • /
    • 2021
  • Objective : Cerebrospinal fluid leakage related complications (CLC) occasionally occur after intradural spinal surgery. We sought to investigate the effectiveness of early ambulation after intradural spinal surgery and analyze the risk factors for CLC. Methods : For this retrospective cohort study, we enrolled 314 patients who underwent intradural spinal surgery at a single institution. The early group contained 79 patients who started ambulation after 1 day of bedrest without position restrictions, while the late group consisted of 235 patients who started ambulation after at least 3 days of bed rest and were limited to the prone position after surgery. In the early group, Prolene 6-0 was used as the dura suture material, while black silk 5-0 was used as the dura suture material in the late group. Results : The overall incidence rate of CLC was 10.8%. Significant differences between the early and late groups were identified in the rate of CLC (2.5% vs. 13.6%), surgical repair required (1.3% vs. 7.7%), and length of hospital stay (2.99 vs. 9.29 days) (p<0.05). Logistic regression analysis revealed that CLC was associated with practices specific to the late group (p=0.011) and the revision surgery (p=0.022). Conclusion : Using Prolene 6-0 as a dura suture material for intradural spinal surgery resulted in lower CLC rates compared to black silk 5-0 sutures despite a shorter bed rest period. Our findings revealed that suture - needle ratio related to dura defect was the most critical factor for CLC. One-day ambulation after primary dura closure using Prolene 6-0 sutures appears to be a costeffective and safe strategy for intradural spinal surgery.

External pancreatic ductal stenting in minimally invasive pancreatoduodenectomy: How to do it?

  • Ram Prakash Gurram;Harilal S L;Senthil Gnanasekaran;Satyaprakash Ray Choudhury;Biju Pottakkat;Kalayarasan Raja
    • 한국간담췌외과학회지
    • /
    • 제27권2호
    • /
    • pp.211-216
    • /
    • 2023
  • It has been shown that external pancreatic ductal stenting (EPDS) can reduce the incidence of clinically relevant postoperative pancreatic fistula. Although studies have described EPDS in open pancreaticoduodenectomy (PD), EPDS in minimally invasive PD has not been reported yet. Thus, the objective of this study was to describe the technique of EPDS in minimally invasive PD. The procedure was performed either laparoscopically or using a robot. Once PD was completed, key steps included triple enterotomy, threading of silk-suture through all enterotomies and exteriorization, completing posterior layer of pancreaticojejunostomy (PJ), railroading stent through preplaced silk-suture, intubation of stent into the pancreatic duct, completion of PJ, followed by hepaticojejunostomy and parietalization of jejunum at the stent exit site. EPDS in PD through a minimally invasive approach can be performed safely in selected cases with either a small-sized pancreatic duct or a soft pancreas.

Staple과 수종의 봉합물의 봉합부위 창상치유 조직반응 (TISSUE HEALING RESPONSE OF INCISED WOUND SUTURED BY STAPLES AND VARIOUS SUTURE MATERIALS)

  • 서민정;이재훈
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제18권3호
    • /
    • pp.500-514
    • /
    • 1996
  • The purpose of this study was to observe the tissue response in applying staples and various suture materials to both scalp and buccal mucosa in rabbits. 18 rabbits were divided into 6 groups. The incised wounds of both scalp and buccal mucosa were sutured with staples, polyglactin 910, chromic catgut, mer silk and nylon. The experimental animals were sacrificed after 1, 3, 5, 7, 10, 14 days posto peratively 3 animals at one time. The tissue was stained with Hematoxylin and eosin, and Masson's Trichrom. In light microscopic examinations, the sutured sites were examined histologi cally according to 6 degrees about inflammation and collagen deposit. The results were obtained as follows, 1. The chromic catgut, an absorbable suture material, was absorbed by 7 days, whereas polyglactin 910 and mersilk began to get absorbed after 7 days. 2. Mersilk manifested a broad range of inflammation in the scalp, and both staple and nylon showed a severe inflammatory reaction in the buccal mucosa. 3. With polyglactin 910, both tissue samples showed only minor foreign body reaction, however in the scalp, the process of fibrosis took place compara tively slowly, whereas in the buccal mucosa, it occurred promptly and manifested active fibrosis by 7 days. 4. Mersilk showed widespread a matrix formation in both scalp and buccal mucosa, and showed the most severe inflammatory reaction by 3 days, which did not seem to decrease even after 7 days. 5. Both staple and nylon showed relatively a severe inflammatory reaction, however fibrosis took place rather promptly compared to the other groups. 6. Generally, in the buccal mucosa fibrosis occurred more promptly than in the scalp in both control and experimental groups. 7. Retention of the suture material and stability of the knot were the best with the staple, and better stability was manifested by the multi-stranded poly glactin 910 and mersilk than singlestranded chromic catgut and nylon. From above results, in the buccal mucosa absorbable suture materials especially polyglactin 910 showed better response in the aspect of inflammatory reaction, while in the scalp monofilament suture materials such as staple and nylon manifested a early fibrosis and collagen formation.

  • PDF

Pain and quality of life related to suture removal after 3 or 7 days at the extraction sites of impacted lower third molars

  • Rodanant, Pirasut;Wattanajitseree, Kannika;Shrestha, Binit;Wongsirichat, Natthamet
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제16권2호
    • /
    • pp.131-136
    • /
    • 2016
  • Background: This study aimed to evaluate the patient's pain and quality of life after suture removal at either 3 or 7 days following the bilateral surgical extraction of impacted lower third molars. Methods: This study was a prospective, randomized controlled clinical trial carried out in 30 patients, who acted as their own control. Each patient required the bilaterally impacted mandibular third molars to be extracted. The impacted teeth were removed and the wound margins were approximated and sutured with black braided silk. The suture material was removed on day 3 on one side and on day 7 on the other. Each participant was asked to complete a questionnaire after the removal of the suture material on each designated day. Results: Regarding overall clinical symptoms, the mean VAS scores of male and female participants on day 3 were not significantly different from those on day 7. A significant difference was found in female participants, in that overall daily activity was better on day 7. There were significant differences in the ability to smile and laugh in both sexes and the ability to chew in the male participants was better on day 7. Conclusions: There were no significant differences in the patient's pain and quality of life between suture removal on day 3 or on day 7 following surgery to remove impacted lower third molars.

외상성 기관식도루 -수술체험 1례- (A Case Report of Traumatic Tracheoesophageal Fistula)

  • 최승호
    • Journal of Chest Surgery
    • /
    • 제27권10호
    • /
    • pp.888-892
    • /
    • 1994
  • Acquired, traumatic tracheoesophageal fistula [TEF] is rare and difficult problem to manage. This 55 years old man met with a roller accident of a tractor. During accident, he received a penetrating injury on the left upper sternal border. At local clinic, he received closed thoracotomy drainage [CTD]for relief of pneumothorax[left]. Three days after CTD, he complained abdominal pain and hematemesis. The endoscopy revealed large ulcer at the stomach, so he received subtotal gastrectomy. On 10th day post subtotal gastrectomy, he developed aspiration and coughing from a TEF. The esophagogram showed large TEF at the mid-trachea level. So he transfered to our hospital for operation. This patient was operated on for late TEF three weeks after injury. We have used absorble 4-0 Vicryl sutures to repair trachea. We repair all esophageal injuries with two layers of nonabsorbable silk suture. Where suture line on the esophagus, the strap muscle was interposed for reinforcement. And for feeding, the feeding jejunostomy was performed. Postoperatively the osteomyelitis of the manubrium site was developed, so on the 30th postoperative day, an ostectomy of manubrium, both clavicle and fight 1st, 2nd ribs, and the pectoralis major musculo-cutaneous flap coverage were performed.

  • PDF

Comparing intra-oral wound healing after alveoloplasty using silk sutures and n-butyl-2-cyanoacrylate

  • Suthar, Pratik;Shah, Sonal;Waknis, Pushkar;Limaye, Gandhali;Saha, Aditi;Sathe, Pranav
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제46권1호
    • /
    • pp.28-35
    • /
    • 2020
  • Objectives: The need for proper wound closure is of paramount importance after any intra-oral surgery. Various wound closure techniques have been described in literature using traditional non-absorbable suture materials. These include like synthetic absorbable sutures, surgical staples and tissue adhesives. Cyanoacrylates are among the most commonly used biocompatible tissue adhesives. To evaluate and compare intraoral wound healing using 3-0 silk sutures and n-butyl-2-cyanoacrylate after alveoloplasty. Materials and Methods: A total of 20 patients requiring bilateral alveoloplasty in the same arch (upper or lower) were included in this study. Patients with any pre-existing pathology or systemic disease were excluded. After alveoloplasty was performed, the wound was closed using 3-0 braided silk sutures on one side, and using n-butyl-2-cyanoacrylate bio adhesive on the other side. Patients were evaluated based on the following parameters: time required to achieve wound closure; the incidence of immediate and postoperative hemostasis; the time to the use of the first rescue medication; the side where pain first arises; and the side where wound healing begins first. Results: Compared to 3-0 silk sutures, cyanoacrylate demonstrated better hemostatic properties, reduced operative time, reduced postoperative pain and better wound healing. Conclusion: These data suggest that cyanoacrylate glue is an adequate alternative to conventional sutures to close the surgical wound after alveoloplasty, and better than are 3-0 silk sutures.

Redoable Tie-Over Dressing Using Multiple Loop Silk Threads

  • Jo, Hyeon Jong;Kim, Jun Sik;Kim, Nam Gyun;Lee, Kyung Suk;Choi, Jae Hoon
    • Archives of Plastic Surgery
    • /
    • 제40권3호
    • /
    • pp.259-262
    • /
    • 2013
  • After skin grafting, to prevent hematoma or seroma collection at the graft site, a tie-over dressing has been commonly used. However, although the conventional tie-over dressing by suture is a useful method for securing a graft site, refixation is difficult when repeated tie-over dressing is needed. Therefore, we recommend a redoable tie-over dressing technique with multiple loops threads and connecting silk threads. After the raw surface of each of our cases was covered with a skin graft, multiple loop silk thread attached with nylon at the skin graft margin. We applied the ointment gauze and wet cotton/fluffy gauze over the skin graft, then fixed the dressing by connecting cross-counter multiple loop thread with connecting silk threads. When we opened the tie-over dressing by cutting the connecting silk threads, we repeated the tie-over dressing with the same method. The skin graft was taken successfully without hematoma or seroma collection or any other complications. In conclusion, we report a novel tie-over dressing enabling simple fixation of the dressing to maintain proper tension for wounds that require repetitive fixation. Further, with this reliable method, the skin grafts were well taken.

Preparation and Properties of Silk Fibroin/Alginate Blend Sponges and its Application

  • Kweon, Hae-Yong;Lee, Kwang-Gill;Yeo, Joo-Hong;Woo, Soon-Ok;Han, Sang-Mi;Lee, Yong-Woo;Lee, Jang-Hern;Ham, Tae-Won;Ki, Chang-Seok;Park, Young-Hwan
    • 한국잠사학회:학술대회논문집
    • /
    • 한국잠사학회 2003년도 International Symposium of Silkworm/Insect Biotechnology and Annual Meeting of Korea Society of Sericultural Science
    • /
    • pp.55-56
    • /
    • 2003
  • Silk fibroin (SF) is one of the typical protein polymer produced by silkworm, Bombyx mori. SF has been used as textile fiber and surgical suture fur thousands of years due to its unique gloss, handle, and mechanical properties. Recently, SF has been intensively studied to diverse usage for biotechlological and biomedical fields because of their reproducibility, environmental compatibility, non-toxicity, and biological compatibility. Based on its biocompatibility, the possible uses of regenerated SF have been proposed including substrate for cell culture[1], enzyme immobilization[2], and matrix for drug release[3]. (omitted)

  • PDF