• Title/Summary/Keyword: Silicone support

Search Result 22, Processing Time 0.026 seconds

A Basic Study on the Development of Side Silicone Mold Support Device for Improving the Quality of FCP (FCP(Free-Form Concrete Panel) 품질 향상을 위한 측면 실리콘 거푸집 지지장치 개발 기초연구)

  • Jeong, Kyeongtae;Kim, Jihye;Lee, Donghoon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.165-166
    • /
    • 2023
  • Free-form Concrete Panel(FCP) is each panel that composes the concrete exterior skin of Free-form building. FCPs contain curved surfaces, and FCPs have different curvature, size, and angles. In order to manufacture FCP, high technology is required, and it is currently difficult to manufacture it according to the design shape. In particular, many errors occur in the side shape of FCP. This is because when the side silicone mold is applied, it is installed without a coupling method between molds and support device. In this study, basic research was conducted to develop a side silicone mold support device to solve the above problems. We classified the required performance and derived the detailed requirements. Also, Based on this, we drew the basic design of the support device. We plans to conduct design improvement, mock-up making, and FCP manufacturing experiments through future research.

  • PDF

The study on evaluation for PV module development using the silicone encapsulation (Silicone 봉지재를 이용한 태양광 모듈 제조 공정 및 평가에 대한 연구)

  • Jung, In-Sung;Lee, Bum-Su;Yang, O-Bong;Kang, Seong-Hwan;Kim, Jong-Il
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.137-142
    • /
    • 2011
  • Individual solar cells must be connected together to give the appropriate current and voltage levels and they must also be protected from damage by the environment. [1] PV module consists of a glass/ polymer encapsulation/ solar cell string/ polymer encapsulation/ back sheet. Usually, encapsulation materials is used EVA(ethylene vinyl acetate), PVB(polyvinyl butyral), PO(polyolefin)sheet. This study is about fabrication of module using silicone material instead of above them. We got to know advantage that is fabrication time and efficiency of modules.

  • PDF

Treatment of Tracheal Stenosis Using Silicone T-tube (기관협착증에 대한 Silicone T-tube의 치료경험)

  • 이종원;정종진;조용범
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1981.05a
    • /
    • pp.4.3-5
    • /
    • 1981
  • The Silicone tracheal T-tube was designed to maintain an adequate tracheal airway as well as to provide support in the stenotic reconstituted or reconstructed trachea. This report is our experiences with using silicone T-tube which were successfully used to two cases with extensive laryngotracheal trauma, and one case with decannulation difficulty for 9 months. Authors strongly believe that silicone T-tube is an excellent device out of consideration for our experienced cases, though many techniques have been applied for the treatments of tracheal problems.

  • PDF

Silicone Rubber Membrane Bioreactors for Bacterial Cellulose Production

  • Onodera, Masayuki;Harashima, Ikuro;Toda, Kiyoshi;Asakura, Tomoko
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.7 no.5
    • /
    • pp.289-294
    • /
    • 2002
  • Cellulose production by Acetobacter pasteurianus was investigated in static culture using four bioreactors with silicone rubber membrane submerged in the medium. The shape of the membrane was flat sheet, flat sack, tube and cylindrical balloon. Production rate of cellulose as well as its yield on consumed glucose by the bacteria grown on the flat type membranes was approximately ten-fold greater than those on the non-flat ones in spite of the same membrane thickness. The membrane reactor using flat sacks of silicone rubber membrane as support of bacterial pellicle can supply greater ratio of surface to volume than a conventional liquid surface culture and is promising for industrial production of bacterial cellulose in large scale.

Modified technique to fabricate a hollow light-weight facial prosthesis for lateral midfacial defect: a clinical report

  • Patil, Pravinkumar G.
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.3
    • /
    • pp.65-70
    • /
    • 2010
  • Large oro-facial defects result from cancer treatment consequences in serious functional as well as cosmetic deformities. Acceptable cosmetic results usually can be obtained with a facial prosthesis. However, retention of a large facial prosthesis can be challenging because of its size and weight. This article describes prosthetic rehabilitation of a 57-year-old man having a right lateral mid-facial defect with intraoral-extraoral combination prosthesis. A modified technique to fabricate a hollow substructure in heat-polymerizing polymethyl-methacrylate to support silicone facial prosthesis was illustrated. The resultant facial prosthesis was structurally durable and light in weight facilitating the retention with magnets satisfactorily. This technique is advantageous as there is no need to fabricate the whole prosthesis again in case of damage of the silicone layer because the outer silicone layer can be removed and re-packed on the substructure if the gypsum-mold is preserved.

Improving support performances of cone bolts by a new grout additive and energy absorber

  • Komurlu, Eren
    • Advances in materials Research
    • /
    • v.11 no.3
    • /
    • pp.237-250
    • /
    • 2022
  • The cone bolts with expanded front ends supply improved anchoring performances and increase energy absorbing capacities due to ploughing in the grouted drills. Within this study, use of a novel energy absorber for the cone bolt heads were investigated to assess its design in terms of supplying high support performances. Additionally, different grout material designs were tested to investigate whether the energy absorption capacities of the rock bolts can be improved using a silicone based thermoset polymer (STP) additive. To determine load bearing and energy absorption capacities, a series of deformation controlled pull-out tests were carried out by using bolt samples grouted in rock blocks. According to the results obtained from this study, maximum load bearing capacities of cone bolts are similar and mostly depend on the steel material strength, whereas the energy absorption capacity was determined to significantly vary in accordance with the displacement limits of the shanks. As a result of using STP additive and new polyamide absorber rings, displacement limits without the steel failure increase. The STP additive was found to improve the energy absorption capacities of grouted cone bolts. The absorber rings designed within this study were also assessed to be highly effective and able to double up the energy absorption capacities of the cone bolts.

Treatment of Decannulation Difficulty Using Silicone T-tube (silicone T-tube 삽입으로 치료된 기관 Cannula 발거곤난증 2례)

  • 김순웅;권혁진;윤병용
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1982.05a
    • /
    • pp.9.2-9
    • /
    • 1982
  • The incidence of decannulation difficulty included tracheal stenosis has markedly increased in recent years because of translaryngeal intubation and tracheostomy although advancing antibiotics and new treatment for these problems. Treatment has always been difficult but in mild cases, a new soft, flexible tracheal T-tube that designed to maintain an adequate tracheal airway as well as to provide support in the reconstructed trachea and in severe cases, transverse resection with subsquent end to end anastomosis has been used in recent years. Authors experienced 2 cases of tracheal stenosis and decannulation difficulty which developed after tracheostomy that was performed due to automobile accident and fall down respectively and using a silicone tracheal T-tube for 3 months good results were obtained. So authors reported with brief review of literatures.

  • PDF

Characteristics of Women Who Have Had Cosmetic Breast Implants That Could Be Associated with Increased Suicide Risk: A Systematic Review, Proposing a Suicide Prevention Model

  • Manoloudakis, Nikolaos;Labiris, Georgios;Karakitsou, Nefeli;Kim, Jong B.;Sheena, Yezen;Niakas, Dimitrios
    • Archives of Plastic Surgery
    • /
    • v.42 no.2
    • /
    • pp.131-142
    • /
    • 2015
  • Literature indicates an increased risk of suicide among women who have had cosmetic breast implants. An explanatory model for this association has not been established. Some studies conclude that women with cosmetic breast implants demonstrate some characteristics that are associated with increased suicide risk while others support that the breast augmentation protects from suicide. A systematic review including data collection from January 1961 up to February 2014 was conducted. The results were incorporated to pre-existing suicide risk models of the general population. A modified suicide risk model was created for the female cosmetic augmentation mammaplasty candidate. A 2-3 times increased suicide risk among women that undergo cosmetic breast augmentation has been identified. Breast augmentation patients show some characteristics that are associated with increased suicide risk. The majority of women reported high postoperative satisfaction. Recent research indicates that the Autoimmune syndrome induced by adjuvants and fibromyalgia syndrome are associated with silicone implantation. A thorough surgical, medical and psycho-social (psychiatric, family, reproductive, and occupational) history should be included in the preoperative assessment of women seeking to undergo cosmetic breast augmentation. Breast augmentation surgery can stimulate a systematic stress response and increase the risk of suicide. Each risk factor of suicide has poor predictive value when considered independently and can result in prediction errors. A clinical management model has been proposed considering the overlapping risk factors of women that undergo cosmetic breast augmentation with suicide.

DEVELOPMENT OF MEMBRANE AND COLD-CONDENSATION PROCESS FOR REMOVAL AND RECOVERY OF VOLATILE ORGANIC COMPOUNDS

  • Kim, Sung-Soo;Lee, Jong-Hwa;Kim, Hyunki;Kim, Sang-Yong
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.69-72
    • /
    • 2003
  • Volatile organic compounds (VOC) cause air pollution problem and deterioration of atmosphere of petrochemical and fine chemical plants. Hybrid process of membrane and cold-condensation were developed and it effectively removed and recycled the VOC. Operation parameters of the process were optimized to attain hish removal and recycle of VOC. Composite membranes for organic vapor separation were developed in this work by PDMS coating and plasma polymerization on polypropylene and polysulfone support membranes. PDMS and various silicone monomers were tested for several organic vapors such as benzene, toluene, TCE, and HCFC, which are produced in petrochemical and fine chemical industry and causes air pollution problems if are released to atmosphere. Composite membranes prepared in this work showed appreciable performance in terms of organic vapor removal and reuse. Performance variation of the membranes was correlated with their surface characteristics.

  • PDF

The Usefulness of Nasal Packing with Vaseline Gauze and Airway Silicone Splint after Closed Reduction of Nasal Bone Fracture

  • Kim, Hyo Young;Kim, Sin Rak;Park, Jin Hyung;Han, Yea Sik
    • Archives of Plastic Surgery
    • /
    • v.39 no.6
    • /
    • pp.612-617
    • /
    • 2012
  • Background Packing after closed reduction of a nasal bone fracture causes inconvenient nasal obstruction in patients. We packed the superior meatus with Vaseline gauze to support the nasal bone, and packed the middle nasal meatus with a Doyle Combo Splint consisting of an airway tube, a silastic sheet, and an expandable sponge to reduce the inconvenience. In addition, we aimed to objectively identify whether this method not only enables nasal respiration but also sufficiently supports the reduced nasal bone. Methods Nasal ventilation was measured via spirometry 1 day before surgery and compared to 1 day after surgery. To compare support of the reduced nasal bone by the 2 methods, 2 plastic surgeons assessed the displacementon X-rays taken after the surgery and after removing the packing. The extent of nasal obstruction, dry mouth, sleep disturbance, headache, and swallowing difficulty were compared with visual analog scales (VAS) on a pre-discharge survey. Results In the experimental group, the nasal respiration volume 1 day after surgery remained at $71.3%{\pm}6.84%$ on average compared to 1 day prior to surgery. Support of the reduced bone in the experimental group ($2.80{\pm}0.4$) was not significantly different from the control group ($2.88{\pm}0.33$). The VAS scores for all survey items were lower in the experimental group than in the control group, where a lower score indicated a lower level of inconvenience. Conclusions The nasal cavity packing described here maintained objective measures of nasal respiration and supported the reduced bone similar to conventional methods. Maintaining nasal respiration reduced the inconvenience to patients, which demonstrates that this packing method is useful.