• 제목/요약/키워드: Silicone replica technique

검색결과 52건 처리시간 0.018초

Marginal fit of three different nanocomposite inlays fabricated with computer-aided design/computer-aided manufacturing (CAD/CAM) technology: a comparative study

  • Hyunsuk Choi;Jae-Young Jo;Min-Ho Hong
    • Journal of Yeungnam Medical Science
    • /
    • 제41권2호
    • /
    • pp.80-85
    • /
    • 2024
  • Background: This study aimed to compare and evaluate the marginal fit of nanocomposite computer-aided design/computer-aided manufacturing (CAD/CAM) inlays. Three types of nanocomposite CAD/CAM blocks (HASEM, VITA Enamic, and Lava Ultimate) were used as materials. Methods: Class II disto-occlusal inlay restorations were prepared on a typodont mandibular right first molar using diamond rotary instruments. The inlays were fabricated using CAD/CAM technology and evaluated using the silicone replica technique to measure marginal gaps at five locations on each inlay. The data were analyzed by two-way analysis of variance and Tukey post hoc tests (α=0.05). Results: There were no significant differences in the marginal gaps based on the type of nanocomposite CAD/CAM inlay used (p=0.209). However, there was a significant difference in the marginal gaps between the measurement regions. The gingival region consistently exhibited a larger marginal gap than the axial and occlusal regions (p<0.001). Conclusion: Within the limitations of this in vitro study, the measurement location significantly influenced the marginal fit of class II disto-occlusal inlay restorations. However, there were no significant differences in the marginal gaps among the different types of CAD/CAM blocks. Furthermore, the overall mean marginal fits of the class II disto-occlusal inlay restorations made with the three types of nanocomposite CAD/CAM blocks were within the clinically acceptable range.

도재 소성 과정에서의 고온이 지르코니아 코어의 변연적합도에 미치는 영향 (Influence of High Temperature of the Porcelain Firing Process on the Marginal Fit of Zirconia Core)

  • 김재홍;김기백
    • 치위생과학회지
    • /
    • 제13권2호
    • /
    • pp.135-141
    • /
    • 2013
  • 본 연구는 치과에서 사용되는 심미 보철물 중에 하나인 지르코니아 기반의 전부도재관 제작 시 지르코니아 코어 위에 상부 도재를 축성하고 소성하는 과정에서 발생되는 고온이 완성된 전부도재관의 변연적합도에 미치는 영향을 분석함으로써 임상적 허용이 가능한지 알아볼 뿐 아니라, 치과보철치료를 위한 치과의사, 치과위생사, 치과기공사의 보철물 선택 시 임상적 참고자료로 제공할 목적으로 수행되었다. 심미에 가장 많은 영향을 미치는 상악 중절치를 지대치로 선정하여 동일한 모형 10개 제작 후 각각의 지대치에 적합한 지르코니아 코어를 제작하였다. 제작된 코어의 변연적합도 측정 후 코어 위에 상부 도재를 축성하여 전부도재관을 완성한 뒤 2차 측정을 실시하였으며, 측정 후 비교 분석 된 결과는 다음과 같다. 변연적합도는 지르코니아 코어 제작한 후 전부도재관으로 제작되는 과정에 따라 더 커졌으며, 통계적으로도 유의한 차이를 보였다(p<0.001). 그러나 전부도재관에서 총 80회 측정된 변연적합도의 값에서 임상적 허용 수치인 $120{\mu}m$을 넘지 않는 결과를 보였으며, 이와 같은 결과를 토대로 지르코니아 코어 위에 상부 도재 소성 시 변연적합도가 커지긴하나 임상적으로 허용이 가능하다는 결론을 도출하였다.

단일 절삭가공용 왁스 디스크 내에서 순차적 절삭가공 순서에 따른 크라운의 내면 및 변연 적합도 비교 (Comparison of internal and marginal fit of crown according to milling order in a single machinable wax disc)

  • 송준범;이종혁;하승룡;최유성
    • 대한치과보철학회지
    • /
    • 제59권4호
    • /
    • pp.395-404
    • /
    • 2021
  • 목적: 본 연구의 목적은 절삭가공이 순차적으로 진행됨에 따른 왁스 디스크의 구조적 안정성의 변화가 보철물의 적합도에 미치는 영향을 평가하는 것이다. 재료 및 방법: 삭제된 상악 제1대구치 인공치아를 이용하여 Ni-Cr 합금 표준모형을 제작하였고, 이를 스캔하여 크라운을 디자인한 뒤 왁스 디스크를 절삭가공하고 매몰 및 Ni-Cr 합금으로 주조하여 보철물을 제작하였다. 단일 왁스 디스크 내에서 중앙에 일렬로 위치한 납형들은 가장 처음 절삭가공 되는 WM1군부터 마지막에 절삭가공 되는 WM5군으로 총 5개의 군을 설정하였고 각 군의 수는 10개로 하였다. 적합도는 실리콘 레플리카 방법을 이용하여 변연 간극, 축면 간극, 선각간극, 교합면 간극을 측정하였다. 측정값은 일원배치분산분석(one-way ANOVA)을 사용하여 유의 수준은 95%로 그룹 간의 차이를 평가한 뒤, 사후 분석을 위해 Tukey HSD test를 시행하였다(α = .05). 결과: 각 군의 변연 간극은 WM1군(40.41 ± 2.15 ㎛), WM2군(40.44 ± 2.23 ㎛), WM3군(39.96 ± 2.25 ㎛), WM4군(39.96 ± 2.48 ㎛), WM5군(40.57 ± 2.53 ㎛)으로 각 군간에 유의한 차이를 보이지 않았다. 축면 간극, 선각 간극, 교합면 간극에서도 각 군간에 유의한 차이를 보이지 않았다. 결론: 단일 절삭가공용 왁스 디스크 내에서 순차적 절삭가공 시 크라운의 내면 및 변연 적합도는 절삭 순서에 영향 받지 않는 것으로 보인다.

주조에 의한 Core와 CAD-CAM에 의한 Core의 적합도 비교평가 (Comparison of the Marginal and Internal Fit on the Cast and CAD-CAM Cores)

  • 한만소;김기백
    • 치위생과학회지
    • /
    • 제12권4호
    • /
    • pp.368-374
    • /
    • 2012
  • 제한된 조건 하에서 수행된 본 연구에서 다음과 같은 결론을 얻었다. 1. 치과용 캐드캠을 이용하여 제작된 지르코니아 코어의 변연 및 내면 적합도보다 전통적인 방식을 이용하여 제작한 금속 코어가 모든 부위에서 우수하였다(p<.001). 2. 두 그룹 모두에서 적합도가 가장 미흡한 부분은 절단부였고, 축벽부가 가장 우수한 것으로 확인되었다. 본 연구 결과를 볼 때 아직까지는 치과용 캐드캠을 이용하여 보철물을 제작하는 것이 기존의 기공 방식을 이용하여 제작된 보철물의 적합도만큼 만족스럽지는 못하였으나 임상적 허용 범위 안에 존재하였다는 점에서 치과용 캐드캠은 임상적으로 사용이 가능한 것으로 판단된다. 앞으로 기계가 개선되고 가공 방식이 지금보다 발전한다면 기존의 기공 방식을 이용하여 제작되는 보철물의 완성도를 능가할 것으로 생각된다.

도재 소성과정이 Ni-Cr 금속도재관의 변연 및 내면 적합도에 미치는 영향 (Effect of Porcelain Firing Process on the Marginal and Internal Fit of Ni-Cr Alloy Metal-Ceramic Crown)

  • 김기백;김석환;김재홍
    • 치위생과학회지
    • /
    • 제14권3호
    • /
    • pp.405-410
    • /
    • 2014
  • 본 연구는 심미보철 치료에서 사용되는 금속도재관 제작시 Ni-Cr alloy 하부 구조물에 상부도재를 축성하고 소성하는 과정이 완성된 보철물의 적합도에 미치는 영향을 조사함으로써 임상적 허용을 재확인하기 위함이다. 1차로 lost wax technique으로 제작된 NCC (Ni-Cr alloy core)의 변연 및 내면 적합도를 측정하였고, 2차로 NCC에 상부도재 축성, 소성하여 금속도재관을 최종 완성하여 2차로 측정한 뒤비교한 결과는 다음과 같다. 금속도재관 제작 시 Ni-Cr alloy로 제작된 코어 위에 상부도재를 축성하고 소성하는 과정이 금속 도재관의 적합도를 악화시키는 결과를 보였으며, 부위 별 구분 없이 두 그룹에서 측정된 모든 값의 평균을 비교한 결과 NCC 그룹에서는 $67.1{\pm}23.3{\mu}m$, NMC 그룹에서는 $74.4{\pm}21.9{\mu}m$로 나타났으며 통계적으로 유의한 차이를 보였다(p<0.05). 이와 같은 결과를 토대로 Ni-Cr alloy로 금속도재관 제작 시 상부도재를 축성하는 과정에서 적합도를 악화시킨다는 결론을 얻었으나, 본 실험에서 측정된 결과 값은 임상적 허용 수치($120{\mu}m$)를 넘지 않아 적합도의 기준으로 평가하였을 때 임상적으로 허용 가능할 것으로 생각된다.

치과 CAD/CAM 시스템으로 제작한 코발트-크롬 소결 금속 코핑의 변연 및 내면 적합도 평가 (Evaluation of Marginal and Internal Gap of Cobalt-Chromium Sintering Metal Coping Fabricated by Dental CAD/CAM System)

  • 김동연;신천호;정일도;김지환;김웅철
    • 치위생과학회지
    • /
    • 제15권5호
    • /
    • pp.536-541
    • /
    • 2015
  • 본 연구에서는 CAD/CAM 시스템을 이용하여 제작한 코발트-크롬 주조 금속 코핑과 코발트-크롬 소결 금속 코핑의 변연 및 내면 적합도를 비교 평가하여 다음과 같은 결론을 도출하였다. 코발트-크롬 금속 코핑의 변연 및 내면 적합도를 비교 평가는 기존의 주조방식인 CCM 그룹보다 소결과정만으로 제작한 CSM 그룹이 전반적으로 모두 우수하였다. 또한 CSM 그룹의 변연 적합도는 임상적으로 허용할 수 범위인 $120{\mu}m$ 이내 존재하였다는 결과를 통해서 그동안 매몰, 소환, 주조인 복잡한 과정을 거치면서 보철물의 오차가 발생 하였으나 소결과정만으로 공정 과정의 오차를 줄임으로써 완성도 높은 코발트-크롬 금속 코핑 제작이 가능하다고 생각된다.

지르코니아 블록과 CAM 종류에 따른 코핑의 변연적합도와 기계적 특성 비교 (Comparison on marginal fitness and mechanical properties of copings with zirconia block and CAM type)

  • 정인성;전병욱;김원영;강재민
    • 대한치과기공학회지
    • /
    • 제39권2호
    • /
    • pp.75-82
    • /
    • 2017
  • Purpose: This study provided the basic data for selection the zirconia block and CAM by means of marginal fitness observations, flexural strength test and hardness test. Methods: Three dental zirconia blocks(ABCera, NaturaZ, ST98) and two dental milling machines(CAD/CAM MS, DWX-50) were used in this study. Metal abutment(diameter 10 mm, height 5 mm, inclined angle $3^{\circ}$ taper, 1 mm chamfer margin) was fabricated by Ti customized abutment, and then zirconia copings were fabricated for each ten specimens. Silicone replica technique was used to observe the marginal fitness of cross-sections with a stereomicroscope at ${\times}50$ magnification. The dental zirconia blocks was cut into 10 pieces each having a size of $25mm{\times}5mm{\times}1mm$, and fabricated according to the manufacturer's instructions, and flexural strength was measured using a universal testing machine. For hardness test, a micro Vickers hardness tester was used as it was in the flexural strength test. Statistical analysis was performed by one way ANOVA and post-test was performed by Scheffe test. Results: For marginal fitness of bucco-lingual axial, ZU group($59.7{\pm}10.3{\mu}m$) was the lowest, followed by RA, ZA, ZD, RD, RU. For marginal fitness of mesio-distal axial, ZU group($59.3{\pm}10.2{\mu}m$) was the lowest, followed by RA, ZA, RD, ZD, RU. One-way ANOVA showed statistically significant difference between groups(p<0.05). For flexural strength, ABCera block($718.0{\pm}57.2MPa$) was the highest, followed by NaturaZ, ST98. For hardness, ABCera block($1550.3{\pm}19.8Hv$) was the highest, followed by ST98, NaturaZ. There was no significant difference in flexural strength and hardness between blocks(p>0.05). Conclusion: Based on the results of this study, the type of dental zirconia block did influence the marginal fitness, and all dental zirconia blocks are expected to be suitable for clinical application. The highest flexural strength and hardness were ABCera block, and no statistically significant difference was observed.

지대치 형태에 따른 지르코니아 코어의 변연 적합도 (Marginal Adaptation of Zirconium Dioxide Core according to the Abutment Teeth)

  • 김기백;김석환;김재홍
    • 치위생과학회지
    • /
    • 제15권1호
    • /
    • pp.54-59
    • /
    • 2015
  • 본 연구는 시중에 널리 사용되는 치과용 지르코니아 코어를 이용하여 서로 다른 형태의 지대치를 대상으로 작업모형을 제작한 후, 치과용 스캐너를 통해 3차원 디지털 모형을 전환한 데이터를 토대로 지르코니아 코어를 제작하였으며, 각 실험군별 변연 적합도를 측정하여 비교분석하고자 하였다. 이와 같은 결과로 형태가 다른 지대치가 CAD/CAM system으로 치과 보철물 제작 시 적합도의 영향여부를 비교하였다. 제한된 조건 하에서 수행된 본 연구에서 다름과 같은 결과를 보였다. 지대치의 형태가 다른 작업모형으로 제작된 지르코니아 코어의 변연 적합도는 큰 차이가 없었다(p>0.05). 작업모형의 부위를 4등분으로 나누어 측정한 변연 적합도 또한 통계적으로 유의한 차이를 보이지 않았다. 결론적으로 3종류의 다른 지대치 모두 유사한 지르코니아 코어의 변연 적합도를 보였으며, 측정된 결과는 선행연구에 비추어 볼 때 임상적으로 허용 가능한 수치($100{\sim}120{\mu}m$)를 초과하는 실험군은 없었다. 이와 같은 결과를 토대로 다른 형태의 지대치를 사용하여 제작되었더라도 지르코니아 코어의 변연 적합도에 큰 영향을 주지 않을 것으로 생각된다.

치과 캐드캠 시스템의 가공 방식에 따른 금속 코핑의 적합도 비교 (Comparison of the Marginal and Internal Gap of Metal Coping according to Processing Method of Dental CAD/CAM System)

  • 김동연;전진훈;박진영;김지환;김혜영;김웅철
    • 치위생과학회지
    • /
    • 제15권1호
    • /
    • pp.12-17
    • /
    • 2015
  • 본 연구에서는 치과 CAD/CAM 시스템을 이용하여 SM 가공 방식으로 코핑을 제작 후 주조한 금속 코핑과, AM 가공 방식으로 코핑을 제작 후 주조한 금속 코핑과의 변연 및 내면 적합도를 비교 평가하여 다음과 같은 결과를 얻었다. SM 가공 방식과 AM 가공 방식의 변연 적합도 부분에서는 $120{\mu}m$ 임상적 허용 범위에 존재하였다. SM 가공 방식과 AM 가공 방식의 변연 적합도 및 내면 적합도는 통계적으로 유의한 차이가 있는 것으로 나타났다(p<0.05). SM 가공 방식과 AM 가공 방식으로 제작된 두 그룹의 전체 적합도와 4부분 부위별 적합도 측정은 SM 가공 방식보다 AM 가공 방식이 우수하였다. 결론적으로 금속 코핑의 변연 및 내면 적합도는 SM 가공 방식보다 AM 가공 방식이 우수하였고, 그 결과 값들은 임상적 허용범위 안에 존재하였다. 앞으로 치과분야에서 AM 가공 방식에 관한 연구는 계속되어야 하며, 보다 완성도 높은 금속 코핑 제작이 가능하다고 생각된다.

복합레진으로 제작한 인레이 보철물 구조에 따른 교합면 부위의 2차원 변연 적합도 및 내면 부위의 3차원 정확성 분석 (Analysis of the 2-dimensional marginal fit of the occlusal surface and the 3-dimensional accuracy of the inner surface of the occlusal surface according to the inlay prosthesis structure made of composite resin)

  • 김동연;이태희;박동인;박진영;정일도;이하나;김지환;김웅철
    • 대한치과기공학회지
    • /
    • 제41권1호
    • /
    • pp.21-27
    • /
    • 2019
  • Purpose: To evaluate 2D and 3D of occulsal, mesial-occlusal and mesial-occlusal-distal cavity of composite resin inlay. Methods: Abutment tooth 16, 36 of FDI system was selected for the study. Inlay prostheses classified as occlusal cavity (OC group), mesial-occlusal (MOC) and mesial-occlusal-distal cavity (MODC) were prepared using composite resin. Composite resin was injected with composite resin in prepared tooth cavity and then photopolymerized with UV light. Additional thermal polymerization was performed. Marginal gap of composite resin inlays were measured by digital microscope(x160) with silicone replica technique. The data was analyzed from statistical software for Kruskal-Wallis test (${\alpha}=0.05$). 3-dimensional analysis was analyzed through superimposition method. Results: The smallest 2D marginal fit measure of the three groups was $47.0{\pm}21.6{\mu}m$ in the MOC group. The largest 2D marginal was $69.1{\pm}33.8{\mu}m$ in the MODC group. In the trueness of the three groups, the most accurate figure was $14.4{\pm}2.3{\mu}m$ for the MODC group. In Precision, the most accurate figure was $14.5{\pm}4.3{\mu}m$ for the MODC group. Conclusion : In this study, 2D marginal fit of OC, MOC, and MODC cavities fabricated with composite resin was applicable to all clinical applications. In the 3D inner surface accuracy evaluation, the MODC group showed the accuracy results.