• 제목/요약/키워드: Silicone pad

검색결과 11건 처리시간 0.021초

디지털유방촬영에서 Geant4-GATE를 이용한 산란선의 영향분석과 감소방안에 관한 연구 (Analysis of Scatter Ray Distribution Using GEANT4-GATE Simulation and Effectiveness of Silicone Pad in Digital Mammography)

  • 김명수;김영근;장영일
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권3호
    • /
    • pp.175-180
    • /
    • 2019
  • In this study, we have researched the effectiveness of silicone pad. A distribution of scatter ray in mammography was evaluated using Monte-Carlo (MC) simulation technique and then a silicone pad was applied to remove the scatter ray for improving image quality. Molybdenum target and Molybdenum filter combination made a difference of 59.8% to a number of photon at 17.5 keV. On the other hand, Tungsten target and Rhodium filter showed a variation of 24.5% at 20 keV. Mean 68 of SNR was increased in Selenia and mean 1.04 of SNR was raised in Senographe. Silicone pad was significantly effective to reduce the scatter ray that was generated by primary X-ray. It can decrease an absorption rate of scatter ray to patient body and whilst it improve the image quality from increasing SNR.

실리콘 고무형을 이용한 미세복제기술 개발 (Development of micromolding technology using silicone rubber mold)

  • 정성일;임용관;박선준;최재영;정해도
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.46-49
    • /
    • 2003
  • Microsystem technology (MST) which originated from semiconductor processes has been widely spreaded into tile other industry such as sensors, micro fluidics and displays. The MST, however. has been troubled in spreading with its high cost and material limitations. So, in this paper, new process for micromolding technology using silicone rubber mold was introduced. Silicone rubber mold, which was fabricated by vacuum casting. can be transferred a master pattern to a final product with the same shape but different materials. In order to verify the possibility of application of silicone rubber mold to the MST, its transferability was evaluated. and then it applied to the fabrications of polishing pad and PDP barrier ribs.

  • PDF

실리콘 고무형을 이용한 미세복제기술 개발 (Development of Micromolding Technology using Silicone Rubber Mold)

  • 정성일;임용관;김호윤;최재영;정해도
    • 대한기계학회논문집A
    • /
    • 제27권8호
    • /
    • pp.1380-1387
    • /
    • 2003
  • Microsystem technology (MST) which originated from semiconductor processes has been widely spreaded into the other industry such as sensors, micro fluidics and displays. The MST, however, has been troubled in spreading with its high cost and material limitations. So, in this paper, new process for micromolding technology using silicone rubber mold was introduced. Silicone rubber mold, which was fabricated by vacuum casting, can be transferred a master pattern to a final product with the same shape but different materials. In order to verify the possibility of application of silicone rubber mold to the MST, its transferability was evaluated, and then it applied to the fabrications of polishing pad and PDP barrier ribs.

BTCA와 실리론 처리 면직물의 역학적 성질 (Mechanical Properties of Cotton Fabric Treated with BTCA and Polyalkkyleneoxide modified aminofunctional silicone)

  • 조성교;남승현
    • 한국의류학회지
    • /
    • 제24권7호
    • /
    • pp.987-994
    • /
    • 2000
  • Cotton fabrics were finished with mixture of BTCA and silicone by pad-dry-cure process to achieve better mechanical properties than those of finished with BTCA alone. The changes of mechanical properties o( finished cotton fabrics were measured with by the KES-FB System and the hand values were calculated from the data of mechanical properties. With the durable press finish with BTCA tensile, bending, shear and compression properties increased. In hand values, Stiffness Crispness and Anti-Drape Stiffness increased, and Fullness & Softness decreased. Whereas silicone treatment reduced bending and shear properties and improved tensile and compressional resilience. Thus, Stiffness Crispness and Anti-Drape Stiffness decreased, and Fullness & Softness increased. These results indicated that BTCA treatment restricts fiber/yarn mobility in the fabric structure due to crosslinking, but silicone treatment reduces inter-fiber and inter-yarn frictional forces. Therefore, finish with mixture of BTCA and silicone provided cotton fabrics with a lower Stiffness, Crispness and Anti-Drape Stiffness and a higher Fullness & Softnesss than finish with BTCA alone.

  • PDF

BTCA와 실리콘 처리 면직물의 물리적 성질 (Physical Properties of Cotton Fabric Treated with BTCA and P olyalkyleneoxide-modified amino-functional silicone)

  • 남승현;유효선
    • 한국의류학회지
    • /
    • 제22권4호
    • /
    • pp.525-534
    • /
    • 1998
  • Cotton fabrics were finished with mixture of BTCA(1,2,3,4,-butanetetracarboxylic acid) and polyalkyleneoxide-modified amino-functional silicone by pad-dry-cure process to achieve better DP performance with a higher retention of physical properties as compared to those of finished with BTCA alone. The results indicated that BTCA improved the wrinkle recovery but reduced significantly the tensile and tear strength of the treated fabrics. Whereas silicone imparted a lower wrinkle recovery, a lower loss of tensile strength than BTCA, in addition improved considerably the tear strength owing to reduction in inter-fiber and/or inter-yarn frictional forces. The concentration and curing temperature needed to enhance physical properties were as follows; for BTCA treatments 6%, at 18$0^{\circ}C$, for silicone treatments 1% at 14$0^{\circ}C$. This optimum concentration of silicone was observed by using the mixture of BTCA and silicone. The wrinkle recovery and DP rating of cotton fabrics treated with mixture of 4% BTCA and 1% silicone at a curing temperature of 17$0^{\circ}C$ was similar to those of treated with 6% BTCA at a curing temperature of 18$0^{\circ}C$, and other performance properties observed were; an increase in tensile strength, extension, toughness, abrasion resistance and moisture regain due to the reduction of BTCA concentration and curing temperature, futhermore an improvement in bending and surface properties due to the lubricating effect of silicone. On the other hand 1% aqueous silicone solution showed the lowest surface tension. Such nonionic surface activity resulted in a more uniform and rapid deposition of BTCA on the fiber or fabric.

  • PDF

웨이퍼 폴리싱 공정의 회전속도와 진폭속도에 따른 가공특성 연구 (A Study on the Characteristics of a Wafer-Polishing Process at Various Machining and Oscillation Speed)

  • 이은상;이상균;김성현;원종구
    • 한국기계가공학회지
    • /
    • 제11권1호
    • /
    • pp.1-6
    • /
    • 2012
  • The polishing of silicon wafers has an important role in semiconductor manufacturing. Generally, getting a flat surface such as a mirror is the purpose of the process. The wafer surface roughness is affected by many variables such as the characteristics of the carrier head unit, operation, speed, the pad and slurry temperature. Optimum process conditions for experimental temperature, pH value, down-force, slurry ratio are investigated, time is used as a fixed factor. This study carried out a series of experiments at varying platen, chuck rpm and oscillation cpm taking particular note of the difference between the rpm and the affect it has on the surface roughness. In this experiment determine the optimum conditions for polishing silicone wafers.

SMA를 이용한 캡슐 내시경의 이동메커니즘 설계 및 제작 (Design and fabrication of the Locomotive Mechanism for Capsule Endoscopes Using Shape Memory Alloys (SMA))

  • 이승학;김병규;박종현;박종오
    • 대한기계학회논문집A
    • /
    • 제27권11호
    • /
    • pp.1849-1855
    • /
    • 2003
  • Newly commercialized wireless capsule endoscope has many advantages compared to conventional push-type endoscopes. However, it is moved by the peristaltic waves. Therefore, it can not diagnose desired zones actively. In this paper, a locomotive mechanism for wireless capsule endoscope is proposed to increase the efficiency of endoscopy. We designed and fabricated a prototype using SMA springs and bio-mimetic clamping device. The hollow space in the prototype is allocated for further system integration of a camera module, a RF module and a battery. And the sequential control scheme is employed to improve the efficiency of its locomotion. To validate the performance of the locomotive mechanism, experiments on a silicone rubber pad and in vitro tests are carried out. The results of the experiments indicate that proposed mechanism is effective in harsh environments such as digestive organs of a human.

전통한지를 활용한 패션 악세서리 상품개발 (제1보) -실리콘 수지로 처리된 한지의 물성변화- (A Study on the Fashion Accessary Product Development by Use of Korean Traditional Hanji (Part I) -Physical Properties of the Korean Traditional Paper(Hanji) Treated with Silcone resin-)

  • 김은아;유효선;김용숙
    • 한국의류학회지
    • /
    • 제30권3호
    • /
    • pp.481-486
    • /
    • 2006
  • 한지를 의류용으로 사용하기 위한 시도들이 있었지만, 습윤상태에서 물리적 성질이 크게 감소한다는 문제점 때문에 많은 한계를 가지고 있었다. 따라서 한지의 습윤상태에서의 물리적 성질을 향상시키기 위해 내수성을 부여하고자, 실리콘 수지를 이용하여 한지에 발수가공을 행하였다. 패드-드라이-큐어 방법을 사용하여 처리하였고, 가공의 최적조건을 알아보기 위해 수지의 농도와 촉매의 농도, 큐어링 시간과 온도를 변화시켜 실험하였다. 한지의 발수도, 강연도, 방추도를 측정하였고, 습윤과 건조상태에서의 인장강도, 인열저항 마찰저항을 비교하였다. 그 결과 한지의 발수가공을 위한 최적처리조건은 실리콘 수지농도 40g/l, 촉매농도는 수지농도의 1/2인 20g/l, 큐어링 온도 160$^{circ}C$, 큐어링 시간 120초였다. 가공 후에도 한지의 유연성은 크게 저하되지 않았으며, 방추도는 약간 증가하였다. 가공 후, 건조상태에서의 인장강도, 인열저항은 큰 변화가 없었으나 내마모도는 증가하였고, 습윤상태에서의 인장강도, 인열저항, 내마모도 모두 증가하였다.

공진형 MEMS 가속도계의 음향가진 반응특성 연구 (A Study on Acoustic and Vibratory Response of a MEMS Resonant Accelerometer)

  • 이상우;이형섭;유명종;김도형
    • 전기학회논문지
    • /
    • 제64권9호
    • /
    • pp.1330-1336
    • /
    • 2015
  • It is necessary to study on acoustic and vibratory response of a MEMS resonant accelerometer before applying to military applications. In this paper, we analyze why the resonant accelerometer reacts to an acoustic wave and a high frequency vibration. And we describe experimental results on acoustic and vibratory response of the accelerometer. The accelerometer consists of a proof mass and a dual ended tuning fork. It is a differential resonant accelerometer with arranging a pair of accelerometers. The mode shape was analyzed to find out the input mode frequency by using a FEM simulation. Some experiments regarding the acoustic noise was carried out by using a tweeter and a microphone in the anechoic room. Results showed that the accelerometer reacted to the acoustic wave and vibration which had the input mode frequency as we had expected. We showed experimentally not only that the susceptibility of the accelerometer to an acoustic wave was 70 dB but also that the effectiveness of applying an acoustic absorber and a metal case was 20 dB, respectively. Also, we could minimize the vibratory response property of the accelerometer by installing a IMU with a silicone rubber mount pad.

하악골 이단술을 시행한 환자에서 중립대를 활용한 상하악 총의치 수복 증례 (Neutral zone approach for rehabilitation in a patient who underwent mandibulotomy: A case report)

  • 신희도;이학영;김지환
    • 대한치과보철학회지
    • /
    • 제61권1호
    • /
    • pp.18-25
    • /
    • 2023
  • 본 증례는 65세 남환으로, 10년 전 편도암으로 하악골이단술을 시행한 환자에서 중립대를 활용한 상하악 총의치 수복 증례이다. 본 환자는 무치악 기간이 짧아 치초제의 흡수가 거의 없으며, 혀의 운동기능에도 이상이 없었지만, 수술 이후의 변화로 인해 하악의 후구치 삼각융기가 상악의 구상절흔보다 안쪽에 위치해 있으며 하악의 구치부 치조제는 상대적으로 설측으로 돌아간 구조를 보였다. 만약 통상적으로 해부학적 지표를 참고하여 치아를 배열한다면, 혀의 기능 공간을 침범하게 되며, 이는 의치의 안정성을 저하시킬 것이다. 이런 경우 중립대 개념을 적용한 의치의 제작은 좋은 참고점이 될 수 있을 것이다. 연성 이장재를 사용하여 중립대를 인기하였으며, 이를 인덱스로 제작하여 치아배열을 시행하였다. 중립대의 가장 큰 장점은 의치의 안정을 얻는 것에 있다. 본 환자의 경우 하악 좌측 구치부가 혀 공간을 침범하지 않도록 구치 치아의 설측배열 한계를 얻기 위해 중립대 기법을 적용하였다. 특히, 치조제의 흡수로 의치의 안정성을 얻기 어려운 난증례 환자의 경우 이러한 방법을 사용한다면 의치의 안정성 면에서 더욱 좋은 결과를 얻을 수 있을 것이라 보기에 본 증례를 보고하는 바이다.