• 제목/요약/키워드: Silicone implant

검색결과 78건 처리시간 0.025초

Methylene Blue Dye-Induced Skin Necrosis in Immediate Breast Reconstruction: Evaluation and Management

  • Lee, Ji Hwan;Chang, Choong Hyun;Park, Chan Heun;Kim, June-Kyu
    • Archives of Plastic Surgery
    • /
    • 제41권3호
    • /
    • pp.258-263
    • /
    • 2014
  • Background For early breast cancer patients, skin-sparing mastectomy or nipple-sparing mastectomy with sentinel lymph node biopsy has become the mainstream treatment for immediate breast reconstruction in possible cases. However, a few cases of skin necrosis caused by methylene blue dye (MBD) used for sentinel lymph node localization have been reported. Methods Immediate breast reconstruction using a silicone implant was performed on 35 breasts of 34 patients after mastectomy. For sentinel lymph node localization, 1% MBD (3 mL) was injected into the subareolar area. The operation site was inspected in the postoperative evaluation. Results Six cases of immediate breast reconstruction using implants were complicated by methylene blue dye. One case of local infection was improved by conservative treatment. In two cases, partial necrosis and wound dehiscence of the incision areas were observed; thus, debridement and closure were performed. Of the three cases of wide skin necrosis, two cases underwent removal of the dead tissue and implants, followed by primary closure. In the other case, the breast implant was salvaged using latissimus dorsi musculocutaneous flap reconstruction. Conclusions The complications were caused by MBD toxicity, which aggravated blood disturbance and skin tension after implant insertion. When planning immediate breast reconstruction using silicone implants, complications of MBD should be discussed in detail prior to surgery, and appropriate management in the event of complications is required.

Scarpa씨 근막을 이용한 이차 비성형술 (Secondary Rhinoplasty Using Scarpa's Fascia)

  • 오광진;김종진;이내호;양경무
    • Archives of Plastic Surgery
    • /
    • 제35권1호
    • /
    • pp.86-91
    • /
    • 2008
  • Purpose: The performance of rhinoplasty on the patient who has already undergone unsatisfactory results or complications after augmentation rhinoplasty is a challenging surgical problem. Because the dead space is remained after removal of the foreign body and the thickness of the skin is not even, the deformity would be more conspicuous if the nose is reconstructed again with hard implant only or autogenous cartilage. In these cases, the autogenous fascia can be used to get a good result. We present our clinical experience of secondary rhinoplasty using Scarpa's fascia of lower abdomen. Methods: Thirty-two patients underwent the procedure from March of 2002 to February of 2007. Nine patients were reconstructed with Scarpa's fascia only, eighteen patients were reconstructed with silicone implant and fascia, and five patients were reconstructed with cartilage and fascia for secondary rhinoplasty. Results: There were no major complications. Most of the patients were satisfied with the results. The deviation of the silicone implant and postoperative hypertrophic scar of the donor site were seen in one case each. Postoperative absorption of fascia were seen in two cases using Scarpa's fascia only. Conclusion: Secondary rhinoplasty using Scarpa's fascia is very useful method which offers a minimized donor site scar, low complication rate, shorter operation time and patient satisfaction and prevents the alopecia caused by the harvest of temporalis fascia.

골절제술과 융비술의 동시 시행에 의한 외상성 비변형의 교정 (Combination of Nasal Ostectomy and Augmentation Rhinoplasty in the Correction of Traumatic Nasal Deformity)

  • 김성남;김의식;황재하;김광석;이삼용;조백현
    • Archives of Plastic Surgery
    • /
    • 제32권5호
    • /
    • pp.555-560
    • /
    • 2005
  • The nose is shaped as a pyramid and is the most prominent portion of the face. Nasal bone fractures are thus more frequent than those of the maxilla and zygoma. Whether the nasal bone fractures are corrected or not due to unnecessity of surgical treatment, the incidence of posttraumatic deformity occurs frequently. In Asian patients, even the corrected noses look low-lying and flat. To resolve these problems, we corrected the posttraumatic deformity of the nose with a combined procedure of nasal ostectomy and augmentation rhinoplasty. From 2000 to 2004, this procedure was performed in fifteen patients with posttraumatic nasal deformity. There were four female and eleven male patients with an average age of 32 years(range 19 to 52 years). All patients had previous trauma history. Of these, closed reduction was performed on 13 patients and no treatment was 2 patients. The deformed noses were corrected through lower columellar incision, by ostectomy or osteomy, and augmentation with silicone implant. We gained satisfactory results of correcting the deformed noses, except one case with implant deviation. Our method for the correction of traumatic nasal deformity proves to be simple and safe. The camouflage effect with silicone implant overcomes an unsatisfactory correction and brings a excellent cosmetic results.

실리콘겔 인공유방의 기계적 및 물리화학적 특성에 대한 연구 (Study for Mechanical and Physicochemcial Properties of Silicone Gel Filled Mammary Implants)

  • 백홍;장동혁;송정민;이승영;서무엽;박길종;맹은호
    • 대한의용생체공학회:의공학회지
    • /
    • 제33권2호
    • /
    • pp.89-97
    • /
    • 2012
  • The purpose of this study is to develop the guideline of the physicochemical and mechanical properties evaluation for silicone gel filled breast implants. First of all, the use and development status for silicone gel filled breast implants were investigated, and then, standard and criteria about performance evaluation established by the international organizations such as ASTM, FDA guidance and ISO were examined. To evaluate the mechanical properties, data research and testing for breaking strength, elongation, tensile set, joint intensity, silicone gel cohesion, weight loss from heating, static rupture resistance, impact resistance test, fatigue test, and gel bleed were performed. On the other hand, to evaluate the physicochemical properties, volatile matter, extent of cross linking, heavy metals, and extractable were analyzed. In this study, results for general function, mechanical properties and physicochemical properties were examined and reviewed for the accordance with international standard, and objective and standardized guideline was provided.

개의 건성각결막염에 의한 각막천공을 안구내용물적출술과 실리콘볼 삽입 후 각막이식을 적용하여 치료한 증례 (Evisceration and Intrascleral Silicone Ball Prosthesis with Penetrating Keratoplasty on Perforated Corneal Ulcer Secondary to KCS in a Shih Tzu Dog)

  • 김종민;김종열;김황민;장세웅;정인성;최석화
    • 한국임상수의학회지
    • /
    • 제32권4호
    • /
    • pp.356-358
    • /
    • 2015
  • 큰 크기의 각막천공에 안내용물 손상이 된 눈을 안구적출술을 시도하지 않고, 안구내용물적출술과 실리콘볼 삽입후 각막이식을 적용하여 치료하여 안구적출술보다 미용상 만족한 눈의 외관을 얻은 증례를 소개 하였다.

구강내에서 임플랜트 지대주 형성 시 내부연결방식과 외부연결방식간의 열전달 효과 비교 (THE COMPARATIVE STUDY OF THERMAL INDUCTIVE EFFECT BETWEEN INTERNAL CONNECTION AND EXTERNAL CONNECTION IMPLANT IN ABUTMENT PREPARATION)

  • 허중보;고석민
    • 대한치과보철학회지
    • /
    • 제45권1호
    • /
    • pp.60-70
    • /
    • 2007
  • Statement of problem: The cement-type abutment would be needed for the reduction of its body in order to correct the axis and to assure occlusal clearance. In the case of intraoral preparation, there is a potential risk that generated heat could be transmitted into the bone-implant interface, where it can cause deterioration of tissues around the implant and failed osseointegration. Purpose: The purpose of this study was to assess the difference of the heat transmitting effect on external and internal connection implant types under various conditions. Material and method: For evaluating the effects of alternating temperature, the thermocoupling wires were attached on 3 areas of the implant fixture surface corresponding to the cervical, middle, and apex. The abutments were removed 1mm in depth horizontally with diamond burs and were polished for 30 seconds at low speed with silicone points using pressure as applied in routine clinical practice. Obtained data were analyzed using Mann-Whitney rank-sum test and Wilcoxon / Kruskal-Wallis Tests. Result: Increased temperature on bone-implant interface was evident without air-water spray coolant both at high speed reduction and low speed polishing (p<.05). But, the difference between connection types was not shown. Conclusion: The reduction procedure of abutment without using proper coolant leads to serious damage of oral tissues around the implant irrespective of external and internal connection type.

BellaGel breast implant: 6-Year results of a prospective cohort study

  • Oh, Joon Seok;Jeong, Jae Hoon;Myung, Yujin;Oh, Jeongseok;Kang, Shin Hyeok;Park, Eonju;Kim, Ara;Bang, Sa Ik;Heo, Chan Yeong
    • Archives of Plastic Surgery
    • /
    • 제47권3호
    • /
    • pp.235-241
    • /
    • 2020
  • Background This is the first clinical study conducted among Asian women using breast implants manufactured by an Asian company. Four-year data regarding the safety and efficacy of BellaGel breast implants have already been published, and we now report 6-year data. Methods This study was designed to take place over 10 years. It included 103 patients who underwent breast reconstruction or augmentation using BellaGel breast implants. The rates of implant rupture and capsular contracture were measured and analyzed to evaluate the effectiveness of the breast implant. Results At patients' 6-year postoperative visits, the implant rupture and capsular contracture rates were 1.15% and 2.30%, respectively. The implant rupture rate was 3.77% among reconstruction cases and 0% among augmentation cases. The capsular contracture rate was 5.66% among reconstruction cases and 0.83% among augmentation cases. Conclusions The 6-year data from this planned 10-year study suggest that the BellaGel cohesive silicone gel-filled breast implant is an effective and safe medical device that can be used in breast reconstruction and augmentation.

쥐의 두개골에서 융비술에 사용되는 수종의 이식재에 대한 조직학적 연구 (A HISTOLOGICAL STUDY ON SEVERAL IMPLANTS FOR AUGMENTATION RHINOPLASTY IN MOUSE CALVARIUM)

  • 김현섭;국민석;박홍주;오희균;김형석
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제29권4호
    • /
    • pp.289-300
    • /
    • 2007
  • Purpose: This study was aimed to histologically evaluate $Silicone^{(R)}$, $Gore-tex^{(R)}$, $AlloDerm^{(R)}$, and $Medpor^{(R)}$ implants for augmentation rhinoplasty after graft in the subperiosteum of mural calvarium respectively. Materials and method: Twenty four male ICR mice were used. $Silicone^{(R)}$, $Gore-tex^{(R)}$, $AlloDerm^{(R)}$, and $Medpor^{(R)}$ were grafted respectively in the subperiosteum of frontal bone. Animals were sacrificed at 1 week, 4 week and 8 week after graft. Histological observation was performed after H&E staining. Results: All groups were healed without any extrusion of implant materials and inflammatory cell infiltration. In Silicone group, $Silicone^{(R)}$ was well enclosed by thin fibrous tissue at 1 week, which became thicker and stable at 4 weeks and 8 weeks. And there was no destruction or resorption of $Silicone^{(R)}$ In Gore-tex group, there was no destruction or resorption of $Gore-tex^{(R)}$. Thin fibrous tissue and cell infiltration from peripheral tissue were observed at 1 week, 4 weeks and 8 weeks. In AlloDerm group, $AlloDerm^{(R)}$ was enclosed by fibrous tissue. Cell infiltration was observed at 1 week, 4 weeks and 8 weeks. In Medpor group, there was no inflammation, destruction or resorption of $Medpor^{(R)}$ and it was contacted directly to the bone without interposition of fibrous tissue. Porous area was filled by bone or soft tissue. Conclusion: These results suggest that $Gore-tex^{(R)}$, $AlloDerm^{(R)}$, and $Medpor^{(R)}$ graft are more stable than $Silicone^{(R)}$ graft and that $Silicone^{(R)}$, $Gore-tex^{(R)}$, $AlloDerm^{(R)}$ are appropriate for graft on nasal tip and $Medpor^{(R)}$ is appropriate for graft on nasal dorsum.