• 제목/요약/키워드: Silicone fluid

검색결과 106건 처리시간 0.03초

전침 시술시 침 재료에 따른 부식성 평가 (The Corrosiveness Evaluation according to the Needle Material in the Electroacupuncture Operation)

  • 권오상;최광호;조성진;류연희;최선미;이상훈
    • Korean Journal of Acupuncture
    • /
    • 제29권2호
    • /
    • pp.216-223
    • /
    • 2012
  • Objectives : Electroacupuncture is widely used because of its diverse curative influence. However, its electrical safety is not guaranteed when applied on the human body. Therefore, in this study, we did research on the corrosiveness of electroacupuncture when applied on the body fluid. Methods : We did research using acupuncture needles which were made of STS304 or STS316 and which were coated or not coated in silicone. They were 0.25 mm in diameter and 40 mm in length. We immersed them to the depth of about 1cm in Hank's Solution and gave a stimulus in 120 Hz for 60 minutes. Then, we measured the pH of Hank's solution and mass of needles and observed their shape. Results : Acupuncture needles which were made of STS304 corroded more easily than those which were made of STS316 when they were applied on the human body. Acupuncture needles which were coated in silicone corroded much more easily than those which were not coated in silicone when they were applied on the body fluid. Conclusions : In this study, we did research on the corrosiveness of electroacupuncture when it is applied on the body fluid using several acupuncture needles. We made a conclusion that when acupuncture needles were applied on the body fluid, the coated one made of STS304 corrodes more easily than the uncoated one made of STS316. We hope that additional further researches on the effect of the corrosiveness of an acupuncture needle will be carried out.

제어 시스템 적용을 위한 ER유체의 빙햄 특성에 관한 기초적 연구 (A Fundamental Study on Bingham Characteristics of Electro-Rheological Fluids for Control System Application)

  • 장성철;정영빈;장길식
    • 한국기계가공학회지
    • /
    • 제3권3호
    • /
    • pp.86-92
    • /
    • 2004
  • This paper describes the properties of temperature-viscosity characteristics of hydrous and anhydrous electro-rheological fluids containing starch and titanium particle in silicone oil ER effects arise from electrostatic forces between the starch particles and titanium particles dispersed to the electrically insulating silicone oil induced when electric field is applied ER fluids under electric field control have been found to provide resonable estimates of ER fluid viscosity variation characteristics. Yield shear stress of the ER fluids were measured the couette cell type rheometer as a function of electrlc fields. The outer cup is connected to positive electrode(+) and bob becomes ground(-). The electrie field is applied by high voltage DC power supply. In this experiment shear rates were increased from 0 to 200 $s^{-1}$ in 2 minutes. The ER fluid's viscosity change is very small and stable at the temperature range of $40^{\circ}C$ to $60^{\circ}C$. Therefore, applications of a new ER fluid to control systems application are suitable.

  • PDF

인산화 전분 ER 유체의 트라이볼로지 특성 (Tribological Characteristics of Phosphorated Starch Based Electrorheological Fluid)

  • 장민규;이철희;최재영;손정우;최승복
    • Tribology and Lubricants
    • /
    • 제26권1호
    • /
    • pp.7-13
    • /
    • 2010
  • This experimental study presents tribological characteristics under boundary lubrication contacts associated with electrorheolocal (ER) fluid. ER fluid is prepared by using phosphorated starch particles and silicone oil. Experimental apparatus of tribological tester is designed and constructed to evaluate tribological characteristics of pin specimens. Wear tests under boundary lubrication of ER fluid are experimentally performed under consideration of several operational factors such as normal load, sliding distance, sliding speed and specimen materials: steel, copper and aluminum. After wear test, microscopic surface changes of the worn pin specimens are analyzed in order to investigate measured wear characteristics by using the scanning electron microscope (SEM) as well as surface profilometer. In addition, the chemical wear characteristics are investigated by using energy dispersive x-ray spectroscopy (EDS). Moreover, friction coefficient measurements under different materials of pin specimens are conducted for the tribological investigations. In order to verify the effect of starch phosphate particles in ER fluid, the wear test results with ER fluid are compared with test results with only silicone oil. The results clearly present that the phosphorated starch based ER fluid shows the stabilized wear as well as friction characteristics after run-in operations, but the wear rate under ER fluid is increased.

함수계와 비수계 ER유체의 온도-점도 특성 (Temperature-Viscosity Characteristics of Hydrous and Anhydrous Electro-Rheological Fluids)

  • 이진우;장성철;염만오;김도태;박재범
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 춘계학술대회 논문집
    • /
    • pp.451-456
    • /
    • 2002
  • This paper describes the properties of Temperature-Viscosity characteristics of hydrous and anhydrous ER fluids containing starch and titanium particle in silicone oil. ER effects arise from electrostatic forces between the starch particles and titanium particles dispersed in the electrically insulating silicone oil induced when electric field is applied. ER fluids under electric field have been found to provide resonable estimates of ER fluid viscosity variation characteristics. Yield shear stress of the ER fluids were measured on the couette cell type rheometer as a function of electric fields. The outer cup is connected to positive electrode(+) and bob becomes ground(-). The electric field is applied by high voltage DC power supply. In this experiment shear rates were increased from 0 to 200/equation omitted/ in 2 minutes.

  • PDF

상변화 구동 방식 마이크로 펌프의 제작 및 시험 (The Fabrication and Test of a Phase-change Type Micropump)

  • 심우영;이상우;양상식
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권6호
    • /
    • pp.360-366
    • /
    • 2000
  • This paper presents the fabrication and test of a micropump consisting of a pair of Al flap valves and a phase-change type actuator. The actuator is composed of a heater, a silicone rubber diaphragm and a working fluid chamber. The diaphragm is actuated by the vaporization and the condensation of the working fluid. The micropump is fabricated by the anisotropic etching, the boron diffusion and the metal evaporation. The forward and the backward flow characteristics of the flap valves illustrate the appropriateness as a check valve. Also, the flow rate of the micropump is measured. When the square wave input voltage of 8 V, 70% duty ratio and 2 Hz is applied to the heater, the maximum flow rate of the micropump is $97\muell/min$ for zero pressure difference.

  • PDF

Electrorheology of the Suspension Based on Chitosan Adipate as a New Anhydrous ER Fluid

  • Choi, Ung-Su;Ko, Young-Gun
    • KSTLE International Journal
    • /
    • 제2권2호
    • /
    • pp.142-145
    • /
    • 2001
  • The electrorheology of the chitosan adipnate suspension in silicone oil was investigated. Chitosan adipnate suspension showed a typical ER response (Bingham flow behavior) upon application of an electric field. The shear stress for the chitosan adipnate suspension exhibited a linear dependence on the volume fraction of particles and an electric field power of 1.88. The experimental results for the chitosan adipnate suspension correlated with the conduction models and this suspension was found to be an anhydrous ER fluid.

  • PDF

Synthesis and Electrorheological Effect of the Suspensions Composed of Nano Sized Hollow Polyaniline Derivatives

  • Choi Ung-Su
    • KSTLE International Journal
    • /
    • 제7권1호
    • /
    • pp.18-21
    • /
    • 2006
  • The electrorheology of hollow PANI derivative suspensions in silicone oil was investigated by varying the electric fields and shear rates, respectively. The hollow PANI derivative susepnsions showed a typical electrorheological (ER) response caused by the polarizability of an amide polar group and shear yield stress due to the formation of chains upon application of an electric field. The shear stress for the hollow PANI succinate suspension exhibited an electric field power of 0.67. On the basis of the experimental results, the newly synthesized hollow PANI derivative suspensions were found to be an anhydrous ER fluid.

Electrorheology of HMDA Coupled Chitosan Succinate Suspension as an Anhydrous ER Fluid

  • Kong, Seong-Wook;Kim, Seung-Wook;Lee, Sang-Soon;Choi, Ung-Su
    • KSTLE International Journal
    • /
    • 제9권1_2호
    • /
    • pp.7-9
    • /
    • 2008
  • The electrorheology of the HMDA coupled chitosan succinate suspension in silicone oil was investigated. HMDA coupled chitosan succinate suspension showed a typical ER response upon application of an electric field. The shear stress for the HMDA coupled chitosan succinate suspension exhibited an electric field power of 2.0. The experimental results for the HMDA coupled chitosan succinate suspension was found to be an anhydrous ER fluid.

ER유체를 작동유체로 하는 클러치의 제작 및 성능 실험 (Design and Performance Test of the ER Fluid Clutch)

  • 장성철;박창수;이종두
    • 한국기계가공학회지
    • /
    • 제3권1호
    • /
    • pp.84-89
    • /
    • 2004
  • This study is a basic one for application of ER Fluid to fluid power systems. By mixing silicone oil with zeolite particles, four kinds of ER fluids were made, in which the weight ratio of zeolite particles are different. We examined how the Yield shear stress and Bingham characteristics of the ER fluids are effected by varying electric field intensity. We designed and constructed a disk type power transmission clutch in which ER fluid fills and this ER fluid transmits the power of drive shaft to the driven shaft. With this equipment, the revolution transmission ratio from the chive shaft to the driven shaft by varying electric field density of the ER fluid was examined.

  • PDF

자기점성유체를 이용한 가변감쇠 마운트의 모델화 (A Modeling of a Variable-damping Mount Using Magneto-Rheological Fluid)

  • 안영공;양보석;삼하신
    • 소음진동
    • /
    • 제11권1호
    • /
    • pp.141-146
    • /
    • 2001
  • This paper deals with an application of Magneto-Rheological (MR) fluid to a small size mount for precision equipment of automobiles. MR fluid is known as a class of functional fluids with controllable apparent viscosity of fluid by the applied magnetic field strength. A typical MR fluid is a suspension where pure iron particles of 1-20 (m in diameter are dispersed in a liquid such as mineral oil or silicone oil, at the concentration of 20 - 40 vol%. Electro magnetic coil is installed at the bottom of a variable-damping mount filled with MR fluid, and performance of the mount was investigated experimentally. Furthermore, the Properties of the MR Mount on experimental study were explained analytically by mechanical model of the MR mount.

  • PDF