• 제목/요약/키워드: Silicone fluid

검색결과 106건 처리시간 0.023초

실리콘 오일을 유방에 주입한 후에 발생한 지방성 폐렴 1예 (A Case of Lipoid Pneumonia Associated with Silicon Oil Injection into Breast)

  • 최재현;김미경;박재근;박용근;최강현;이기만;안진영
    • Tuberculosis and Respiratory Diseases
    • /
    • 제69권4호
    • /
    • pp.288-292
    • /
    • 2010
  • Exogenous lipoid pneumonia occurs rarely in healthy people. In most cases, exogenous lipoid pneumonia is usually caused by aspiration of mineral, vegetable, or animal oil. We report the case of 42-year-old woman, who have experienced lipoid pneumonia after silicon injection into her breast for cosmetic purposes. The patient experienced fever, dyspnea, sputum, and hemoptysis after silicon injection into her breast. Chest computed tomography demonstrated non- segmental distribution of bilateral consolidation in both lung fields. A transbronchial lung biopsy specimen shows foamy microphages in alveolar spaces. Papanicolaous staining of bronchoalveolar lavage fluid showed abundant foamy marcrophages and many neutrophils. With these results, we confirmed lipoid pneumonia was associated with silicon oil injection into breast.

호흡기 내 주기적 공기유동에 대한 PIV 계측 (The PIV measurements on the respiratory gas flow in human airway)

  • 김성균;정성규
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2005년도 추계학술대회 논문집
    • /
    • pp.93-98
    • /
    • 2005
  • CT 스캔 데이터를 이용하여 호흡기의 컴퓨터 모델을 얻고, RP 를 이용하여 고형 모형으로 정교한 호흡기 유로 모형을 제작하였고, 호흡을 정확하게 모사하는 펌프를 만들었다. 사람의 호흡에 관한 생리적 테이터를 이용하여 캠을 제작하고 대형 피스톤 펌프를 만들어 사람의 호흡을 정확하게 모사하였다. 이를 이용하여 생리적 주기를 갖는 호흡기 내 유동에 대항 PIV 결과를 획득하였다. 최초로 정확한 기하학적 형상 및 입구와 출구 조건 하에서 인후부와 기관 내의 공기 유동장의 테이터베이스를 확보하였으므로, 향후 기존의 단순화된 모델을 이용한 실험적 수치해석적 결과들을 검정하는데 활용될 것이며 호흡기 질환의 진단과 치료에 기여할 수 있는 생리학적 병리학적 데이터를 제공할 수 있으리라 생각된다. 또한 공해 물질, 유독 물질, 흡입 약품 등의 호흡기 내 흡착 현상 규명 등에도 활용될 수 있을 것으로 보인다.

  • PDF

Surgical Experience of Transsphenoidal-Supradiaphragmatic Intradural Approach to Presellar and Suprasellar Lesions

  • Park, Min-Woo;Kim, Jae-Min;Kim, Jae-Hoon;Bak, Koang-Hum;Kim, Choong-Hyun;Jeong, Jin-Hyeok
    • Journal of Korean Neurosurgical Society
    • /
    • 제39권5호
    • /
    • pp.329-334
    • /
    • 2006
  • Objective : In selected cases, the transsphenoidal approach[TSA] can be extended anteriorly to the tuberculum sellae, chiasmatic sulcus, and planum sphenoidale to obtain direct exposure of the suprasellar cisterns and its contents. We applied this modification of the TSA to various lesions of the presellar and suprasellar areas. We evaluate our clinical experience of this technique and review the related literature. Methods : From 1999 to 2004, we used the transsphenoidal supradiaphragmatic intradural approachs[TSIAs] in 9 patients who had various lesions at the pre- and suprasellar regions. Concomitant presellar extension of the bone window was performed with the sublabial or transnasal transseptal transphenoidal techniques. After removal of the lesions, sellar or anterior cranial floor was repaired with silicone plate substitute. Results : The TSIAs have been applied in the following cases : four tuberculum sellae meningiomas, two craniopharyngiomas, two Rathke's cleft cysts, and one non-functioning macroadenoma. The complications were one case of visual acuity decrease and one cerebrospinal fluid rhinorrhea. Conclusion : The TSIA is easily applicable through a minor modification of the standard TSA. It is suitable for removing lesions located in the presellar and suprasellar area adjacent to the pituitary stalk with minimal brain manipulation and decreased morbidity.

비강내 주기유동장의 실험적 해석에 관한 연구 (The experimental research on periodic airflow in human nasal cavity)

  • 김성균;손영락;신석재
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1687-1692
    • /
    • 2004
  • CT 사진을 이용하여 살아있는 사람의 비강 형상을 얻고 RP 를 이용하여 모형을 만들고 이 모형 으로 정교한 비강 유로 모형을 제작하였고, 호흡을 정확하게 모사하는 펌프를 만들었다. 사람의 호흡 데이터를 이용하여 캠을 제작하고 대형 피스 톤 펌프를 만들어 사람의 호흡을 정확 하게 모사 하였다. 이를 이용하여 생리적 주기를 갖는 비강 내 유동에 대한 결과를 획득하고 기존의 일정유량 하의 실험결과와 비교 분석하였다.

  • PDF

SiCl4 누출 시 수막설비의 방재효과에 대한 수치 해석 연구 (A Numerical Study on the Mitigation Effect of Water Curtain for SiCl4 Toxic Gas Release)

  • 류태인;이은미;김승하;강성미;신창현;조승범
    • 한국안전학회지
    • /
    • 제38권3호
    • /
    • pp.43-50
    • /
    • 2023
  • Silicone tetrachloride (SiCl4) leak accidents cause enormous human and environmental damage because it is highly toxic. Some handling facilities use water curtains to reduce the impact range of SiCl4. Although the water curtain is known as one of the most efficient technologies for post-release mitigation, its effect on reducing SiCl4 concentration needs to be investigated scientifically and quantitatively. In this study, three-dimensional computational fluid dynamics (CFD) was used to investigate the physical and chemical effects of water curtains as a release-mitigation system for SiCl4. SiCl4 is released and dispersed five seconds prior to the operation of the water curtain. Once the water curtain works, the SiCl4 reacts chemically with the water and its concentration decreases rapidly; it reaches an emergency response planning guidelines level 2 (ERPG-2) of 5 parts per million (ppm) at about 570 m. We observed, however, that the physical effect of water curtains on reducing SiCl4 concentration is insignificant when the chemical effect is eliminated. These results are crucial since they can be a scientific and quantitative basis for the 'technical guidelines for estimating the accident affected range'. In order to protect the public from chemical accidents, more toxic gas mitigation technologies need to be developed.

Drop formation of Carbopol dispersions displaying yield stress, shear thinning and elastic properties in a flow-focusing microfluidic channel

  • Hong, Joung-Sook;Cooper-White, Justin
    • Korea-Australia Rheology Journal
    • /
    • 제21권4호
    • /
    • pp.269-280
    • /
    • 2009
  • The drop formation dynamics of a shear thinning, elastic, yield stress ($\tau_o$) fluid (Carbopol 980 (poly(acrylic acid)) dispersions) in silicone oil has been investigated in a flow-focusing microfluidic channel. The rheological character of each solution investigated varied from Netwonian-like through to highly non-Newtonian and was varied by changing the degree of neutralization along the poly (acrylic acid) backbone. We have observed that the drop size of these non-Newtonian fluids (regardless of the degree of neutralisation) showed bimodal behaviour. At first we observed increases in drop size with increasing viscosity ratio (viscosity ratio=viscosity of dispersed phase (DP)/viscosity of continuous phase (CP)) at low flowrates of the continuous phases, and thereafter, decreasing drop sizes as the flow rate of the CP increases past a critical value. Only at the onset of pinching and during the high extensional deformation during pinch-off of a drop are any differences in the non-Newtonian characteristics of these fluids, that is extents of shear thinning, elasticity and yield stress ($\tau_o$), apparent. Changes in these break-off dynamics resulted in the observed differences in the number and size distribution of secondary drops during pinch-off for both fluid classes, Newtonian-like and non-Newtonian fluids. In the case of the Newtonian-like drops, a secondary drop was generated by the onset of necking and breakup at both ends of the filament, akin to end-pinching behavior. This pinch-off behavior was observed to be unaffected by changes in viscosity ratio, over the range explored. Meanwhile, in the case of the non-Newtonian solutions, discrete differences in behaviour were observed, believed to be attributable to each of the non-Newtonian properties of shear thinning, elasticity and yield stress. The presence of a yield stress ($\tau_o$), when coupled with slow flow rates or low viscosities of the CP, reduced the drop size compared to the Newtonian-like Carbopol dispersions of much lower viscosity. The presence of shear thinning resulted in a rapid necking event post onset, a decrease in primary droplet size and, in some cases, an increase in the rate of drop production. The presence of elasticity during the extensional flow imposed by the necking event allowed for the extended maintenance of the filament, as observed previously for dilute solutions of linear polymers during drop break-up.