• 제목/요약/키워드: Silicone cable

검색결과 41건 처리시간 0.027초

지중 배전케이블의 최적 교체기준 수립을 위한 열화진단 및 특성분석 (Aging Diagnosis and Characteristic Analysis of Distribution ,Power Cables I to Prepare Optimal Replacement Criterion)

  • 김주용;송일근;정익중;한명관;심유종;문재덕
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권5호
    • /
    • pp.258-263
    • /
    • 2004
  • The purpose of this experiment is to modify diagnosis criterion of isothermal relaxation current(IRC) measurement equipment which is using for distribution cable diagnosis. We're using this system for several years in the field instead of DC leakage current measurement and lots of cables were replaced. But we have to investigate on the reliability of this equipment for our cables because we didn't carried out condition assessment of extracted cables after field diagnosis by this equipment. It is important thing for cable maintenance. If the replacement criterion is improper we can not prevent failures or will waste budget on account of replacement of the sound cables. In this paper we selected field installed cables and injected silicone fluid to the cables for insulation rehabilitation. In order to prove reliability of the diagnosis equipment we compared diagnosis results and AC breakdown strength according to operating time after silicone treatment. This is the results of the field test for 1 year.

고분자 애자의 시멘트 분진에 의한 특성 변화 연구 (Properties of composite insulators stuck by cement powder)

  • 이상진;김동욱;최명규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1602-1604
    • /
    • 2000
  • When insulators are operated near cement factories, some amount of cement powder may be stuck on the surface of insulators and decreases their electrical performances. Three kinds of insulators, such as, silicone EPDM and porcelain insulators, are tested in this paper. Testing Voltage of 25kV is applied to the samples, and surface leakage current is measured for 6 months after cement solvent of 10 vol% was stuck on the surface of each insulator in the laboratory. Insulation layers are cut from 3 and 6 month-aged insulators and tested for ac breakdown, impulse breakdown, contact angle. After aging, electrical properties are unchanged in silicone and EPDM insulators but show some changes in porcelain insulators.

  • PDF

옥외용 실리콘 고무재료의 가교도에 따른 내트랙킹 특성 (THE TRACKING CHARACTERISTICS BY THE DIFFERENT CROSSLINKED DENSITY OF SILICONE RUBBER MATERIAL USED FOR OUTDOOR INSULATION)

  • 김동욱;이창영;홍진영;백주흥;이상진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1058-1060
    • /
    • 1995
  • In this paper, we studied the tracking characteristics of silicone rubbers that differed in the degree of crosslinking. As the tracking method, we adopted ASTM D 2303 and Merry-Go-Round(MGR) test method. It was found that the higher the degree of crosslinking, the better tracking characteristics. In these two test methods, specimens showed similar tendency of performance variation according to the degree of crosslinking. However the degradation phenomena were very different. As for MGR method, only the color of specimens' surface changed without any erosion or tracking path on them. On the contrary, the specimens subjected to ASTM D 2303 test method showed severe erosion.

  • PDF

경계요소법을 이용한 전력케이블 접속부의 전계해석 (Electric Field Analysis of Power Cable Joint Point using Boundary Element Method)

  • 조경순
    • 한국컴퓨터산업학회논문지
    • /
    • 제4권4호
    • /
    • pp.579-588
    • /
    • 2003
  • 지중전선로에 있어서 케이블을 연결하는 중간 접속재에 발생하는 전계 집중, 각종 불순물의 침투 및 케이블 절연층의 손상은 궁극적으로 열화 및 절연파괴를 야기하게 되어 케이블의 수명을 단축시키고 있다. 본 연구에서는 경계요소법을 이용하여 초고압 케이블 절연재료로 널리 사용되고 있는 가교폴리에틸렌과 접속재 키트의 절연층으로 사용되고 있는 EPDM의 전계분포를 시뮬레이션 하였다. 시료는 두께 1[mm]로 3장을 중첩한 것으로 모델링하여 컴퓨터 시뮬레이션을 하였다. 전계해석 결과 보이드 내부의 defect는 silicone oil에 의해 전계집중을 약화시킴을 확인하였고, XLPB보다 EPDM의 전계분포가 낮게 유지됨을 확인하였다.

  • PDF

염무-열 반복 열화에 따른 실리콘 고무의 표면열화특성변화 (The change of surface degradation properties of silicone rubber for salt fog)

  • 오태승;이청;박수길;류부형
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.886-889
    • /
    • 2001
  • Silicone rubber is being used for the housing material of outdoor high voltage insulators such as composite insulator, bushing, surge arrestor and cable terminator because of good tracking and erosion resistance, good hydrophobicity and recovery of hydrophobicity and chemical stability. But, the leakge current occurs on surface of the composite polymeric insulation materials when the insulator is used for a long time with severe contaminative condition and it can lead the contamination flashover. So the leakage current is important to estimate the condition of the silicone rubber surface. In this paper, aging characteristics of silicone rubber used for outdoor insulation have been hydrophobicity of silicone rubber in salt fog chamber with average leakage current monitoring for observing the transformation of surface degradation properties of silicone rubber with different ATH(alumina trihydrate, A1$_2$O$_3$$.$3H$_2$O) filler contents. The experimental results show that a higher peak leakage current and to raise a long time for tracking with increasing amount of ATH by the salt fog and heat recycle ageing.

  • PDF

Al 비율에 실리콘 고무의 정전기 대전 특성 (Electrostatic Electrification Properties of Silicone Rubber due to Al Ratios)

  • 이성일
    • 한국전기전자재료학회논문지
    • /
    • 제27권8호
    • /
    • pp.522-527
    • /
    • 2014
  • In this study, using the silicone rubber sample of $4cm{\times}4cm{\times}0.1cm$ for low voltage cable, the electrostatic electrification properties of three samples that the conductive Al of 0%, 25%, and 50% is attached to the surface of sample was measured. The following conclusion was obtained through this experiment. 1) In case of the sample which has the Al area of 50%, the higher the humidity to 90% in the temperature of $10^{\circ}C$, the electrostatic electrification voltage was reduced about 0.25 kV to 0.02 kV, and it confirmed that the electrostatic electrification voltage was in constant about 0.02 kV in the temperature over $20^{\circ}C$. 2) Increasing the Al area of samples of 0%, 25%, and 50% in temperature of $10^{\circ}C$, it confirmed that the electrostatic electrification voltage was reduced by about 2.67 kV, 2.02 k, 0.21 kV. 3) This study shows that the conductor, followed by temperature and humidity affects the electrostatic electrification voltage.

초고압 케이블 중간 접속함용 실리콘 고무의 특성 고찰 (Characteristics of Silicone Rubber for EHV Cable Accessories)

  • 고의곤;신두성;지응서;윤승훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1652-1654
    • /
    • 2004
  • 초고압 지중 케이블을 전기적, 기계적으로 연결하는 역할을 하는 중간 접속함은 미가교 폴리에틸렌을 사용하여 현장에서 가교시키는 TMJ(tape molded Joint), 에폭시와 EPDM고무의 복합 절연구조를 가지고 있는 PJ(Prefabricated Joint), 그리고 EPDM또는 실리콘 고무를 단독으로 사용하는 PMJ(Premolded Joint)로 대표된다. 그러나 TMJ는 현장에서 가교하는 방식으로 조립 후 품질을 파악하기가 쉽지 않으며 PJ는 공장에서 미리 성형한 제품을 현장에서 조립만 하면 되는 구조이나 그 부품의 수가 많고, 이종 계면을 가지고 있는 복합절연구조를 가지고 있어 최근에는 부품의 수도 적고 조립이 간편하며 이종 계변의 수를 최소화하여 전기적 안정성을 높인 조립형 접속함인 PMJ를 선호하는 경향을 보이고 있다. 본 논문에서는 PMJ용으로 사용되는 실리콘 고무의 절연과 반도전 계면에서의 접착력과 전기적 파괴 특성간의 상관 관계를 규명하였고 또한 실리콘 고무의 상온 및 고온에서의 AC 및 Impulse 전압의 특성 변화와 Impulse 전압의 극성효과에 대해 규명하였다.

  • PDF

초고압 접속재용 반도전-절연체 액상실리콘 계면의 접착거동 (Adhesion Behaviors of Semiconductive-Insulation Interfaced Liquid Silicone Rubber for EHV Cable Accessory)

  • 윤승훈;김현석;김지환;이정희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.123-127
    • /
    • 2003
  • 액상실리콘으로 이루어진 초고압전력케이블용 프리몰드 접속재의 반도전-절연체 계면접합체를 다양한 제조조건과 조합별로 제조하여 계면접착력에 대한 영향을 검토하였다. 후가교적용 시 계면접착력이 강화되며 grade조합에 따른 특성차이가 존재하였다. 하지만 고온 장시간의 후가교 조건에서는 계면간의 화학적 결합력의 저하로 인해 오히려 접착력이 낮아지기도 하였다. 절연 RTV와의 계면접착성은 S-1재료가, 절연 LSR의 경우에는 S-3 재료가 가장 우수하였으며 도전안정성 측면에서도 S-3 재료가 상대적으로 유리하였다. 매입형 전극체를 제조하여 절연파괴거동을 연구한 결과 계면접착성과의 직접적인 상관관계는 크지 않음을 알 수 있었다.

  • PDF

케이블 접속재료의 전계분포 시뮬레이션 (Electric Field Distribution Simulation of the Cable Joint Materials)

  • 김형주;변두균;신종열;이덕진;이충호;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.601-604
    • /
    • 2001
  • The insulation materials of cables used for underground power transmission requires a higher insulating capability. and the most popular method to examine the cable is partial discharge test due to applying variation voltage. In the thesis. air void. silicone oil. of which may possibly exist real cables. are simulated by Electra 2D program. Also the relations between calculated field strength and the void defect type in the cable joint materails. In the modeling. electic field inner to the cable joint material composed by XLPE and EPDM is modeling simulated. We obtained the electric field distribution in void due to two conditions.

  • PDF