• 제목/요약/키워드: Silicon photomultiplier

검색결과 39건 처리시간 0.023초

Application of Hydrogenated Amorphous Silicon(a-Si : H) Radiation Detectors in Nuclear Medicine

  • Lee, Hyoung-Koo;Mendez, Victor-Perez;Shinn, Kyung-Sub
    • 한국의학물리학회지:의학물리
    • /
    • 제6권1호
    • /
    • pp.65-77
    • /
    • 1995
  • A new gamma camera using a-Si : H photodetectors has been designed for the imaging of heart and other small organs. In this new design the photomultiplier tubes and the position sensing circuitry are replaced by 2-D array of a-Si : H p-i-n pixel photode tectors and readout circuitry which are built on a substrate. Without the photomultiplier tubes this camera is light weight, hence can be made portable. To predict the characteristics and the performance of this new gamma camera we did Monte Carlo simulations. In the simulations 128${\times}$128 imaging array of various pixel sixes were used. $\^$99m/Tc(140keV)and $\^$201/Tl(70keV) were used as radiation sources. From the simulations we could obtain the resolution of the camera and ther overall system, and the blurring effects due to scattering in the phantom. Using the Wiener filter for image processing, restoration of the blurred image could be achieved. Simulation results of a-Si : H based gamma camera were compared with those of a conwentional gamma camera.

  • PDF

가정용 식품 방사능 모니터링 센서 개발 및 유용성 평가 (Development of a Foods Radioactivity Monitoring Sensor for Household and Evaluation of its Effectiveness)

  • 박혜민;김정호;이운장;김도형;민수정;주관식
    • 센서학회지
    • /
    • 제26권6호
    • /
    • pp.427-431
    • /
    • 2017
  • In this study, a foods radioactivity monitoring sensor was developed as a part of basic research for household radioactivity monitoring, and its performance was evaluated using a calibration source. The prototype of the sensor was based on a CsI:Tl scintillator using a crystal light guide and Si photomultiplier. The light guide was introduced to improve gamma-ray detection efficiency. For quantitative evaluation, tests were conducted using $^{134}Cs$ liquid source. In the performance evaluation, It was confirmed that analysis of $^{134}Cs$: 100 Bq/L(kg) was possible. Thus, result of this study is expected to contribute to research in the development of the household foods radioactivity monitoring system.

Improved measurement uncertainty of photon detection efficiency for single pixel Silicon photomultiplier

  • 양슬기;이혜영;전진아;김석환;이직;박일흥
    • 천문학회보
    • /
    • 제37권2호
    • /
    • pp.210.1-210.1
    • /
    • 2012
  • We report technique used for improved measurement uncertainties for Photon detection efficiency(PDE) of $1mm^2$ single pixel SiPM. It consists of 470nm LED light source, two 2-inch integrating sphere and two NIST calibrated silicon photodiodes that have ${\pm}2.4%$ calibration error. With raytracing simulation of our experimental setup, we predict number of photon into SiPM and measurement uncertainty. For MPPC, Hamamatsu suggested PDE(1600 micro pixel) including crosstalk and afterpulse is 23.5% at 470 nm. By using new low calibration error photodiode and raytracing simulation, our simulation result has ${\pm}3%$ measurement uncertainty. The technical detail of measurement, simulation are presented with the results and implication.

  • PDF

Simulation of a neutron imaging detector prototype based on SiPM array readout

  • Mengjiao Tang;Lianjun Zhang;Bin Tang;Gaokui He;Chang Huang;Jiangbin Zhao;Yang Liu
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3133-3139
    • /
    • 2023
  • Neutron imaging technology as a means of non-destructive detection of materials is complementary to X-ray imaging. Silicon photomultiplier (SiPM), a new type of optical readout device, has overcome some shortcomings of traditional photomultiplier tube (PMT), such as high-power consumption, large volume, high price, uneven gain response, and inability to work in strong magnetic fields. Its application in the field of neutron detection will be an irresistible general trend. In this paper, a thermal neutron imaging detector based on 6LiF/ZnS scintillation screen and SiPM array readout was developed. The design of the detector geometry was optimized by geant4 Monte Carlo simulation software. The optimized detector was evaluated with a step wedge sample. The results show that the detector prototype with a 48 mm × 48 mm sensitive area can achieve about 38% detection efficiency and 0.26 mm position resolution when using a 300 ㎛ thick 6LiF/ZnS scintillation screen and a 2 mm thick Bk7 optical guide coupled with SiPM array, and has good neutron imaging capability. It provides effective data support for developing high-performance imaging detectors applied to the China Spallation Neutron Source (CSNS).

Beta particle energy spectra shift due to self-attenuation effects in environmental sources

  • Alton, Thomas Theakston;Monk, Stephen David;Cheneler, David
    • Nuclear Engineering and Technology
    • /
    • 제49권7호
    • /
    • pp.1483-1488
    • /
    • 2017
  • In order to predict and control the environmental and health impacts of ionizing radiation in environmental sources such as groundwater, it is necessary to identify the radionuclides present. Beta-emitting radionuclides are frequently identified by measuring their characteristic energy spectra. The present work shows that self-attenuation effects from volume sources result in a geometry-dependent shift in the characteristic spectra, which needs to be taken into account in order to correctly identify the radionuclides present. These effects are shown to be compounded due to the subsequent shift in the photon spectra produced by the detector, in this case an inorganic solid scintillator ($CaF_2:Eu$) monitored using a silicon photomultiplier. Using tritiated water as an environmentally relevant, and notoriously difficult to monitor case study, analytical predictions for the shift in the energy spectra as a function of depth of source have been derived. These predictions have been validated using Geant4 simulations and experimental results measured using bespoke instrumentation.

PLD증착 변수에 따른 II-VI족 화합물 ZnO 반도체 박막의 발광 특성 연구 (Correlation Between Deposition Parameters and Photoluminescence of ZnO Semiconducting Thin Films by Pulsed laser Deposition)

  • 배상혁;윤일구;서대식;명재민;이상렬
    • 한국전기전자재료학회논문지
    • /
    • 제14권3호
    • /
    • pp.246-250
    • /
    • 2001
  • ZnO thin films for light emission device have been deposited on sapphire and silicon substrates by pulsed laser deposition technique(PLD). A Nd:YAG laser was used with the wavelength of355 nm. In order to investigate the emission properties of ZnO thin films, Pl measurements with an Ar ion laser a light source using an excitation wavelength of 351 nm and a power of 100 mW are used. All spectra were taken at room temperature by using a grating spectrometer and a photomultiplier detector. ZnO exhibited Pl bands centers around 390, 510 and 640 nm, labeled near ultra-violet(UV), green and orange bands. Structural properties of ZnO thin films are analyzed with X-ray diffraction(XRD).

  • PDF

PLD로 증착한 ZnO 박막의 발광 특성 분석 (Emission Properties of ZnO Grown by PLD)

  • 배상혁;이상렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.422-424
    • /
    • 2000
  • ZnO thin films for light emission device have been deposited on sapphire and silicon substrates by pulsed laser deposition technique(PLD). A Nd:YAG laser was used with the wavelength of 355 nm. In order to investigate the emission properties of ZnO thin films, PL measurements with an Ar ion laser as a light source using an excitation wavelength of 351 nm and a power of 100 mW are used. All spectra were taken at room temperature by using a grating spectrometer and a photomultiplier detector. ZnO exhibited PL bands centered around 390, 510 and 640 nm, labeled near ultra-violet (UV), green and orange bands. Structural properties of ZnO thin films are analized with X-ray diffraction (XRD).

  • PDF

Development of hand-held coded-aperture gamma ray imaging system based on GAGG(Ce) scintillator coupled with SiPM array

  • Jeong, Manhee;Hammig, Mark
    • Nuclear Engineering and Technology
    • /
    • 제52권11호
    • /
    • pp.2572-2580
    • /
    • 2020
  • Emerging gamma ray detection applications that utilize neutron-based interrogation result in the prompt emission of high-energy (>2 MeV) gamma-rays. Rapid imaging is enabled by scintillators that possess high density, high atomic number, and excellent energy resolution. In this paper, we evaluate the bright (50,000 photons/MeV) oxide scintillator, cerium-doped Gd2Al2Ga3O12 (GAGG(Ce)). A silicon photomultiplier (SiPM) array is coupled to a GAGG(Ce) scintillator array (12 × 12 pixels) and integrated into a coded-aperture based gamma-ray imaging system. A resistor-based symmetric charge division circuit was used reduce the multiplicity of the analog outputs from 144 to 4. The developed system exhibits 9.1%, 8.3%, and 8.0% FWHM energy resolutions at 511 keV, 662 keV, and 1173.2 keV, respectively. In addition, a pixel-identification resolution of 602 ㎛ FWHM was obtained from the GAGG(Ce) scintillator array.

펄스 레이저 증착법으로 제작한 ZnO 박막의 발광 특성 (Light emission properties of ZnO thin films grown by pulsed laser deposition)

  • 배상혁;이상렬
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.539-542
    • /
    • 2000
  • ZnO thin films for light emission device have been deposited on sapphire and silicon substrates by pulsed laser deposition technique(PLD). A Nd:YAG laser was used with the wavelength of 355 nm. In order to investigate the emission properties of ZnO thin films, PL measurements with an Ar ion laser as a light source using an excitation wavelength of 351 nm and a power of 100 mW are used. All spectra were taken at room temperature by using a grating spectrometer and a photomultiplier detector. ZnO exhibited PL bands centered around 390, 510 and 640 nm, labeled near ultra-violet (UV), green and orange bands. Structural properties of ZnO thin films are analized with X-ray diffraction (XRD).

  • PDF

수중 방사선 감시체계 구축을 위한 실시간 방사선 준위 모니터링 센서 개발 (Development of a Real-time Radiation Level Monitoring Sensor for Building an Underwater Radiation Monitoring System)

  • 박혜민;주관식
    • 센서학회지
    • /
    • 제24권2호
    • /
    • pp.96-100
    • /
    • 2015
  • In the present study, we developed a real-time radiation-monitoring sensor for an underwater radiation-monitoring system and evaluated its effectiveness using reference radiation sources. The monitoring sensor was designed and miniaturized using a silicon photomultiplier (SiPM) and a cerium-doped-gadolinium-aluminum-gallium-garnet (Ce:GAGG) scintillator, and an underwater wireless monitoring system was implemented by employing a remote Bluetooth communication module. An acrylic water tank and reference radiation sources ($^{137}Cs$, $^{90}Sr$) were used to evaluate the effectiveness of the monitoring sensor. The underwater monitoring sensor's detection response and efficiency for gamma rays and beta particles as well as the linearity of the response according to the gammaray intensity were verified through an evaluation. This evaluation is expected to contribute to the development of base technology for an underwater radiation-monitoring system.