• 제목/요약/키워드: Silicon mold

검색결과 116건 처리시간 0.028초

Nano Pillar Array 사출성형을 이용한 DNA 분리 칩 개발 (Development of the DNA Sequencing Chip with Nano Pillar Array using Injection Molding)

  • 김성곤;최두선;유영은;제태진;김태훈;황경현
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1206-1209
    • /
    • 2005
  • In recent, injection molding process for features in sub-micron scale is under active development as patterning nano-scale features, which can provide the master or stamp for molding, and becomes available around the world. Injection molding has been one of the most efficient processes for mass production of the plastic product, and this process is already applied to nano-technology products successfully such as optical storage media like DVD or BD which is a large area plastic thin substrate with nano-scale features on its surface. Bio chip for like DNA sequencing may be another application of this plastic substrate. The DNA can be sequenced using order of 100 nm pore structure when making the DNA flow through the pore structure. Agarose gel and silicon based chip have been used to sequence the DNA, but injection molded plastic chip may have benefit in terms of cost. This plastic DNA sequencing chip has plenty of pillars in order of 100 nm in diameter on the substrate. When the usual features in case of DVD or BD have very low aspect ratio, even less than 0.5, but the DNA chip will have relatively high aspect ratio of about 2. It is not easy to injection mold the large area thin substrate with sub-micron features on its surface due to the characteristics of the molding process and it becomes much more difficult when the aspect ratio of the features becomes high. We investigated the effect of the molding parameters for injection molding with high aspect ratio nano-scale features and injection molded some plastic DNA sequencing chips. We also fabricated PR masters and Ni stamps of the DNA chip to be used for molding

  • PDF

무가압 분말충전 알루미나에 이트리아를 함유한 붕규산염 유리를 침투시킨 코아 도재의 물성 (THE PHYSCIAL PORPERTIES OFY Y2O3-CONTAINING GLASS INFILTRATED ALUMINA CORE MADE BY PRESSURELESS POWDER PACKING METHOD)

  • 황승우;이근우
    • 대한치과보철학회지
    • /
    • 제35권1호
    • /
    • pp.221-243
    • /
    • 1997
  • The objective of this study was to characterize the mechanical properties of $Y_{2}O_{3}$-containing glass infiltrated ceramic core material, which was made by pressureless powder packing method. A pure alumina powder with a grain size of about $4{\mu}m$ was packed without pressure is silicon mold to form a bar shaped sample, and applied PVA solution as a binder. Samples were sinterd at $1350^{\circ}C$ for 1 hour. After cooling, $Y_{2}O_{3}$-containing glass($SiO_{2},\;Y_{2}O_{3},\;B_{2}O_{3},\;Al_{2}O_{3}$, ect) was infiltrated to the sinterd samples at $1300^{\circ}C$ for 2 hours and cooled. Six different proportions $Y_{2}O_{3}$ of were used to know the effect of the mismatch of the thermal expansion coefficient between alumina powder and glass. The samples were ground to $3{\times}3{\times}30$ mm size and polished with $1{\mu}m$ diamond paste. Flexural strength, fracture toughness, hardness and other physical properties were obtained, and the fractured surface was examined with SEM and EPMA. Ten samples of each group were tested and compared with In-Ceram(tm) core materials of same size made in dental laboratory. The results were as follows : 1. The flexural strengths of group 1 and 3 were significantly not different with that of In-Ceram, but other experimental groups were lower than In-Ceram. 2. The shrinkage rate of samples was 0.42% after first firing, and 0.45% after glass infiltration. Total shrinkage rate was 0.87%. 3. After first firing, porosity rate of experimental groups was 50%, compared with 22.25% of In-Ceram. After glass infiltration, porosity rate of experimental groups was 2%, and 1% in In-Ceram. 4. There was no statistical difference in hardness between two materials tested, but in fracture toughness, group 2 and 3 were higher than In-Ceram. 5. The thermal expansion coefficients of experimental groups were varied to $4.51-5.35{\times}10^{-6}/^{\circ}C$ according to glass composition, also the flexural strengths of samples were varied. 6. In a view of SEM, many microparticles about $0.5{\mu}m$ diameter and $4{\mu}m$ diameter were observed in In-Ceram. But in experimental group, the size of most particles was about $4{\mu}m$, and a little microparticles was observed. The results obtained in this study showed that the mismatch of the thermal expansion coefficients between alumina powder and infiltrated glass affect the flexural strength of alumin/glass composite. The $Y_{2}O_{3}$-containing glass infiltrated ceramic core made by powder packing method will takes less time and cost with sufficient flexural strength similar to all ceramic crown made with slip casting technique.

  • PDF

A SHEAR BOND STRENGTH OF RESIN CEMENT BONDED TO HUMAN UNCUT ENAMEL, CUT ENAMEL, AND DENTIN IN VITRO

  • Lee Jong-Yeop
    • 대한치과보철학회지
    • /
    • 제41권3호
    • /
    • pp.319-324
    • /
    • 2003
  • Statement of problem. Adhesives in dentistry playa major role in the success of restorative treatments. In the treatment of all ceramic restoration it is needed to find the adequate bond strength between enamel and dentin. Purpose. The purpose of this study was to evaluate shear bond strength of resin cement bonded to extracted human uncut enamel, cut enamel, and dentin in vitro. Material and methods. Ten freshly extracted anterior teeth without any previous restorative treatments were chosen. The extracted teeth were embedded in PMMA cold acrylic in the shape of a cylinder, 25 mm in diameter by 25 mm in height. The bonding system used was as follow: Uni-Etch (32% phosphoric acid), One-Step adhesive, Duolink resin cement. The specimens were acid etched and rinsed with water. Two layers of One-Step adhesive were coated with a disposable brush on the uncut enamel. VIP curing light at $500mV/cm^2$ was used to cure the adhesive. For cut enamel shear bond test, the specimen used for uncut enamel was further reduced approximately $0.3{\sim}0.5mm$ using a laminate preparation diamond bur (0.3 mm in depth). The specimens were subsequently treated with 320-grit SiC paper followed by 600-grit SiC paper and cleaned with distilled water. The bonding procedure on the cut enamel was same as uncut enamel bonding procedure. For dentin bonding test, the specimen used for cut enamel was further reduced approximately $0.5mm{\sim}1.0mm$ using a laminate preparation diamond bur (0.5 mm in depth of diamond cutting). The amount of reduction was evaluated with the silicone mold. The specimens were subsequently treated with 320-grit SiC paper followed by 600-grit silicon carbon paper and cleaned in distilled water. The bonding procedure on the dentin was same as uncut enamel bonding procedure. All samples were mounted and secured on the Ultradent shear bond test sample holder, and Ultradent restricted shear bond testing device was used with Universal Instron machine until fracture. Analysis of variance (ANOVA) test was performed comparing the result at P<0.05. Multiple comparison (Tukey) was used to compare each groups. Result. The result showed that the mean value in shear bond strength of resin cement bonded to uncut enamel, cut enamel and dentin were 27.04 Mpa, 30.25 Mpa and 26.39 Mpa with respect. Conclusion. Within the limitation of this study, the mean value of the shear bond strength of cut enamel was higher than those of uncut enamel or dentin. However there existed no statistical differences between three different human dentition substrates due to increased adhesive characteristics.

복합재 격자구조물의 점검창 형상에 따른 구조안전성 해석 (Structure Safety Analysis of Composite Lattice Structure with Inspection Window)

  • 김동건;배주찬;손조화;이상우
    • 한국추진공학회지
    • /
    • 제22권6호
    • /
    • pp.94-103
    • /
    • 2018
  • 발사체 및 유도무기 기체에 사용되는 복합재 격자구조물은 구조물에 작용하는 하중을 고려하여 최소한의 두께와 무게로 설계되는 구조물이다. 이를 위하여 실리콘 몰드에 탄소섬유를 와인딩하는 공정으로 격자구조물을 만들며, 이때 발사체 및 유도무기 기체 내부의 장비 등을 점검하기 위하여 점검창을 설치하는 것이 일반적으로 요구된다. 본 논문에서는 필라멘트 와인딩 공정으로 제작된 실린더형 격자구조물에 대하여 압축시험을 수행하고, 이 구조물에 대한 유한요소해석을 수행하여 얻은 해석 결과를 설치된 격자구조물에 대하여 유한요소해석을 수행하였다. 또한 구조물의 리브(Rib)와 노트(Knot)의 파손강도를 통해 육각형 점검창의 두께 및 위치를 변수로 선정하여 수행한 유한요소해석 결과는 다음과 같다; (1) 육각형 점검창의 안전계수가 사각형 점검창 보다 높게 계산되었으며, (2) 수직 점검창이 상단 헬리컬 리브의 중간에 위치할 때 안전계수가 높게 계산되었고, (3) 구조안전성 확보를 위하여 점검창의 두께를 증가시킬 경우 구조물의 불연속 부분에 응력집중이 발생하므로 유한요소 해석을 통해 안전계수가 가장 높은 점검창 형상을 선정해야 한다.

진동이 상아질 결합력에 미치는 영향에 관한 연구 (A STUDY OF ADDITIONAL VIBRATION EFFECT ON DENTIN BOND STRENGTH)

  • 이진;김정욱;이상훈;김종철
    • 대한소아치과학회지
    • /
    • 제29권4호
    • /
    • pp.632-640
    • /
    • 2002
  • 초음파 진동을 치의학에 처음 이용한 것은 치석 제거기였으나, 최근에는 주조금속과 레진 인레이를 접착할 때, 인산아연시멘트나 레진시멘트의 점도를 낮추는데 이용되고 있다. 이러한 초음파 진동은 재료의 흐름성을 증가시킴으로써 피막도를 낮추고, 따라서 수복물 주위의 미제누출을 감소시킬 수 있는 장점이 있다. 그러나, 복합레진의 수복에 있어서 이러한 초음파 진동의 임상적 효과에 관한 연구가 아직까지 미흡한 실정이다. 이에 저자는 초음파 진동을 상아질 결합제에 적용하여 점도를 감소시킴으로써 상아세관으로의 레진 침투 정도의 변화와 결합력에 미치는 효과를 알아보고자 하였다. 발거 후 실온의 0.1% thymol 용액에 보관된 88개의 건전한 사람의 대구치를 치관부 법랑질을 제거하고 아크릴 레진을 이용하여 직경 1-inch의 PVC 관에 매몰하였다. 각 시편의 교합면이 아크릴봉과 동일한 높이가 되도록 220-, 500-grit의 연마지로 순차적으로 연마하였고, 무작위로 추출하여 각 군당 22개씩 네 군으로 분류하였다. 1군과 2군은 Single Bond(3M-ESPE, St. Paul, USA)를 3군과 4군은 One-Step(Bisco Inc., Schaumburg, USA)을 제조사의 지시에 따라 치면을 산부식, 수세, 건조한 후 연속하여 2번을 도포하였다. 2군과 4군은 초음파 치석제거기를 이용하여 치면에 대고 10 초간 진동을 가한 후 광중합하였다. 이후 직경 2.3mm, 높이 3.5mm의 Teflon mold(Ultradent Products Inc., South Jordan, USA)를 이용하여 복합레진을 충전한 후 40초씩 두 번에 나누어 광중합하였다. 모든 시편은 24시간 동안 실온의 수도물에 보관한 후 열순환을 시행하고, 만능측정기(Instron 4465, Canton, USA)로 전단결합강도를 측정하였으며 resin tag의 양상을 비교하기 위해 각 군의 시편의 치질을 탈회시킨 후에 표면을 주사전자 현미경으로 관찰하여 다음과 같은 결과를 얻었다. 1. 초음파 진동을 가하지 않은 1군, 3군에 비해 초음파 진동을 가한 2군과 4군에서 전단결합강도가 유의하게 높게 나타났다(p<0.05). 2. Single Bond와 One-Step의 전단결합강도는 유의한 차이를 보이지 않았다(p>0.05). 3. 전자현미경 관찰에서 초음파 진동을 가한 군에서 resin tag의 길이가 길었고, lateral branch의 수도 많이 관찰되었다.

  • PDF

치과 교정용 자가중합형 Resin의 중합 온도 변화에 따른 굽힘 특성 (Flexural Properties according to Change of Polymerization Temperature of Autopolymerized Resin for Orthodontic)

  • 이규선
    • 치위생과학회지
    • /
    • 제15권3호
    • /
    • pp.259-264
    • /
    • 2015
  • 치과 교정용 자가중합형 레진의 중합 온도가 기계적 특성에 미치는 영향을 알아보기 위하여 폴리머와 모노머의 부피비는 2.5:1로 하고, 중합 온도를 $25^{\circ}C$, $40^{\circ}C$, $70^{\circ}C$의 세 group으로 나누었다. 실험을 위해 각 group 당 10개씩의 시편을 중합 시간 15분, 중합 압력 3 bar로 통일하여 제작하였다. 그 후 시편을 실험 전까지 $37^{\circ}C$의 증류수에 48시간 이상 보관한 다음, Intron (3344)을 이용하여 각 시편의 FS 및 EM을 측정하였다. 이렇게 하여 얻어진 값들은 SPSS ver. 16.0을 사용하여 일원 배치 분산 분석을 하였으며 Scheffe의 사후 검정을 실시하여 다음과 같은 결과를 얻었다. 치과 교정용 자가중합형 레진의 FS 평균값을 비교해 보았을 때 $25^{\circ}C$ group은 $71.500{\pm}5.546MPa$, $40^{\circ}C$ group은 $74.920{\pm}4.237MPa$, $70^{\circ}C$ group은 $76.880{\pm}4.304MPa$의 범위였으며, $25^{\circ}C$ group<$40^{\circ}C$ group<$70^{\circ}C$ group 순으로 차이가 있었으나 통계적으로 유의한 차이는 없었다(p=0.052). 치과 교정용 자가중합형 레진의 EM 평균값은 $25^{\circ}C$ group이 $2.164{\pm}0.073MPa$, $40^{\circ}C$ group은 $2.258{\pm}0.069MPa$, $70^{\circ}C$ group은 $2.282{\pm}0.147MPa$의 범위였으며, $25^{\circ}C$ group<$40^{\circ}C$ group<$70^{\circ}C$ group 순으로 중합 온도가 높을수록 유의한 차이를 보였다(p<0.039). 이상의 실험 결과로 미루어 볼 때 EM 값은 $25^{\circ}C$ group<$40^{\circ}C$ group<$^70{\circ}C$ group 순으로 통계적 유의성이 인정되는 수준의 상승이 있었던 반면, FS 값은 통계적 유의성은 보이고 있지 않으나 강도의 증가에 영향을 미치고 있으므로, 치과 교정 장치 제작 시 일정 수준의 중합 온도 상승은 장치의 기계적 물성을 증가시킬 것이라고 판단된다.