A STUDY OF ADDITIONAL VIBRATION EFFECT ON DENTIN BOND STRENGTH

진동이 상아질 결합력에 미치는 영향에 관한 연구

  • Lee, Jin (Department of Pediatric Dentistry and Dental Research Institute, College of Dentistry, Seoul National University) ;
  • Kim, Jung-Wook (Department of Pediatric Dentistry and Dental Research Institute, College of Dentistry, Seoul National University) ;
  • Lee, Sang-Hoon (Department of Pediatric Dentistry and Dental Research Institute, College of Dentistry, Seoul National University) ;
  • Kim, Chong-Chul (Department of Pediatric Dentistry and Dental Research Institute, College of Dentistry, Seoul National University)
  • 이진 (서울대학교 치과대학 소아치과학교실 및 치학연구소) ;
  • 김정욱 (서울대학교 치과대학 소아치과학교실 및 치학연구소) ;
  • 이상훈 (서울대학교 치과대학 소아치과학교실 및 치학연구소) ;
  • 김종철 (서울대학교 치과대학 소아치과학교실 및 치학연구소)
  • Published : 2002.11.30

Abstract

The objective of the study was to apply the vibration technique to reduce the viscosity of bonding adhesives and thereby compare the bond strength and resin penetration into dentinal tubules achieved with those gained using the conventional technique. Eighty-eight noncarious extracted human permanent molar teeth were sectioned to remove the coronal enamel and were embedded in 1-inch PVC pipe with acrylic resin. The occlusal surfaces were placed so that the tooth and the embedding medium were at the same level to form one flat surface, and the samples were subsequently polished with silicon carbide abrasive papers. The samples were randomly assigned to 4 groups(n=22). On Group 1 and 2, Single Bond(3M-ESPE, St. Paul, USA) was used, and on Group 3 and 4, One-Step(Bisco Inc., Schaumburg, USA) was used, and each was applied according to its manufacturer's instructions. For Group 2 and Group 4, vibration was applied with ultrasonic scaler for 10 seconds, and the adhesive was light-cured for 10 seconds. Resin composite was condensed on to the prepared surface in two increments using a mold kit(Ultradent Products Inc., USA) and each was light-cured for 40 seconds. After 24 hours in tap water at room temperature the specimens were thermocycled, and shear bond strengths were measured with a universal testing machine(Instron 4465, Canton, USA). To investigate infiltration patterns of the adhesive materials, the surface of specimen was examined with scanning electron microscope. The results were as follows. 1. The shear bond strengths of vibration groups(Group 2, Group 4) were significantly greater than those of the non-vibration groups(Group 1, Group 3)(p<0.05). 2. The shear bond strengths of Single Bond and One-Step were not significantly different (p>0.05). 3. The vibration groups showed greater number of resin tags in tubules and lateral branches under SEM.

초음파 진동을 치의학에 처음 이용한 것은 치석 제거기였으나, 최근에는 주조금속과 레진 인레이를 접착할 때, 인산아연시멘트나 레진시멘트의 점도를 낮추는데 이용되고 있다. 이러한 초음파 진동은 재료의 흐름성을 증가시킴으로써 피막도를 낮추고, 따라서 수복물 주위의 미제누출을 감소시킬 수 있는 장점이 있다. 그러나, 복합레진의 수복에 있어서 이러한 초음파 진동의 임상적 효과에 관한 연구가 아직까지 미흡한 실정이다. 이에 저자는 초음파 진동을 상아질 결합제에 적용하여 점도를 감소시킴으로써 상아세관으로의 레진 침투 정도의 변화와 결합력에 미치는 효과를 알아보고자 하였다. 발거 후 실온의 0.1% thymol 용액에 보관된 88개의 건전한 사람의 대구치를 치관부 법랑질을 제거하고 아크릴 레진을 이용하여 직경 1-inch의 PVC 관에 매몰하였다. 각 시편의 교합면이 아크릴봉과 동일한 높이가 되도록 220-, 500-grit의 연마지로 순차적으로 연마하였고, 무작위로 추출하여 각 군당 22개씩 네 군으로 분류하였다. 1군과 2군은 Single Bond(3M-ESPE, St. Paul, USA)를 3군과 4군은 One-Step(Bisco Inc., Schaumburg, USA)을 제조사의 지시에 따라 치면을 산부식, 수세, 건조한 후 연속하여 2번을 도포하였다. 2군과 4군은 초음파 치석제거기를 이용하여 치면에 대고 10 초간 진동을 가한 후 광중합하였다. 이후 직경 2.3mm, 높이 3.5mm의 Teflon mold(Ultradent Products Inc., South Jordan, USA)를 이용하여 복합레진을 충전한 후 40초씩 두 번에 나누어 광중합하였다. 모든 시편은 24시간 동안 실온의 수도물에 보관한 후 열순환을 시행하고, 만능측정기(Instron 4465, Canton, USA)로 전단결합강도를 측정하였으며 resin tag의 양상을 비교하기 위해 각 군의 시편의 치질을 탈회시킨 후에 표면을 주사전자 현미경으로 관찰하여 다음과 같은 결과를 얻었다. 1. 초음파 진동을 가하지 않은 1군, 3군에 비해 초음파 진동을 가한 2군과 4군에서 전단결합강도가 유의하게 높게 나타났다(p<0.05). 2. Single Bond와 One-Step의 전단결합강도는 유의한 차이를 보이지 않았다(p>0.05). 3. 전자현미경 관찰에서 초음파 진동을 가한 군에서 resin tag의 길이가 길었고, lateral branch의 수도 많이 관찰되었다.

Keywords