  • We developed a test of English silent word reading, following work by Mather, Hammill, Allen and Roberts (2004) and Bell, McCallum, Krik, Fuller, and McCane-Bowling (2007), in order to tap Hong Kong Chinese children's reading of English as a foreign language. We created one subtest of individual word reading and another of word reading contextualized within sentences; together, these tests require no more than 10 minutes for administration. In Study 1, we administered the entire test to 552 second grade Hong Kong Chinese children between the ages of 70 and 121 months old, from five different primary schools. The association between the subtests of English silent word reading and contextual reading was positively correlated (.78). In Study 2, 77 Hong Kong Chinese second graders were tested on our newly developed English silent word reading test, together with non-verbal IQ, an English word reading and a Chinese character recognition test (both read aloud). With age and non-verbal IQ statistically controlled, there was a significant correlation between English silent word reading and the more standard English word reading, read aloud, (.78); the association between English silent word reading and Chinese character recognition was also positively correlated (.49). This newly created test is a quick and reliable measure, suitable for both educators and researchers to use to identify poor readers who learn English as a foreign or second language.

Development of Silent Discharge Chamber with Al2O3 Dielectric Pellet to Improve Ozone Generation Characteristics (오존발생특성 향상을 위한 강유전성 알루미나 무성방전관의 개발)

  • Kwak, Dong-Joo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.7
    • /
    • pp.58-64
    • /
    • 2006
  • Recently deep interests have been paid on the effective generation of ozone, which has been widely used for water treatment, deodorization, color removal, and chemical processing of exhausted smoke. The silent discharge reaction has been proposed as the most effective one in the many ozone generation methods, because the silent discharge can be generated under the conditions of lower applied voltage and power consumption, compared other ones. In this paper, in order to improve the ozone generation and ozone generation efficiency, the conventional silent discharge chamber with $Al_2O_3$ dielectric layer and tubular ferroelectric bed discharge reactor packed with $Al_2O_3$ pellets were made, and the silent discharge of the reactors were studied experimentally. The ozone generation characteristics are also discussed based on the discharge characteristics, especially on the wall charge accumulation properties and power consumption. The results show that the electric charges of discharge tube with bead are around 2.5 times as large as those without bead. In the discharge chamber packed with dielectric beads, the ozone concentration and the energy yield characteristics were also improved, compared with those in the conventional silent discharge reactor.

Usefulness of Silent MRA for Evaluation of Aneurysm after Stent-Assisted Coil Embolization

  • You Na Kim;Jin Wook Choi;Yong Cheol Lim;Jihye Song;Ji Hyun Park;Woo Sang Jung
    • Korean Journal of Radiology
    • /
    • v.23 no.2
    • /
    • pp.246-255
    • /
    • 2022
  • Objective: To determine the usefulness of Silent MR angiography (MRA) for evaluating intracranial aneurysms treated with stent-assisted coil embolization. Materials and Methods: Ninety-nine patients (101 aneurysms) treated with stent-assisted coil embolization (Neuroform atlas, 71 cases; Enterprise, 17; LVIS Jr, 9; and Solitaire AB, 4 cases) underwent time-of-flight (TOF) MRA and Silent MRA in the same session using a 3T MRI system within 24 hours of embolization. Two radiologists independently interpreted both MRA images retrospectively and rated the image quality using a 5-point Likert scale. The image quality and diagnostic accuracy of the two modalities in the detection of aneurysm occlusion were further compared based on the stent design and the site of aneurysm. Results: The average image quality scores of the Silent MRA and TOF MRA were 4.38 ± 0.83 and 2.78 ± 1.04, respectively (p < 0.001), with an almost perfect interobserver agreement. Silent MRA had a significantly higher image quality score than TOF MRA at the distal internal carotid artery (n = 57, 4.25 ± 0.91 vs. 3.05 ± 1.16, p < 0.001), middle cerebral artery (n = 21, 4.57 ± 0.75 vs. 2.19 ± 0.68, p < 0.001), anterior cerebral artery (n = 13, 4.54 ± 0.66 vs. 2.46 ± 0.66, p < 0.001), and posterior circulation artery (n = 10, 4.50 ± 0.71 vs. 2.90 ± 0.74, p = 0.013). Silent MRA had superior image quality score to TOF MRA in the stented arteries when using Neuroform atlas (4.66 ± 0.53 vs. 3.21 ± 0.84, p < 0.001), Enterprise (3.29 ± 1.59 vs. 1.59 ± 0.51, p = 0.003), LVIS Jr (4.33 ± 1.89 vs. 1.89 ± 0.78, p = 0.033), and Solitaire AB stents (4.00 ± 2.25 vs. 2.25 ± 0.96, p = 0.356). The interpretation of the status of aneurysm occlusion exhibited significantly higher sensitivity with Silent MRA than with TOF MRA when using the Neuroform Atlas stent (96.4% vs. 14.3%, respectively, p < 0.001) and LVIS Jr stent (100% vs. 20%, respectively, p = 0.046). Conclusion: Silent MRA can be useful to evaluate aneurysms treated with stent-assisted coil embolization, regardless of the aneurysm location and type of stent used.

Dynamic Analysis of Timing Silent Chain System for a V-type Engine of a Vehicle

  • Feng, Zengming;Tang, Lechao;Li, Jun;Jia, Yanhui
    • Transactions of the KSME C: Technology and Education
    • /
    • v.3 no.2
    • /
    • pp.89-96
    • /
    • 2015
  • Based on multi-body dynamic software RecurDyn, this paper proposes a modified form of timing silent chain system combing with the existing problem that vibration and chain tension is too large, which is applied for complicated conditions in a V-type engine, such as high speed, variable loads. The analysis of chain drive meshing characteristics is completed. Using the multi-body dynamic soft-ware RecurDyn, the dynamics characteristics of the improved system is studied, including chain tension, transmission error, chain fluctuations, equivalent spring force in different operating conditions. The study results show that chain tension, transmission error, chain fluctuation and equivalent spring force are within the scope of permission, all of them can meet the design requirement. There-fore, the design of this system is reasonable and practicable. The research results will provide a basis for assessing timing silent chain system in a V-type engine and a theoretical reference for designing and optimizing the timing silent chain system.

Developing a Schedulable App for Switching to Silent Mode Using an Android phone (스케줄링이 가능한 무음 모드 전환 안드로이드 폰 앱 개발)

  • Jang, Jae-Young;Kim, Il-Min
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.2
    • /
    • pp.53-59
    • /
    • 2012
  • Smart phones are very convenient for communication, but you need to not to forget to change to silent mode when you go to church or cinema. Many people used to forget changing their cell phones to silent mode. In this paper, we have developed an android smart phone app. for automatic changing silent mode, which exploited smart phones' GPS and computing capability. According to the GPS location data and time, this app. will automatically change a cell phone to silent mode. We believe that this app. would provide us a lot of convenience.

A Relationship Between the EMG Silent Period and Muscle Fatigue of the Masticatory Muscle (저작근의 근전도 휴지기와 근육피로와의 관계)

  • Kim, Tae-Hoon;Yang, Deok-Jin;Kang, Byeong-Gil;Cho, Il-Jun;Lee, Jin;Kim, Sung-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.5
    • /
    • pp.247-254
    • /
    • 2001
  • Silent period(SP) is transient stops of muscle activity that are induced by mechanical or electrical stimulus and the duration of silent period is a important parameter that have been associated with symptoms of masticatory dysfunction. Muscle fatigue is induced by sustained muscular contractions. It is associated with the external manifestations as the inability to maintain a desired force output, muscular tremor, and localized pain. Muscle fatigue is a parameter that have been measured or monitored the deterioration of a performance of muscles. On the study of relationship between SP and masticatory muscle fatigue, Nagasawa suggested that SP increases up to 3 min. from the beginning of clenching when the subjects performed sustained contractions at 50% maximum clenching level. In this paper, in order to evaluate a relationship between SP and muscle fatigue, 10 SPs per 1 minute are measured at 10%, 20%, 50% maximum clenching level. We used the median frequency in order to quantify the degree of muscle fatigue. However, the results shows that the duration of silent period was not significantly affected by differing levels of muscle fatigue. Therefore, we suggest that the SP is not increased or decreased as the results of muscle fatigue, also the origin of the SP generation mechanism is discussed.

  • PDF

The Characteristics of Superposed Ozonizer using Three-Phase Voltage (3상전압을 이용한 중첩방전형 오존발생기의 특성)

  • Kim, Yeong-Hun;Chun, Byung-Joon;Song, Hyun-Jig;Youn, Young-Dae;Lee, Kwang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2259-2261
    • /
    • 1999
  • In this paper, an ozonizer, which can generate individual and superposed silent discharge, using three-phase voltage has been designed and manufactured. The ozonizer consists of 3 electrodes(Central Electrode, Internal Electrode and External Electrode) and 2 gaps(gap between Central Electrode and Internal Electrode, gap between Internal Electrode and External Electrode). Ozone is generated according to voltage supplying method to each electrode by individual silent discharge and three-phase superposed discharge. The characteristics of ozone generation were investigated with variation of discharge power and the quantity of supplied gas($O_2$). In case of individual silent discharge, the maximum values of ozone concentration, ozone generation and ozone yield were obtained between internal electrode and external electrode, and its values were 2300[ppm], 570[mg/h] and 745[g/kWh] respectively. Each maximum values was 5039[ppm], 1773[mg/h] and 851[g/kWh] respectively, when three-phase superposed silent discharge was employed. Therefore, characteristics of ozone generation with three-phase voltage are improved compared with single-phase voltage because silent discharge is generated continuously.

  • PDF

The Discharge and Ozone Generation Characteristics of Ferroelctric-Pellet Reactor for Ozone Generation (오존발생기용 강유전 펠렛 방전관의 방전 및 오존발생 특성)

  • Park, Myoung-Ha;Kwak, Dong-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2147-2149
    • /
    • 2000
  • The silent discharge is known to be one of the most effective methods for ozone generation. In this paper. in order to improve ozone concentration and energy yield, some kind of silent discharge-type reactors with different dielectric materials were prepared. Some silent discharge characteristics of these reactors were studied and discussed.

  • PDF

Silent Discharge and Ozone Generation Characteristic of $Al_2O_3$ (아루미나 방전관의 무성방전 및 오존발생특성)

  • Kim, Hag-Gyu;Kwak, Dong-Joo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.908-911
    • /
    • 2002
  • Recently deep interests and attraction have been paid on the generation of ozone, which is widely used to remove bed smell and to clear water. In this paper the silent discharge and ozone generation characteristics of various typed discharge chambers were investigated experimentally. Dielectric of $Al_2O_3$ was embedded in the cylindrical type of discharge chamber to improve the ozone generation rate and to stabilize the silent discharge mode of operation. Discharge current and ozone concentration depend strongly on the applied voltage and frequency.

  • PDF

Trial Manufacture of Ozone Generator Using Silent Discharge Type and Improvement Properties of the Water Quality in the Lake (무성방전형 오존발생장치 제작 및 수질 개선 특성)

  • 임헌찬;김진규;우성훈
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.50 no.3
    • /
    • pp.125-129
    • /
    • 2001
  • ln this paper, a ozone generator using superimposition of silent discharge has been designed and manufactured. This type ozone generator is equipped with three electrodes and two gaps. Ozone is generated by superimposition of silent discharge, which is respectively come from two gaps. The maximum values of ozone concentration, ozone generation flow and ozone energy field were obtained 4,750[ppm], 2.37[g/h], 102.3[g/kWh]. Also, the result of reaction of 1,8921ppm] ozone and the sampling water from the lake, the water quality was improved from IV grade to In grade, and obtained 100[%] sterilization rate of Escherichia coli within 5.0(min).

  • PDF