• 제목/요약/키워드: Silencers

검색결과 59건 처리시간 0.028초

INSERTION LOSS MEASUREMENT OF SILENCERS BY DOUBLE PAIR MICROPHONE TECHNIQUE

  • Jung, S.S.;Pu, Y.C.;Kim, M.G.
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1994년도 FIFTH WESTERN PACIFIC REGIONAL ACOUSTICS CONFERENCE SEOUL KOREA
    • /
    • pp.704-709
    • /
    • 1994
  • The insertion loss is the measured change in power flux at a specified receiver, when the acoustic transmission path between it and the source is modified by the insertion of silencer element. Such measurements have clear and valid physical meaning particularly if the source impedance remains while the transmission path is altered. When the invarient condition is satisfied, the insertion loss is given by the ratio of the acoustic pressure in upstream to that in downstream of the silencer, and that of the particle velocity. The measurement is consisted of using an adaptation of the two microphone method to obtain the complex amplitude of the sound in upstream tube as well as in downstream tube of the silencer. Examples of the data, reduced and presented in terms of the pressure ratio and particle speed ratio, are compared with the theoretical calculations.

  • PDF

Silencer 및 DNA methylation에 의한 JC virus early promoter의 뇌교세포 특이적인 조절 (Glial Cell-specific Regulation of the JC virus Early Promoter by Silencer and DNA Methylation)

  • 김희선;우문숙
    • 약학회지
    • /
    • 제46권2호
    • /
    • pp.143-148
    • /
    • 2002
  • The human polyomavirus JC virus is the etiologic agent of progressive multifocal leukoencephalopathy (PML). The JC virus early promoter directs cell-specific expression of the viral replication factor large T antigen, thus transcriptional regulation constitutes a major mechanism of glial tropism in PML. Here we found that pentanucleotide sequence immediately upstream of the TATA sequence functions as a cell-specific silencer in the JC virus transcription. In vitro binding studies showed that synthetic oligonucleotides spanning a pentanucleotide sequence, designated "oligo 2", interacts with nuclear proteins from non-glial cells in a cell-specific manner. Furthermore, the sequence preferentially repressed the heterologous thymidine kinase promoter activity in non-glial cells. We also tested whether JC virus transcription is controlled by DNA methylation. Transient transfection of in vitro methylated JC virus promoter abolished transcription in both the glial and non-glial cells. The repression fold was much larger in glial cells than in non-glial cells. Taken together, this finding suggests that glial cell-specific expression of the JC virus is controlled by DNA methylation as well as cell-specific silencers.

Hole-Cavity 공명기술과 미세공 스테인레스칩 소결 융합 소음기의 소음성능에 관한 연구 (A Study on the Noise Performance of Silencer Fused with Hole-Cavity Resonance Technology and Micro-Sphere Stainless Chip Sintering Technology)

  • 조동현;백남도
    • 한국기계가공학회지
    • /
    • 제18권1호
    • /
    • pp.101-108
    • /
    • 2019
  • In this study, the hole-cavity resonance technology and the micro pore stainless chip sintering technology were fused to develop silencers with excellent noise attenuation performance even at fluid pressures exceeding 30 bar for the first time at home and abroad. As a result of this study, the noise attenuation performance was greatly improved as reflection, loss, and resonance were made to occur thousands of times simultaneously when fluids pass through the sintered micro pore stainless steel chip sound absorber. The noise of the gas emitted from the bomb without the silencer was shown to be 125dB. And noise test conducted after installation of the silencer showed the noise of 67dB. Given the study results, the amount of noise was greatly reduced in the sintered silencer.

흡음형 디퓨저 소음기의 성능 (Performance of Absorption Diffuser Silencers)

  • 정갑철;현승일;이종우;권영필
    • 소음진동
    • /
    • 제4권3호
    • /
    • pp.377-384
    • /
    • 1994
  • This paper is an investigation of the performance of absorption diffusers to suppress the vent noise emitted when high pressure gas is throttled. First, experiment for the static performance is carried out. When there is no through-flow, the insertion loss has been obtained in terms of 1/3 octave band spectrum and the effect of the number of diffusers and the thickness of the absorption material on the static performance has been obtained. And the similarity in the spectrum of the static insertion loss is confirmed by comparing two similar models with different size. Second, the dynamic performance has been obtained by experiment using blow-down of compressed air from a storage tank through an orifice of diameter 10 mm. The back pressure by the diffuser is measured and compared with that of a single diffuser. It is found that the insertion loss of asingle diffuser is very low around 3 dB at high frequencies with negative value at low frequencies. By absorption material between the diffuser tubes, however, the performance is increased considerably. Without flow the static insertion loss increases by 3 - 4 dB by doubling the thickness or the density of the absorptionmaterial. With flow, however, the dynamic insertion loss increases. While, the back pressure by the diffuser is small enough to be neglected.

  • PDF

디젤엔진 공기과급기의 압력맥동 기인소음 평가기법 개발 (Development of the Evaluation Method for Aerodynamic Noise Caused by Pressure Pulsation in the Turbocharged Diesel Engine)

  • 이종규;김형진;강구태
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.918-922
    • /
    • 2007
  • Aero-pulsation noise, generally caused by geometric asymmetry of a rotating device, is considerable source of annoyance in passenger cars using the turbocharged diesel engine. Main source of this noise is the compressor wheel in the turbocharger system, and can be reduced by after-treatment such as silencers, but which may increase the manufacturing cost. More effective solution is to improve the geometric symmetry over all, or to control the quality of components by sorting out inferior ones. The latter is more effective and reasonable than the former in view of manufacturing. So, an appropriate discrimination method should be needed to evaluate aero-pulsation noise level at the production line. In this paper, we introduce the accurate method which can measure the noise level of aeropulsation and also present its evaluation criteria. Besides verifying the reliability of a measurement system - a rig test system -, we analyze the correlation between the results from rig tests and those from vehicle tests. The gage R&R method is carried out to check the repeatability of measurements over 25 samples. From the result, we propose the standard specification which can discriminate inferior products from superior ones on the basis of aero-pulsation noise level.

  • PDF

기하상사법을 이용한 대형 소음기의 성능평가에 관한 해석적 연구 (Analytical Study on Performance Evaluation of Large-Sized Silencer using Geometric Similarity Law)

  • 양준혁;이부윤;김원진
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권2호
    • /
    • pp.275-281
    • /
    • 2010
  • 선박용 엔진 또는 플랜트 시스템에 사용되는 대형 소음기의 개발단계에서 비용절감 및 개발기간의 단축을 위하여 축소모형으로 대체 실험이 가능하도록 기하상사법을 제안하고자 한다. 대형 소음기를 구성하고 있는 공명형과 단순 확장관형 소음기의 원형과 축소 모형에 대한 이론식으로부터 기하상사 변수를 규명하였다. 그리고 음향해석을 통하여 조합형과 배플형의 축소 모형에 기하상사법을 적용하여 원형모형의 성능을 예측하고, 이를 원형모형의 실제 성능과 비교하는 방법으로 기하상사 변수를 검증하였다.

조합형 소음기를 이용한 육상발전용 디젤 엔진의 흡기 소음 제어 (Intake Noise Control of Diesel Power Plant using Combined Silencer)

  • 송근복;주원호;김동해
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.861-866
    • /
    • 2012
  • Turbo-charger noise radiated from air intake part is one of the most important noise sources in diesel power plant. In this paper, intake noise control of the diesel power plant was studied using parallel baffle type silencer and concentric hole-cavity resonator simultaneously. Firstly, acoustical characteristics and attenuation performance for parallel baffle type silencer were investigated through theoretical approach and experimental method. Based on the results, optimal design of the parallel baffle silencer was suggested. Secondly, for reducing the low frequency noise contained in the intake noise, the concentric hole-type resonator was developed and the acoustic performance was verified from the test. By combining two types of silencers, it is expected that the overall insertion loss is about 50 dB. So, the combined silencer is very helpful in reducing the intake noise of diesel power plant.

  • PDF

고전압 COS 퓨즈용 소음기의 소음저감 및 전류차단 성능에 관한 실험적 연구 (An Experimental Study on the Noise Reduction and the Feasibility of Short Current of a Silencer for a High Voltage COS Fuse)

  • 이동훈;송화영
    • 한국소음진동공학회논문집
    • /
    • 제18권7호
    • /
    • pp.783-789
    • /
    • 2008
  • This experimental study describes the noise reduction and the feasibility of short current of a silencer for a high voltage COS(cut out switch) fuse of a transformer. When a high voltage COS fuse becomes a short circuit by the over current, the strong impulse noise over 150 dB(A) is generated. For the purpose of the reduction of impulse noise, in this study, the diffuser type and the reactive type silencers have been designed and tested, respectively. And also the electrical test on the short current is performed. From the experimental results, the well designed reactive type silencer has been shown to have the noise reduction of about 20 dB(A). It has been found that the feasibility of short current for the COS fuse is closely related to the porosity of the silencer.

전동차 브레이크 스퀼 소음 현상에 대한 연구 (Study on the phenomena of brake squeal noise in rail vehicle)

  • 양용준;김성걸;박영일
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.405-410
    • /
    • 2004
  • There are two types of noises in running the rail vehicle. The one is periodic by electric motors, dehumidifiers, and dusting machines. And the other is aperiodic squeal noise by the frictions between the wheels and the rail or the disks and pads. The periodic noises in rail vehicle have been reduced by changing DC motors to AC motors with silencers, and by improving the lubricants. However, almost nothing relating a periodic noise has been studied. In this paper, the experimental methods were applied to understand phenomena of the squeal noise, which was occurred by the friction variation due to aperiodic stick and slip with low repeatability in the process of dry friction of the disk and the pad when a rail vehicle was being braked. By the experimental acoustic test, it was found the specific frequencies relating the squeal noise. And by modal testing, it was measured the resonant frequencies in the disk and the pad-plate which were the components of the braking system, and in the whole braking system, and it was found the specific frequencies having the effects on the squeal noise.

  • PDF

건설사업장의 날림먼지 및 소음 저감 기술 적용사례 비교분석 (Comparative Study on the Control Technologies of Fugitive Dusts and Noise of Construction Project in Korea)

  • 구자건;강미연;서용칠
    • KIEAE Journal
    • /
    • 제9권1호
    • /
    • pp.55-60
    • /
    • 2009
  • This study was carried out to propose the optimum technologies that can be applicable to noise and fugitive dust controlling in construction sites by comparative analysis in cases. The ninety three environmental management technologies applied to fifty-five construction projects conducted during 2005~2007 in Korea were analyzed by checklist method. The construction companies paid more attention to the noise and fugitive dust controlling technologies than the waste and wastewater. The diverse pollution controlling techniques were applied to the architectural projects than the civil projects to meet the environmental requirements in residential area. The fugitive dust controlling technologies(75.3%) were more widely applied to all construction projects than the noise controlling technologies(24.7%). As the noise controlling techniques, the noise barriers in wall-form which are set up as boundary in construction site were more widely used than the noise barriers in curtain-form, in cabin and silencers. Water spraying systems, wind barriers and mechanical sweepers were the preferred technologies for controlling fugitive dust emission.