• 제목/요약/키워드: Signal void

검색결과 65건 처리시간 0.025초

개량된 다채널 임피던스형 측정기에 의한 기포율의 측정 (Void Fraction Measurement by the Improved Multi-Channel Impedance Void Meter)

  • 송철화;정문기
    • 대한기계학회논문집B
    • /
    • 제20권1호
    • /
    • pp.384-398
    • /
    • 1996
  • An improved multi-channel Impedance Void Meter (IVM) is developed to measure an area-averaged void fraction. It consists of a main sensor, a reference sensor and a signal processor. The sensor was designed to be flush-mounted to the inner wall of the test section to avoid the flow disturbances. Guard electrodes are used to obtain evenly distributed electrical field in a measuring volume. A reference sensor is also installed to eliminate the drift in void signal caused by the changes in electrical properties of working fluid. The signal processor with three channels is specially designed so as to minimize the inherent error due to the phase difference between channels. As an example of applications, the mean and fluctuating components of void fraction are measured for bubbly and slug flow regime, and it is shown that IVM has good dynamic resolution which is required to investigate the structural developments of bubbly flow and the propagation of void waves in a flow channel.

배뇨력 측정을 통한 하부요로계의 보상성기능항진 평가 (Estimation of compensatory hypertrophy in lower urinary system using void force measurement)

  • 정도운;전계록
    • 센서학회지
    • /
    • 제15권6호
    • /
    • pp.449-456
    • /
    • 2006
  • The purpose of urodynamic investigation is to obtain the information on the function of the urinary system. The aim of this study is to acquire the useful information of lower urinary tract symptom (LUTS) diagnosis through void force signal as noninvasive method. The system which could evaluate the function of compensatory hypertrophy with noninvasive and comfortable method was implemented to measure uroflow and void force during urination. The implemented system composes of the sensor parts, signal conditioning parts and PC monitoring program. For the evaluation of the implemented system, the simulation of control part of the system was performed and the model system for the lower urinary system was designed. The superiority of a measuring characteristic of the implemented system was verified using the model system. From the evaluation of the model system, we have found out that the void force was dependent on the occlusion degree and compensatory hypertrophy significantly.

웨이블렛변환을 이용한 부분방전 종류의 특징추출에 관한 연구 (A Study on Feature Extraction of Partial Discharge Type Using Wavelet Transform)

  • 박재준
    • 정보학연구
    • /
    • 제6권1호
    • /
    • pp.65-70
    • /
    • 2003
  • 본 논문에서 우리는 변압기의 부분방전형태를 진단하기위하여 새로운 방법을 제시하였다. 웨이블렛 변화을 위하여, 다우비치 필터가 사용되어졌다. 우리는 3개의 전극 종류(침대평판자극, IEC전극, 보이드 전극)마다 고주파 전류신호에 관한 통계적인 특징 파라메터(최대값, 평균값, 분산, 왜도, 첨쇄도)를 추출하기위하여 사용하였다. 역시 이들 계수들은 변압기내 내부부분방전의 신호의 정체를 알기위하여 사용되어졌다. 그 결과로서 고주파전류신호의 진폭과 평균값의 비교로부터 우리는 IEC electrode> Void electrode> Needle-Plane electrode의 결과를 얻었다. 반면에 왜도와 첨쇄도의 경우, 우리는 Void electrode> IEC electrode> Needle-Plane electrode을 얻었다.

  • PDF

변압기내 노이즈제거를 통한 초음파 신호 검출 (Ultrasonic Signal Detection in a Transformer Through Noise Elimination)

  • 박현수;곽희로;박중신
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2000년도 학술대회논문집
    • /
    • pp.231-234
    • /
    • 2000
  • The corona in oil, the surface discharge in oil, the void discharge which could be in a transformer were imitated by using three electrodes with different shapes and the frequency bands of each ultrasonic signal were measured. After emitting artificial noises toward the transformer, only ultrasonic signals were extracted by frequency filtering, from the ultrasonic signals with noises at partial discharge. As a result, it was confirmed that the ultrasonic signals due to the corona in oil, the surface discharge in oil, the void discharge could be distinguished from the noises.

  • PDF

비선형 위상공간에서의 기포 분율 신호의 끌개밀도분식을 이용한 수직 상향 이상유동의 유동패턴분류 (Flow Pattern Identification of Vertical Upward Two-Phase Flow Using the Attractor-Density-Map Analysis of the Void Fraction Signal in the Nonlinear Phase Space)

  • 김남석;이재영
    • 대한기계학회논문집B
    • /
    • 제28권11호
    • /
    • pp.1398-1406
    • /
    • 2004
  • The nonlinear signals from an impedance meter for the area average void fraction in two-phase flow have been analyzed to construct a phase space trajectory. The pseudo phase space was constructed with the time delay and proper dimensions. The time delay and the embedding dimension were chosen by the average mutual information and by the false nearest neighborhood, respectively. The attractor-density-map of projected states was used to produce the two dimensional probability distribution functions (2D-PDF). Since the developed 2D-PDF showed clear distinction of the flow patterns, the flow regime identification was made with three rules and with the 2D-PDF. Also, the transition criteria of Mishima-Ishii agree well with the present results.

웨이블렛-신경망을 이용한 부분방전 종류와 진단에 관한연구 (A Study on Diagnosis of Partial Discharge Type Using Wavelet Transform-Neural Network)

  • 박재준;전현구;전병훈;김성홍;권동진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.894-899
    • /
    • 2002
  • In this papers, we proposed the new method in order to diagnosis partial discharge type of transformers. For wavelet transform, Daubechies filter is used, we can obtain wavelet coefficients which is used to extract feature of statistical parameters (maximum value, average value, dispersion, skewness, kurtosis) about high frequency current signal per 3-electrode type (needle-plane electrode, IEC electrode and Void electrode.). Also. these coefficients are used to identify Signal of internal partial discharge in transformer. As a result. from compare of high frequency current signal amplitude and average value. we are obtained results of IEC electrode> Void electrode> Needle-Plane electrode. otherwise. In case of skewness and kurtosis, we are obtained results of Void electrode> IEC electrode > Needle-Plane electrode. As Improved method in order to diagnosis partial discharge type of transformers, we use neural network.

  • PDF

이산웨이블렛 변환기법을 이용한 부분방전종류의 신호특징추출에 관한연구 (A Study on Signal Feature Extraction of Partial Discharge Types Using Discrete Wavelet Transform Technique)

  • 박재준;전병훈;김진승;전현구;백관현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.170-176
    • /
    • 2002
  • In this papers, we proposed the feature extraction method due to partial discharge type of transformers. For wavelet transform, Daubechie's filter is used, we can obtain wavelet coefficients which is used to extract feature of statistical parameters (maximum value, average value, dispersion, skewness, kurtosis) about acoustic emission signal generated from each partial discharge type. The defects which could occur in a transformer were simulated by using needle-plane electrode, IEC electrode and Void electrode. Also, these coefficients are used to identify signal of partial discharge type electrode fault in transformer. As a result, from compare of acoustic emission amplitude and acoustic average value, we are obtained results of IEC electrode> Void electrode> Needle-Plane electrode. otherwise, In case of skewness and kurtosis, we are obtained results of Needle-Plane electrode electrode> Void electrode> IEC electrode.

  • PDF

Evaluation of Modified Turbo Spin Echo Technique Compared with Double Inversion Recovery Technique in Acquisition of Black Blood Brain Vessel Image

  • Choi, Kwan-Woo;Lee, Ho-Beom;Na, Sa-Ra;Son, Soon-Yong
    • Journal of Magnetics
    • /
    • 제21권1호
    • /
    • pp.148-152
    • /
    • 2016
  • The main goal was to evaluate effectiveness of a modified TSE sequence compared with DIR (double inversion recovery) sequence in acquisition of fast flow brain vessel images using signal void effect. 32 healthy volunteers (10 men and 22 women; mean age of 31 years; ranging between 28-43 years) who underwent black blood DIR sequence (group A) and the modified TSE sequence (group B) were enrolled in our study. Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR) of the internal carotid arteries' lumen were compared in T1 and T2 weighted images for both group A and B. The images obtained from group B showed lower SNR values in internal carotid artery than the group A in both of the T1 and T2 weighted images (11.49% and 13.66% respectively). While the CNR values were higher in the group B than the group A in both of the T1 and T2 weighted images (8.69% and 7.55 % respectively). The qualitative score of all categories were not significantly different between the two groups. Furthermore approximately 49% of the total scan time was reduced from group B. Our study is to shorten the scanning time and minimize the inconveniences of the patients in acquisition of the black blood images of brain by using the signal void effect in the modified TSE technique while keeping the diagnostic value of the test.

수직사각 유로내에서의 국부적 기포계수 측정에 관한 연구 (A Study on the Measurement of Local Void Fraction)

  • B.J. Yun;Kim, K.H.;Park, G.C.;C.H. Chung
    • Nuclear Engineering and Technology
    • /
    • 제24권2호
    • /
    • pp.168-177
    • /
    • 1992
  • 이상유동 현상의 해석은 원자력 발전소의 각계통과 가압경수형 원자로의 안전성 분석, 각종 열 수력학적 현상의 해석 그리고 타 산업체의 필요성에 의해 그 연구의 중대성이 커지고 있다. 이러한 이상유동의 현상 해석에 있어서 국부적 영역에서의 기포계수 결정은 매우 중요하다. 본 연구에서는 이러한 이상유동시 국부적 기포계수의 측정을 위하여 원자로내 부수로를 모사한 수직사각 유로를 제작하였다. 또한 국부적 영역에서의 기포계수 측정에 적합한 것으로 알려진 전기탐침 및 그 부가회로를 제작하였으며, 완성된 탐침을 이용하여 실제 비등이 발생하는 실험용 유로내에서 국부적 기포계수의 측정을 시도하였다. 실험 결과 제작된 전기탐침 및 그부가회로의 타당성을 확인 할 수 있었다.

  • PDF

AN IMPROVED ELECTRICAL-CONDUCTANCE SENSOR FOR VOID-FRACTION MEASUREMENT IN A HORIZONTAL PIPE

  • KO, MIN SEOK;LEE, BO AN;WON, WOO YOUN;LEE, YEON GUN;JERNG, DONG WOOK;KIM, SIN
    • Nuclear Engineering and Technology
    • /
    • 제47권7호
    • /
    • pp.804-813
    • /
    • 2015
  • The electrical-impedance method has been widely used for void-fraction measurement in two-phase flow due to its many favorable features. In the impedance method, the response characteristics of the electrical signal heavily depend upon flow pattern, as well as phasic volume. Thus, information on the flow pattern should be given for reliable void-fraction measurement. This study proposes an improved electrical-conductance sensor composed of a three-electrode set of adjacent and opposite electrodes. In the proposed sensor, conductance readings are directly converted into the flow pattern through a specified criterion and are consecutively used to estimate the corresponding void fraction. Since the flow pattern and the void fraction are evaluated by reading conductance measurements, complexity of data processing can be significantly reduced and real-time information provided. Before actual applications, several numerical calculations are performed to optimize electrode and insulator sizes, and optimal design is verified by static experiments. Finally, the proposed sensor is applied for air-water two-phase flow in a horizontal loop with a 40-mm inner diameter and a 5-m length, and its measurement results are compared with those of a wire-mesh sensor.