• Title/Summary/Keyword: Signal transducer

Search Result 429, Processing Time 0.022 seconds

A study on dynamic characteristics in extension tube and correction of pressure distortion for a S/P type pressure transducer (스파크 플러그형 압력센서에서 연결관로의 동적특성과 압력왜곡의 보상에 관한 연구)

  • 한승국;김승수
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.13 no.3
    • /
    • pp.32-42
    • /
    • 1991
  • In SI engine research the pressure data in cylinder is the most important fundamental ones leading to engine efficiencies and performances. It is, therefore, necessary to obtain accurate pressure data and yet it is often impossible to install a reliable data producing, flush-mounted type pressure transducer in a cylinder of small and medium size multicylinder SI engines. When flush mounting the transducer is not possible, the spark-plug type pressure transducer is commonly used as an alternative. In this case, the transmission tube of spark-plug type pressure transducer introduces distortions in the pressure signal. Efforts were made to understand the dynamic characteristics of spark-plug pressure transducer by shock tube tests and real engine experiments. In engine experiment the cylinder pressure data were simultaneously obtained by both flush mounted and spark-plug type pressure transducers of certain transmission tube geometry. Those pressure data collected by spark-plug type pressure transducer were tested for correction to flush mounted ones by the application of transfer function. As a result of the calibration the IMEP difference between F/M data and improved S/P data was shown to be corrected about 75-98% from the original ones.

  • PDF

An Accurate Small Signal Modeling of Cylindrical/Surrounded Gate MOSFET for High Frequency Applications

  • Ghosh, Pujarini;Haldar, Subhasis;Gupta, R.S.;Gupta, Mridula
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.12 no.4
    • /
    • pp.377-387
    • /
    • 2012
  • An intrinsic small signal equivalent circuit model of Cylindrical/Surrounded gate MOSFET is proposed. Admittance parameters of the device are extracted from circuit analysis and intrinsic circuit elements are presented in terms of real and imaginary parts of the admittance parameters. S parameters are then evaluated and justified with the simulated data extracted from 3D device simulation.

Nonlinear Time Reversal Focusing and Detection of Fatigue Crack

  • Jeong, Hyun-Jo;Barnard, Dan
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.4
    • /
    • pp.355-361
    • /
    • 2012
  • This paper presents an experimental study on the detection and location of nonlinear scattering source due to the presence of fatigue crack in a laboratory specimen. The proposed technique is based on a combination of nonlinear elastic wave spectroscopy(NEWS) and time reversal(TR) focusing approach. In order to focus on the nonlinear scattering position due to the fatigue crack, we employed only one transmitting transducer and one receiving transducer, taking advantage of long duration of reception signal that includes multiple linear scattering such as mode conversion and boundary reflections. NEWS technique was then used as a pre-treatment of TR for spatial focusing of reemitted second harmonic signal. The robustness of this approach was demonstrated on a cracked specimen and the nonlinear TR focusing behavior is observed on the crack interface from which the second harmonic signal was originated.

Ultrasonic Distance Measurement Method by Using the Envelope Model of Received Signal Based on System Dynamic Model of Ultrasonic Transducers

  • Choe, Jin-Hee;Lee, Kook-Sun;Choy, Ick;Cho, Whang
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.981-988
    • /
    • 2018
  • In order to acquire an accurate TOF, this paper proposes a method that produces TOF by using a mathematical model for the envelope of the received signal obtained from a system dynamic model of ultrasonic transducer. The proposed method estimates the arrival time of the received signal retrospectively by comparing its wave form obtained after triggering point with its mathematical envelope model. Experimental result shows that the error due to variation of triggering point can be dramatically decreased by implementing the proposed method.

Development of Ultrasonic Sensor to Measure the Distance in Underwater (수중 거리 측정을 위한 초음파 센서의 개발)

  • Kim, Chi-Hyo;Kim, Tae-Sung;Jung, Jun-Ha;Lee, Jin-Hyung;Lee, Min-Ki;Jang, In-Sung;Shin, Chang-Joo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2013.06a
    • /
    • pp.293-298
    • /
    • 2013
  • This research develops an ultrasonic sensor to measure the distance in underwater. The ultrasonic transducer transmits an acoustic signal to an object and receives the echo signal reflected from the object. The ultrasonic driver calculates a distance by multiplying the acoustic speed to the time of flight(TOF) which is the time necessary for the acoustic signal to travel from the transducer to the object. We apply a thresholding and a cross correlation methods to detect the TOF and show their results. When an echo pulse is corrupted with noise and its shape is distorted, the cross correlation method is used to find the TOF based on the maximum similarity between the reference and the delayed echo signals. The echoes used for the reference signal are achieved at the different environments, which improves the performance of the sensor. This paper describes the driver of the acoustic sensor and analyzes the performance of sensors in different measurement environments.

  • PDF

Cinnamomum camphora Leaves Alleviate Allergic Skin Inflammatory Responses In Vitro and In Vivo

  • Kang, Na-Jin;Han, Sang-Chul;Yoon, Seok-Hyun;Sim, Jae-Yeop;Maeng, Young Hee;Kang, Hee-Kyoung;Yoo, Eun-Sook
    • Toxicological Research
    • /
    • v.35 no.3
    • /
    • pp.279-285
    • /
    • 2019
  • In this study, we investigated the therapeutic potential of Cinnamomum camphora leaves on allergic skin inflammation such as atopic dermatitis. We evaluated the effects of C. camphora leaves on human adult low-calcium high-temperature keratinocytes and atopic dermatitis mice. C. camphora leaves inhibited Macrophage-derived chemokine (an inflammatory chemokine) production in $interferon-{\gamma}$ (10 ng/mL) stimulated Human adult low-calcium high-temperature keratinocytes in a dose dependent manner. C. camphora leaves suppressed the phosphorylation of janus kinase signal transducer and activator of transcription 1. C. camphora leaves also suppressed the phosphorylation of extracellular signal-regulated kinase 1/2, a central signaling molecule in the inflammation process. These results suggest that C. camphora leaves exhibits anti-inflammatory effect via the phosphorylation of signal transducer and activator of transcription 1 and extracellular signal-regulated kinase 1/2. To study the advanced effects of C. camphora leaves on atopic dermatitis, we induced experimental atopic dermatitis in mice by applying 2,4-dinitrochlorobenzene. The group treated with C. camphora leaves (100 mg/kg) showed remarkable improvement of atopic dermatitis symptoms: reduced serum immunoglobulin E levels, smaller lymph nodes with reduced thickness and length, decreased ear edema, and reduced levels of inflammatory cell infiltration in the ears. Interestingly, the effects of C. camphora leaves on atopic dermatitis symptoms were stronger than those of hydrocort cream, a positive control. Taken together, C. camphora leaves showed alleviating effects on the inflammatory chemokine production in vitro and atopic dermatitis symptoms in vivo. These results suggest that C. camphora leaves help in the treatment of allergic inflammation such as atopic dermatitis.

Design, fabrication and performance characteristics of a 50kHz tonpilz type transducer with a half-wavelength diameter (반파장 직경을 갖는 50kHz tonpilz형 음향 변환기의 설계, 제작 및 성능특성)

  • Lee, Dae-Jae;Lee, Won-Sub
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.46 no.2
    • /
    • pp.173-183
    • /
    • 2010
  • In a split beam echo sounder, the transducer design needs to have minimal side lobes because the angular position and level of the side lobes establishes the usable signal level and phase angle limits for determining target strength. In order to suppress effectively the generation of unwanted side lobes in the directivity pattern of split beam transducer, the spacing and size of the transducer elements need to be controlled less than half of a wavelength. With this purpose, a 50 kHz tonpilz type transducer with a half-wavelength diameter in relation to the development of a split beam transducer was designed using the equivalent circuit model, and the underwater performance characteristics were measured and analyzed. From the in-air and in-water impedance responses, the measured value of the electro-acoustic conversion efficiency for the designed transducer was 51.6%. A maximum transmitting voltage response (TVR) value of 172.25dB re $1{\mu}Pa/V$ at 1m was achieved at 52.92kHz with a specially designed matching network and the quality factor was 10.3 with the transmitting bandwidth of 5.14kHz. A maximum receiving sensitivity (SRT) of -183.57dB re $1V/{\mu}Pa$ was measured at 51.45kHz and the receiving bandwidth at -3dB was 1.71kHz. These results suggest that the designed tonpilz type transducer can be effectively used in the development of a split beam transducer for a 50kHz fish sizing echo sounder.

Focal Length Control of Line-focus Ultrasonic Transducer Using Bimorph-type Bending Actuator (바이몰프형 밴딩 액츄에이터를 이용한 선집속형 초음파 트랜스듀서의 초점 거리 제어)

  • 채민구;하강열;김무준
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.3
    • /
    • pp.202-207
    • /
    • 2003
  • For medical ultrasonic transducer, phase-weighting method has been used for controlling focal length with electric circuit at each vibrating element. However, the electric circuit is complex as the number of vibrating elements is increased. In this paper, we fabricated line-focus transducer with a bimorph-type piezoelectric actuator. The polyvinylidene fluoride (PVDF) piezoelectric type polymer film is used for transmitting and receiving of ultrasonic signal. Using this transducer, focal length of the transducer can be controlled mechanically by changing voltage of the actuator. It is confirmed that focal length of the transducer can be controlled in range of 1095 to radius of curvature.

Fabrication of transducer optimized acousto optic modulator for laser projection display (Transducer 최적화 설계에 의한 Laser Projection Display용 음향광학변조기 제작 및 특성평가에 대한 연구)

  • 차승남;이항우;김용훈;황영모
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.5
    • /
    • pp.410-414
    • /
    • 1997
  • Laser projection display is a full color display system for large area. In this system, laser beams are modulated at acousto optic modulators(AOM) according to the video signal. AOM consists of a $TeO_2$ crystal and a $LiNbO_3$ transducer. We calculated the acoustic wave propagating from transducer to acousto optic media and made AOM by the calculated results. We compared calculated results with fabricated AOM by measuring modulation efficiency at various frequency. The modulation efficiency of AOM is 85% at the carrier frequency of 144MHz and the rise time is 41.5 ns.

  • PDF

Field Analysis of surface Acoustic Wave Transducers (표면파 트랜스튜서의 전자이론적 분석)

  • 강창언
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.17 no.6
    • /
    • pp.17-23
    • /
    • 1980
  • The transmission and reception characteristics of surface acoustic wave devices are analyzed by introducing three different types of transducers. such as single-electrode transducer. double-electrode transducer and triple-electrode transducer. Utilizing an electromagletic field theory technique, the output signal has been derived theoretically. The basic analysis used here can be extended for other configurations. The surface acoustic devices have been shown promising as a means of improving the operation efficiency by modifying the Beometric configuration of transducer strips.

  • PDF