• Title/Summary/Keyword: Signal metering

Search Result 40, Processing Time 0.03 seconds

A Study on the Signal Anti-reduction Equipment in Power Line Communication (전력선 통신 시스템을 위한 신호 감쇠 저하 장치 연구)

  • 김주환
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.103-106
    • /
    • 2000
  • In this paper a communication system that is not using the communication line but power line is presented. It will be very useful for an information-oriented society with tele-metering and home automation. Conventional system has a difficulty in transmitting information due to decreasing communication voltage and increasing carrier, current. Proposed idea is a special type switching amplifier system which has a low inner resistance. It can provide reactive power and dose not have low impedance between the transceivers. This new system is proposed to overcome the loss of conductor load in a PLC system.

  • PDF

Traffic signal control system using fuzzy logic (Fuzzy logic을 利用한 交通 信號 control system)

  • 文珠永;李尙培
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1996.10a
    • /
    • pp.180-183
    • /
    • 1996
  • This work discusses simulation results for the fuzzy logic controller tested the project“Fuzzy Ramp Metering Algorithm Implementation.”The performance objectives were, in order of priority, to maximize total vehicle-miles, maximize mainline speeds, and minimize delay per vehicle while maintaining an acceptable ramp queue. In the fuzzy logic controller, the sensors from the on-ramps were helpful in maintaining reasonable ramp queue and mainline congestion because it considered these factors simultaneously. Each metered ramp had a parameter input file, which allowed the controller to be modified without recompiling the software. Consequently, maintenance costs should be minimal.

  • PDF

Determination of Control Time Point for Internal Metering Policy Application within COSMOS Environments (실시간신호시스템 환경내 내부미터링 적용 시점에 관한 연구)

  • Lee, Sang-Soo;Song, Sung-Ju;Lee, Choul-Ki
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.7 no.1
    • /
    • pp.22-31
    • /
    • 2008
  • RT/IMPOST is an effective algorithm that can realize real-time internal metering policy (IMP) using queue information from loop detector and signal control strategies. In this paper, an investigation was made to adopt the IMP methodology within COSMOS environments in terms of communication environment and control time point. Through the analysis of the communication environment of COSMOS and communication and control steps in RT/IMPOST, a set of applicable alternative were developed and evaluated. Then, one of the alternatives was selected, and performance of the alternative was compared with RT/IMPOST system using a simulation technique. Results showed that two techniques produced the similar performance. Therefore, the method suggested in this paper was evaluated as a practically viable alternative.

  • PDF

A Signal Anti-reduction System in PLC using Ferrite Core and Switching Amplifier (페라이트 코어와 스위칭 증폭기를 이용한 PLC 신호 감쇠 저하 시스템)

  • 고종선;김영일;김규겸
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.6
    • /
    • pp.474-480
    • /
    • 2001
  • In this paper a low signal reduction communication system that does not use the communication line but power line is presented It will be very useful for an information-oriented society with tele-metering and home automation. The conventional system has a difficulty in transmitting information due to decreasing communication voltage. The proposed system employs a special type switching amplifier system which has a low inner resistance and uses high efficient ferrite core in coupling circuit. This new system is proposed to reduce the loss of conductor load and coupling circuit in a PLC system.

  • PDF

Signal Optimization for Oversaturated Arterials (과포화 간선도로의 신호 최적화)

  • 최병국
    • Journal of Korean Society of Transportation
    • /
    • v.15 no.2
    • /
    • pp.67-82
    • /
    • 1997
  • 일반적으로 교통수요가 용량보다 적으면 모든 교통량이 지체없이 신호교차로를 통 과 할 수 있을 것이다. 이러한 비포화 상태에서는 어떻게 Delay나 Stop을 최소화시키느냐가 신호처리의 목적함수가 될 것이다. 그러나 교통수요가 용량보다 많아지면 신호교차로가 모 든 교통량을 통과시키지 못하므로 시간이 갈수록 대기 행렬이 점점 길어질 것이다. 이러한 과포화상태에서는 늘어나는 대기 행렬을 조절하지 못하면 결국에는 Spillback이 상류 교차 로로 확대되어 최악에는 교차로에서의 모든 방향의 움직임을 정지시키는 Gridlock상태로까 지 악화 될 수 있다. 따라서 과포화 상태에서는 비포화 상태와는 달리 늘어나는 대기행렬을 조절하여 통과 교통량을 최대화 시키는 것이 신호처리의 목적 함수가 될 수 있을 것이다. 본 논문에서는 과포화시의 간선도로를 신호처리에 의해 일정한 대기행렬을 유지하므로써 시 스템을 최적화 하는 알고리즘을 개발하였다. IMPOST(Internal Metering Policy to Optimize Signal Timing)는 논문에서 개발한 알고리즘을 C언어로 프로그래밍한 model이다.

  • PDF

An Incident-Responsive Dynamic Control Model for Urban Freeway Corridor (도시고속도로축의 유고감응 동적제어모형의 구축)

  • 유병석;박창호;전경수;김동선
    • Journal of Korean Society of Transportation
    • /
    • v.17 no.4
    • /
    • pp.59-69
    • /
    • 1999
  • A Freeway corridor is a network consisting of a few Primary longitudinal roadways (freeway or major arterial) carrying a major traffic movement with interconnecting roads which offer the motorist alternative paths to his/her destination. Control measures introduced to ameliorate traffic performance in freeway corridors typically include ramp metering at the freeway entrances, and signal control at each intersections. During a severe freeway incident, on-ramp metering usually is not adequate to relieve congestion effectively. Diverting some traffic to the Parallel surface street to make full use of available corridor capacity will be necessary. This is the purpose of the traffic management system. So, an integrated traffic control scheme should include three elements. (a)on-ramp metering, (b)off-ramp diversion and (c)signal timing at surface street intersections. The purpose of this study is to develop an integrated optimal control model in a freeway corridor. By approximating the flow-density relation with a two-segment linear function. the nonlinear optimal control problem can be simplified into a set of Piecewise linear programming models. The formulated optimal-control Problem can be solved in real time using common linear program. In this study, program MPL(ver 4.0) is used to solve the formulated optimal-control problem. Simulation results with TSIS(ver 4.01) for a sample network have demonstrated the merits of the Proposed model and a1gorithm.

  • PDF

Optimal Fuzzy Sliding-Mode Control for Microcontroller-based Microfluidic Manipulation in Biochip System

  • Chung, Yung-Chiang;Wen, Bor-Jiunn
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.196-201
    • /
    • 2004
  • In biometric and biomedical applications, a special transporting mechanism must be designed for the ${\mu}$TAS (micro total analysis system) to move samples and reagents through the microchannels that connect the unit procedure components in the system. An important issue for this miniaturization and integration is microfluid management technique, i.e., microfluid transportation, metering, and mixing. In view of this, this study presents an optimal fuzzy sliding-mode control (OFSMC) design based on the 8051 microprocessor and implementation of a complete microfluidic manipulated system implementation of biochip system with a pneumatic pumping actuator, a feedback-signal photodiodes and flowmeter. The new microfluid management technique successfully improved the efficiency of molecular biology reaction by increasing the velocity of the target nucleic acid molecules, which increases the effective collision into the probe molecules as the target molecules flow back and forth. Therefore, this hybridization chip was able to increase hybridization signal 6-fold and reduce non-specific target-probe binding and background noises within 30 minutes, as compared to conventional hybridization methods, which may take from 4 hours to overnight. In addition, the new technique was also used in DNA extraction. When serum existed in the fluid, the extraction efficiency of immobilized beads with solution flowing back and forth was 88-fold higher than that of free-beads.

  • PDF

Analysis of Utility Metering Data for Estimation of User Abnormal Life Status (사용자 비정상 생활상태 추정을 위한 유틸리티 검침 데이터 분석)

  • Baek, Jong-Mock;Kim, Byung-Gi
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.8
    • /
    • pp.85-93
    • /
    • 2011
  • In this paper, we analyzed the function elements of the Integrated meter reading system based on PLC which is working in Mok-dong, Seoul and studied how to improve the vulnerability. Also we propose an efficient method for the estimation of abnormal life status through frequency domain processing of utility meter readings. We found out that even after removing the high-frequency components from the raw meter data, the shape of the graph still maintains the original graph characteristics. The graph of the inverse transformed data has simpler and smoother curve than the original graph pattern. The original graph is not good to be used in deciding whether the residence's life pattern is normal or not. We could find out that the graph which is processed frequency signal has simple and intuitive graph pattern.

An Analysis of Effectiveness for Permissive Warrants on the Restrictive Left-Turn Signal Control in Urban Arterial Roads (도시 간선도로에서 제한적 좌회전 신호운영의 적용기준 및 효과분석에 관한 연구)

  • Jeong, In-Taek;Lee, Yeong-In
    • Journal of Korean Society of Transportation
    • /
    • v.27 no.5
    • /
    • pp.17-28
    • /
    • 2009
  • There are many limitations in dealing with rapidly changing traffic demand in urban cities. Thus recently, traffic operation and management skills are more emphasized rather than the expansion of traffic facilities. In particular, in the interrupted flow formed by signalized intersections, it is quite important to give optimal signal timing to each intersection with consideration of progression. However, as fixed signal times per direction can affect passing capacity in signalized intersections, the present four-signal phase including a left-turn signal has many limitations, including reduction of directional road capacity when traffic demand is increases dramatically during peak hours. Because of this problem, lots of studies about internal metering techniques for oversaturated signal control skills have progressed but these techniques are not used widely due to the absence of detectors for queue sensing in real-time signal control systems. In this research, a new methodology called the "restrictive left-turn signal control", which is already used at the intersection above Samsung subway station, is suggested in order to reduce control delay of urban arterial roads. The restrictive left-turn signal control allows a driver to make a U-turn and then a right turn instead of turning left in that intersection. With this change, the restrictive left-turn signal control can contribute to increased intersection capacity by reducing the number of signal phases and maximizing the through phase time. However, road structure and traffic conditions at the target intersections should be considered before the adoption of the proposed signal control.

Detect to Impulse Large Current based on faraday Effect (파라데이효과를 이용한 임펄스 대전류 측정)

  • Park, Hae-Soo;Kim, Yo-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.505-507
    • /
    • 1995
  • Applications of the fiber optic sensing are glowing rapidly, particularly in situations where size, weight, speed, and immunity to electromagnetic interference are important considerations. The fiber optic current sensors have been developed for low frequency(60Hz) metering in electric power systems. But we try measure to high frequency large current by fiber optic current sensor based on Bi substituted rare earth iron garnet. In this paper, we report the linearity to 500 amperes and frequency response of signal processor and a result of detection the standard impulse large current of fiber optic impulse sensor system.

  • PDF