• 제목/요약/키워드: Signal converter

검색결과 944건 처리시간 0.041초

광기법을 이용한 고정도 과도전압측정기 (High Quality Transient Voltage Measuring Device Using Optical Technique)

  • 이복희;길경석;전덕규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.441-443
    • /
    • 1995
  • A new optical-resistive voltage divider, which consists of light emitting diode, optic fiber, PIN-photo diode and a high qualify shielding resistive divider, whose total response time is 7.35 [ns], has been obtained. The optical to electrical signal converter was constructed with GaAsP series light emitting diode. The response characteristics have been verified by applying the Marx impulse voltage generator experimentally. Comparing with the performance of conventional resistive voltage divider, the characteristics of the proposed optical-resistive voltage divider are more excellent in step response and less sensitive to electromagnetic interference.

  • PDF

병렬 펄스 부하를 갖는 직류 전력시스템을 위한 Voltage Bus Conditioner의 전류 센서 없는 제어 (Current Sensorless Control of the Voltage Bus Conditioner for a DC Power System with Parallel Pulsed Power Loads)

  • 이병헌;장한솔;나재두;김영석
    • 전기학회논문지
    • /
    • 제61권11호
    • /
    • pp.1617-1624
    • /
    • 2012
  • A DC power system has many loads with varied functions. Also, there may be large pulsed loads with short duty ratios which can affect the normal operation of other loads. In this paper, Voltage Bus Conditioner(VBC) without any current sensors is proposed to damp the bus voltage transients by parallel pulsed loads. The proposed control approach requires only one voltage sensor and carries out both the functions of damping the bus voltage transients and maintaining the level of energy stored. The proposed control technique has been implemented on a TMS320F2812 Digital Signal Processor(DSP). Simulated results by a Matlab Simulink and experimental results are presented which verify the control principles and demonstrate the practicalty of the approach.

HILS 환경에서 AC/DC 마이크로그리드의 연계 컨버터 제어기 설계 및 테스트 (Design and Performance Test of Controller of Interlinking Converter in AC/DC Microgrid in Hardware-in-the-Loop Simulation Environment)

  • 지현균;유형준;김학만;이병하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.527-528
    • /
    • 2015
  • 최근 다양한 디지털기기에 따른 DC 부하의 증가와 함께 기존 배전망과 연계하여 운용할 수 있는 AC 그리드와 태양광과 연료전지 같은 DC 전원에 직접적으로 연계하여 운용하는 DC 그리드를 통합하는 AC/DC 마이크로그리드에 대한 연구가 진행되고 있다. 본 논문에서는 AC 그리드와 DC 그리드를 연계 제어하는 연계(interlinking) 컨버터의 제어기를 설계하고 성능을 검토하기 위해 TMS320F28335 DSP(Digital Signal Processor)와 실시간 디지털 시뮬레이터인 eMEGAsim으로 구성된 HILS(Hardware-in-the-Loop Simulation) 시스템을 구축하고 설계된 제어기의 성능을 테스트하였다.

  • PDF

전 디지털제어 전원장치 (Fully Digital Controlled Power Supply for PLS)

  • 하기만;김윤식;이성근
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.1011-1015
    • /
    • 2005
  • Fully digital controlled 20-bit magnet power supplies have been developed and successfully tested for closed orbit correction of PLS(Pohang Light Source). The new digital power supply has used fiber optics for 25kHz switching of IGBT drivers, and implemented DSP, ADC, Interlock, DCCT cards in a compact 3U-sized 19" chassis. Input/Output low-pass filters suppress harmonics of 60Hz line frequency and switching frequency noise effectively. Overall performance of the power supplies have been demonstrated as +/- 2ppm short-term stability(<1 min), and +/- 10ppm long-term stability(<36 hours). All the existing 12-bit 70 power supplies for vertical correction magnets will be replaced with new digital power supplies during 2005 summer shutdown period. In this paper, we will describe the hardware structure and control method of the digital power supply and the experimental results will be shown.

  • PDF

전류모드제어 방식을 이용하는 컨버터의 모델링 (Modeling of a Converter Utilizing Current Mode Control)

  • 정영석;이준영;강정일;윤명중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.275-278
    • /
    • 1998
  • The mathematical interpretation of a practical sampler which is useful to obtain the small signal models for the peak and average current mode controls is proposed. Due to the difficulties in applying the Shannon's sampling theorem to the analysis of sampling effects embedded in the current mode control, several different approaches have been reported. However, these approaches require the information of the inductor current in a discrete expression, which restricts the application of the reported method only to the peak current mode control. In this paper, the mathematical expressions of sampling effects on a current loop which can directly apply the Shannon's sampling theorem are newly proposed, and applied to the modeling of the peak current mode control. By the newly derived models of a practical sampler, the models in a discrete time domain and a continuous time domain are obtained. It is expected that the derived models are useful for the control loop design of power supplies. The effectiveness of the derived models are verified through the simulation and experimental results.

  • PDF

델터 변조 방식을 이용한 전류형 무효전력 보상장치 (Current-Fed Reactive Power Compensator Using Delta Modulation Technique)

  • 백형래;김한성
    • 대한전기학회논문지
    • /
    • 제41권3호
    • /
    • pp.244-252
    • /
    • 1992
  • This paper describes a reactive power compensator using current-source delta modulation converter, which compensates the reactive power in the ac sides of 3-phase rectifier. In the conventional current control methods for the current-type reactive power compensators, it is usual to compare the reactive reference current signal with the triangular wave and hence to generate the ON-OFF signals for the reactive power compensator. To improve the response as well as the control capability, the delta modulated current control technique is used in this paper. As a result, the input power factor is improved close to unity and both simulation and experimental results show good compensating performances.

  • PDF

Load Cell Noise 제거를 위한 Digital Load Cell 에 대한 연구 (A study on a digital load cell for the removal of load cell noise)

  • 이영진;이흥호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.562-564
    • /
    • 2002
  • Noise reduction and a simplification of a precision measurement system has been performed by changing analog output mode of a load cell into digital output mode. Usually, analog output signal of a few $\mu V$ from a load cell are amplified by amp and acquired by A/D converter. If the distance from a load cell to a DAS(Data Acquisition System) increases, more noise signals are mixed. So, a microprocessor has been integrated into a load cell so that the amplification and A/D conversion of output signals could be done in close proximity to the lode cell for the reduction in mixing of noise. Obtained data from the load cell like this manner are transferred to a computer with digital values(of TTL level). To simplify the configuration of a multi-channel DAS, RS-485 communication system has used for data transfer.

  • PDF

연속 전류 모드에서 Interleaved DC-DC Dual Boost 컨버터 소 신호 해석 및 제어기 설계 (Small Signal Analysis and Controller Design for Interleaved DC-DC Dual Boost Converter in Continuous Current Mode)

  • 박상은;손승찬;성세진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.378-380
    • /
    • 1999
  • Interleaved dual boost 컨버터는 전력분배 시스템에서 입력 전류 리플을 줄이고 스위칭 손실을 줄일 수 있고, 필터 없이 입력라인 고조파 성분을 줄일 수 있으며, 더불어 역률 개선의 효과를 이룰 수 있다. 본 논문에서는 Interleaved Dual Boost(IDB) 컨버터를 운전하는 경우에 있어서 상태 공간 평균화법을 사용하여 소 신호 해석을 수행하였다. 그 해석 결과로 얻진 제어 전달 함수를 바탕으로 IDB 컨버터에 적합한 수 개의 제어기를 설계하였다. 시뮬레이션을 행한 결과로 얻어진 여러 가지 제어기 타입의 각 특성을 분석하고 그 중 IDB 컨버터로 가장 적절한 제어기를 제안하였다.

  • PDF

Solar Cells Characteristics Tester

  • Jirawath, Parnklang;Amnard, Jenjirodpipat;Santi, Hanklar
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.511-511
    • /
    • 2000
  • The equipment is used for testing the electrical characteristics of solar cells that were connected to be a solar panel, which can be found anywhere of solar power plant. This device was built from power switch devices f3r sinking the high current of the solar panel. The processor is a controller, which controls the quantity of the current, which flow through the switching devices and collect the characteristic of the solar panel. The tester can measure the current, voltage, temperature, and light intensity, which are main factors that affect the electrical characteristics of solar cells. 12 bits resolution signal converter is used to change the measuring levels so we can change measuring levels to 4096 levels, and these data are stored in tile memory. The equipment can also calculate the maximum power of the solar system panel.

  • PDF

초고속 스캔형 자기카메라에 의한 고속열차 차륜 탐상 (Inspection of Cracks on the Express Train Wheel Using a High Speed Scan Type Magnetic Camera)

  • 이진이;황지성;권석진;서정원
    • 대한기계학회논문집A
    • /
    • 제32권11호
    • /
    • pp.943-950
    • /
    • 2008
  • A novel nondestructive testing (NDT) system, which is able to detect a crack with high speed and high spatial resolution, is urgently required for inspecting small cracks on express train wheels. This paper proposes a high speed scan type magnetic camera, which uses the multiple amplifying circuits and the crack indicating pulse output system. The linearly integrated Hall sensors are arrayed in parallel, and the Hall voltages from each sensor in the scanning direction are obtained and amplified. High-speed NDT can be achieved by using the exclusive analog-digital converter and micro-processor because the ${\partial}\;V_H/\;{\partial}$ x value, which provides the most important crack information, can be obtained by buffering and calculating. The effectiveness of the novel method was verified by examine using cracks on the wheel specimen model.