• Title/Summary/Keyword: Signal Fluctuation

Search Result 237, Processing Time 0.026 seconds

Experimental Study on the PWM Pressure Control Characteristics of 2 Way Solenoid Valve (2방향 전자밸브 PWM압력제어특성의 실험적 비교연구)

  • 정헌술;박성진;김창완
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.107-111
    • /
    • 1997
  • Pressure control is possible by pulse width modulation signal driving a simple ON/OFF 2-way valve of hydraulic servo system. But it indices pressure fluctuation due to repeated on-off action and the pressure varies according to the duty ratio and carrier frequency. So mean pressure and ripple amplitude are arranged by experimental study as the driving signal change which decides the pressure characteristics. As the result selection criteria of the major design parameters may be established and the basic strategy to suppress the unnecessary flucturion may be provided for a hydraulic pressure control system.

  • PDF

Implementation of fiber-optic temperature sensor system base on optical absorption device (광흡수 소자를 이용한 광온도 센서 시스템의 구현)

  • 김영수;김요희
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.9
    • /
    • pp.128-134
    • /
    • 1995
  • A fiber-optic temperature sensor utilizing an optical absorption device (InP) was fabricated. The spectrum of transmitted light through an InP device was obtained at the three temperatures(249 K, 369 K). A stabilized LED(light emmiting diode) driver, photoreceiver, and signal proocessing electronics were designed. An intensity referencing technique was adopted in order to minimize the fluctuation of output signal due to external pertubation of the transmitting optical fiber. The optical absorption edge of the InP device moves to longer wavelength at a rate of 0.42 nm / K, and energy gap of InP is 1.35 eV at room temperature. From these results, it is concluded that the InP device has temperature dynamic range of 300 K with LED of center wavelength of 940nm and spectral width of 50nm. The designed fiber-optic temperature sensor system showed good linearity within the temperature range from -30$^{\circ}C$ to + 150$^{\circ}C$.

  • PDF

Negative Dynamic Resistance and RF Amplification in Magnetic Tunnel Junctions

  • Tomita, Hiroyuki;Maehara, Hiroki;Nozaki, Takayuki;Suzuki, Yoshishige
    • Journal of Magnetics
    • /
    • v.16 no.2
    • /
    • pp.140-144
    • /
    • 2011
  • We report on a numerical calculation study of two new functional properties in magnetic tunnel junctions (MTJs), negative dynamic resistance and RF amplification. The magnetic dynamics in a conventional CoFeB/MgO/CoFeB MTJ with in-plane magnetization was investigated using a macro-spin model simulation. To examine the influence of thermal fluctuations, random external magnetic fields were also included. Using a voltage controlled bias circuit, the negative dynamic resistance was obtained from time averaged I-V characteristics at both 0 K and 300 K under appropriate external magnetic fields and bias voltages. Using this negative dynamic resistance property, we demonstrated RF amplification with a 100 MHz high frequency signal. Sizable RF amplification gain was observed without thermal fluctuation. However, at 300 K, the RF signal was not amplified because low frequency magnetization dynamics were dominant.

CSK Signal Transmission Characteristics at the Load Variation Channel (부하변동을 수반하는 전송 채널에서의 CSK 신호의 전송 특성)

  • 오경석;주창복
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.3 no.3
    • /
    • pp.617-626
    • /
    • 1999
  • For the purpose of high speed and reliable data transmission through the frequency response variation channel by load fluctuation, we present CSK signal transmission characteristics by computer simulation. Also using the simple structure of Roll-off filter at the CSK receiving system, the exact synchronization tracking and data detection without error at the worst case of S/I=2 and S/N=2 were achieved.

  • PDF

Development of Portable Cadiovascular Signal Analysis System (휴대형 심혈관 신호해석장치의 개발)

  • Lee, D.J.;Lee, J.W.;Kim, H.S.;Lee, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11b
    • /
    • pp.663-665
    • /
    • 1998
  • The purpose of this paper is development of portable cardiovascular signal processing device. Beat-to-beat fluctuation in heart rate, respiration, and blood pressure have been known to be meditated by autonomic nervous system activities convergent on various effector organs. This system consists of data acquisition module, main data processing module and graphic LCD module. The data acquisition module is developed for data aquisition, data multiplexing and interfacing with main data processing system. And, main data processing module is developed for data storing, data processing and interfacing with graphic LCD module. The main processing system is based on 32-bit microprocessor.

  • PDF

Bandwidth-Efficient Precoding Scheme with Flicker Mitigation for OFDM-Based Visible Light Communications

  • Kim, Byung Wook;Jung, Sung-Yoon
    • ETRI Journal
    • /
    • v.37 no.4
    • /
    • pp.677-684
    • /
    • 2015
  • Recently, orthogonal frequency-division multiplexing (OFDM) was applied to VLC systems owing to its high rate capability. On the other hand, a real-valued unipolar OFDM signal for VLC significantly reduces bandwidth efficiency. For practical implementation, channel estimation is required for data demodulation, which causes a further decrease in spectral efficiency. In addition, the large fluctuation of an OFDM signal results in poor illumination quality, such as chromaticity changes. This paper proposes a spectrally efficient method based on a hidden-pilot-aided precoding technology for VLC with less flickering than a conventional OFDM-based method. This approach can obtain channel information without any loss of bandwidth efficiency while ensuring illumination quality by reducing the flickering effect of an OFDM-based VLC. The simulation results show that the proposed method provides a 6.4% gain in bandwidth efficiency with a 4% reduction in flicker compared to a conventional OFDM-based method.

MRI Artifact Correction due to Respiratory Motion (호흡운동에 따른 MRI 아티팩트 수정)

  • 김응규;김규헌
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2003.06a
    • /
    • pp.58-61
    • /
    • 2003
  • In this study, a planar respiratory motion is modeled by a 2-D linear expanding-shrinking movement. According to the introduced model, respiratory motion imposes phase error, non-uniform sampling and amplitude modulation distortions on the acquired MRI data. When the motion parameters are known or can be estimated, a construction algorithm based on superposition method was used to remove the MRI artifact. For the purpose of estimating unknown motion parameters, we used the spectrum shift method to find the respiratory fluctuation function, the x directional expansion coefficient and its center, and we also used the minimum energy method to find the y directional expansion coefficient and its center. Finally the effectiveness of this presented method is shown by computer simulations.

  • PDF

Performance Analysis of MSAGF-MMA Adaptive Blind Equalization Algorithm with Variable Step Size Using Input Power Signal and Decision-Directed Error Signal (입력 전력 신호와 결정지향 오차 신호를 이용한 가변 스텝 크기를 가지는 MSAGF-MMA 적응 블라인드 등화 알고리즘의 성능 분석)

  • Jeong, Young-Hwa
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.3
    • /
    • pp.53-58
    • /
    • 2020
  • This paper is concerned with the performance analysis of MSAGF-MMA with variable step size whose step size varies according to input power signal and decision-directed error signal. The proposed algorithm is made to change according to the input power signal which can reliably increase the convergence speed to the steady state by making the step size less affected by the fluctuation of the input signal in the MMA having the binary flag obtained from the modified Stop-and-Go algorithm. At the same time, the step size can be varied according to the decision-directed error signal so that the residual error can be reduced in the steady state. As a result of computer simulations, it is confirmed that the proposed algorithm has a very good performance in the evaluation of residual ISI and averaged-MSE in steady state as well as in terms of convergence speed to steady state compared to MMA and MSAGF-MMA.

High Frequency Signal Analysis of Oxidizer Pump for 7-tonf Turbopump (7톤급 터보펌프 산화제펌프의 고주파 신호 분석)

  • Bae, Joon-Hwan;Choi, Chang-Ho;Choi, Jong-Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.6
    • /
    • pp.61-68
    • /
    • 2020
  • 7-tonf turbopump real-propellant tests in Naro Space Center were conducted and high-frequency signals from an accelerometer and pressure sensors installed on the casing and the inlet/outlet pipeline of LOX pump were analyzed to estimate the structural and hydrodynamic stabilities. Waterfalls, frequency spectrums and RMS(Root Mean Square) values of the measured signals were calculated and characteristic instability frequencies by the rotating cavitation and the rear floating ring seal(F.R.S) were investigated. Static pressures of the inlet/outlet pipeline and an acceleration of the pump casing are strongly affected on pressure fluctuation induced by the rear floating ring seal in the leakage path. Despite the acceleration RMS value seems totally small, the rotating-speed-related synchronous frequency affecting the shaft instability is distinctly observed in the frequency contour.

Comparison of Voice Characteristics Before and After High-Caffeine Intake (고카페인 섭취 전·후 음성 특성 비교)

  • Lee, Areum;Kim, Eunyun;Yoo, Hyunji;Choi, Yaelin
    • Phonetics and Speech Sciences
    • /
    • v.7 no.4
    • /
    • pp.59-65
    • /
    • 2015
  • This study was conducted to identify the differences in voice characteristic variables before and after taking a certain amount of high-caffeine. Linear PCM-M10 Recorder (SONY) was used for the recorder and basic frequency of the voice (Fo), frequency fluctuation rate (jitter), amplitude fluctuation rate (shimmer) and Signal-to-Noise Ratio (SNR) were measured using TF-32(University of Wisconsin-Madison, USA). First, prolonged phonation analysis results of /ah/ by male subjects showed the shimmer values after taking high-caffeine increased statistically significantly(p<.05) compared with before the intake and SNR values significantly decreased. (p<.05). On the other hand, female subjects didn't show any statistically significant differences in all variables. Second, male subjects showed statistically significant increased shimmer values after the intake compared with before the intake at /ah/ of syllable 'na' and /ah/ in 'ra' in 'autumn' paragraph (p<.05), and jitter values significantly increased at /ah/ in 'ah' (p<.05). However, female subjects didn't show any statistically significant differences in all variables. Results of this study showed that high-caffeine intake more affects male subjects than female subjects. In male subjects, shimmer and SNR changed at vowel prolonged phonation, /ah/, and study results showed that shimmer and SNR in 'Autumn' paragraph /na/, /ra/ and jitter in /ah/ could be identified as the variables to show the voice change.